High-power ultrasound for dental practice and laboratory



Similar documents
Ultrasonic cleaning technology and cleaning chemicals

TICKOPUR STAMMOPUR. Special Agents Ultrasonic Cleaning and Disinfection. Te koop via Industry Handicraft Service Laboratory

BioSonic Ultrasonic Cleaning System. Ultrasonic Cleaning highly effective reaches into minute crevices instruments stay sharp and in shape

Clinic Washer-Disinfectors. Washer-Disinfector Line

ACO Cleaning principles for drainage

Detergents in CSSD. Wim Renders

RBS detergents for laboratories

UNITOR ULTRASONIC cleaning

Shaking Water Baths THERMOLAB

Vacuum drying oven for non-flammable solvents

Instruction Manual. Ultrasonic Cleaning Tank. Advanced Ceramics Technology (M) Sdn. Bhd A Crest Group Inc. Company

EcoCWave. The all-round talent for aqueous part cleaning.

PRETREATMENT TECHNICAL DATA SHEET WATER EMULSIFIABLE RUST PREVENTATIVE PRODUCT DESCRIPTION

clean and quiet dental

ORGANIC SAMPLE PREPARATION

DETERGENTS. Application Recommendations. Application/ Concerns. Recommended Detergent. Articles Cleaned/ Soil Removed. Cleaning Method.

Après Body Dryer for Wet, Shower and Bath Rooms Innovative, Energy Efficient, Safe, World Certified, Barrier Free Living and Independence

Digital inductive conductivity transmitter

The Owners Coated Coil, Cleaning and Maintenance Service Manual.

Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications

BF Series Sa S n u d p Fe i r l C t l e e r a n Installation Manual -1-

IMPORTANT INFORMATION

Profiles for floors of same height Cerfix Projoint

Extran detergents the perfect solution for cleaning your laboratory utensils

Support Cleaning Apparatus. Operation, Cleaning, & Safety Manual

Thermo Scientific Rotor Care Guide. Protect your rotor investment

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

associates Precision Cleaning Systems 3678 Bassett St., Santa Clara CA Phn: [ 408 ] Fax: [ 408 ] tony@tmasc.

Power consumption (kw)

CHEMICAL CLEANING UNIT Product number:

Ozone in Cooling Towers : Hygiene for us

Multiple flasks. Easy to adapt. Stuart range of heating blocks

Installation and Service Instructions. Neutralization System Part no Grünbeck part no

Laboratory- and sterilisation equipment HMC EUROPE

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

LABOKLAV. Autoclaves Made in Germany.

Cleaning instructions

Water Baths. with BioCote antimicrobial protection

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Introducing an All New Line of Cleaning Chemicals

The Most Powerful Bench-top Ultrasonic Cleaner POWERSONIC 400 Series

Sterilizers with extra class

Ultrasonic Cleaning Lines for Aerospace Applications

Incubator with mechanical convection

kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.

Benchtop Series Ultrasonic Cleaning Tanks Operations and Maintenance Instructions

AIR PUMPS & ACCESSORIES

Vacuum Tube Solar Water heater Non-pressure. User manual

Important Information

VistaScan Perio Plus Image plate scanner more time for patient care

RomiApex A-15. APEX LOCATOR User Manual

Ultrasonic support removal tank

GENERAL MAINTENANCE MANUAL

SERVICE MANUAL Order No.WH0911S001V0

INSTRUCTIONS Edition AC

SECTION IV-2 THE BASICS OF CLEANING MILKING EQUIPMENT

Classification of dental cements

Infection Control in the Dental Practice through Proper Sterilization

UNITOR VACUUM cleaners

Protocol for Disinfection of Cell Culture and Tissue Culture in Media:

Make your own glass jewellery, anyone can do it!

