The new standard in research microscopy



Similar documents
ISO9001 ISO Environmentally-friendly product All optical components in CX41 microscope use lead-free eco-glass.

A new advance in routine inspections INVERTED MICROSCOPE CKX41/CKX31

Olympus BX51 Microscope & DP70 Digital Camera System

Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES

RESEARCH MACRO ZOOM SYSTEM MICROSCOPE MVX10. Macro View. The first true macro fluorescence imaging system

How To Use An Asbestos Microscope

POLARIZING MICROSCOPE BX51-P BX2 SERIES

Biological Microscope. Biological Microscope ECLIPSE E200

Chapter 12 Filters for FISH Imaging

microscope OP-Dent-5

Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012

Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University

MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.

Optical laser beam scanner lens relay system

Rodenstock Photo Optics

OPERATING INSTRUCTIONS XJL 101/101A REFLECTED LIGHT METALLURGICAL MICROSCOPE

Measuring the Point Spread Function of a Fluorescence Microscope

Powerful Upright Microscope Solutions for Life Science and Clinical Applications

Flat-Field IR Mega-Pixel Lens

Inspection and Illumination Systems for Visual Quality Assurance. Large selection Attractive prices Tailored solutions. optometron.

AxioCam MR The All-round Camera for Biology, Medicine and Materials Analysis Digital Documentation in Microscopy

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

Leica DM LS2 and DM LB2. Life Science System Microscopes with New Ergonomic Concept

Fast Z-stacking 3D Microscopy Extended Depth of Field Autofocus Z Depth Measurement 3D Surface Analysis

MICROSCOPES & REFRACTOMETERS for laboratory, industry and food

THE COMPOUND MICROSCOPE

Rodenstock Photo Optics

Product Range Overview

LABORATORY MICROSCOPEs

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

SLIT LAMP BQ 900 Sophisticated microscopy

AxioCam HR The Camera that Challenges your Microscope

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

The Kaps SOM -Series. Stereo Examination Microscopes for ENT Specialists. The variable space-saving system for every ENT practice

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

MT-30 & MT-90 Series. Advanced Academic Microscopes/ Advanced Academic Polarizing Microscope INSTRUCTION MANUAL

FIXED STAGE UPRIGHT MICROSCOPE BX51WI FIXED STAGE UPRIGHT MICROSCOPE WITH MOTORIZED FOCUSING BX61WI UNIVERSAL INFINITY SYSTEM

Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.

Science In Action 8 Unit C - Light and Optical Systems. 1.1 The Challenge of light

TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions

Phoroptor VRx Digital Refraction System

Zeiss 780 Training Notes

Software-based three dimensional reconstructions and enhancements of focal depth in microphotographic images

The Applied Imaging Cytogenetic Workstation

Care and Use of the Compound Microscope

VICKERS HARDNESS TESTER. HBS HBW Kc

First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between

EXPERIMENT #1: MICROSCOPY

EVIDENCE PHOTOGRAPHY TEST SPECIFICATIONS MODULE 1: CAMERA SYSTEMS & LIGHT THEORY (37)

Compound microscope (Hund)

Preface Light Microscopy X-ray Diffraction Methods

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

The best lab standard. 1,4 Megapixels 2/3 inch sensor Giant pixel size 6 times optical zoom Massive 16-bit imaging for enhanced dynamic

Leica MZ125. Modular high-performance stereomicroscope with 12.5:1 zoom

Lenses and Apertures of A TEM

Chapter 13 Confocal Laser Scanning Microscopy C. Robert Bagnell, Jr., Ph.D., 2012

The Basics of Scanning Electron Microscopy

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

A NEW LOOK AT RISLEY PRISMS. By Craig Schwarze Senior Systems Engineer OPTRA Inc.

UIS OBJECTIVES FOR LIFE SCIENCE UNIVERSAL INFINITY SYSTEM

WHITE PAPER. Are More Pixels Better? Resolution Does it Really Matter?

