Laminar Flow Cabinets and Workstations



Similar documents
LAMINAR FLOW CABINETS

FlowFAST V. Vertical Laminar Airflow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Stainless Steel Worksurface 3 Feet Hood A10-WS-PR3 A10-WS-SR3 4 Feet Hood A10-WS-PR4 A10-WS-SR4 6 Feet Hood A10-WS-PR6 A10-WS-SR6.

Laminar Flow Cabinets

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

OPERATING MANUAL LAMINAR FLOW WORKSTATION MODELS M50545 M50546 M50547 M50548 M (TM060-O&M-001 Revision 3)

ASALAIR BIOHAZARD CABINET MODEL ATLANTIC CYTOCABINET 1200 CLASS II TYPE A2 COD MICROBIOLOGICAL SAFETY CABINET CLASS II TYPE A2

Spetec. Laminar Flow Box. Portable Clean Room Technology

Environmental Monitoring

Risk Assessment: Biosafety Cabinet

Cleanroom Solutions Ltd T: F: E: W:

Bassaire K-Range Laminar Flow Cabinet

LAMINAR FLOW FOR ALL YOUR NEEDS

LAMINAR AIRFLOW EQUIPMENT CLASS I BIOLOGICAL SAFETY CABINETS BIOLOGICAL ENCLOSURES

Spetec. Clean room. technology. Laminar flow box Clean room workbench CleanBoy Clean room cell Service, certification

Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health

Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories

WIBObarrier OCS - Open Containment Systems WIBObarrier CCS - Closed Containment Systems

BENCH TECH 150. IVD In vitro diagnostic-medical device. General information Type of instrument: Bench chemical hood. Technical datasheet BenchTech150

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

Protection, safety, reliability. And more. LAMINAR FLOW CABINETS AND SYSTEMS

Downflo workstation DuSt ColleCtorS

Laminar Flow Hoods and Booths

LAMINAR FLOW HORIZONTAL FLOW BENCH (LF) OPERATION & MAINTENANCE MANUAL

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Chemical Fume Hoods. Environmental Health and Safety

Shakers, Incubators, Clean Benches, Water Baths, Drying Ovens

Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories

Environmental Monitoring of Clean Rooms

Procedures for the Effective Use of Biological Safety Cabinets

Ultra-Violet Products Ltd 2066 W 11th Street, Upland, CA Unit 1, Trinity Hall Farm Estate

- 2 - IMPORTANT SAFETY REMINDERS

SPECIAL APPLICATIONS

Particle Monitoring Requirements in Pharmaceutical Cleanrooms

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

UniMax Large Floor Mount (Walk-In) Fume Hoods

Decontamination Showers

OPERATOR S MANUAL. EdgeGARD Horizontal Laminar Flow Clean Bench

Adsorption air dryers ADS 1 215

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

Kompressoren. Adsorption Dryer AD

TRIMMING TECH 150. IVD In vitro diagnostic-medical device. General information. Technical datasheet Trimmingtech150

Spetec Laminar Flow Systems. Operating Instructions

Vacuum drying oven for non-flammable solvents

Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace

Air Shower Biosafety Changing Station with Pass-Through Box Pass-Through Box Automatic atomizer for no-contact hand disinfection

Particle testing in cleanroom high-pressure gas lines to ISO made easy with the MET ONE 3400 gas calibrations

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

SECTION GUARDA SECURITY WINDOW SCREENS

GMP ANNEX 1 REVISION 2008, INTERPRETATION OF MOST IMPORTANT CHANGES FOR THE MANUFACTURE OF STERILE MEDICINAL PRODUCTS

Fume Cupboard Guidance

MAC 10. Original & IQ FAMILY OF FAN FILTER UNITS

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

CLASSIFICATION OF CLEANROOMS

Range Equipment HVAC Design & Supply Modular Ranges

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG March 24, 2010

Product Overview Benefits

RPV - RP - RA air handling units

Environmental Monitoring

Data Centre and Server Room Technical Cleaning

Aerospace and Defence

In Vitro Fertilization Workstation. Esco IVF Workstation, Model IVF-4A_. Shown with optional support stand.

