300 MW Variable Speed Drives for Pump-Storage Plant Application Goldisthal



Similar documents
SYNCHRONOUS MACHINES

WIND TURBINE TECHNOLOGY

Power Electronics. Prof. K. Gopakumar. Centre for Electronics Design and Technology. Indian Institute of Science, Bangalore.

Principles of Adjustable Frequency Drives

Dually Fed Permanent Magnet Synchronous Generator Condition Monitoring Using Stator Current

LOSSELESS STARTING METHOD FOR THE WOUND ROTOR INDUCTION MOTOR

8 Speed control of Induction Machines

Control Strategies of the Doubly Fed Induction Machine for Wind Energy Generation Applications

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

Advance Electronic Load Controller for Micro Hydro Power Plant

SFC Start-up inverter of gas turbo-sets Integrated compact units

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

FREQUENCY CONTROLLED AC MOTOR DRIVE

Control Development and Modeling for Flexible DC Grids in Modelica

EMTP STUDIES PERFORMED TO INSERT LONG AC CABLES IN THE FRENCH GRID

Mechanical and electrical rebuilding of a turbine generator for phase-shift operation

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

Induction Motor Theory

Simulation and Analysis of Parameter Identification Techniques for Induction Motor Drive

DC TRANSMISSION BASED ON VOLTAGE SOURCE CONVERTERS

Modelling, Simulation and Performance Analysis of A Variable Frequency Drive in Speed Control Of Induction Motor

Unit 33 Three-Phase Motors

Synchronous motor. Type. Non-excited motors

Basics of Electricity

Transient analysis of integrated solar/diesel hybrid power system using MATLAB Simulink

Analysis, Calculation and Reduction of Shaft Voltage in Induction Generators

The design and performance of Static Var Compensators for particle accelerators

6. Synchronous machine dynamics

Reactive Power Control of an Alternator with Static Excitation System Connected to a Network

Power Quality Paper #3

Large Generators and High Power Drives

Lecture 4 Energy Conversion in Wind Turbine

C Standard AC Motors

Motor Fundamentals. DC Motor

Requirements for Offshore Grid Connections. in the. Grid of TenneT TSO GmbH

Mathematical Modeling and Dynamic Simulation of a Class of Drive Systems with Permanent Magnet Synchronous Motors

Chapter 3 AUTOMATIC VOLTAGE CONTROL

IV. Three-Phase Induction Machines. Induction Machines

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Smart Grid and Renewable Energy Grid Integration. Jian Sun, Professor and Director Department of ECSE & Center for Future Energy Systems

Renewable Energy Applications: Photovoltaic and Wind Energy Conversion Systems (WECS)

How to Turn an AC Induction Motor Into a DC Motor (A Matter of Perspective) Steve Bowling Application Segments Engineer Microchip Technology, Inc.

Simulation of VSI-Fed Variable Speed Drive Using PI-Fuzzy based SVM-DTC Technique

MICRO HYDRO POWER PLANT WITH INDUCTION GENERATOR SUPPLYING SINGLE PHASE LOADS

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.

Cahier technique no. 196

System Protection Schemes in Eastern Denmark

Low Frequency AC Transmission System

NO LOAD & BLOCK ROTOR TEST ON THREE PHASE INDUCTION MOTOR

Renewable Energy Grid Integration

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

CO-ORDINATION OF PARALLEL AC-DC SYSTEMS FOR OPTIMUM PERFORMANCE

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR

Electric Power Systems An Overview. Y. Baghzouz Professor of Electrical Engineering University of Nevada, Las Vegas

ABB PSPS Erich Steinmann; Generator control-2013

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.

INDUCTION REGULATOR. Objective:

R448 & R448 V50 A.V.R.

EDUMECH Mechatronic Instructional Systems. Ball on Beam System

Verification of Short Circuit Test Results of Salient Poles Synchronous Generator

Technical Guide No High Performance Drives -- speed and torque regulation

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

Development of the Induction Motor for Machine Tool Spindles and Servo Amplifier SANMOTION S

Power System review W I L L I A M V. T O R R E A P R I L 1 0,

SVC LIGHT: A POWERFUL MEANS FOR DYNAMIC VOLTAGE AND POWER QUALITY CONTROL IN INDUSTRY AND DISTRIBUTION.

*ADVANCED ELECTRIC GENERATOR & CONTROL FOR HIGH SPEED MICRO/MINI TURBINE BASED POWER SYSTEMS

Power Plant Electrical Distribution Systems

Control of a Three Phase Induction Motor using Single Phase Supply

Modeling and Simulation of a Novel Switched Reluctance Motor Drive System with Power Factor Improvement

What Is Regeneration?