Photography of Cultural Heritage items

Application Report: Running µshape TM on a VF-20 Interferometer

euromex microscopen bv The Netherlands page1/16

Bio 321 Lightmicroscopy Electronmicrosopy Image Processing

product overview pco.edge family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology

Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR Spectrometer and URA Accessory

Fig.1. The DAWN spacecraft

TAGARNO AS Sandøvej Horsens Denmark Tel: Mail: mail@tagarno.com

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

EyeMag Medical Loupes from ZEISS Seeing is believing NEW! LED illumination

Neuro imaging: looking with lasers in the brain

Video Camera Image Quality in Physical Electronic Security Systems

Interference. Physics 102 Workshop #3. General Instructions

GLobAL Dental Microscopes. Dentists First Choice

View of ΣIGMA TM (Ref. 1)

Overview. Proven Image Quality and Easy to Use Without a Frame Grabber. Your benefits include:

Automatic and Objective Measurement of Residual Stress and Cord in Glass

2) A convex lens is known as a diverging lens and a concave lens is known as a converging lens. Answer: FALSE Diff: 1 Var: 1 Page Ref: Sec.

Firearms & Tool Marks Comparison Microscope. Discovery. Leeds Forensic Systems. Your Forensic Imaging Source

Basler. Line Scan Cameras

Advances in scmos Camera Technology Benefit Bio Research

Infrared Viewers. Manual

EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab

Basler. Area Scan Cameras

Biomedical & X-ray Physics Kjell Carlsson. Light Microscopy. Compendium compiled for course SK2500, Physics of Biomedical Microscopy.

Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002

TEC APO140. This telescope is closer to optical perfection more than any instrument I have ever used before. R.Renzi, Italy.

Quick Start Guide. Digital Inverted Microscope. The Microscope Evolved.

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

Endoscope Optics. Chapter Introduction

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

Encoders for Linear Motors in the Electronics Industry

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

Confocal Microscopy and Atomic Force Microscopy (AFM) A very brief primer...

QUALITY SUPER 8 MOVIE CAMERAS

Color holographic 3D display unit with aperture field division

D/N VARI-FOCAL IR CAMERA

Basler pilot AREA SCAN CAMERAS

Transcription:

SYSTEM MICROSCOPE Olympus is about life. About photographic innovations that capture precious moments of life. About advanced medical technology that saves lives. About information- and industry-related products that make possible a better living. About adding to the richness and quality of life for everyone. Olympus. Quality products with a BX2 SERIES The new standard in research microscopy UNIVERSAL INFINITY SYSTEM

BX51 universal research microscopy The perfect union of Olympus UIS optics and advanced fluorescence technology Superb optical performance Outstanding fluorescence capability Contrast and resolution optimized Nomarski DIC Structural rigidity and compact Y-shape Research imaging platform Logical layout and ergonomic design Great system versatility with a wide range of accessories *Note: UIS optics: The original Olympus infinity-corrected optical system. This system expresses the superb Olympus optical technology, provides high resolution, high contrast images and the flexibility to meet current and future applications. O t t 1

Overlay image of the microscope frame and the dicast 2

Fluorescence observation Sophisticated fluorescence detection, observation and imaging Two new illuminators for more efficient illumination With greater efficiency and significantly brighter images, two new fluorescence illuminators support every aspect of your imaging needs. The illuminators, for routine and for advanced applications, benefit from illumination optics that efficiently capture all available light from the Mercury or Xenon arc lamps. Fully integrated into the microscope arm, the illuminators add to the stability of the imaging platform. Chromatically corrected illumination from UV to IR A new aspheric collector lens improves the light collection ability and stretches the achromatic performance of the illumination optics to include the wavelength range from UV to IR (infrared). This meets the need for even and efficient illumination throughout this extended spectrum; from fura-2 to Cy7 the improved efficiency leads to greater detection sensitivity, brighter images and shorter exposures for imaging. Fast access to 6 filter cubes Fast access to more filter cubes takes the ever increasing need for highly tailored single and multi band imaging of new fluorochromes and fluorescent proteins into account. The 6-cube filter turret can be swapped easily for even greater filter selection. When requirements change, filter cube replacement takes only seconds. Large, luminous labels identify the filter cube in use, even in a darkened environment. BX-RFA BX fluorescence illuminator and filter cubes 3

