326 PEDIATRIC DENTISTRY: SEPTEMBER/OCTOBER, 1992 ~ VOLUME 14, NUMBER 5



Similar documents
Detergents in CSSD. Wim Renders

STERILIZATION د STERILIZATION

Infection Control in the Dental Practice through Proper Sterilization

Condylar position in children with functional posterior crossbites: before and after crossbite correction*

BioSonic Ultrasonic Cleaning System. Ultrasonic Cleaning highly effective reaches into minute crevices instruments stay sharp and in shape

Dental Office P2 WRPPN 2005

Air. Air and light. Light

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

A new wave in instrument washing and disinfection Introducing the new HYDRIM G4 WD series

Ultrasonic cleaning technology and cleaning chemicals

KEYWORDS: EARLY CHILDHOOD CARIES, POST-DOCTORAL TEACHING

Taylor Dental Assisting School Course Description

Eliminating effect of Er, Cr: YSGG laser irradiation on the smear layer of dentin

KODAK Developer System Cleaner and Neutralizer

WMI Mutual Insurance Company

Nu G Medical Waste System Technology (Pyrolysis / Thermal Decomposition)

Thermo Scientific Rotor Care Guide. Protect your rotor investment

ARTICLE DENTAL ASSISTANTS CHAPTER DUTIES

The U.S. Surgeon General has identified children

Job Ready Assessment Blueprint. Dental Assisting. Test Code: 4026 / Version: 01

ADA Standards Committee on Dental Products National Standards Status of Projects. Standard # Title of Standard WG Status Activity

Surface Engineering Solutions Rebuild, Repair and Protect Industrial Equipment

Best Management Practices For Dental Office Waste

Guide on the Segregation, Packaging, Labelling and Storage of Laboratory Chemical Wastes for Schools

All Purpose Cleaner. Carpet Care. Specialty Cleaner

Waste and Cost Reduction Techniques for Small Parts Cleaners

Provide chairside support during the extraction of teeth and minor oral surgery

THE BASICS OF DECONTAMINATION

Oxivir Tb and Accelerated Hydrogen Peroxide (AHP) Frequently Asked Questions

Profiles for floors of same height Cerfix Projoint

CENTRAL COUNTY REGIONAL OCCUPATIONAL PROGRAM SANTA ANA UNIFIED SCHOOL DISTRICT COURSE OUTLINE DENTAL ASSISTANT/CHAIRSIDE I

Nickel Free Room Temperature Seal: an innovative and ecological process

Clinical Study Report. Clinical Efficacy of the e-bright Tooth Whitening Accelerator Home Edition: a randomized placebo controlled clinical trial

Chart 1. Chart 2. How to Use the Following Charts. Be sure to follow the legal requirements to perform dental radiographic procedures.

book Seite 1 Freitag, 22. Juni : qn=ifkb=l=qo=ifkb. Operating Instructions. båöäáëü. lééê~íáåö=áåëíêìåíáçåë

Conducting a Job Hazard Assessment. Environmental, Health and Safety

APPLICATION OF PHOTOGRAPHY IN DENTAL PRACTICE

BIOACTIVE COATINGS ON 316L STAINLESS STEEL IMPLANTS

qn=ifkb=l=qo=ifkb=l=qp=ifkb

Oral Health Workforce for Low Income Children

Rochester Regional Health. Dental Plan

Methods of Verification of Cleaning in CSSD. Dr. Winfried Michels Mechelen Oct.2012

Dr. Little received his doctorate degree in dentistry from UT Health at San Antonio Dental

Cleaning Guidelines for Care Homes. Includes cleaning standards for the general environment and equipment

Metal Rescue Rust Remover Technical Data

Role of dentistry in the health scciences, the dental team. Dr. Dézsi Anna Júlia

Summary of Benefits. Mount Holyoke College

What Dental Implants Can Do For You!

Body Art Facility Infection Prevention And Control Plan Guideline

Expert Opinion. on the efficacy of. EndoDet and EndoDis + EndoAct. for cleaning and disinfection of. Olympus Gastroscope Type GIF-2T200.