Maintenance and Cleaning Tips MULTICO

Material test chamber with mechanical convection

UV Disinfection Systems A Series. Main Applications: Drinking Water, Process Water, Warm Water / Legionellae. IT T Industries Engineered for life

RO / NF Cleaning Guidelines

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Curved Quadrant Instruction Manual

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Western Blotting For Protein Analysis

Rebilda DC. Rebilda Post System. Rebilda

A new wave in instrument washing and disinfection Introducing the new HYDRIM G4 WD series

BUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS

Water Treatment & Purification Chemicals

Automatic Back-Flushing Filter AutoFilt RF9.

Dehumidifier D 850E. - Instruction manual version 02

STERILIZATION د STERILIZATION

SenTix 950 SenTix 980

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Customer: Cardiff Hospital NHS (United Kingdom) Machine:

Vertical and Benchtop Autoclaves for Life Sciences. Laboratory Line

ThermoSorb Desiccant Dryers

PTAC Preventive Maintenance Guide. Step-by-step instructions and information to keep your units operating in peak condition

Requirements for transport sequence, cleaning and disinfection

2KW CERAMIC HEATER DHCER20. User Manual

PEROXIDE SAFETY DATA SHEET (60% H2O2) Safety Data Sheet

XONYX Solid Surface Owner's Manual

Anodes and Misc Equipment

HMHF DIRECT DRIVE BELT DRIVE. Manufactured by UDY Corporation. Cyclone Models Available:

FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS


SunMaxx Solar Filling Station Operating Instructions

Pad printing accessories

Kompressoren. Adsorption Dryer AD

CanalPro TM Apex Locator

conductivity emulsification saponification wetting peptizing dispersion rinsability controlling mineral deposits Sequestration chelation

Instruction manual. VWR unstirred water baths

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

INTAC PARTS & SERVICES ( H)

Electric Rotary Actuator - On/Off or programmable control actuator

Operating Instuctions. Shaking device SV 14 / 22 SV 29 / 45. page 1

Transcription:

High-power ultrasound for dental practice and laboratory Simultaneous disinfection and cleaning of dental instruments

Content The Company profile 2 Ultrasonic baths for disinfection and cleaning of dental instruments 3 Recommendations for use 4 Digital or analogue? Our favorite! SONOREX DIGITEC DT 102 H 5 Digital ultrasonic baths SONOREX DIGITEC 8 Analogue ultrasonic baths SONOREX SUPER 7 Various applications or cleaning in cassettes? SONOREX DIGITEC DT 514 H and SONOREX SUPER RK 514 H 8 Various applications but no space? Ultrasonic built-in baths SONOREX ZE 514 DT and 514 9 Accessories 10 11 Disinfection and cleaning agents STAMMOPUR and TICKOMED 12 1

1 The Company profile BANDELIN electronic, a family-owned mid-sized com pany, is located in the capital of Germany Berlin. Development and manufacture of ultrasonic devices and disinfection and cleaning agents are carried out in Berlin. A wide vertical range of manufacture, modern production lines and a motivated staff guarantee a high quality of the products. The customers can buy everything from one-hand. Ultrasonic devices are in use in nearly all branches like industry, maintenance, service, medical, pharmaceutical and dental fields as well as laboratories. Development and manufacture of high-power ultrasonic units began already in 1955. The product range was enlarged in the middle of the eighties caused by increased sales. Adjustable and power-constant HF-generators were launched in 1992. The brand names SONOREX, SONOPULS and SONOMIC are equated with ultrasound from experts. The most important product groups are: SONOREX Ultrasonic baths and reactors SONOPULS Ultrasonic homogenisers SONOMIC Ultrasonic bath for rinsable keyhole surgery instruments and standard instruments TRISON Ultrasonic bath for robotic instruments, rinsable keyhole surgery instruments and standard instruments STAMMOPUR Disinfection and cleaning agents BANDELIN electronic is the leader in development of new ultrasonic devices and opening up new application areas. In the past about 33 patterns / utility patents and 56 brand names were applied for. The company supports several committees in compiling of norms and guidelines. All products are CE marked. 2

