For information regarding shipping specifications, please refer to the following link: http://dna.macrogen.com/eng/help/orderg.jsp



Similar documents
To order the sequencing service, please access to our online ordering system and create an account;

Introduction. Preparation of Template DNA

Procedures For DNA Sequencing

SEQUENCING SERVICES. McGill University and Génome Québec Innovation Centre JANUARY 21, Version 3.4

DNA Sample preparation and Submission Guidelines

DNA Sequencing Handbook

Genomic DNA Clean & Concentrator Catalog Nos. D4010 & D4011

Sanger Sequencing. Troubleshooting Guide. Failed sequence

PicoMaxx High Fidelity PCR System

BigDye Terminator v3.1 Cycle Sequencing Kit. Protocol. DRAFT August 27, :32 pm, A_v3.1Title.fm

First Strand cdna Synthesis

UltraClean PCR Clean-Up Kit

RT rxns. RT rxns TRANSCRIPTME Enzyme Mix (1) 40 µl 2 x 50 µl 5 x 40 µl

TIANquick Mini Purification Kit

DNA Sequencing Troubleshooting Guide

ISOLATE II PCR and Gel Kit. Product Manual

Description: Molecular Biology Services and DNA Sequencing

Sequencing Guidelines Adapted from ABI BigDye Terminator v3.1 Cycle Sequencing Kit and Roswell Park Cancer Institute Core Laboratory website

How To Use An Enzymatics Spark Dna Sample Prep Kit For Ion Torrent

AxyPrep TM Mag PCR Clean-up Protocol

Troubleshooting Sequencing Data

1/12 Dideoxy DNA Sequencing

MICB ABI PRISM 310 SEQUENCING GUIDE SEQUENCING OF PLASMID DNA

Aurora Forensic Sample Clean-up Protocol

DNA SEQUENCING SANGER: TECHNICALS SOLUTIONS GUIDE

DNA Sequencing Setup and Troubleshooting

Application Guide... 2

GENEWIZ, Inc. DNA Sequencing Service Details for USC Norris Comprehensive Cancer Center DNA Core

Taq98 Hot Start 2X Master Mix

TransformAid Bacterial Transformation Kit

Sanger Sequencing: Sample Preparation Guide

ZR DNA Sequencing Clean-up Kit

PyroPhage 3173 DNA Polymerase, Exonuclease Minus (Exo-)

MEF Starter Nucleofector Kit

MLX BCG Buccal Cell Genomic DNA Extraction Kit. Performance Characteristics

DNA Core Facility: DNA Sequencing Guide

PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System) 50 preps Product #60200

PrimeSTAR HS DNA Polymerase

FOR REFERENCE PURPOSES

NimbleGen DNA Methylation Microarrays and Services

Thermo Scientific DyNAmo cdna Synthesis Kit for qrt-pcr Technical Manual

RevertAid Premium First Strand cdna Synthesis Kit

DNA Sequencing Troubleshooting Guide.

How To Get Rid Of Small Dna Fragments

Automated High Throughput Purification of BigDye TM Terminator Fluorescent DNA Sequencing Reactions Using Wizard MagneSil TM Paramagnetic Particles

Dye-Blob message: Example: Generally, this is due to incomplete excess dye removal of the cycle sequence reaction.

SERVICES CATALOGUE WITH SUBMISSION GUIDELINES

A Brief Guide to Interpreting the DNA Sequencing Electropherogram Version 3.0

ab Hi-Fi cdna Synthesis Kit

UltraClean Soil DNA Isolation Kit

BacReady TM Multiplex PCR System

GENOME RUSSIA PROJECT BLOOD SAMPLES COLLECTION, DNA EXTRACTION AND DNA QUALITY CONTROL PROTOCOLS

PCR was carried out in a reaction volume of 20 µl using the ABI AmpliTaq GOLD kit (ABI,

Creating Standard Curves with Genomic DNA or Plasmid DNA Templates for Use in Quantitative PCR

Transformation Protocol

Thermo Scientific Phusion Site-Directed Mutagenesis Kit #F-541

The RNAi Consortium (TRC) Broad Institute

Contents. XI. Materials and Equipment Needed But Not Provided 5. DNA Extraction from Small Amount of Tissue 10

DNA-functionalized hydrogels for confined membrane-free in vitro transcription/translation

Reconstituting and Diluting Primers and TaqMan Probes

Updated: July ' End label RNA markers (18mer) and (24mer) with Kinase and 32P-gamma-ATP. Gel purify labeled markers.