A Comprehensive Explanation

Instruction Manual. Ultrasonic Cleaning Tank. Advanced Ceramics Technology (M) Sdn. Bhd A Crest Group Inc. Company

SOUTH CAROLINA. Downloaded January 2011

BID RESULTS AB DENTAL SERVICES FOR THE MERCER COUNTY CORRECTION CENTER OPENED JUNE 12, WEST STATE STREET

Cleaning of Oval Canals Using Ultrasonic or Sonic Instrumentation

CLEANING AND SANITIZING

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

[PAGE HEADLINE] Improve your Health and Change Your Smile with Complete Dental Services in One [CITYNAME] Location

BRIDGE FIELD PAINTING, REPAINTING, 412 AND PAINT RESIDUE CONTAINMENT. A. Field Painting, Bridge Repainting and Residue Containment:

TDLR. TDLR Rules and Regulations Power Point. TDLR Laws and Rules Book

Guidelines for Selecting and Maintaining Glycol Based Heat Transfer Fluids

RESIDENT TRAINING GOALS AND OBJECTIVES STATEMENTS

Complications Associated with Tooth Extraction

Dentalworkers JOB DESCRIPTIONS Great Team Members make your Office function!

ENDO REMOVAL SYSTEM Set of endodontic micro instruments for removing broken canal instruments

Indications for Use: Contraindications: Benefits of Ultrasonics: Disadvantages: Some handpieces cannot be sterilized Portability Evacuation needed

Surface Treatment of Titanium

Are You Always Ready for The Joint Commission or CMS Survey?

Water Heater Dip Tubes-Why all the Fuss?

Improved Broaching Steel Technology

According to the 2000 U.S. surgeon general s

Many roads lead to a perfect impression...

Clinic Washer-Disinfectors. Washer-Disinfector Line

RomiApex A-15. APEX LOCATOR User Manual

OREGON BOARD OF DENTISTRY BOARD APPROVED COURSE IN PLACEMENT OF PIT AND FISSURE SEALANTS

Process Control For Phosphate Coating A new military specification for phosphate coatings...

Arrangements for the Maintenance and Testing of Laboratory Autoclaves

HEALTHCARE IN WASHINGTON STATE. Environmental Compliance

PART 1 - INTRODUCTION...

Dental care and treatment for patients with head and neck cancer. Department of Restorative Dentistry Information for patients

Dental Careers I, August 2013, Page 1 of 6

NDT Procedure for Liquid Penetrant Inspection TRINITY NDT. An ISO 9001:2008 Certified Company

BESTPRACTICE. HTM01-05 Q&A: You can now follow us on Twitter! We have launched our HTM01-05 questions and answers service on Twitter.

Endo Easy Efficient Sonic Powered Endo Irrigation

GUIDELINES FOR THE CLEANING UP OF BODILY FLUIDS

Influence of CO2 Bubbling (Carbonation) During Semiconductor Wafer Sawing Process. KP Yan, Reinhold Gaertner, KK Ng

33 Infection Control Techniques

Scanning Electron Microscopy Services for Pharmaceutical Manufacturers

Dental caries is an infectious disease caused

More to feel good about. Baltimore City Public Schools Dental Options

Environmental Management of Staph and MRSA in Community Settings July 2008

BlueCare Dental SM 1B OUTLINE OF COVERAGE

DENTAL FOR EVERYONE SUMMARY OF BENEFITS, LIMITATIONS AND EXCLUSIONS

Ultrasonic support removal tank

AUTOCLAVE CORROSION INHIBITOR EVALUATION

AUSTENITIC STAINLESS DAMASCENE STEEL

Site Visit Report. MEAT PROCESSING FACILITY COD Reduction. Industrial Assistance Section Assessment Team

COURSE 1020 OIL ANALYSIS WHY ATTEND

HOW THE IMR FINAL DETERMINATION WAS MADE

Transcription:

Comparison of two ultrasonic cleaning units for deterioration of cutting edges and debris removal on dental burs Alejandra Villasen6r, DE)S, MS Sharon D. Hill, DDS, MS N. Sue Seale, DDS, MSD Abstract The effects of two ultrasonic cleaning units on surface deterioration and cleaning effectiveness of dental burs were compared in this study. The units tested were the Dextrex ~ Model L 503B (Dextrex Chemical Industries, Inc., Bowling Green, KY) industrial ultrasonic unit and a conventional dental ultrasonic unit & R T-21 B (L & R Manufacturing Co., Kearny, NJ). SEM photomicrographs of the burs were made before cleaning, and burs were processed for 10 min in each unit. Forty-eight new burs (24 #1/2A diamond and 24 #330 carbide) contaminated with human blood and 48 burs contaminated with tooth debris following cavity preparation were used to evaluate cleanliness. To assess deterioration, 48 new burs were evaluated for changes in the number of diamond chips or pits (carbide burs) and color changes following ultrasonic cleaning. Neither unit sufficiently cleaned the burs, as evidenced by remnants of remaining blood and debris on the burs. The loss of diamond chips was statistically significant for the burs processed in the Dextrex unit (P < 0.001) as well as for burs processed in the L & R T 21-B unit (P < 0.01). The mean number of pits was significant in carbide burs processed in both units as well (Dextrex unit: P < 0.01; L & R T-21 B unit: P < 0.001). No differences were noted in color changes for any of the burs in either unit. These data showed that the industrial-type unit was no more effective in cleaning dental burs than the conventional unit, though both units caused significant amounts of deterioration in the cutting surfaces. (Pediatr Dent 14: 326-30, 1992) Introduction The danger of cross contamination between patients has made effective cleaning and sterilization regimens mandatory for all instruments which are to be reused. 1-6 To achieve sterilization, it is crucial that instruments first be cleaned well. Manual cleaning of instruments before sterilization presents a problem in that it adds to the risk of infection to the personnel cleaning them. Further, even after thorough cleaning and rinsing, debris still may be present on the instruments. Therefore, ultrasonic cleaning is the recommended procedure before sterilization. Not only is this method safer for the personnel involved, but ultrasonic cleaning of instruments has been shown to remove debris more effectively than hand cleaning. 7 Ultrasonic cleaning also can be performed more efficiently -- in one fifth of the time it would take to hand clean the same instruments. 8 In a study of eight commercial ultrasonic dental units, it was concluded that all the units were effective for 9 both presterilization and routine cleaning. In evaluating ultrasonic units, other factors besides cleaning ability must be considered. One of these factors is the chemical aggressiveness and effects from the disinfecting and sterilizing solutions on instrument surfaces. These solutions contain chemically active ingredients such as phenols, glutaraldehyde, benzalkonium chloride, phosphoric acid, and borates, each of which is a potential corrosive agent for dental burs and similar dental instruments. 10 Careful consideration should be given to the potentially damaging effects of ultrasonic cleaning units and solutions on the cutting efficiency of these instruments. Reports vary as to whether dental burs are damaged by ultrasonic cleaning. Hooker and Staffanou showed a negligible weight loss of diamond burs following ultrasonic cleaning and concluded that there were no deleterious effects. 4 However, damaging effects on carbide dental burs following ultrasonic cleaning have been shown by Patterson et al. 6 Extensive pitting and loss of structural integrity at the carbide/ steel interface were observed after 40 test cycles of 5 min each. Another factor which should be evaluated is the type of unit which is the most effective for cleaning dental instruments. At present, there does not appear to be substantial evidence to recommend one type of unit over another. Industrial ultrasonic units are gaining popularity for use in hospitals due to their increased load capacity, and because the lower frequency at which they operate is believed to render better cleaning. While the study by Eames et al. showed effective cleaning of certain dental materials, an earlier study by McKay showed that tissue fragments remained on surgical instruments following hospital ultrasonic cleaning with a detergent solution. 9, 11 Perkins also indicated that even though ultrasonic cleaning is more efficient than hand cleaning, the quality of cleaning with hospital ultrasonic units is erratic.12 The effect which these units have on deterioration has not been reported. The purpose of this study was to compare debris removal and deterioration of cutting edges of dental burs following ultrasonic cleaning using a conventional 326 PEDIATRIC DENTISTRY: SEPTEMBER/OCTOBER, 1992 ~ VOLUME 14, NUMBER 5