Ultrasonic baths for disinfection and cleaning of dental instruments FAST CLEANING RESULTS WITH ULTRASOUND The Contamination is detached from the instruments after a few seconds Dental forceps with blood residues sonicated in an ultrasonic bath SONOREX DIGITEC DT 102 H with STAMMOPUR R. Start 3 seconds 5 seconds 8 seconds 10 seconds ADVANTAGES OF ULTRASONIC CLEANING Fast instrument circulation. Disinfection time can be reduced to 5 minutes. Gentle intensive cleaning. Rapid cleaning of places difficult to reach such as cavities, holes etc. without provoking mechanical damage. Economical use of resources as water, chemicals and electricity. RECOMMENDED AGENTS Only water with appropriate additives do disinfect and clean properly. The disinfection and cleaning agents STAMMOPUR have been especially developed for the application in ultrasonic baths. Microbiological expertises are available for the time reduction of the disinfection process. WHEN IS A HEATER RECOMMENDED Ultrasonic baths without heater: For disinfection and simultaneous cleaning after dry deposit. Disinfection solutions may not be warmed up as the protein starts to coagulate at a temperature of 40 C (104 F). Ultrasonic baths with heater: For cleaning after wet deposit or for basic cleaning. Contaminations like fats and waxes are removed faster. WHAT KIND OF ACCESSORIES SHOULD BE USED Parts to be cleaned must not be placed on the tank bottom. Instruments are not to be stapled and baskets are not to be overloaded. Instruments like forceps and scissors must be opened completely or detached, if necessary. Instruments must be covered completely with liquid. 3

Recommendations for use BANDELIN ultrasonic baths enable a fast and thorough disinfection and cleaning of dental instruments, using the right accessories and preparations made especially for use with ultrasonic baths. Ultrasound intensifies the disinfecting effect and removes impurities from the deepest pores. Even hard-to-access spots, surfaces, corners and openings can be reached by the ultrasound ("electronic brushing"). It is important to notice that all cleaning objects must be thoroughly rinsed under running water after use in the ultrasonic bath. Objects to be cleaned Disinfection and cleaning agents Instructions for use Probes, stoppers, syringes and metal instruments Drill bits, root canal instruments with plastic handles Root canal instruments with anodized handle and colour coding STAMMOPUR DR 8 Disinfection and cleaning, VAH-certified, 0124 STAMMOPUR DB Disinfection and cleaning, VAH-certified, 0124 TICKOMED 1 Universal cleaner, Place in the or plastic insert basket, hang the basket in the oscillating tank. Sticky syringes become manoeuvrable once again with ultrasonic cleaning separate the plunger and cylinder from one another and sonicate again. Place in the insert basket and set the basket in the insert beaker. Place the positioning lid on top of the oscillating tank, hang the insert beaker into the positioning lid. Caution: Do not rinse, only air dry following disinfection and cleaning with STAMMOPUR DB the preparation contains a corrosion protection agent. Instruments in cassettes Removal of cement residue from glass parts, metal instruments, and tartar from dental prostheses TICKOMED 1 Universal cleaner, STAMMOPUR Z Special cleaner, only use in an inset beaker!, Cleaning is only possible in the SONOREX DIGITEC DT 514 H or SONOREX SUPER RK 514 H ultrasonic bath. Hang a maximum of 2 cassettes in the oscillating tank using the KAH 14 cassette holder. Place objects in the plastic insert tub with the cement-contaminated side facing downwards and hang the tub in the oscillating tank, or place the positioning lid on top of the oscillating tank and hang the insert beaker containing prostheses and instruments in the positioning lid. Removal of alginate deposits and dental plaster Crowns STAMMOPUR AG Special cleaner, ready to use, STAMMOPUR RD 5 for new articles. STAMMOPUR Z to remove cement residue, Place instruments in the insert basket, hang the basket in the oscillating tank. Some alginates swell during sonication and form a gelatin-like mass that absorbs the ultrasound. They are pre-soaked by the sonication to such an extent that they can be easily brushed off. Place in the insert basket with the opening facing downwards. Make sure that no bubbles remain in the hollow space. Place the basket in the insert beaker, place the positioning lid on top of the oscillating tank, and hang the insert beaker in the positioning lid. Impression trays STAMMOPUR AG, Slide them over the impression tray holder and hang in the oscillating tank. Steel prostheses (plates) STAMMOPUR RD 5, Place in the or plastic insert basket, hang the basket in the oscillating tank. The polishing agent will be thoroughly removed. 4

