Chapter 2: Foundations



Similar documents
Foundation. Foundation

State of Connecticut Department of Public Health RADON PROGRAM

INCORPORATION BY REFERENCE OF INTERNATIONAL. (1) The Department of Labor and Industry adopts and incorporates by

Comment Form on Proposed Gut Rehabilitation Alternatives

The Closed Crawl Space: Making the Transition Climate Zones 3A & 4A

COMMONLY USED RESIDENTIAL BUILDING CODES

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

2014 British Columbia Building Code Changes

IECC Compliance Guide for Homes in Virginia

2009 IECC Update. Scope. Content. International Energy Conservation Code

BUILDING IN ALASKA HCM-00952

Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers

BUILDING PERMIT SPECIFICATIONS

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill

RELEASE NOTES EG USA 3.0.0

Pre-Drywall Inspection Report

Building Energy Codes 101 October 23, Matthew Giudice Building Policy Associate Midwest Energy Efficiency Alliance

BUILDING SAFETY UNIT

CLOSED CRAWLSPACES. Have you ever been in your crawlspace? If not, have you ever even

Basement Moisture Problems

CRAWLSPACE ISSUES IN THE NORTHWEST

Additions and Alterations

How To Repair A Boat Landing Deck With A Boat Bed

Heating Load Calculation

Building Code Inspections and Fees

Indiana Energy and Cost Savings

Table of Contents. Comments on the Technical Bulletins should be directed to:

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

The minimum reinforcement for the stem wall is the placement of:

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Residential Foundations and Basements

Development Services City of Lawrence, KS

ENERGY STAR Certified Homes, Version 3 Cost & Savings Estimates

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

Tennessee. Energy and Cost Savings. for New Single and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

Insulating Basements: Part 3 Basement Wall Systems

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

HVAC Code Requirements

Building Condition Assessment Report

Single Family Residential Basement Finish

Residential Buildings Energy Code Summary

Colorado Energy and Cost Savings

RULING OF THE MINISTER OF MUNICIPAL AFFAIRS AND HOUSING

CITY PLAN REVIEW AND INSPECTION. Lisa Fleming Brown, CPM

Mississippi. Energy and Cost Savings. for New Single and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

1995 Model Energy Code Version 2.0

What you need to know about concrete block basement construction.

Category Measure Minimum Efficiency / Certification Requirements

Inspecting to a higher standard.

Rehab Inspection Report Page 1

ECHO System for Basements

STEPS TO CONSTRUCTING A MOISTURE-RESISTANT FOUNDATION SOURCES OF MOISTURE IN NEW CONSTRUCTION. Natural ground slope

APPENDIX C FORMS 2010 FLORIDA BUILDING CODE ENERGY CONSERVATION C.1

Table 1: Prescriptive Envelope Requirements: Residential WOOD FRAME WALL R-VALUE MASS WALL R-VALUE CEILING R-VALUE

Analysis of 2009 International Energy Conservation Code Requirements for Residential Buildings in Kansas City, Missouri

Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen

CERTIFICATE OF COMPLIANCE Prescriptive Residential Re-roof Project Name:

Excerpts from the Canadian National Building Code (NBC)

Elevating Your House. Introduction CHAPTER 5

Residential Inspection Guidelines

) SIGNIFICANT CHANGES INCLUDING CODE COMMENTARY

DELTA Premium Moisture Management Systems for Foundations.

HVAC INSTALLATION. Success with 2015 IECC Northeast & Mid-Atlantic. Checklist for Builders & Trades

research highlight Highly Energy Efficient Building Envelope Retrofits for Houses

Report on Sanctuary/Chancel Crawl Space Inspection. St. John in The Wilderness, 2896 Old Lakeshore Road Bright s Grove. Project No.

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Revised Builder s Guide to Frost Protected Shallow Foundations

HVAC INSTALLATION SUCCESS WITH 2012 IECC DELAWARE. for Builders & Trades. Recommended Practices for Optimized Energy Savings

WET/DAMP BASEMENTS ANSWER: BASEMENT WALLS AND FLOORS CAN BECOME WET BY A LEAK, CAPILLARY SUCTION OR CONDENSATION.