Cleanroom. For. Sterile Manufacturing Facilities

Cleaning. By the end of this chapter, you will be able to: Introduction. Definitions. Chapter 9

TARIFF CODE and updates standard

CelCulture. CelCulture CO2 Incubator Model CCL-170_-_. CO2 Incubator with Integrated Cooling System Solution for Highly Specialized Applications

CLEAN ROOM MONITORING REGULATORY STANDARDS

Series 18 Pass Thru Air Lock Cleanroom Entry System

Medical Air Systems: Scroll

Linkeo 19" freestanding cabinets

Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to

Effectiveness of Engineering controls (LEVs)

3M Purification Inc. 3M Air Management Products for Your Commercial HVAC Needs. Create. Air. Confidence

IH E Sigma Island 90

Archive solutions Your objects of historical value and legal documents deserve intelligent storage solutions

SSG PRODUCTS FOR SHIPS AND OFFSHORE

DOE-HDBK Module 2.18 Air Sampling Equipment. Instructor s Guide

Paint Test Equipment. Stargloss Gloss Meter Data Sheet

techorganizer and techbench built for durability, designed for flexibility

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

UNITOR VACUUM cleaners

BIOLOGICAL SAFETY CABINET PROGRAM

Hospital Sterilizers. T-Max Line

AUTOCLAVE STEAM STERILIZERS

Material test chamber with mechanical convection

ECLIPSE THE ULTIMATE MULTI-PURPOSE SHELVING SYSTEM. UP TO 360kg SHELF CAPACITY QUICK & EASY BOLT-FREE ASSEMBLY STRONG, ROBUST & MODERN DESIGN DESIGN

DIGITUS Network & Server Cabinets. UNIQUE Series

19 DYNAmax Free Standing Server C A B I N E T s

Corrugated Tubular Heat Exchangers

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

How To Order A Direct Flow Air Cleaner

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: w.tecni-ar.com.br

2. The Laboratory Fume Hood Specification Catalog Select the style and size hoods appropriate for your layout and laboratory use.

HEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom. Frequently Asked Questions

Static Clean International

Atlas Copco Quality Air Solutions. Compressed Air Filters

Transcription:

VERTICAL AND HORIZONTAL HEPA FILTERED SYSTEMS FOR PROCESS OR OPERATOR PROTECTION Laminar Flow Cabinets and Workstations For procedures requiring protection from particulate contamination and for aseptic techniques Cabinet includes optional lighting & electronic control panel. Email: info@bigneat.com Tel: +44 (0)23 92 266400 BIGNEAT CONTAINMENT TECHNOLOGY Value. Service. Experience.

Laminar Flow Cabinets & Workstations Bigneat s Laminar Flow Workstations have been specifically designed to be affordable yet to provide particle-free, bacteria-free, clean air conditions to the work area at a quality standard usually only possible in more expensive cabinets. A cabinet may be positioned on an existing bench or can be supplied as a free standing system on a supporting mobile bench or static stand with adjustable height feet. Laminar Flow Cabinets are manufactured to a very high standard using only the best quality materials, fans and components. Materials used are resistant to corrosion and easy to clean. Experience has shown that Bigneat Laminar Flow Cabinets give consistent performance which is only dependent on replacement of the pre- and HEPA filters at recommended intervals. Description and Operation Room air is drawn into the top of the cabinet, passes through the pre filter and enters the fan housing. The speed controllable fan pushes the air through the HEPA filter located above the working area. Ultra-clean air exits the HEPA filter to provide a sterile working environment which protects the samples and manipulations from external contamination. The cabinet structure is fabricated from 10mm thick clear UV stabilised cast acrylic which provides excellent all-round visibility for the operator whilst carrying out manipulations and aseptic procedures. Key Features Comfortable to use Excellent view of working area Quiet operation Included as standard Flexible access Easy to maintain Meets all worldwide standards A variable fan speed control (pre-set at factory, adjustable by installation/service engineer. Magnehelic differential pressure gauge for monitoring filter performance. HEPA Filtration to remove particles greater than 0.3micron @ 99.995% efficiency. Pre-filtration to remove particles greater than 5micron @ 92% efficiency. HPL work surface with margin groove to catch and contain spills. Service port in each side panel. Typical applications For materials or processes that require protection from particulate contamination: Semiconductor handling, laboratory procedures, preparation of sterile medical devices and materials, in pharmaceutical research and food, for cell culture, PCR and RNA and many other general industry uses requiring a particulate-free or sterile environment. LAMINAR FLOW WORKSTATION Definition and classification of clean air safety systems as specified by ISO 14644 A dedicated space in which the concentration of airborne particles is controlled and is constructed and used in a manner to minimise the introduction, generation and retention of particles inside the zone. Laminar Airflow Airflow moving along parallel flow lines minimises air turbulence within the workstation. Filtration & Standards lami nar flow Pre-filtration eliminates particles 5.0 microns or greater to an efficiency of 92% as defined in BS EN ISO 779. HEPA filtration (H14 Standard) eliminates particles 0.3 microns or greater to an efficiency of 99.995% providing ultra-clean particle-free Class 5 BS EN ISO 14644-1:2000 air conditions. Laminar Flow Cabinets are manufactured to comply with the guidelines of ANSI.IEST/ISO 14644 1:1999 Class 5, also described as Class 100 or FED STD-209- D:1988, to provide sterile working environment and air velocity at filter face of 0.45 m/s. HLFO Operator Protection Workstation includes Carbon Filtration which has a filtration efficiency of 99.9%, meets BS 7989:2001 Standard. www.bigneat.com