DIGITAL OR ANALOG? Your Choice! DIGITAL HIGH-POWER ULTRASONIC BATHS WITH DEGAS FUNCTION ANALOGUE HIGH-POWER ULTRASONIC BATHS EASY TO OPERATE SONOREX DIGITEC DT SONOREX SUPER RK Capacity (litres) 0.9 5.5 0.9 5.5 Operating instruments push-buttons turning knobs Time setting (min) 1 30, continuous operation 1 15, continuous operation Safety shut-down after 12 hours no Heating optional, version H optional, version H Sweep yes yes Degree of protection IP 33 IP 32 Our favorite! SONOREX DIGITEC DT 102 H Our most powerful 3-litres ultrasonic bath. 50 % MORE ULTRASOUND HARD CHROMIUM PLATED OSCILLATING TANKS 3 YEARS LONG-TERM WARRANTY HYGIENIC The flat front allows optimal disinfection and cleaning of the surface no space for hidden germ accumulation. EASY TO CLEAN splash-proof housing STRONG CLEANING POWER by 50 % more Ultrasound. ON- / OFF FUNCTION TEMPERATURE DISPLAY Excess temperature signal. FILLING MARK for safe dosage. HARD CHROMIUM PLATED oscillating tank. OUTLET one-piece drain, welded with ball valve. DEGAS FUNCTION: ON / OFF Ultrasound. FIXED PROGRAMMING Save last setting time. 5

3 D Digital ultrasonic baths From the front backwards: DT 31 H, DT 100 H, DT 102 H and DT 255 H Technical information Model Internal tank dimensions, l w d mm Capacity l External tank dimensions, l w h mm Ultrasonic peak output W HF-power W eff Heating power W Features DT 31 without heating 3200 DT 31 H with heating 3220 DT 100 without heating 3210 DT 100 H with heating 3230 DT 102 H with heating 3235 DT 255 without heating 3215 DT 255 H with heating 3240 190 85 60 0.9 205 100 180 160 40 190 85 60 0.9 205 100 180 160 40 70 240 140 100 3.0 260 160 250 320 80 240 140 100 3.0 260 160 250 320 80 140 240 140 100 3.0 260 160 250 480 120 140 outlet with ball valve G ¼. handles 300 150 150 5.5 325 175 295 640 160 outlet with ball valve G ¼, handles 300 150 150 5.5 325 175 295 640 160 280 outlet with ball valve G ¼, handles 6

3 6 Analogue ultrasonic baths From the front backwards: RK 31 H, RK 100 H, RK 102 H and RK 255 H Technical information Model Internal tank dimensions, l w d mm Capacity l External tank dimensions, l w h mm Ultrasonic peak output W HF-power W eff Heating power W Features RK 31 without heating 329 RK 31 H with heating 65 C fixed 044 RK 100 without heating 301 RK 100 H with heating 312 RK 102 H with heating 303 RK 255 without heating 3066 RK 255 H with heating 316 190 85 60 0.9 205 100 180 160 40 190 85 60 0.9 205 100 180 160 40 70 240 140 100 3.0 260 160 250 320 80 240 140 100 3.0 260 160 250 320 80 140 240 140 100 3.0 260 160 250 480 120 140 outlet with ball valve G ¼, handles 300 150 150 5.5 325 175 295 640 160 outlet with ball valve G ¼, handles 300 150 150 5.5 325 175 295 640 160 280 outlet with ball valve G ¼, handles 7