ZR-96 DNA Sequencing Clean-up Kit Catalog Nos. D4052 & D4053

Inverse PCR & Cycle Sequencing of P Element Insertions for STS Generation

SERVICE REQUEST OF DNA SEQUENCING

Introduction to cloning

Genomic DNA Extraction Kit INSTRUCTION MANUAL

Plant Genomic DNA Extraction using CTAB

Lab 10: Bacterial Transformation, part 2, DNA plasmid preps, Determining DNA Concentration and Purity

USER GUIDE. Encore PART NOS and SP Rapid Library Systems

Genomic Services and Development Unit User Manual

Southern Blot Analysis (from Baker lab, university of Florida)

qstar mirna qpcr Detection System

EZ Load Molecular Rulers. Catalog Numbers bp bp bp PCR bp kb Precision Mass

Preparing Samples for Sequencing Genomic DNA

All-in-One mirna qrt-pcr Reagent Kits For quantitative detection of mature mirna

360 Master Mix. , and a supplementary 360 GC Enhancer.

TaqMan Fast Advanced Master Mix. Protocol

Western Blotting: Mini-gels

Amplicon Template Preparation and Sequencing

Sanger Sequencing and Quality Assurance. Zbigniew Rudzki Department of Pathology University of Melbourne

ab Protein Sumoylation Assay Ultra Kit

RT-PCR: Two-Step Protocol

CUSTOM DNA SEQUENCING SERVICES

illustra TempliPhi DNA Sequencing Template Amplification Kit

Wizard DNA Clean-Up System INSTRUCTIONS FOR USE OF PRODUCT A7280.

STA DARD OPERATI G PROCEDURE FOR THE DETECTIO OF AFRICA SWI E FEVER VIRUS (ASFV) BY CO VE TIO AL POLYMERASE CHAI REACTIO (PCR)

Gene Expression Assays

Human Free Testosterone(F-TESTO) ELISA Kit

Wizard SV Gel and PCR Clean-Up System

Real-time quantitative RT -PCR (Taqman)

CompleteⅡ 1st strand cdna Synthesis Kit

Improved methods for site-directed mutagenesis using Gibson Assembly TM Master Mix

GenScript BloodReady TM Multiplex PCR System

Table of Contents. I. Description II. Kit Components III. Storage IV. 1st Strand cdna Synthesis Reaction... 3

Denaturing Gradient Gel Electrophoresis (DGGE)

PowerFecal DNA Isolation Kit

Reverse Transcription System

ptune Inducible Vector

GRS Plasmid Purification Kit Transfection Grade GK (2 MaxiPreps)

TITRATION OF raav (VG) USING QUANTITATIVE REAL TIME PCR

Transcription:

Macrogen Sample Submission Guide Macrogen has served over 10 years in sequencing field using the cutting edge technology and delivering fast and reliable results. We use high throughput Applied Biosystems 3730XL sequencers. We sequence all kinds of cloned DNAs (plasmids, cosmid, phages, BACs) as well as PCR-products. Macrogen provides a high quality DNA Sequencing service for academics, government, research institutions and private companies at Very Competitive Price. Please contact us for any inquiry. For more detailed explanations and recommendations about the preparation and submission of samples, please refer to the following link: http://dna.macrogen.com/eng/help/sample_submission.jsp For information regarding shipping specifications, please refer to the following link: http://dna.macrogen.com/eng/help/orderg.jsp To order the sequencing service, please access to our online ordering system and create an account; http://dna.macrogen.com/eng For payment information, please refer to the following link: http://dna.macrogen.com/eng/help/howtopay.jsp Contact Sequencing Inquiry: info@macrogen.com Payment Inquiry: payment@macrogen.com Technical Support S.H. Cha, Ph.D : chash@macrogen.co.kr Y.B. Kim, Ph.D : kyb9408@macrogen.com