dental ultrasonic cleaning unit and an industrial (hospital) type unit. Materials and Methods The ultrasonic units tested were the Dextrex Model L 503 B (Dextrex Chemical Industries, Inc., Bowling Green, KY) industrial ultrasonic unit and the conventional dental ultrasonic unit L & R T-21 B (L & Manufacturing Co., Kearny, NJ). The study consisted of observations and measurements of a total of 144 burs: 72 #330-FG carbide pear-shaped burs (Midwest Dental Products Corp., Des Plaines, IL), and 72 #1/2A-X FG/ 230C diamond flame-shaped burs (Teledyne Densco, Denver, CO). All burs were examined for: 1) cleanliness of the cutting portion of the burs; 2) deterioration of the cutting edge or surface of the burs; and 3) color changes as another indicator of deterioration. The burs were divided randomly into two groups: Group A was assigned to the Dextrex Model L 503 B and Group B was assigned to the L & R T-21 B. Each group consisted of 36 #330 carbide burs and 36 #1/2A Cable 1. Subgroups diamond burs. The groups were divided further into subgroups: subgroup 1 consisted of burs to be N 12/12 evaluated for cleanliness; Total 24 subgroup 2 consisted of burs to be evaluated for A = Dextrex unit; B = L & R T 21-B unit. deterioration. (Table 1) Both units contained the same detergent solution, Instru- Klenz TM (Calgon Vestal Laboratories, St. Louis, MO) diluted to one ounce of detergent per gallon of water, according to manufacturer s instructions, and kept in the range of 100 to 107 F for all tests. Cleanliness Twelve new diamond and 12 new carbide burs were contaminated for each subgroup to be evaluated for cleanliness. Three diamond and three carbide burs from each subgroup were photographed (Kodachrome TM 35 film/100 ASA, Eastman Kodak Co., Rochester, NY) after contamination using a dissecting microscope (Wild Heerbrugg TYP 376788, Wild Heerbrugg LTD., Heerbrugg, Switzerland) to establish a baseline record of uncleaned burs. Only six burs from each subgroup were photographed for baseline records, since no distinguishable differences could be observed between contaminated burs in a pilot study conducted by the authors. All burs were photographed at the same working distance. Burs were contaminated by dipping in human blood or by cutting cavity preparations in extracted teeth. The diamond burs were used to cut stainless steel crown preparations; the carbide burs were used to cut Class I amalgam preparations. Tooth preparation was accomplished using a high-speed handpiece with continuous water spray and was limited to 3 min with each bur. All contaminated burs were air dried for 20 min before ultrasonic processing. The 24 burs in each subgroup were processed for 10 min in each unit. Immediately after processing, each bur was examined under the dissecting microscope at 40x (carbide) and 25x (diamond). The criteria for the demonstration of changes were the presence of debris, and the total absence of debris. Deterioration Each diamond and carbide bur was marked on the shaft with an identification number, and another mark also was placed on the shaft for orientation durinj~ photographing. ~ Each bur was photographed (Polaroid Type 55) under the JEOL 35CF Scanning Electron Microscope (SEM, JEOL -- USA, Inc., Peabody, MA)o Magnification was at 32x for diamond burs and 54x for Subgroup A1 Blood B1 Brood A1 Tooth B1 Tooth A2 Deterioration B2 Deterioration Bur type Dia/Car Dia/Car Dia/Car Dia/Car Dia/Car Dia/Car 12/12 12/12 12/12 12/12 12/12 24 24 24 24 24 the carbide burs, both at 20 Kv. Quantification of diamond chips (diamond burs) and pits (carbide burs) accomplished by using the method described by Bromley et al. 13 The number of diamond chips or pits/ cm 2 was determined by overlaying an acetate grid over 8 x 10 enlargements of the SEM photomicrographs. Counts were made three times on each print and a mean was established which was used to calculate the percentage of chips or pits. Pretreatment quantification of diamond chips and pits per surface served as the control for this group of burs. All the burs in this group were sonicated for 10 cycles of 10 min each, in each unit. The amount of diamond chips and pits between pretreatment and post-treatment was compared. The degree of cavitation in the shaft/cutting portion interface was evaluated as follows: a) no cavitation, b) isolated area(s) of cavitation, c) area of cavitation around the entire neck of the bur and, d) total fracture of the cutting portion from the shaft. Since a color change in the metal also may indicate deterioration, these same diamond and carbide burs were photographed using the dissecting microscope at 40x. These photomicrographs were taken before and after ultrasound cleaning, and compared for evaluation PEDIATRIC DENTISTRY: SEPTEMBER/OCTOBER, 1992 N VOLUME 14, NUMBER 5 327