3 D DT 514 H and 6 RK 514 H Various applications or cleaning in cassettes? Everything is possible! Disinfection and clea ning of instruments placed in the insert basket K 14 with STAMMOPUR DR 8. Disinfection and cleaning of instruments in 2 insert baskets K 5 C with STAMMOPUR DR 8 or just cleaning in TICKOMED 1 / STAMMOPUR RD 5. Disinfection and cleaning of burs in insert beaker SD 06 to be placed into positioning lid DE 255 with STAMMOPUR DB and cement remo val of dental prostheses with STAMMOPUR Z. Technical information Disinfection and cleaning of burs and other small instruments in one operation: With basket K 5 C and positioning lid DE 255 to fix 2 insert beakers SD 06. Disinfection and cleaning of contaminated instruments placed in small basket K 5 C with STAMMOPUR DR 8. Disinfection and cleaning of burs in the insert beaker SD 06 with KD 0 and using STAMMOPUR DB. Removing of dental cements from instruments in a second insert beaker SD 06 and using STAMMOPUR Z. Cleaning of cassettes loaded with instruments in the cassette holder KAH 14 and using TICKOMED 1 up to 2 1/1 DIN cassettes, for surgery. up to 4 1/2 DIN cassettes, for prophylaxis. up to 8 1/4 DIN cassettes, for diagnostics and prophylaxis. Model DT 514 H RK 514 H 3211 277 Internal tank dimensions (l w d) (mm) 325 300 150 Capacity (litres) 13.5 Ultrasonic peak output (W) 860 HF output (W eff ) 215 Heating (W) 600 External tank dimensions (l w d) (mm) 355 325 305 Features Outlet with ball valve G ½, handles 8

3 Ultrasonic built-in baths ZE 514 DT and ZE 514 Various applications but no space? Everything is possible! Advantages space-saving and simple mounting into workplates enables free working area simple mounting by screwing hygienic care due to rounded tank edges and installation from below into the workplate Features ultrasonic frequency 35 khz oscillating tank made of stainless steel marking of filling level for safe dosage CE marked as a medical device SONOREX SUPER ZE 514 DT ZE 514 DT consists of an oscillating tank, HF-generator and control unit ST 30 DT with push-buttons and LCD-display for time and temperature. SONOREX SUPER ZE 514 consists of an oscillating tank, HF-generator and control unit ST 15. Technical information Model ZE 514 DT ZE 514 3202 2097 Internal tank dimensions (l w d) (mm) 325 300 150 Capacity (litres) 13.5 Operating vol. (litres) 9.0 External tank dimensions (l w d) (mm) 350 324 215 Outlet drain set G 1 ½ HF-generator dimensions (l w d) (mm) 305 310 142 Ultrasonic peak output (W) 860 HF output (W eff ) 215 Example mounting in a cabinet Current consumption (A) 1.0 9

3 Accessories Appropriate accessories facilitate ultrasonic application and simultaneously protect oscillating tank and parts to be cleaned. Objects to be cleaned or vessels must not be placed on the bottom of the ultrasonic tank! INSERT BASKET For direct cleaning of instruments (probes, pressers, syringes) in the oscillating tank. Optimum permeability of ultrasound. LID to protect the liquid from outside dirt. Condensed water runs back into the oscillating tank. INSERT TUB plastic, with lid For work with chemicals that attack the tank. INSERT BASKET plastic, perforated For sensitive surfaces. LID to protect the liquid from outside dirt. Recommended for insert baskets without handle. HOLDER With silicone spacer for save fixing of up to 8 impression trays. INSERT BASKET Basket holder KT 14 necessary. BASKET HOLDER For K 14 EM. CASSETTE HOLDER For simultaneous sonication of up to 2 cassettes (1/1 DIN). Additional accessories for indirect cleaning INSERT BEAKERS, plastic or glass EB 05 > KB 04 and PD 06 > plastic SD 04, SD 05, SD 06 > glass INSERT BASKETS or plastic For insertion into the beakers. For very small parts, e.g. burs and very sensitive surfaces. POSITIONING LID For fixing the insert beakers. LID DD 06 plastic For insert beakers SD 06, PD 06 and EB 05. Minimum order 10 pcs. 10

