Radiation Safety Committee College of William and Mary



Similar documents
Ch. 227 ANALYTICAL X-RAY EQUIPMENT 25

PART H RADIATION SAFETY REQUIREMENTS FOR ANALYTICAL X-RAY EQUIPMENT. Definitions. As used in this Part, the following definitions apply:

X-ray Safety Manual 2013

Revision Date September, X-Ray Safety Program. Environmental Health and Safety Radiation Safety

LASER SAFETY MANUAL UNIVERSITY OF KENTUCKY POLICIES AND PROCEDURES FOR LASER USERS REVISED EDITION 2012 ISSUED BY

Analytical X-ray Safety Refresh Training. Radiation Safety Officer Department of Environmental Health and Safety

X-ray Radiation Safety Course. James Kane & Rob Deters Office of Radiological Control

Safety and Radiation Protection Office Working with X-Ray Equipment

DEPARTMENT OF ENVIRONMENT, HEALTH & SAFETY RADIATION SAFETY DIVISION. University of California, Los Angeles RADIATION SAFETY GUIDANCE

LASER SAFETY PROGRAM FOR CANISIUS COLLEGE (Department of Chemistry and Biochemistry) Effective: October 1, 2007 Revised: June 3, 2010

Required RS Training Info

Rice University Laser Safety Manual

Laser Safety Self-Audit Checklist

PART B REGISTRATION [LICENSURE] OF RADIATION MACHINE FACILITIES, [SERVICES] */ AND ASSOCIATED HEALTHCARE PROFESSIONALS

Northern Illinois University Laser Safety Program

The University of Southern Maine. XRF X-Ray Radiation Protection Program

Satellite Laser Ranging (SLR) International Workshop Safety Best Practices Discussion Clinic Group Chris Quinn

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

INTEL S SAFETY WARNING LABEL REQUIREMENTS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

Radiation Safety Issues for Radiologic Technologists

EPA Protocols: Compliance testing of dental X-ray apparatus used for plain radiography

THE UNIVERSITY OF TEXAS MEDICAL BRANCH LASER SAFETY MANUAL ENVIRONMENTAL HEALTH & SAFETY

Environmental Health and Safety. Laser Safety Guide. Environmental Health and Safety

Status of a Draft Standard for Personnel Screening Systems ANSI/HPS Subcommittee N

HSE information sheet Industrial radiography - managing radiation risks Ionising Radiation Protection Series No. 1(rev 1)

Regulatory Guide. Radiation Safety in Industrial Radiography (FANR-RG-019) Version 0

(2) "Interlock" means a device preventing the start or continued operation of equipment that could cause a radiation hazard.

Radiation Rule Guide. Veterinary Facilities. Hawaii Administrative Rules, Chapter 11-45, Radiation Control. Hawaii State Department of Health

X-RAY REGULATORY GUIDE

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

FACILITY SAFETY SIGNAGE GUIDE: 10 SIGNS TO SPOT DURING A PLANT WALKTHROUGH

QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES. (a) Applicability. (b) Definitions

X-RAY OPERATOR TRAINING

RADIATION PROTECTION PROGRAM (RPP) GUIDANCE

RADIOACTIVE WASTE MANAGEMENT PLAN

Dose Standards and Methods for Protection. Radiation and Contamination

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

Engineered and Administrative Safety Systems for the Control of Prompt Radiation Hazards at Accelerator Facilities. Introduction

25 TEXAS ADMINISTRATIVE CODE Registration of Radiation Machine Use and Services. Texas Regulations for Control of Radiation

LASER SAFETY PLAN. The Hamilton Eye Institute at The University of Tennessee 930 Madison Avenue Memphis, Tennessee 38163

APP C1 NAVAL RADIOACTIVE MATERIAL PERMIT REVIEW CHECKLIST NUCLEAR MEDICINE COMMAND: PERMIT NUMBER: TYPE OF ACTION:

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT

General requirements. 1. Administrative Controls.