of color changes. The criteria for the demonstration of color changes were as fol- Subgroup lows: a) no change; appears same as new instrument, and b) color change present. Cleanliness Bur type Head/shank Data for burs with debris remaining after 10 min of ultrasonic processing in both units are summarized in Table 2. Blood and tooth debris was present in the shank portion of all of the diamond burs processed in both units. Less debris was observed in the head portion of the burs, and only one diamond bur had blood remaining in the head after processing in the L & R T-21 B unit. Debris remained in the head and shank portions of all the carbide burs, regardless of the unit in which they were processed. Deterioration The data for the amount of deterioration which was observed are summarized in Table 3. A loss in the mean number of diamond chips and an increase in the number of pits (cavitations) in the carbide burs after cycles of ultrasonic processing was noted in both units. The loss of diamond chips was statistically significant (P < 0.001) for the group treated in the Dextrex unit, well as for the group treated in the L & R T-21 B unit (P < 0.01). The percentage of cutting surface covered by diamond chips before treatment in the Dextrex unit was 55%. After treatment, only 43% of the surface was covered by diamond chips. Of those processed in the L & R T-21 B unit, 51% of the surface was covered before treatment, and 46% was covered after ultrasonic processing. There were no significant differences in diamond chips lost between the two units. The increase in the number of cavitations in the carbide burs after processing was statistically significant for the group treated in the Dextrex unit (P < 0.01) and for those treated in the L & R T-21 B unit (P < 0.001). The carbide burs processed in the Dextrex unit were cavitated on 29% of the cutting portion before treatment, and on 39% of the surface post-treatment. For the Table 2. Burs with debris (blood and tooth) after ultrasonic processing A1 Blood A1 Tooth B1 Blood B1 Tooth Dia Car Dia Car Dia Car Dia Car H/S H/S H/S H/S H/S H/S H/S H/S Burs with debris 9 12 12 12 12 12 12 12 1 12 12 12 7 12 12 12 Statistical Analysis Descriptive statistics were Total of 12 diamond (dia) and 12 carbide (car) burs in each subgroup. A = Dextrex unit; B = L & R T 21-B unit. used to evaluate the outcomes of cleanliness and color change. A t-test for Table 3. Number of diamond chips (diamond burs) independent samples was performed to test the differences between the mean number of diamond chips and and cavitations (carbide burs) before and after ultrasonic processing pits before and after treatment, and to test differences between the two units. To evaluate the degree of cavitation at the level of the carbide/steel interface, a Wilcoxon Unit Dextrex L & RT-21B Pre Post Pre Post Match-Pairs signed rank test was performed. Results Diamond chips Mean 111.2 87.6 106.6 91.8 SD 11.6 13.9 9.4 8.1 Cavitations Mean 25.6 35.5 24.5 39.0 SD 10.2 7.9 11.0 8.5 carbide burs processed in the L & R T-21 B unit, 29% of the cutting portion of the surface was cavitated pretreatment, and 43% of the surface was cavitated after ultrasonic processing. A t-test analysis to compare the mean number of diamond chips and the mean number of pits before treatment for the burs tested in the two ultrasonic units showed no significant difference between the number of diamond chips or pits in the burs assigned to the Dextrex unit and those assigned to the L & R T-21 B unit. A significant difference (P < 0.05) in the amount cavitation at the carbide/steel interface was noted between pre- and post-treatment carbid~e burs (Figure, page 329). Of the carbide burs processed in the Dextrex unit, nine pretreatment burs were free of cavitation at the tungsten/carbide-steel interface and three had isolated areas of cavitation. Post-treatment, seven of the nine unaffected pretreatment burs presented isolated areas of cavitation. In the untreated group of 12 carbide burs processed in the L & R T-21 B unit, seven burs appeared free of cavitation at the neck and five had isolated areas of cavitation at the neck. After treatment, all seven unaffected burs presented isolated areas of cavitation. The remaining five burs did not appear to have any increased cavitation at the level of the neck. The pre- and post-treatment differences were statistically significant (P < 0.05), though there were no significant differences in the amount of cavitation produced by the different units. 328 PEDIATRIC DENTISTRY: SEPTEMBER/OCTOBER, 1992 ~ VOLUME 14, NUMBER 5