Accessories Model RK 31 / H DT 31 / H RK 100 / H DT 100 / H RK 102 H DT 102 H RK 255 / H DT 255 / H RK 514 / H DT 514 / H ZE 514 ZE 514 DT Insert basket, (l w h) mm K 08 170 65 50 209 K 3 C 200 110 40 3025 K 5 C 260 110 40 3027 K 5 C (2 pieces) 260 110 40 3027 K 14 275 245 50 354 Insert basket, plastic (l w h) mm PK 2 C 187 90 56 3082 K 5 P 254 96 130 113 Insert basket, (l w h) mm K14 EM 230 240 45 226 Basket holder, KT 14 131 Lid, D 08 218 D 100 3003 D 255 3007 D 514 3010 D 14* D 14 T** 344 3062 Insert tub, plastic (l w h) mm KW 3 195 115 88 715 KW 5 254 96 130 240 KW 14 280 215 145 613 Cassette holder, (l w h) mm KAH 14.1 305 208 52 7501 Holder, LT 102 371 LT 102 371 * installation from bellow (for KT 14 and K 14 EM) ** installation from above (for KT 14 and K 14 EM) Additional for indirect cleaning Accessories Model RK 31 / H DT 31 / H RK 100 / H DT 100 / H RK 102 H DT 102 H RK 255 / H DT 255 / H RK 514 / H DT 514 / H Positioning lid, DE 08 278 DE 100 3017 DE 255 3028 DE 255 (2 pieces) 3028 DE 514 3039 Insert beakers, / plastic / glass Capacity SD 04 400 ml 168 KB 04 400 ml 3000 SD 05 575 SD 06 330 PD 06 299 EB 05 350 SD 06 330 PD 06 299 EB 05 350 SD 06 330 PD 06 299 EB 05 350 Lid, plastic DD 06 350 Insert basket, KD 0 370 Insert basket, plastic PD 04 126 11