GUIDE FOR THE PREPARATION OF RADIOACTIVE MATERIAL APPLICATIONS FOR WELL LOGGING OPERATIONS IN KENTUCKY

Radiation Safety Training

Agency for Health Care Administration

EMERGENCY PROCEDURES FOR RADIOACTIVE MATERIAL. 2. Prevent the spread of contamination by covering the spill with absorbent paper.

Security Imaging Systems (X-Ray): Design, Measurements Regulations, and Standards

RADIATION SAFETY STANDARD

NEW JERSEY RADIOLOGIC TECHNOLOGY BOARD OF EXAMINERS (BOARD) ACCREDITATION STANDARDS FOR SCHOOLS OF DENTAL RADIOLOGIC TECHNOLOGY

Rigaku XRD-System Instruction Manual v4/19/03. The Krishnan Group/Wilcox 132, University of Washington

USE OF IONIZING RADIATION IN THE TEACHING OF PHYSICS AND CHEMISTRY

Machine Guarding and Operator Safety. Leader Guide and Quiz

Standards for accreditation of educational programs and approval of continuing education courses.

XRS-4 X-RAY SOURCE OPERATOR S MANUAL

X-ray Imaging Systems

Performance-Based Inspection Field Guide

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Department of Environmental Health & Safety. Lock Out/Tag Out Program. Date Effective: November 2010

Status of Radiation Safety System at

IMPORTANT SAFETY NOTICE

notes MERRTT IS-302 Radiological Survey Instruments and Dosimetry Devices

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

RIGAKU MINIFLEX II. Standard Operating Procedure (SOP)

IAC Ch 41, p.1. Procedure means a stereotactically guided breast biopsy performed on a patient for diagnostic purposes.

Laboratory Safety and Environmental Health Assessment Program

Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited

have been provided with information on whether they do or do not contain asbestos before starting work;

Image Quality and Radiation Dose for Intraoral Radiography: Hand-Held Held (Nomad), Battery Powered

portable x-ray survey report

In the previous presentation, we discussed how x-rays were discovered and how they are generated at the atomic level. Today we will begin the

Installation Instructions

PowlVac Vacuum Integrity Tester

Quality Assurance. The selection of the equipment. Equipment Specifications. Medical Exposure Directive 97/43 Euratom. Quality Assurance Programme

PART 34--LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS

SUMMARY OF CURRENT UK LEGISLATION AND GUIDELINES

Application Note. ipix A Gamma imager to support various applications

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

Process Safety Management Program

NEW JERSEY RADIOLOGIC TECHNOLOGY BOARD OF EXAMINERS (BOARD) ACCREDITATION STANDARDS FOR SCHOOLS OF RADIATION THERAPY TECHNOLOGY

Harvard University Radiation Safety Manual

Educational Tool for Medical Laser Programs 1. Laser Safety

Hazards in the Use of X-Ray Analytical Instrumentation R. Jenkins and D. J. Haas Philips Electronic Instruments, Mount Vernon, New York, U.S.A.

X-ray Operating Procedures and Safety Manual

Ultrasound Condition Monitoring

PERSONNEL MONITORING AND DOSIMETRY POLICIES

Replace the Pump Tube Classic

105 CMR: DEPARTMENT OF PUBLIC HEALTH

Example of SOP for IR Laser

Preface. Consult the current Laser Safety Officer at for specific information.

OPTIONAL INFORMATION ELECTRICAL SAFETY WORK PRACTICES SELF INSPECTION CHECKLIST

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

GEORGIA INSTITUTE OF TECHNOLOGY ENVIRONMENTAL HEALTH AND SAFETY PERSONAL PROTECTIVE EQUIPMENT

American National Standard

SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective

XR200 X-RAY SOURCE OPERATOR S MANUAL

EMERGENCY EYE WASH FACILITY POLICY. Under the Occupational Health and Safety Regulations of the Province of Newfoundland and Labrador

OPNAVINST B MCO C 2 May 2008 LASER SAFETY DESIGN REQUIREMENT CHECKLISTS

Transcription:

Radiation Safety Committee College of William and Mary Policy for the operation of Analytical X-ray Equipment The following rules govern the use of analytical X-ray equipment at the College of William and Mary. These rules comply with the radiation safety standards recommended by the Commonwealth of Virginia and the American National Standards Institute (ANSI). Open and Enclosed-Beam Analytical Systems The following are requirements for both open-beam and enclosed-beam analytical X- ray systems. 1. Warning Lights An easily visible warning light labeled "X-RAY-ON" shall be located near any switch that energizes an X-ray tube. It is to be illuminated only when the tube is energized. This light shall be of a fail-safe design. 2. Labeling All analytical X-ray equipment shall be labeled with a conspicuous sign or signs that bear the radiation symbol and the words (or similar words): 1. "CAUTION - HIGH-INTENSITY X-RAY BEAM" on the X-ray source housing. 2. "CAUTION - RADIATION - THIS EQUIPMENT PRODUCES RADIATION WHEN ENERGIZED" near any switch that energizes an X-ray tube. 3. Beam trap A beam trap or other primary beam shield shall be provided to intercept the primary beam. Additional Requirements for Enclosed-Beam Systems 1. Chamber The X-ray tube housing, sample detector, and analyzing crystal shall be enclosed in a chamber (or coupled chambers) that prevents entry of any part of the body.

2. Ports Access ports to the sample chamber shall be of a fail-safe design that prevents X-ray generation or entry of the X-ray beam into the chamber when any port is opened. Additional Requirements for Open-Beam Systems 1. Safety device An interlocked safety device, which prevents entry of any part of the body into the primary beam or causes the beam to shut off, shall be provided on all open-beam systems. An authorized user may seek an exemption from this requirement by applying to the Radiation Safety Officer. The application shall include: 1. A description of the safety devices evaluated and why they cannot be used. 2. A description of the alternative method that will be used to minimize the possibility of an accidental overexposure. 3. Procedures that will be used to alert personnel to the absence of a safety device. 2. Warning devices Open-beam systems shall be provided with the following warning devices: 1. X-ray tube status (ON-OFF) located near the X-ray source housing, if the primary beam is controlled in this manner; and/or, 2. Shutter status (OPEN-CLOSED) located near each port on the X-ray source housing, if the primary beam is controlled in this manner. These devices shall be readily visible and properly labeled as to their purpose. Warning devices shall have fail-safe characteristics. 3. Shutters Shutters at unused ports shall be secured in the closed position to prevent accidental opening. 4. Ports Each port on the X-ray source housing shall be equipped with a shutter that cannot be opened unless a collimator or other device has been connected to the port, if the system was installed after January 1, 1980. Training All individuals independently operating analytical X-ray equipment shall be designated as Restricted Users and shall receive instructions in and demonstrate ability in:

1. General properties of ionizing radiation. 2. Principles of radiation detection. 3. Radiation hazards associated with the use of the equipment. 4. Biological effects of ionizing radiation. 5. Procedures to minimize exposure. 6. Proper operating procedures for the equipment. 7. Purposes and functions of the radiation warning and safety devices incorporated into equipment. 8. Proper procedures for reporting an actual or suspected over-exposure. Ability shall be demonstrated by passing a written examination administered by the Radiation Safety Officer. Exceptions to radiation safety training will not be granted because of previous education, training, or experience. Operating Procedures 1. Procedure Manual - Normal operating procedures shall be written and available to all analytical X-ray equipment users. Analytical X-ray equipment shall not be operated differently from that specified in the procedure manual unless written permission has been obtained from the Radiation Safety Officer (RSO). 2. Bypassing Safety Device - A safety device shall not be bypassed unless written approval has been obtained from the Radiation Safety Officer. This approval shall be for a specified time. When a safety device has been bypassed, a conspicuous sign shall be placed on the X-ray housing bearing the words (or similar words), "SAFETY DEVICE NOT WORKING." Radiation Limits Enclosed-beam systems The exposure rate during normal operations shall not exceed 2.5 mrem/hr at a distance of 5 cm from the protective chamber walls. Open-beam systems The exposure rate at the maximum rated current and voltage with all shutters closed shall not exceed 2.5 mrem/hr at a distance of 5 cm from the X-ray tube housing. Generator Cabinet The exposure rate at a distance of 5 cm from the surface of the X-ray generator cabinet shall not exceed 0.25 mrem/hr. During normal operations in restricted areas, scattered radiation levels in accessible areas in any one hour shall not exceed 37.5 mrem to the hands or 2.5 mrem to the whole body. During alignment procedures, the dose equivalent to the hands in any 1 hour shall not exceed 37.5 mrem. The local parts of an analytical X-ray system shall include sufficient shielding and be so located and arranged so exposure rates in unrestricted areas do not exceed 2 mrem/hr, or 100 mrem in 7 consecutive days, or 500 mrem/yr.