Figure. SEM photomicrographs of a #330 carbide bur showing cavitation (arrows) at the carbide/steel interface following 10 cycles of 10 min each in the Dextrex model 503B unit(54x) and a #330 carbide bur before ultrasonic processing showing no cavitations at the carbide/steel interface (54x). Color Changes No color changes were apparent in the carbide burs prior to treatment. Among the 12 burs processed in the Dextrex unit only two had color changes present. The same observation was made for the carbide burs assigned to the L & R T-21 B unit i.e., only two presented any color changes. No color changes were observed in the diamond burs. Discussion The necessity for effective cleaning procedures in the dental office, laboratories, and hospitals has encouraged the use of industrial ultrasonic cleaners in health care facilities. Reports on the cleaning effectiveness and deterioration caused by these large-capacity, lowerfrequency operating machines are limited, though some studies have determined that the cleaning effectiveness of the industrial type unit is ineffective, or at most erratic.^!' ^2 When an industrial ultrasonic cleaner, the Dextrex unit, and a conventional L & R T-21 B dental ultrasonic unit, were compared in the present study, neither was observed to clean contaminated dental burs effectively. While these results support the findings of the previous studies on industrial type units, the findings for the conventional type unit are contradictory to those from an earlier study in which several leading ultrasonic units were evaluated.^ In that study, the removal of dried blood from instruments was not difficult for any of the units tested. The differences in these findings may be attributed to variables (e.g., processing time, cleaning solutions, temperature, and instrument load). Previous studies have found that as the number of instruments to be cleaned increases, so does the amount of time to clean them.14 In addition to providing the highest degree of cleaning, it also is desirable that the amount of deterioration of the instruments being processed be kept to a minimum. Both units in the present study caused a significant amount of deterioration to diamond and carbide burs after 10 cycles of 10 min each. In a previous pilot study by the authors, three diamond and three carbide burs were processed during 10 cycles of 15 min each. We observed a significant degree of cavitation in the cutting portion and neck of the carbide burs, as well as color changes. The cavitations in the burs in the pilot study appeared more severe when compared to the findings of the present study. These differences may be due to the increased sonication time (150 min vs 100 min), or to the decrease in the number of burs treated at one time. Another repeated finding between the pilot study and the present study is the amount of cavitation at the level of the carbide/steel interface between preand post-treatment groups for the carbide burs processed in both units. While a greater degree of cavitation was once again observed in the pilot study, SEM analysis showed corrosion and cavitation over the soldered joint of these burs in both studies. Similar findings of extensive pitting and loss of structural integrity at the carbide/steel interface have been reported by Patterson et al. 6 The findings for deterioration of diamond burs after ultrasonic processing revealed a loss from 5 to 12% of the diamond chips after sonication. These results are somewhat different from those of Hooker and Staffanou, who found a negligible weight loss of diamond burs following ultrasonic cleaning and concluded that there were no deleterious effects."* An interesting finding in the present study is that the greatest loss of diamond chips was observed in the Dextrex unit. The differences between the two units were not significant, however. Color changes observed in the carbide burs as an indication of progressive deterioration and corrosion PEDIATRIC DENTISTRY: SEPTEMBER/OCTOBER, 1992 ~ VOLUME 14, NUMBER 5 329