Shipping Address (for Value Service, to Macrogen Inc.) Macrogen Inc. 908 World Meridian Venture Center, #60-24, Gasan-dong, Geumchun-gu, Seoul 153-781, Korea Tel : +82-(0)2-2113-7790 Fax : +82-(0)2-2113-7919 E-mail: info@macrogen.com Shipping Address (for European Express Service, to Macrogen Europe) Macrogen Europe IWO, Kamer IA3-195 Meibergdreef 39 1105 AZ Amsterdam Zuid-oost Netherlands Tel : +31-(0)20-566-5472 Mobile : +31-(0)6-8148-0760 E-mail: europe@macrogen.com Template Type/Format Sample Requirements Plasmid * 100 ng/µl * Minimum volume of 20µl * Agar Plate/Glycerol Stock 16S * gdna:30-50ng * Minimum volume of 20µl PCR Product * 50 ng/µl (Purified) * Minimum volume of 20µl PCR Product * 100 ng/µl (Unpurified) * Minimum volume of 30µl Difficult Sequence * 100 ng/µl * Minimum volume of 40µl Primer Walking * 8 µg (for an insert size of up to 4kb) Remarks For re-sequencing, at lease 5 µl is required. N/A For re-sequencing, at lease 5 µl is required. N/A N/A Single Strand Sequencing: 1 µg/1 kb insert. If insert size is longer than 4kb, clone is required in an agar stab culture status.

It is possible to send us either a stab or glycerol culture with the selected E.coli clone, the purified plasmid DNA or your unpurified or purified PCR product. Templates and primers must be provided in DI water or 10mM Tris buffer, not in TE a) Sample for individual tube : - General glycerol stock/ Agar-stab/Agar-plate culture at room temperature. - 1.5µl microcentrifuge tube is recommended in a dried (lyophilized) form or solution..(nuclease-free TE or distilled water) at room temperature.. - Free re-sequencing is included b) 96 Well Plate : - 8 strip cap is recommended in a dried (lyophilized) form or solution (Nuclease-free TE or distilled water).. at room temperature. * Note: The well to well variation of the concentration of your samples is very important to get better results, please keep it as constant as possible. Please place your samples properly into strip- capped well plate as shown below. Strip cap is Good! To avoid any physical damage, please use out-skirted well plate. Out-skirted well plate is Good!

Please seal tightly to avoid any potential damages in transit such as evaporation or contamination of samples during shipping. Enough volume and constant concentration at each well is the key factor for good results Bad sealing and leaking may lead crosscontamination and unsatisfactory results! - Re-sequencing for plate is additionally charged. ** In case of Multi primers for one plate ** Only two custom primers (or two universal primers) in tubes could be acceptable for applying this Plate sequencing. * Note : For three or more primers, another paired primer plate with your sample plate should be provided. If not, your order will be regarded as Normal sequencing reactions.

Template Preparation Guidelines 1) Template preparation The success of automated sequencing critically depends on having high purity template in the correct concentration. In case of samples in plates, constant concentration among wells is also important for the success of sequencings. i) Plasmid DNA Preparation There are many commercial kits available. Please submit DNA in deionized water. Do not use TE to dilute or re-suspend the DNA because EDTA inhibits the cycle of sequencing reaction We recommend using Qiagen miniprep/midiprep since both methods yield consistent purity of plasmid DNA for sequencing. Please provide DNA in the concentration range of 100ng/µl and in the amount of at least 2 µg. Extra amount of DNA ensures that we have enough sample for a re-sequencing in case the first reaction fails. If samples concentrations do not fall within this range or if you fail to provide us enough template to do the reaction, the experiment might be delayed. ii) PCR fragments Preparation The DNA is free of contaminants, unused primers or dntps. PCR templates that do not undergo any kind of post PCR clean up are not suitable for sequencing and will yield unusable sequence data. It is highly recommended that your PCR template is first observed on a gel to confirm that there is a specific product with the correct size. The Qiagen Gel extraction kit or PCR cleanup kit can be used to remove all of the unwanted elements from your template.