Fluorescence observation Impressive objectives for fluorescence microscopy Olympus objectives are renowned for producing images of great brightness, clarity, high contrast and high resolution. To meet the special needs of fluorescence microscopy, of live cell observation or to address emerging needs, Olympus has designed objectives with specialized performance characteristics. Included in these objective sets are high numerical aperture (N.A.) oil and water immersion objectives, for best fluorescence performance, absence of spherical aberration and the best resolution possible. There are special objectives for applications with UV confocal laser scanning microscopes, whose apochromatic correction spans from ultraviolet to infrared. And there are special objectives for enhanced performance with 2-photon microscopy and those with a super symmetrical point spread function, supporting deconvolution techniques. UPLAPO Series Universal objectives, perfect for general fluorescence observation, also in combination with differential interference contrast. UAPO W Series High numerical aperture, water-immersion objectives which prevent the occurrence of spherical aberrations. As a result, they procure high resolution, high contrast and aberration-free images of the interior of cultured cells, fixed specimens in aqueous media or other specimens with a refractive index similar to that of water. UAPO/340 Series This objective series has enhanced transmission for UV excitation at 340nm, making them particularly effective for use with fluorescent probes such as fura-2, indo-1, and others for Calcium Ratio Imaging or intra cellular ph measurement. With their high transmission and numerical aperture, these objectives provide the maximum performance in fluorescence microscopy. UPLAPO60 W/IR This water immersion objective is corrected for apochromatic performance, including the wavelengths from 450-1100nm, making the objective suitable for 2-photon microscopy and for simultaneous observation of IR-DIC with images in the visible and near UV range, without focus errors between these extreme wavelengths. APO100 N.A. 1.65 Enabling illumination of specimens with a N.A. higher than the refractive index of living cells, this objective makes the observation of cells at the molecular level possible. Multi band fluorescence excitation with a stationary beamsplitter The auxiliary filter slots in the excitation and emission positions accept six-position filter sliders. Now the utility of multi-band filter sets can be fully utilized, even with manually operated components. As an example such a slider can be equipped with three single, two dual and one triple band exciter, providing all excitation modes typically wanted with just one filter set. The emission position can be treated similarly. Such a filter slider set (excitation and emission) can be conveniently linked and operated simultaneously for further optimization. 4

Fluorescence observation Addressing imaging challenges and broadening system versatility Accessible field and aperture planes The fluorescence illuminator BX-RFA, with its interchangeable / removable field and aperture stops, opens the microscope to an entirely new range of imaging options. A rectangular field diaphragm can be substituted for the conventional circular diaphragm, a light source or flash for decaging can be introduced or imaging accessories, yet to be invented, can be easily placed into the appropriate optical planes. BX-RFSS rectangular field stop Excitation balancers Fluorescence excitation balancers Excitation balancers are an exclusive Olympus accessory, available for most common dual or multi-label specimen. Used singly or in tandem, they curtail the individual excitation bandwidths of the fluorochromes under observation. This purposefully restricted excitation equalizes the emission intensities. Better differentiation of the multi-labels and better visibility of detail is achieved. This simple and visually controlled adjustment leads to perfect photomicrographs and digital images benefit from less severe post processing. Triple labeled specimen with FITC and Cy3 ehanced Triple labeled specimen with DAPI and Cy3 ehanced Triple labeled specimen with balanced fluorescence representation 5

Comparing the circular and rectangular field stop options Traditionally field stops have been designed with visual observation in mind. They deliberately restrict the area of illumination and thereby increase image contrast. With the prevalence of digital imaging and rectangular imaging sensors, rectangular field stops are the next logical step toward maximizing Koehler illumination and S/N (signal to noise) ratio for those devices. As an additional benefit a larger specimen area is protected from fluorescence excitation and potential photo bleaching. When using programmable scanning stages the image rectangle can be adjusted to coincide with the stage step size. Unnecessary exposure area caused by a round field stop BX-RFSS rectangular field stop T (%) 100 80 85 60 40 20 30 0 350 BG Characteristic curves of spectrum 490 565 400 500 600 650 (nm) T (%) 100 80 60 40 20 0 350 UG 400 500 600 650 (nm) Excitation balancers are available for adjustment of the following fluorescence excitation pairs: Excitation balancer BG (U-EXBABG) blue / green, adjusting green and red emissions Excitation balancer UB (U-EXBAUB) UV / blue, adjusting blue and green emissions Excitation balancer UG (U-EXBAUG) UV / green, adjusting blue and red emissions T (%) 100 UB 80 60 40 Incident angle 90º Incident angle 45º 20 0 350 400 500 600 650 (nm) 6