Introduction. Chapter The Motivation

THIS paper reports some results of a research, which aims to investigate the

Three phase circuits

Simulation of Ungrounded Shipboard Power Systems in PSpice

Rotating Machinery Diagnostics & Instrumentation Solutions for Maintenance That Matters

operating under normal conditions supplying - isolated loads - an infinite bus - a fin1 te bus load.

Excitation.

Application for Small Generator Facility Interconnection Tier 2, Tier 3 or Tier 4 Interconnection

Modeling Grid Connection for Solar and Wind Energy

Renewable Energy Laboratory for Engineering Students

FULL ELECTRICAL LNG PLANTS: HIGHEST AVAILABILITY AND ENERGY EFFICIENCY THROUGH OVERALL SYSTEM DESIGN

A.V.R. R250. Installation and maintenance R250 0V E+ E- VOLT STAB FREQ. & L.A.M. CONFIG. 50Hz. 47.5Hz. 57Hz LAM 1 13% 2 25% OFF LAM OFF 9

Advanced Protection of Distribution Networks with Distributed Generators

PHASE CONVERSION TECHNOLOGY OVERVIEW

Stepper motor I/O. Application Note DK Motion Control. A General information on stepper motors

525-MVA Generator-motor and Thyristor Starter Put into Service at the Tokyo Electric Power Co., Inc. s Kannagawa Hydroelectric Power Station

This document contains information proprietary to Mitsubishi Electric Corporation. It is submitted in confidence and is to be used solely for the

2012 San Francisco Colloquium

Simulation of Electric Drives using the Machines Library and the SmartElectricDrives Library

Modeling and Simulation of a Large Chipper Drive

Analysis of Space Vector Pulse Width Modulation VSI Induction Motor on various conditions

13 ELECTRIC MOTORS Basic Relations

Special Publication. Operation and Monitoring of MSCDN-Systems

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

DIMENSIONING OF CURRENT TRANSFORMERS FOR PROTECTON APPLICATION

FACTS. Solutions to optimise network performance GRID

Adıgüzel Hydroelectric Power Plant Modeling and Load-Frequency Control

R438 A.V.R. Installation and maintenance R 438. This manual is to be given to. the end user T10. Armature 6- Field X2 Z1 X1 Z2 E+ E- 0V

Transcription:

May 24 MW Variable Speed Drives for Aurélie Bocquel APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT

MW Variable Speed Drives for Content Major benefits of the cyclo-converter driven doubly-fed induction machines Topology of the pump storage power station Cyclo-converter topology Mathematical model and simulation Power flow at constant torque in turbine and pump operation P/Q-diagram of the induction machine at different speeds and at the limits of the cyclo-converter Control structure of the doubly-fed induction machine with cycloconverter Measurement results (torque steps, synchronisation, speed variation) Conclusions APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT / A.BOCQUEL / Be 2

MW Variable Speed Drives for Principle of a pump-storage plant Goldisthal Maximum dam level Minimum level Amount of exchanged water Maximum dam level Minimum level APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT / A.BOCQUEL / Be

MW Variable Speed Drives for Major benefits of the cyclo-converter driven doubly-fed induction machines The efficiency of the turbine especially at partial loads can be increased by optimising the speed of operation. 8 kv, 5 Hz 8 kv, 5 Hz 8 kv, 5 Hz The converter only needs to supply about % of the total power of the machine; compared to a fully fed solution the installed power and the converter losses are reduced. The delivered power of the induction motor can be controlled with a high dynamic which is advantageous for grid stabilisation. 18 kv 18 kv IM SM 18 kv 18 kv Single-line diagram of Goldisthal pump-storage station 4 turbines with a power of about MVA each 2 of the electrical machines are designed as converter driven doubly-fed induction machines The converter feeding the rotor of the machine is with a power of 1 MVA one of the biggest cyclo-converters in the world SM IM APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT / A.BOCQUEL / Be 4

MW Variable Speed Drives for Machine cavern Goldisthal - different phases of the construction APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT / A.BOCQUEL / Be 5

MW Variable Speed Drives for Machine cavern Goldisthal Rotor of the induction motor under construction APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT / A.BOCQUEL / Be 6

MW Variable Speed Drives for Machine cavern Goldisthal Assembly of the rotor of the induction machine, stator completed APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT / A.BOCQUEL / Be 7

MW Variable Speed Drives for Topology of the pump storage power station 4 turbines which can work in pumping and generating mode 2 turbines equipped with synchronous machines (1 MVA generative power each) : classical excitement operation close to their rated power high efficiency fixed speed 2 turbines connected to doubly-fed induction machines (4.4 MVA generative power each) dynamic power control controlled with the cyclo converter speed range of 1 % to +4 % of rated speed optimisation of the efficiency varying the speed operation at partial loads efficient 2 start-up converters of 4 MW of rated power each can start and stop the synchronous and induction machines each converter can be connected to each of the 4 machines during start up the cyclo converter excites the induction machine current source converters 24 pulse thyristor bridge on the line side 6 pulse thyristor bridge on the machine side APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT / A.BOCQUEL / Be 8