Personnel Monitoring All workers shall wear a whole-body personnel monitoring device during the operation of the equipment. Finger dosimetry devices shall be worn by all personnel working with open-beam analytical X-ray equipment. The College of William and Mary has adopted procedures to keep the exposure to radiation As Low As Reasonable Achievable (ALARA). These procedures employ the practices of reducing the TIME of all exposures, keeping the greatest practical DISTANCE from all sources, using SHIELDING when ever possible, and preventing any exposure to individuals that is greater that 125mR per quarter or totaling more than 500 mr per year. Surveys Radiation surveys shall be performed and documented by the Radiation Safety Officer, or alternate RSO: 1. On installation of the equipment and at least once every year thereafter to monitor leakage radiation. 2. On at least an annual basis to monitor area radiation levels when the equipment is operating. Radiation surveys with a meter capable of detecting x-ray shall be performed and documented by the Restricted User who is approved and supervised by the Radiation Safety Officer or Alternate RSO: 1. Following any change in the initial arrangement, number or type of local parts. 2. Following any maintenance that requires the disassembly or removal of a local part. 3. During the performance of maintenance and alignment procedures that require the presence of a primary beam and the disassembly or removal of a local part. 4. When a visual inspection of the local parts reveals an abnormality. Each area or room containing open-beam analytical X-ray equipment shall be equipped with a suitable radiation survey instrument. 5. To accomplish the required surveys an appropriate survey meter will be available within the facility during all operations. The documentation of all of the surveys described in points 1 through 4 above, will be maintained in the laboratory with the instrument for inspection by the RSO and by the Commonwealth of Virginia. Repair and Alignment Procedures The following safety precautions shall be taken to reduce risks during repair and alignment procedures:

1. The main switch, rather than the safety interlocks, shall be used to shut down the equipment. 2. No X-ray tube shall be used without a suitable housing to restrict the radiation to a well-defined beam. 3. A sign stating "Interlocks Not Working" must be posted on the equipment when the interlocks have been defeated for alignment purposes. 4. Alignment procedures, other than those recommended by the manufacturer, must be approved by the Radiation Safety Officer. 5. Alignment procedures must be written and available to all users. 6. If the dose rate in an unrestricted area is exceeded during the repair or alignment procedure, temporary barriers must be set up and the area must be properly posted. The area shall be kept under surveillance until normal operations have been restored. 7. After re-assembly, the X-ray equipment shall be checked for leakage radiation by the Radiation Safety Officer or the Restricted User. The following safety precautions should be taken to reduce risks: 1. The smallest practical voltage and current should be used during the alignment procedure. 2. Long-handled tools and extension devices should be used to reduce the risk of the hand entering the beam. 3. Protective glasses should be worn during alignment procedures. 4. Temporary shielding should be added to reduce scattered radiation levels to a minimum. 5. Alignment procedures recommended by the manufacturer should be used. 6. Two-man teams should be used during alignment procedures. One person should make the adjustments while the other person watches for safety problems. Adopted: 2-21-05 Todd Averett, RSO Eric Bradley, RSO, alt Dennis Manos, Vice Provost This text was extracted and adapted from: http://www.ehss.vt.edu/index.htm with the permission of Doug Smiley, Co-director, Environmental, Health, and Safety Services, Virginia Tech smileydc@vt.edu