VEGA System. PS Knee Replacement Technology. Aesculap Orthopaedics



Similar documents
How To Improve Metal Ion Release From An Implant

High-Flex Solutions for the MIS Era. Zimmer Unicompartmental High Flex Knee System

Aesculap Spine activ L

VERILAST Technology for Hip Replacement Implants

Zimmer FuZion Instruments. Surgical Technique (Beta Version)

Degenerative Spine Solutions

Oxford Partial Knee. A Definitive Implant. Tibial Component. Anatomical shape for optimal bone coverage

Acetabular Wedge Augment System

INSTRUCTIONS FOR USING THE KNEE SOCIETY RADIOGRAPHIC EVALUATION FORM

Why an Exactech Hip is Right for You

Affected Product: Polyethylene Implants from Gender Solutions Natural-Knee Flex, Natural-Knee, Natural-Knee II, MOST Options, and Apollo Systems

The information contained in this document is intended for healthcare professionals only.

on-metal Hips: Device Mechanics and Failure Modes

Custom Design of Knee Joint Prosthesis By Using Computerized Tomography (CT) Images and 3D Modelling

The patellofemoral joint and the total knee replacement

Posterior Referencing. Surgical Technique

MIN Set. Instruments for Minimally Invasive Neurosurgery. Aesculap Neurosurgery

Aesculap Service Systems instacount PLUS. The new standard in instrument management

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE. Health Technology Appraisal

Zimmer Gender Solutions NexGen High-Flex Implants


Total Hip Joint Replacement. A Patient s Guide

Zimmer Persona Adverse Events Reported to FDA Through 3/27/2015

The Right Choice. Exeter. total hip system

Knee Kinematics and Kinetics

Aesculap Spine activ C

Aesculap Orthopaedics Metha

BONE PRESERVATION STEM

ADVANCE. Medial-Pivot and Stemmed Medial-Pivot Knee Systems

Hip Resurfacing 2011 ORIGINAL ARTICLE. James W. Pritchett MD. Introduction. Abstract

frequently asked questions Knee and Hip Joint Replacement Technology

Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology

Implant materials. Learning outcomes. Implant materials in trauma. How to use this handout? Functions of implants. Types of materials

it s time for rubber to meet the road

Trabecular Metal Femoral Component. Surgical Technique

Clinically Proven Fiber Metal Material. Power to choose advanced bearing technologies to match patient demands

Corporate Medical Policy Computer Assisted Surgical Navigational Orthopedic Procedures


Metal-on-Metal Hip Systems

Computer Aided Engineering (CAE) Techniques Applied To Hip Implant

Technique Guide. VersiTomic. Michael A. Rauh, MD. Anterior Cruciate Ligament Reconstruction

User Guide. Customized Patient Instrumentation Web Based Surgical Planning and Tracking Software Guide

Simplified surgery. Personalized performance.

Open and Endoscopic Forehead Lift. Plastic Surgery. For All Brow and Forehead Lift Procedures. Revolutionizing. Soft-Tissue Fixation

ReCap Product Rationale

Product overview and surgical technique

Biomechanics of Knee Replacement. Ryan Keyfitz Rohinton Richard

Y O U R S U R G E O N S. choice of. implants F O R Y O U R S U R G E R Y

How To Fix A Radial Head Plate

TOTAL HIP REPLACEMENT FOR A LIFETIME: THE CEMENTLESS METAL ON METAL RECONSTRUCTION

Know-how brings motion back to life. SM. Solution UC-PLUS. Unicompartmental Knee Prosthesis. Surgical Technique

Biomechanics of Joints, Ligaments and Tendons.

Corporate Brochure. Aesculap, Inc. Aesculap Implant Systems, LLC

Malrotation Causing Patellofemoral Complications After Total Knee Arthroplasty

Minimally Invasive Hip Replacement through the Direct Lateral Approach

Full HD Visual System

The Total Ankle Replacement

.org. Arthritis of the Hand. Description

Howell ACL System. Howell 65 Tibial Guide EZLoc Femoral Fixation Device WasherLoc Tibial Fixation Device Graft Choice

Rotational alignment of the femoral component in total knee arthroplasty

NEXGEN COMPLETE KNEE SOLUTION. Epicondylar Instrumentation Surgical Technique For Legacy Posterior Stabilized Knees

Foot and Ankle Technique Guide Proximal Inter-Phalangeal (PIP) Fusion

Taperloc Complete Hip System

Achilles Tendon Repair, Operative Technique

Accolade. System. Brochure. Achieving Perfect Balance. Cemented and Cementless Femoral Hip System

1. Photon Beam Damage and Charging at Solid Surfaces John H. Thomas III

Total Knee Replacement Surgery

Your Practice Online

SALVATION. Fusion Bolts and Beams SURGICAL TECHNIQUE

PERIPROSTHETIC IMPLANTS

Zimmer PSI Knee System For Use with Persona The Personalized Knee System Surgical Technique

Modular Dual Mobility Acetabular Components: An Important Extension of a Proven Approach to Hip Instability

INTRODUCTION Cerclage Cable Vs. Monofilament Wire

Metallurgical analysis of five failed cast cobalt-chromium-molybdenum alloy hip prostheses

ADVANCE. Knee System Family. Medial-Pivot Kinematics. Sound Clinical History. Superior Instrumentation.