159 Morningside Avenue, Toronto

bout your HOUSE before you start Renovating Your Basement Structural Issues And Soil conditions

Renovating Your Basement

Chapter 3 Pre-Installation, Foundations and Piers

How to Identify, Evaluate & Repair Shrinkage Cracks in Poured Concrete

Cuyahoga County Urban Mold & Moisture Project

Vision Home Inspection

Appendix F EPA's Model Standards and Techniques for Control of Radon in New Residential Buildings

Page & Turnbull imagining change in historic environments through design, research, and technology

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

POST AND FRAME STRUCTURES (Pole Barns)

PERFORMANCE GUIDELINES

Attachment #23 Health Safety Table. Client Education Inform issue and document. How to clean & maintain gutters. How to adjust sprinklers

Prestige Home Inspection LLC

What I will cover: Cuyahoga County Urban Mold & Moisture Project. Mold & moisture problems. Mold and moisture problems. Mold & moisture problems

Zen House. A Case Study on Design, Construction and Cost/benefit Analysis of a High Performance Home. Presentation for Net Zero Networking & Exchange

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money

Exterior Elevated Elements Inspection Guidelines

BUILDING ENERGY CODES: Creating Safe, Resilient, and Energy-Efficient Homes

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Name of course: Residential Construction Site Management (RCSM) Level 1

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

How To Build A Basement House

Transcription:

Chapter 2: Foundations Crawlspace [V502.1.2] Vents. Vents in the crawlspace help keep floor insulation and floor framing dry. Crawlspace vents also reduce the potential for radon buildup under the floor. Ventilation required is equivalent to the Washington State amendments to the International Residential Code (IRC) requirement (1 sq.ft. of net free vent area for each 300 sq.ft. of crawlspace area, or 1/300 sq.ft.). Vents must be placed below floor insulation (see Figure 2-1) or they must be properly baffled (see Figure 2-2). Insulation. If you choose a prescriptive compliance path, the Washington State Energy Code (WSEC) requires that the floor over the crawlspace be insulated to the required value determined by using WSEC Tables 6-1 or 6-2. Figure 2-1 Foundation Vent WSEC Builder s Field Guide, 8th Edition, 2009 Washington State University Extension Energy Program 2-1

Figure 2-2 Baffled Foundation Vent ("Good Practice") [502.1.4.8] Thermal Break. Where a crawlspace stem wall abuts a slabon-grade within a conditioned space, insulation must be used to create a thermal break (see Figure 2-3 for possible detail.) [502.1.6.7] Ground Cover. Six-mil black polyethylene (or approved equal) must be laid over the ground within all crawlspaces. The ground cover: Must extend to the foundation wall. Seams must be lapped 12 inches (see Figures 2-1 and 4-6). May be omitted if a minimum 3-1/2-inch concrete slab is poured in the crawlspace. Chapter 2-2 WSEC Builder s Field Guide, 8th Edition, 2009 Washington State University Extension Energy Program

Figure 2-3 Thermal Breaks WSEC Builder s Field Guide, 8th Edition, 2009 Washington State University Extension Energy Program Chapter 2-3

Slab-On-Grade [201.1] Defined by the Code as any slab with its top surface less than 24 inches below the final exterior grade (see Figures 2-4, 2-5, and 2-7). In such cases, you must: [502.1.4.8] Maintain a thermal break at the edge of a slab. Slabs must not run continuously from heated to unheated areas (See Figures 2-8 and 2-9). Extend R-10 insulation for a total of 24 inches either vertically or a combination of vertically and horizontally around the entire on-grade perimeter. Install water-resistant insulation material manufactured for this purpose. Install a cover flashing or parging to protect the insulation from moisture and physical damage above grade. [502.1.4.9] Radiant Slabs. If a radiant heating system is to be installed in a slab, a minimum of R-10 insulation (all zones) is required under the slab. The entire area of radiant slab in contact with the ground must be thermally isolated (see Figure 2-6). Notes: Ducts. Any heating system ductwork in or under a slab must be insulated to R-5 with insulation manufactured for this use. Pipes. Any hot water pipes buried under a slab must be insulated to the value noted in Table 5-12. (R-3.6 for <= 2 pipe, R-5.4 for > 2 ) Combustion Air. Installation of a wood stove or other solid fuel combustion appliance in a basement must provide combustion air to the appliance. Chapter 2-4 WSEC Builder s Field Guide, 8th Edition, 2009 Washington State University Extension Energy Program