Nomarski DIC observation DIC without compromises higher resolution, higher contrast Optimal prism combinations for all specimen and magnifications The nature of the specimen, such as its refractive index, thickness and surrounding medium, greatly influences formation of images in Differential Interference Contrast. Achieving the best visibility, the balance between high contrast or high resolution, calls for specimen and magnification dependent DIC-prism shearing distances and prism selection. Analyzer Universal condenser with 8 turret positions The universal condenser simultaneously accepts up to 6 DIC prisms and 2 other optical components at maximum. The condenser numerical aperture of 0.9 or 1.4 (oil) can be selected through interchangeable top elements. The Olympus Nomarski DIC system includes the prism combinations to choose for each imaging task. The general-purpose prism sets are supplemented with special purpose sets, addressing the demands for the highest resolution or highest contrast under specific magnification and specimen conditions. Objective Specimen DIC prism (Objective side) For ease of use, prism markings follow the ISO objective color coding principle. Prism adjustment is carried out away from the objective, on the DIC slider that is housed in its nosepiece slot. Polarizer DIC prism (Condenser side) U-UCD8 For high contrast For high resolution General Specimen Thin (NG108) Thick (Diatom) (PtK2 ) Objective High magnification* 1 Low to High magnification Low to High magnification DIC slider U-DICTHC U-DICTHR U-DICT U-DICTS* 2 (Objective side) * 1 For low magnifications of thin specimen the U-DICT prisms are recommended. * 2 Height adjustable, compatible with objectives having different pupil positions 7

Other observation methods Brightfield: Greater resolution and flatness for all magnifications Images of high resolution and flatness, from low to high magnifications are produced with the PLAPO objectives. Their widefield capability, combined with an Achromatic/ Aplanatic condenser (U-AAC), specially designed for brightfield observation, results in a 26.5 field of view number. With the U-SC3 swing out condenser, it is possible to get optimal illumination from 1.25 * to 100 without changing the condenser. For optimum results at the low magnification side a special condenser (U-ULC) serves overview magnifications with the PLAPO objectives 1.25* and 2. *When photographing with the 1.25 objective, please use the ultra low condenser U-ULC2. U-SC3 U-AC U-AAC Darkfield: Outstanding contrast from low to high magnifications Two darkfield condensers are provided: Dry darkfield condenser U-DCD, for magnifications from 10 to 40 (up to N.A. 0.65). Oil immersion darkfield condenser U-DCW, for magnifications from 10 to 100 (up to N.A.1.02) The Universal Condenser U-UCD8 and the phasecontrast condenser U-PCD2 produce darkfield with objectives up to N.A 0.7. U-DCD U-DCW Phase-contrast: Superior resolution and contrast High contrast phase imaging allows close observation of the cell interior and of live bacteria. The BX51 uses the UPLAPO PH series of objectives, which produce very high resolution transmitted light phase-contrast with the phase-contrast condenser U-PCD2. Standard brightfield and dry darkfield observations and simultaneous observation of incident light fluorescence are possible. Polarized light: Qualitative and quantitative polarized light microscopy The range of specialized POL-accessories equips the BX51 as a full range polarized light research microscope. Important components include the centerable precision rotating stage, the centerable POL-nosepiece with compensator slot and a complete selection of compensators, covering a wide retardation range. The special POL-condenser and the universal pol objective series UPLFL P, together with conveniently attachable modules for orthoscopic and conoscopic observation complete the instrument. 8