STAMMOPUR TICKOMED Disinfection and cleaning agents Optimum cleaning results require the application of appropriate disinfection and cleaning agents. Many disinfection and cleaning agents contain substances that can attack the oscillating tank. STAMMOPUR and TICKOMED have been especially developed for ultrasonic application and are CE marked according the Medical Device Directive. All agents are environmentally friendly and biodegradable. Agents Description Application with ultrasound (time) Litres Code No. STAMMOPUR DR 8 VAH-certified Simultaneous instrument disinfection and intensive cleaning Disinfection and intensive cleaning of instruments after dry deposit. High blood dissolution, for instruments heavily contaminated with incrustations of blood and secretions. Short irradiation time. Solution applicable under strain for 3 sequent days. Very high material compatibility. Concentrate. Non-odiferous. Anticorrosive. Without aldehydes, chlorine, phenols. Bactericidal, tuberculocidal, yeasticidal, virucidal against Vaccinia, BVDV, Papova, Adeno, HBV, HCV, HIV, H5N1, mildly alkaline ph 9.4 at 1 %. Hazard identification: C, Corrosive; N, Dangerous for the environment 100 g contain: 9.9 g bis(3-aminopropyl)dodecylamine, 8.4 g didecylmethylpolyoxyethylammoniumpropionate, 5-10 % non-ionic tensides, 30-50 % solvents, complexing agents, ph-regulators, adjusting agents, corrosion protection. Expertises: Bacteria, fungi: Dr. F.-A. Pitten, Gießen 11/05, Prof. Dr. Werner, Schwerin 10/08; HBV/ HIV: Prof. Dr. Frösner, München 08/99; Time durability: Prof. Dr. Werner, Schwerin 10/99; Ultrasound time reduction: Dr. Färber, Gießen 08/02; Vaccinia, BVDV, H5N1: Prof. Dr. L. Döhner, Dr. D. Becher, Greifswald 08/06; Papova: Prof. Dr. L. Döhner, Dr. D. Becher, Greifswald 01/07. Adeno: Dr. M. Büttner, Dr. D. Becher, Greifswald 11/08. 2 %, 5 min 1,5 %, 10 min 1 %, 15 min Papova with high protein burden: 2 %, 10 min Adeno with high protein burden: 3 %, 15 min Application without ultrasound: 1 %, 60 min 2 %, 30 min 3 %, 15 min 2 5 25 972 974 936 STAMMOPUR RD 5 Intensive cleaner for instruments Removes obstinate, encrusted contaminations like blood, secretions, sputum, grinding and polishing residues, fat, wax, tissue residues, filling materials from instruments, devices, dentures, crowns. Concentrate. High material compatibility, with corrosion protection. Not applicable 3 %, 2 10 min 2 5 25 827 901 902 TICKOMED 1 Universal cleaner for instruments Removes blood, secretions, sputum, grinding and polishing paste, fat, wax, tissue residues, filling materials, dentinal splinters from instruments, devices, dentures, burs. Concentrate. Very high material compatibility, with corrosion protection. Also for use on light metals. Applicable as contact liquid. Mildly alkaline, ph 9.0 at 1 %. Hazard identification: Xi Irritant 3 %, 2 10 min 2 5 25 904 949 961 STAMMOPUR Z Cement remover and dentur cleaner Removes dental cements (except some glasionomer cements), tartar, provisional filling materials, embedding materials, oxides and fluxes from instruments and dentures. Concentrate. For, precious metals, plastics, ceramics. Not for use on light metals. Caution with damaged chrome-plated material. Application only in insert beakers (indirect sonication, contact liquid STAMMOPUR DR 8 or TICKOMED 1). Acid, ph 1.9 at 1 %. Hazard identification: C Corrosive 5 %, 2 10 min 2 5 25 822 928 929 STAMMOPUR AG Plaster and alginat remover Removes plasters, alginates, impressing and embedding materials from impression trays, dental tools and accessories. Ready for use. Very high material compatibility. For all materials, also for light metals. Also applicable without ultrasound e.g.: plaster traps, vacuum mixing devices undiluted for 15 120 min. Mildly alkaline, ph 8.0. undiluted 3%, 3 10 min 2 5 25 825 906 907 STAMMOPUR DB VAH-certified Bur disinfection and cleaning Simultaneous disinfection and cleaning of rotating dental instruments like burs, cutters and files. Ready for use. With corrosion protection. High material compatibility. Caution with light metals. Not for alkali- and alcohol-sensitive materials. Active against bacteria (incl. Tb.-B.), fungi, viruses (Adeno, Polio according EN 14476 with high protein burden). Alkaline, ph 13.0. Hazard identification: Xi Irritant 100 g contain: 30 g 2-Ppropanol, 0,1 g Didecyldimethylammononiumchloride, inhibitors, inorganic salts. Expertises: Bacteria, fungi: Prof. Dr. Wille, 06/04 Gießen; Dipl. Biol. T. Koburger, 07/11 Greifswald; PD Dr. med. F. A. Pitten, Gießen 09/11; Adeno, Polio: Dr. M. Büttner, Dr. D. Becher, 05/11 Greifswald; Ultrasound time reduction: Prof. Dr. Hartmann, 03/94 Berlin. undiluted 5 min 2 5 25 821 984 933 12

Made in Germany. Made in Berlin. BANDELIN electronic GmbH & Co. KG Heinrichstrasse 3 4 12207 Berlin GERMANY Tel.: +49 30 76880-0 Fax: +49 30 7734699 info@bandelin.com BANDELIN electronic is specialized in the development and manufacturing of ultrasonic devices. CERTIFICATION EN ISO 9001:2008, EN ISO 13485:2012 WE ADVISE YOU PERSONALLY! FEEL FREE TO CONSULT OUR EXPERTS : +49 30 76880-0 www.bandelin.com 76020 GB/2015-02 All units are CE marked. Subject to technical alterations without notice. Illustrations exemplary, not true to scale. Decoration products are not included in delivery. The general terms and conditions apply.