MW Variable Speed Drives for Cyclo-converter topology 18 kv, 5 Hz Y D D Y DC choke (see next slide) Y D D Y Y D D Y crow bar crow bar crow bar Cubicle carrying three independent 12 pulse thyristor bridges (width/depth/height in mm: 4 / 14 / 24) rated current: 897 A rated voltage: 716 V neutral point Doubly-fed induction motor (generator) 1 MVA cyclo-converter for the doubly-fed induction machine Each phase of the rotor of the induction machine is fed by two antiparallel 12 pulse thyristor bridges The anti parallel bridges drive circulating current to avoid overvoltages parallel thyristor bridges carry the rated current 1 of these is provided for redundancy (a failing bridge is disconnected via the pyrobreakers) Crow bars on the output protect the thyristors against overvoltages and can take over overcurrents generated by the machine APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT / A.BOCQUEL / Be 9

MW Variable Speed Drives for DC chokes The DC chokes driving the circulating current improve the protection of the converter Rated current: 665 A APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT / A.BOCQUEL / Be 1

MW Variable Speed Drives for Mathematical model and simulation Detailed modelling of the cyclo-converter (72 Thyristors), the crow bars, the induction machine and the grid Simulation together with the drive control Importance of the simulation design and verification of the power components and protection design and verification of the converter control calculation of the line distortions i B R L L R i B s s s r r r Grid u s B s B j sb B s L h r B r B j rb u r B Cycloconverter Schematic model of the induction motor (generator) APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT / A.BOCQUEL / Be 11

MW Variable Speed Drives for Simulation results of a three-phase short circuit in the grid Due to the short circuit the rotor current rises quickly and reaches the overcurrent limit of the crow bars. rotor currents [ka] rotor voltages [kv] 1 5-5 -1 5 25 - -6 The crow bar is triggered and the pulses of the cyclo-converter are shifted to the end position. The fired crow bar greatly reduces the voltage at the cyclo-converter and takes over the largest part of the rotor current. cycloconverter currents [ka] crow bar currents [ka] 2 1-1 -2 5 25-25 -5.5.1.15 t [s] APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT / A.BOCQUEL / Be 12

MW Variable Speed Drives for Power flow at constant torque in turbine and pump operation 1/2 P grid P CYC P grid P grid P grid P CYC P grid P CYC P CYC P CYC P s P s Air gap IM P D converter+ Transformer P s Air gap IM P D converter+ Transformer P s Air gap IM P D converter+ Transformer P s Air gap IM P D converter+ Transformer P r P r P r P D P r P mech P mech P mech P mech P r n -n max n s = -n syn -n min P r, P s, P mech subsynchronous Assumption T = T Nom oversynchronous P mech n P r = P s -1 n s n P s P mech 2 P mech = n T 6 P s -P Nom P Nenn P mech Assumption T = T Nom n P r = P s -1 n s oversynchronous subsynchronous P r, P s, P mech n min n s = n syn n max n Turbine operation Pump operation 1 APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT / A.BOCQUEL / Be

MW Variable Speed Drives for Power flow at constant torque in turbine and pump operation 2/2 The doubly-fed induction machine can operate in a wide speed range related to the rating of the cyclo-converter Turbine operation: The mechanical power delivered from the turbine is converted into electrical active power generated in the stator (P s ) through the air gap of the machine and partly in the rotor (P r ) Oversynchronous turbine operation: Thanks to the cyclo-converter, the active power in the rotor can be added to the stator power to generate the active grid power (P grid ). Subsynchronous turbine operation: the cyclo-converter feeds the rotor with part of the active stator power necessary to generate the mechanical power. Induction machine at synchronous speed: no active power is generated in the rotor P s is equal to the mechanical power excitement by the cyclo-converter with constant current like a synchronous machine. The reactive power of the induction machine can be controlled independent of the active power by the cyclo-converter. APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT / A.BOCQUEL / Be 14

MW Variable Speed Drives for Simulation of a speed variation at constant torque in pump operation At steady state operation the rotor flux amplitude and the magnetising current of the stator are constant. With constant torque, the rotor current amplitude is constant and independent of the slip of the machine The rotor voltage amplitude varies linearly with the angular velocity of the rotor flux vector related to the rotor angle. rotor voltages [kv] rotor currents [ka] machine speed [%] 5 2.5-2.5-5.2.4.6.8 1 1.2 15 7.5-7.5-15.2.4.6.8 1 1.2 14 1 95 9.2.4.6.8 1 1.2 t [s] APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT / A.BOCQUEL / Be 15