2) Primers preparation Primer Considerations Primers should be provided in DI water at the required concentration (see table above). - High Purity - Appropriate concentration - No secondary priming sites - No mismatches - A length of 18-25 bases. - GC% content between 40% and 60%. - A Tm (melting temperature) between 55 C and 60 C - No significant hairpins (>3bp) - Free of salts, EDTA, or other contaminants Please supply primers at concentration of (10 pmole/µl =60 ng/µl) in deionized water at volume of greater than 20 µl. Primers supplied by customers should be desalted or purified. Crude primers generally do not work well for sequencing. We have the following primers available at no extra charge. Primer Name Sequence Base T7 AATACGACTCACTATAG 17 T7terminator GCTAGTTATTGCTCAGCGG 19 T7promoter TAATACGACTCACTATAGGG 20 T3 ATTAACCCTCACTAAAG 17 SP6 ATTTAGGTGACACTATAG 18 M13F-pUC(-40) GTTTTCCCAGTCACGAC 17 M13R-pUC(-40) CAGGAAACAGCTATGAC 17 M13F(-20) GTAAAACGACGGCCAGT 17 M13R(-20) GCGGATAACAATTTCACACAGG 22 pgex5 GGCAAGCCACGTTTGGTG 18 pgex3 GGAGCTGCATGTGTCAGAGG 20 27F AGAGTTTGATCMTGGCTCAG 20 1492R TACGGYTACCTTGTTACGACTT 22 518F CCAGCAGCCGCGGTAATACG 20 800R TACCAGGGTATCTAATCC 18 ITS1 TCCGTAGGTGAACCTGCGG 19

ITS4 TCCTCCGCTTATTGATATGC 20 BGH-R TAGAAGGCACAGTCGAGG 18 CMV-F CGCAAATGGGCGGTAGGCGTG 21 RVprimer3 CTAGCAAAATAGGCTGTCCC 20 RVprimer4 GACGATAGTCATGCCCCGCG 20 GLprimer1 TGTATCTTATGGTACTGTAACTG 23 GLprimer2 CTTTATGTTTTTGGCGTCTTCCA 23 pqe-f CCCGAAAAGTGCCACCTG 18 pqe-r GTTCTGAGGTCATTACTGG 19 Gal4AD TACCACTACAATGGATG 17 pbad-f ATGCCATAGCATTTTTATCCA 21 pbad-r GATTTAATCTGTATCAGG 18 EGFP-CF AGCACCCAGTCCGCCCTGAGC 21 EGFP-CR CGTCCATGCCGAGAGTG 17 EGFP-NR CGTCGCCGTCCAGCTC 16 3) Host strains The host strain can have an impact on the quality of the template DNA prepared even using the best methods. DH5-α host strains consistently produce good results. HB101, XL-1 Blue, JM109 and MV1190 are usually fine but JM101 is often poor. The growth media you use can also affect the outcome yields, while LB is usually fine. 4) Quantitation Sequencers are able to handle a wide range of DNA concentrations however with very low amounts of DNA the data quality will be significantly affected. Using UV absorbance to quantitate dilute DNA solutions tends to give widely inaccurate results. A good way to quantitate DNA is to run an aliquot on a minigel and compare the intensity to the control of a known concentration. There are also concentration ladders that are commercially available. For each reaction, please provide 10 ng/100 bases, and at least 20 ng/µl solution in deionized water. Please provide at least 10 ul for any possible re-sequencing. Please be advised that "Gel Electrophoresis rather than Nano-drop "is recommended