Vertical Laminar Flow (VLF) ROOM INTAKE VLF cabinets are available in 3 different widths; 1m, 1.5m, 2m. Fan housing design ensures that the positive pressure developed pushes air evenly across the full width of the filter. Base tray (HPL) has margin groove to catch and contain spillages. May be installed on existing bench or be supplied with a robust static stand. VLF Cabinets are flat-packed for easy shipment around the world. *Optional lighting & electronic control panel is shown in picture Room air enters the fan housing and passes through the filtration system delivering sterile particulate air to the work area. When your choice is sterile air delivered downwards onto the work area then a Bigneat VLF cabinet/ workstation is ideal. It offers a particle-free, clean-air environment with all-round view into the work area. The acrylic frameless construction allows the operator to work by laboratory illumination and natural light and eliminates the need for internal lighting (offered as an option). HEPA Filter Horizontal Laminar Flow (HLF) ROOM INTAKE HLF cabinets are available in 3 different widths; 1m, 1.5m, 2m. Fan housing design ensures that the positive pressure developed pushes air evenly across the full width of the cabinet work area. Base tray (HLF) has margin groove to catch and contain spillages. May be installed on existing bench or be supplied with a robust static stand. HLF Cabinets are flat-packed for easy shipment around the world. HEPA Filter Service Port Room air enters the fan housing, through the filtration system and passes down the back of the cabinet through the mesh to the rear of the cabinet delivering sterile particulate air across the work area. *Optional electronic control panel is shown in picture When your choice is sterile air delivered horizontally across the work area then a Bigneat HLF cabinet/ workstation is ideal. It offers a particle-free, clean-air environment with excellent view into the work area to the front and through the side panels. Operator Protection Workstation (HLFO) When it is required to protect the operator from particulate and also chemical fumes or solvents vapours which are released during your handlings and procedures, then a Bigneat HLFO cabinet/workstation is ideal. Essentially of the same design as a HLF cabinet/workstation with flow reversed and filtration system reconfigured with a more powerful fan and different filter arrangement. It returns particle-free, clean-air, back into the laboratory and provides an even flow across the work area. This cabinet style allows excellent view into the work area to the front and through the side panels. Manufacturing in the UK since 1972. ROOM INTAKE HEPA/Carbon Filters (optional) Service Port Room air enters the cabinet passing the operator and horizontally through the rear mesh back panel, up the back of the cabinet and through the filtration system returning clean air back into the laboratory.