Ergonomy Design priorities include advanced ergonomics for operational efficiency and convenience Comfortable working position Employing the U-ETBI ergonomic binocular observation tube ensures that every user can work with the most comfortable eyepoint and observation posture, even when using an additional intermediate component. The inclinable and telescoping observation tube increases the distance between the microscope and the user and can be adjusted within a range of 45mm. This, together with the inclination option, provides ample flexibility to accommodate the natural differences in stature and posture between users. Compact Y-shape utilizes space efficiently With more room to the left and right of the microscope observation tube, the Y-shaped frame is now more compact than ever. The depth of the microscope has been shortened and the new design of the lamp housing minimizes protrusions. As a result the BX51 frame allows more effective use of space. Peripheral equipment, accessories or various control units can be placed right beside the microscope, in easy reach of the operator. Especially research setups requiring connection to PC's and electronic image recording equipment benefit from the space efficient layout. 317.5mm Convenient operation Stage controls and focusing knobs are ideally positioned for easy manipulation with minimal movement and without raising the forearms from the work surface. The fine focusing knob can be moved to either side of the microscope and its slim design and smooth tactile surface enables it to be operated even with a single finger. The high focus sensitivity makes fine focusing accurate, especially for high magnifications. Ergonomic stage control knobs have a large diameter for enhanced feel and precision positioning. 341mm 415mm U-SVLB-4 mechanical stage with left-hand control & tactile covers 270 degree U-SVRB-4 mechanical stage with right-hand control & tactile covers 9

Optical performance / mechanical stability Whatever the application, world-class optical performance and structural rigidity are vital Additional intermediate tubes or filters Parallel light beams UIS optics: The first choice for all applications The UIS optical system maintains the same intermediate image plane even when prisms, sliders or other optical accessories are interposed in the light path between the objective and tube lens, so that total magnification remains the same. Within the UIS system objectives are fully corrected and imaging devices receive a fully corrected image under all adaptation conditions. This combination of flexibility and high performance makes the UIS optical system ideal for both present and future research needs. Easy changeover between observation methods Switching between observation methods is much easier with the wide range of equipment selections available for the BX51 microscope. Important examples are: - The septuple revolving nosepiece for faster access to a greater objective selection, - The 8-position universal condenser, holding as many DIC prisms or phase annuli, - The incident light fluorescence illuminator with its 6 filter cube capacity for fast change of excitation modes, - The unique 6-position tandem filter slider for the most economical application of multi-wavelength excitation Fully prepared for the growing research requirements in fluorescence microscopy and in digital imaging, the BX51's combination of versatility and stability makes it the natural first choice for users with a diverse range of advanced research microscopy needs. Structural reinforcement for superior rigidity and stability The BX51 frame is reinforced for the greatest rigidity and stability, a key requirement for meeting the entire range of research microscopy challenges and applications. Designing the microscope arm as a monolithic component, an Olympus innovation, enhances its structural integrity. The fluorescence illumination axis remains entirely stable, a prerequisite for the most demanding multi-label applications where sub-pixel registration is essential. 10

Imaging Imaging and documentation: Fast, easy and universal Limitless options As a research microscope the BX51 is open to the adaptation of the entire spectrum of imaging devices from confocal microscopes to digital cameras of every make and specialization, to spectral imaging devices, PMT's, APD's and devices yet to be invented. The variety of readily available adapters is extensive, custom adaptation options are limitless. Microscope digital camera system DP50 The DP50 digital camera employs a 1/2 inch, 1.5 million pixel CCD to obtain superbly detailed images, recorded at a 5.8 million pixel equivalent, whose quality rivals that of conventional 35mm film photography. A built-in Peltier device cools the CCD sensor, reducing noise and ensuring excellent color reproduction even of fluorescence specimens. Framing and focusing functions are performed expediently through the microscopy user interface. DP50 Automatic photomicrographic system PM30 A "super FL auto exposure mode" and a conventional auto exposure mode are available to the user, providing superior fluorescence photomicrography at the release of the shutter. Tedious exposure calculations and compensations are performed automatically. In combination with selectable spot and averaging metering options (0.1% micro-spot, 1% spot and 30% average), photomicrographs are guaranteed to be perfect every time. PM30 Trinocular intermediate attachment U-TRU This intermediate trinocular attachment can be used simultaneously with the inclinable binocular observation tube (U-TBI3). Two light paths are selectable: 100% light for binocular observation or 20% for binocular observation and 80% for imaging through the trinocular port. Dual port U-DP The dual port may be used for a variety of purposes: separating the image by spectral composition (e.g. directing fluorescence to one port, infrared to the other), as an illumination port for adding a new incident light source or as a C- mount compatible trinocular port for image output. A 1x image formation lens is also provided. U-DP U-DP1 11