Failure Mechanisms and Closed Reduction of a Constrained Tripolar Acetabular Liner

ACCOLADE II. Orthopaedics. Femoral Hip System. Surgical Technique

Metasul LDH Large Diameter Head

HUNTER TENDON IMPLANTS

HEADER TOTAL HIP REPLACEMENT SURGERY FROM PREPARATION TO RECOVERY

The measuring of the hardness

Imagine being an orthopedic surgeon and knowing that your patient s

QUESTION I HAVE BEEN ASKED TO REHAB GRADE II AND III MCL INJURIES DIFFERENTLY BY DIFFERENT SURGEONS IN THE FIRST 6WEEKS FOLLOWING INJURY.

Design surgeon list. Smith & Nephew thanks the following surgeons for their participation as part of the R3 system design team:

EMPLOYMENT: PEACHTREE ORTHOPAEDIC CLINIC ATLANTA- GA PRESENT Orthopaedic Surgeon Northside Hospital, Atlanta, GA

Answers to commonly asked questions from patients with metal-on-metal hip replacements / resurfacings. Contents

Evaluating Knee Pain

Aesculap Spine activ L

How To Make An Implant From A Metal That Is Like Bone

Understanding Total Hip Replacement

Spinal Arthrodesis Group Exercises

Technology Breakthrough in Spinal Implants (Technical Insights)

VERSYS HERITAGE CDH HIP PROSTHESIS. Surgical Technique for CDH Hip Arthroplasty

Cable System. For Orthopaedic Trauma Surgery.

Anteromedial ACL Reconstruction Surgical Technique for Soft Tissue Grafts

Transcription:

VEGA System PS Knee Replacement Technology Aesculap Orthopaedics

A pivotal breakthrough in knee replacement. VEGA System PS Knee Replacement Technology Based on a patent-pending post-cam design that optimizes pivotal motion while greatly reducing surface stress, the VEGA System represents a whole new way to think about PS knee replacement. The VEGA System s groundbreaking design concept works hand in hand with a unique 7-layer Advanced Surface (AS) coating, delivering exceptional kinematics, reduced wear rates, and excellent jump distances. Aesculap Implant Systems aims to provide Innovations for Better Patient Outcomes. The all-new VEGA System was designed with equal emphasis on surgical efficiency and long-term performance.

Patent-Pending Post-Cam Design Designed to mimic natural knee kinematics by enabling a physiological pivot around the medial condyle, the VEGA System s distinctive post-cam design facilitates a large range of motion and optimized surface contact between the femoral and gliding surfaces. The surface contact between the articulating components maximizes bearing surface stress distribution, reducing the risk of delamination. n Enables pivotal motion, helps avoid excessive loading on posterior condyle edges, and reduces stress on bearing surfaces Unique Post-Cam Design: Enables pivotal motion while reducing bearing surface stress. n n Dorsal fin polyethylene post and cam interactivity reconstructs natural knee kinematics Posterior inclination of the polyethylene post design prevents anterior impingement with the extensor mechanism and increases resistance to dislocation Deepened anterior cutout facilitates smooth articulation of the patellar tendon In combination with unique cam engineering, allows for rollback and a pivot motion around the medial condyles that greatly mimics natural knee kinematics Soft-tissue-friendly: Anterior and posterior narrowing combined with minimal box resection minimizes interference with surrounding soft tissues Dorsal Fin Polyethylene Post: Facilitates a smooth gliding surface and reduces dislocation risks. Excellent Jump Distances In conjunction with the height and inclination of the polyethylene post, the design of the VEGA System s post-cam mechanism results in excellent jump distances, which increase with flexion and can reduce subluxation risks. 25 0 45 60 90 120 145 160 Posterior femoral condyle and polyethylene articulation at varying degrees of flexion. The VEGA System's unique design of these articulating surfaces facilitates natural kinematics and prevents posterior condyle floating. Jump Distance (mm) 20 15 10 5 12 17.5 20 20 0 45 90 145 160 Flexion Angle

Unique 7-Layer AS Coating Imagine a surface coating that delivers unparalleled surface hardness, substantially decreased wear rate, and greatly improved scratch resistance. Now imagine the performance of a unique 7-layer Advanced Surface (AS) coating. Unmatched Surface Hardness Small scratches in CoCrMo implants are common and can lead to surface damage and higher PE wear. Conversely, the AS coating s zirconium nitride top surface layer yields unmatched surface hardness: 1-6 n Improved scratch resistance Innovative 7-layer AS coating brings leading-edge technology to knee replacement. n Excellent wettability n Better articulation between bearing surfaces n Minimizes mechanical ablation risk 7 n No damage after extreme wear test with bone chips and cement particles: 60% Wear Rate Reduction Wear is the number-one reason for long-term knee replacement revisions. 8 To combat this issue, the AS coating can deliver up to a 60% reduction in wear when compared to a CoCr prosthesis, as demonstrated 9, 10 in testing with other Aesculap knee designs. Wear rate (mg/mc) Inside Articulation t Outside Articulation Wear Rate (mg/mc) Wear reduction with AS coating on a Columbus Knee design after 5 Mio cycles according to ISO 7, 9, 10 Standard 14243-1/3 8.3 58% CoCr AS Coating 3.5 Wear simulation under extreme conditions 7