PRODUCT DESCRIPTION & SPECIFICATIONS Vertical Laminar Flow Cabinets (VLF) Bigneat VLF Laminar Flow Cabinets are delivered complete with pre-filtration, HEPA particulate filter(s) and are factory calibrated for immediate use once assembled. Cabinets are supplied with an on/off switch for the fan, and a Magnehelic differential pressure gauge for monitoring filter performance. The fan housing is fabricated from mild steel with an epoxy chemical resistant, white coating. Side panels are manufactured from transparent clear cast acrylic which is non-flammable and easy to clean (10mm thick) and each is fitted with a services port. The integrated work surface is manufactured from HPL and has a margin groove to catch spills. VLF 1000 1000 x 725 x 1040 966 x 700 x 700 <65dBa 0.45 m/s VLF 1500 1500 x 725 x 1040 1466 x 700 x 700 <65dBa 0.45 m/s VLF 2000 2000 x 725 x 1040 1966 x 700 x 700 <65dBa 0.45 m/s Horizontal Laminar Flow Cabinets (HLF) Bigneat HLF Laminar Flow Cabinets are delivered complete with pre-filtration, HEPA particulate filter(s) and are factory calibrated for immediate use once assembled. Cabinets are supplied with an on/off switch for the fan and for the integral fluorescent tube lighting and a Magnehelic differential pressure gauge for monitoring filter performance. The fan housing and back panel is fabricated from mild steel with an epoxy chemical resistant, white coating. Side panels are manufactured from transparent clear cast acrylic which is non-flammable and easy to clean (10mm thick) and each is fitted with a services port. The integrated work surface is manufactured from HPL and has a margin groove to catch spills. HLF 1000 1000 x 762 x 1160 960 x 600 x 665 <65dBa 0.45 m/s HLF 1500 1500 x 762 x 1160 1460 x 600 x 665 <65dBa 0.45 m/s HLF 2000 2000 x 762 x 1160 1960 x 600 x 665 <65dBa 0.45 m/s Operator Protection Workstation (HLFO) Bigneat HLF Laminar Flow Cabinets are delivered complete with pre-filtration, Chemcap carbon and HEPA filtration and are factory calibrated for immediate use once assembled. Cabinets are supplied with an on/off switch for the fan and the integral fluorescent tube lighting and a Magnehelic differential pressure gauge for monitoring filter performance. The fan housing and back panel is fabricated from mild steel with an epoxy chemical resistant, white coating. Side panels are manufactured from transparent clear cast acrylic which is non-flammable and easy to clean (10mm thick). The integrated work surface is manufactured from HPL and has a margin groove to catch spills. HLFO 1000 1000 x 762 x 1160 960 x 600 x 665 <65dBa 0.45 m/s HLFO 1500 1500 x 762 x 1160 1460 x 600 x 665 <65dBa 0.45 m/s HLFO 2000 2000 x 762 x 1160 1960 x 600 x 665 <65dBa 0.45 m/s

Options and Accessories Ref Item Description Available for Laminar Flow Cabinet Model VLF HLF HLFO MT Bench for cabinet, open box-section framework with OPTION OPTION OPTION levelling/adjustable feet. MTA Bench for cabinet with 2 leg frame, electrical height OPTION OPTION OPTION adjustment and levelling/adjustable height feet. EC Electronic touch button control panel incorporating LED OPTION OPTION OPTION airflow indicator and audible and visual alarms. L Fluorescent tube lighting. OPTION STANDARD STANDARD UF Upgrade to ULPA filtration (Grade U16). OPTION OPTION IB Ionising bars for controlling the static environment OPTION OPTION OPTION SK Tap (air, gas, vacuum). Installed through side panels or OPTION OPTION OPTION through work surface if cabinet is provided with an optional bench. Supplied with suitable flexible tubing (2m). ES Electrical plug socket (double). OPTION OPTION OPTION BS Upgrade to stainless steel work surface (304L) with front OPTION OPTION OPTION spillage lip. D Removable front night door. OPTION OPTION UV Ultraviolet sterilisation lamp with timer and key switch OPTION OPTION OPTION with acrylic panels blackened for protection, supplied with front night door. Bench Option Your laminar flow cabinet can be provided with an open box-section bench with levelling/adjustable feet or there is an electrically operated height adjustable bench alternative. Magnahelic Gauge as fitted in base model On-going product development BIGNEAT reserves the right to make modification to designs shown within this brochure in line with our policy of continual product improvement. Quality Assured Bigneat is accredited to BS EN ISO 9001: 2008. Bigneat systems are CE marked. Services Port and filter mesh shown in HLF workstation Comprehensive product range supported by a worldwide network of representatives. Please visit our website for an up-to-date list at: www.bigneat.com Bigneat Limited 4 & 5 Piper s Wood Industrial Park, Waterberry Drive, Waterlooville, Hampshire PO7 7XU UK Tel: +44 (0)23 92 266400 Fax: +44 (0)23 92 263373 E-mail: info@bigneat.com print 07/14 BIGNEAT CONTAINMENT TECHNOLOGY Value. Service. Experience.