Viewing attachments A range of attachments for easy multi-observation Multi observation bodies Universal components can be linked into multi observation / discussion stations, accommodating from 2 to 10 observers. An arrow pointer with LED aids communication, the visual field to each observer is identical. U-SDO3 for two persons U-MDOB3 for five persons Arrow pointer U-APT Enables insertion of a red or green LED arrow for display on a monitor or for reproduction with a photomicrograph. U-MDO10B3 for ten persons U-APT + Video camera Accessories Centerable sextuple revolving nosepiece U-P6RE Sextuple centerable revolving nosepiece, allowing centration of 3 objectives. 2 magnification changer U-ECA Magnification is doubled by engaging the auxiliary 2 lens. Acting on both the visual and the camera ports, this is the most convenient way to increase magnification for observation or imaging. Drawing attachment U-DA The drawing attachment projects an image of the pencil and drawing surface into the visual field. Tracing of microscopic structures is made easier and more accurate. A 10 magnification attachment is available. U-DA U-DAL10 12

BX51 specifications Microscope frame Optical system UIS optical system Focus Vertical stage movement: 25mm stage stroke with coarse adjustment limit stopper Torque adjustment for coarse adjustment knobs Stage mounting position variable High sensitivity fine focusing knob (minimum adjustment gradations: 1µm) Illuminator Built-in Koehler illumination for transmitted light 12V100W halogen bulb (pre-centered) Light preset switch Light intensity LED indicator Built-in filters (LBD-IF, ND6, ND25 optional) Revolving nosepiece Interchangeable reversed quintuple/sextuple/septuple nosepiece Observation tube Widefield (F.N. 22) Widefield binocular, inclined 30 Widefield tilting binocular, inclined 5-35 Widefield trinocular, inclined 30 Widefield ergo binocular, inclined 0-25 Super widefield (F.N. 26.5) Super widefield trinocular, inclined 24 Stage Ceramic-coated coaxial stage with left or right hand low drive control: with rotating mechanism and torque adjustment mechanism, optional rubber grips available (Non stick grooved coaxial, plain, rotatable stages are also available) Condenser Abbe (N.A. 1.1), for 4 100 Swing out Achromatic (N.A. 0.9), for 1.25 100 (swing-out: 1.25 4 ) Achromatic Aplanatic (N.A. 1.4), for 10 100 Universal (N.A. 1.4/0.9), for 2 100 (swing-out: 2 4, with oil top lens: 20 100 ) BX51 dimensions (unit: mm) 175 187* 84 209 503 412* 45 65 90 317.5 341 415 The length marked with an asterisk (*) may vary according to interpupillary distance. Distance for figure shown is 62mm. Web site addresses:http://www.olympus.com ISO 9001 Accredited by the Dutch Council for Accreditation ISO9001 Certification Certificate No.40826 Design and production adheres to ISO9001 international quality standard. ISO 14001 ISO14001 Certification Certificate No. 961049 Design and production at the Olympus Optical Co. Ltd. Ina Plant conforms with ISO14001 specifications for environmental management systems. Specifications are subject to change without any obligation on the part of the manufacturer. 2-43-2,Hatagaya, Shibuya-ku, Tokyo, Japan Postfach 10 49 08, 20034, Hamburg, Germany 2 Corporate Center Drive, Melville, NY 11747-3157, U.S.A. 491B River Valley Road, #12-01/04 Valley Point Office Tower, Singapore 248373 2-8 Honduras Street, London EC1Y OTX, United Kingdom. 104 Ferntree Gully Road, Oakleigh, Victoria, 3166, Australia