Figure 2-4 Slab Construction Perimeter Insulation WSEC Builder s Field Guide, 8th Edition, 2009 Washington State University Extension Energy Program Chapter 2-5

Figure 2-5 Slab-on-Grade Chapter 2-6 WSEC Builder s Field Guide, 8th Edition, 2009 Washington State University Extension Energy Program

Figure 2-6 Monolithic Slab-on-Grade Figure 2-7A Interior Insulation WSEC Builder s Field Guide, 8th Edition, 2009 Washington State University Extension Energy Program Chapter 2-7

Figure 2-7B Exterior Insulation Note: See Appendix F of the International Residential Code for membrane requirements in radon counties. Chapter 2-8 WSEC Builder s Field Guide, 8th Edition, 2009 Washington State University Extension Energy Program

Figure 2-8 Possible Slab Insulation Details WSEC Builder s Field Guide, 8th Edition, 2009 Washington State University Extension Energy Program Chapter 2-9

Figure 2-9 Non-Bearing Slab Thermal Break Chapter 2-10 WSEC Builder s Field Guide, 8th Edition, 2009 Washington State University Extension Energy Program

Basements Any basement with a heat source must have insulated walls. For a basement to be considered unheated and not require wall insulation, there must be no heat supplied. An unheated basement must be thermally isolated from adjoining conditioned spaces. This would include: Ceiling insulation (i.e. the floor above). Insulated stairwell walls. A weatherstripped access door. Insulated and sealed ducts and pipes. [502.1.4.10] Below-Grade Walls. For the purposes of the Code, wall sections that extend 24 inches or less above grade may be considered below-grade walls. Insulation: May be placed on either the interior or the exterior of the wall. The minimum required R-value is determined by the compliance path chosen. Exterior insulation must: Be approved for below-grade installation. Extend from the top of the below-grade wall to the top of the footing. Be protected where it extends above grade (see Figure 2-10). Interior insulation must: Extend from the top of the below-grade wall to the top of the below-grade floor (see Figure 2-11). WSEC Builder s Field Guide, 8th Edition, 2009 Washington State University Extension Energy Program Chapter 2-11

Daylight Basement. Pay attention to corner details when insulating a daylight basement (see Figures 2-12 and 2-13 for examples). Anywhere the slab in a daylight basement is within 24 inches of the finish grade, perimeter slab insulation is required. Note: Ducts and pipes in the slab and combustion air requirements are the same for heated basements as they are for slab-on-grade. Unheated basements require R-8 duct insulation. Any hot water pipes buried under a slab must be insulated to the value noted in Table 5-12. (R-3.6 for > 2 pipe, R-5.4 for >/= 2, see Notes on page 2-4). Chapter 2-12 WSEC Builder s Field Guide, 8th Edition, 2009 Washington State University Extension Energy Program

Figure 2-10 Heated Basement: Exterior Insulation ("Good Practice") WSEC Builder s Field Guide, 8th Edition, 2009 Washington State University Extension Energy Program Chapter 2-13

Figure 2-11 Heated Basement: Interior Insulation ("Good Practice") Chapter 2-14 WSEC Builder s Field Guide, 8th Edition, 2009 Washington State University Extension Energy Program

Figure 2-12 Heated Daylight Basement: Exterior Insulation WSEC Builder s Field Guide, 8th Edition, 2009 Washington State University Extension Energy Program Chapter 2-15

Figure 2-13 Heated Daylight Basement: Interior Insulation Chapter 2-16 WSEC Builder s Field Guide, 8th Edition, 2009 Washington State University Extension Energy Program