were not very marked in the present study, though they were more apparent in the pilot study. The degree of color change may be affected by the processing time, number of instruments per cycle, and physical characteristics of the metals. Kotz and Purcell reported that ultrasound frequency waves produce an ionizing reaction 15 of the existing electrons in a metal substance. This leads to a photolytic reaction which causes changes in the tungsten/carbide light spectrum. In conclusion, the present study found that neither the conventional L & R T-21 B dental ultrasonic unit nor the industrial (hospital) type Dextrex ultrasonic unit were completely effective in cleaning blood and tooth debris from dental burs. Both units did, however, cause a significant degree of deterioration in the cutting portions of the burs. Further studies are needed to investigate the effects of other variables, such as processing time, cleaning solutions, temperature, and instrument load, which also may play important roles in the cleaning and deterioration effects associated with ultrasonic cleaning. Dr. Villase~or is attending faculty/staff, Department of Pediatric Dentistry, The Children s Hospital, Denver, CO. Dr. Hill is assistant professor and Dr. Seale is professor and chairman, Department of Pediatric Dentistry, Baylor College of Dentistry, Dallas, TX. Reprint requests should be sent to: Dr. Sharon D. Hill. Baylor College of Dentistry, Department of Pediatric Dentistry, 3302 Gaston Avenue, Dallas, TX 75246. 1. McLundie AC, Kennedy GDC, Stephen KW, Kennedy TF: Sterilisation in general dental practice. Br Dent J 124:214-18, 1968. 2. MacFarlane TW: Cross infection and sterilisation in dental practice. Br Dent J 141:213-18, 1976. 3. MacFarlane TW: Sterilization in general dental practice. J Dent 8:13-19, 1980. 4. Hooker JB, Staffanou RS: An evaluation of sterilization procedures of diamond cutting instruments. Tex Dent ~ 102:8-10, 1985. 5. Dowell TD: The problems of cross-infection in dentistry. Br Dent J 160:131-34, 1986. 6. Patterson CJ W, McLundie AC, Mackay AM: The effect of ultrasonic cleansing and autoclaving on tungsten carbide burs. Br DentJ 164:113-15, 1988. 7. Spolyar JL, Johnson CG, Head R, Porath L: Ultrasonic cold disinfection. J Clin Orthod 20:852-53, 1986. 8. Neal B: The ultrasonic cleaner. Dent Assist 38:20, 1969. 9. Eames WB, Bryington SQ, Suway NB: A comparison of eight ultrasonic cleaners. Oper Dent 5:118-24, 1980. 10. Bapna MS, Mueller HJ: Corrosion of dental burs in sterilizing and disinfecting solutions. J Prosthet Dent 59:503-11, 1988. 11. McKay JH: Ultrasonic energy in hospital cleaning. Scott Med J 5:209-12, 1960. 12. Perkins JJ: Principles and Methods of Sterilization in Health Sciences. 2nd ed. Springfield, IL: Thomas, 1969. 13. Bromley RG, Dockum NL, Arnold JS, Jee WSS: Quantitative histological study of human lumbar vertebrae. J Geronto121:537-43, 1966. 14. Clancy BM: Effectiveness of an ultrasonic device in the cleaning of periodontal instruments. Masters thesis, The University of Michigan, 1984. 15. Kotz JD, Purcell KF: Chemistry and Chemical Reactivity. New York: Saunders Publishing Co, 1987, pp 68-90. 330 PEDIATRIC DENTISTRY: SEPTEMBER/OCTOBER, 1992 ~ VOLUME 14, NUMBER 5