Exceptional Mechanical Integrity A hard surface on top of a relatively soft base material (CoCr) can lead to a higher risk of surface breakage (eggshell effect). The AS coating is designed to reduce hardness from top to bottom in a gradient-like fashion, resulting in an improved elastic modulus. This makes it extremely stable against mechanical stresses and strains. 11 The transition zone within the AS coating compensates for changes in surface hardness and results in a more resilient product. A powerful bonding layer between the base material and subsequent layers forms an alloy compound that ensures strong adhesion. Hardness Gradient Monolayer Coating Column structure of crystallines 7-Layer AS Coating: Improved Elastic Modulus Small grain sizes Reduced Metal Ion Release With the AS coating, metal ion concentration is near the level of detection and below any biological threshold. 7 Beta Radiation Sterilization All of Aesculap s polyethylenes are sterilized under Beta radiation, which reduces oxidation, decelerates the aging process, and yields better wear rates. 12 1 medthin.com. Coating Portfolio. 30.3.2011. 2 TiNbN & TiN dot-coating.de/dotimplantsource/beschichtung.html. 30.3.2011. 3 Biolox Delta: BIOLOX delta Noverbundwerkstoff für die Endoprothetik, Ceramtec 07/10. 4 Smith & Nephew: OXINIUM : Made for Life Image Brochure. 5 Zimmer PM Newsletter 11/2006. 6 Aesculap data on file. 7 Reich J, Hovy L, Lindenmaier HL, Zeller R, Schwiesau J, Thomas P, Grupp TM. Präklinische Ergebnisse beschichteter Knieimplantate für Allergiker. Orthopäde.2010 Mai;39(5):495-502. 8 Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM. Insall Award paper. Why are total knee arthroplasties failing today? Clin Orthop Relat Res. 2002 Nov;(404):7-13. 9 Affatato S, Spinelli M, Lopomo N, Grupp TM, Marcacci M, Toni A. Can the method of fixation influence the wear behaviour of ZrN coated unicompartmental mobile knee prostheses? Clin Biomech (Bristol, Avon). 2011 Feb; 26(2): 152-8. Epub 2010 Oct 8. 10 Grupp TM, Schwiesau T. Determination of the wear behaviour of the UNIVATION mobile knee system T018, Mar 2007. 11 Santana AE. Relating hardness-curve shapes with deformation mechanisms in TiAlN thin films indentation. Materials Science and Engineering A 406(2005) 11-18. 12 Bell CJ, Walker PS, Abeysundera MR, Simmons JM, King PM, Blunn GW. Effect of oxidation of delamination of ultrahighmolecular-weight polyethylene tibial components. J Arthroplasty 1998 Apr;13(3):280-90.

Innovation that moves you. Quick, Intuitive Instrumentation The VEGA System s IQ Instrumentation platform is highly intuitive, with dual-purpose instruments, fewer trays, and a simplistic design that allows surgeons to operate quickly and easily resize. Reduce steps in your workflow and save time and money. The IQ Instrumentation platform is simple, efficient, and designed to save time. Award-Winning Navigation Aesculap s award-winning OrthoPilot Navigation System enables excellent implant alignment without the need for CT/MRI scans. Combine the VEGA System with OrthoPilot, and you ve got today s fastest, most versatile, most efficient navigated PS knee replacement system at your fingertips. The OrthoPilot Navigation System enhances surgical workflow and helps achieve optimal implant alignment.

Better Bone Fit 13 femoral sizes, including standard and narrow design, and 11 tibial sizes, including standard and AP+ sizes, offer a wide range of soft-tissue-friendly implants for a better bone fit regardless of gender, size, morphotype, or race. Additionally, the VEGA System s low-profile box helps preserve more bone. You need a knee replacement system that moves you quickly through your workflow and delivers accurate, efficient operation. Your patients need a knee replacement system that delivers lasting mobility. You both need the VEGA System. Visit aesculapimplantsystems.com/vega today and see where the VEGA System can take you.

All rights reserved. Technical alterations are possible. This leaflet may be used for no other purposes than offering, buying and selling of our products. No part may be copied or reproduced in any form. In the case of misuse we retain the right to recall our catalogs and price lists and to take legal actions. 2012 aesculap. all rights reserved. printed in the usa. Aesculap is an equal opportunity employer. Aesculap Implant Systems, LLC I 3773 Corporate Parkway I Center Valley, PA I 18034 Phone 866-229-3002 I Fax 610-984-9096 I www.aesculapimplantsystems.com Aesculap Implant Systems, LLC - a B. Braun company DOC1027 1M 05/12