MW Variable Speed Drives for P/Q-diagram of the induction machine at different speeds and at the limits of the cycloconverter Advantages of the doubly-fed induction machine: Control of torque and flux with a high dynamic in all operation modes Stable operation in all operation modes within the limits of the converter depicted by the P/Q circles Note: Operation of synchronous machines close to those power limits (e.g. with large rotor flux angles) can lead to instabilities The circles are determined by the maximum current of the cyclo-converter In the range of capacitive reactive power the power is limited by the maximum output voltage of the converter Q [MVAR] 7 6 5 4 2 1-1 -2 - n = 16 % 5 rpm n 46 rpm o n = 14 % n o 295 rpm rpm n = 88,5 % -4-5 -4 - -2-1 1 2 4 5 P [MW] n o n = 9 % stator voltage: 18 kv, grid frequency: 5 Hz, maximum rotor current and maximum rotor voltage n o APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT / A.BOCQUEL / Be 16

MW Variable Speed Drives for Control structure of the doubly-fed induction machine with cyclo-converter r * u n (L1L2, L2L) u s(r,s,t) Flux oriented control based on a flux observer (extended Kalman filter) T* ^ r rs Synchronisation Control Speed Limitation estimating the amplitude and angle of the flux in the machine. ' r* ^ r T'* ^ T ^ r Flux Control Torque Control i (m) * i (l) * * sync ^ r 2 rs Voltage Feed Forward i * (m,l) u ro(m,l) Current Control i k(r,s,t) i r(r,s,t) ^ ^ un un 2 PLL-Grid 6 control set n,p(r,s,t) Calculation of Circulating & Rotor Current u n(l1l2, L2L) S i i rp(r,s,t) i rn(r,s,t) 76 6 4 Torque calculation using the estimated flux. Synchronisation control: control of the flux of the machine with the cycloconverter until electrical synchronisation between the stator voltage and the grid is reached synchronisation below the synchronous speed possible to reduce the start-up procedure duration the line breaker is closing with damped transient currents and resulting torque jerks ^ r ^ r T^ Q cos Flux and torque observer Power Calculation i r(r,s,t) ur(r,s,t) rs Rotor u s(rs,st,tr) i s(r,s,t) ASM T R APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT / A.BOCQUEL / Be 17

MW Variable Speed Drives for Current control structure of the cyclo-converter The reference rotor reactive current and torque generating current are transformed into rotor coordinates and compared to the calculated rotor current components i r by the rotor current controller using voltage feedforward estimating the rotor voltage increases the dynamic of the current control u r(r,s,t) * i r (R,S,T) i r (R,S,T) * i r_circ (R,S,T) i r_circ (R,S,T) rotor current control circulating current control u* r(r,s,t) calculation of switching angle u * r_circ (R,S,T) calculation of circulating & rotor currents u n(l1l2,l2l) p(r,s,t) PLL and control set n(r,s,t) i rp (R,S,T) i rn (R,S,T) S i 6 6 S ni 1 circulating current controller is only activated if the rotor current is near zero * reference values IM APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT / A.BOCQUEL / Be 18

MW Variable Speed Drives for Torque steps - simulation and measurement Torque [MNm] Rotor voltages [kv] 1 5.2.25..5.4.45.5 5-5.2.25..5.4.45.5 This dynamic performances of the drive can be used to dampen active power oscillations in the grid. 2 knm/div Rotor currents [ka] 1-1.2.25..5.4.45.5 Bridge currents (1 ph) [ka] 1-1.2.25..5.4.45.5 t [s] Simulation of a torque step from zero to the rated torque APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT / A.BOCQUEL / Be t [2 ms / Div] Measurement of a torque step on site (about 4% of rated torque) 19

MW Variable Speed Drives for Connection to the grid at 95 % of the rated speed At the end of the starting-up of the induction machine, the cyclo-converter is synchronising the stator voltage to the grid When electrical synchronisation is reached the line breaker at the stator of the machine is closed. The transient currents and resulting torque jerks after closing the breaker are well dampened and disappear after about 5 ms Compared to a synchronous machine this drive can synchronise much faster to the grid the start-up time can be reduced by accelerating the rotor to only 92 % of the synchronous speed and synchronising to the grid with the cyclo-converter 2-2 15 5-5 5-5 11-11 stator phase current [A] rotor phase current [A] reactive power [MVar] active power [MW] torque [knm] 12:59:1,5 12:59:2, t [25 ms / Div] Measurement of the drive behaviour while closing the line breaker after synchronisation at almost 95 % of the synchronous speed h:min:s APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT / A.BOCQUEL / Be 2

MW Variable Speed Drives for Speed variation at turbine operation with MW Each of the 2 water pipes in Goldisthal is feeding 1 pair of turbines, consisting of one induction machine and one synchronous machine. The induction machine is running in turbine operation at about MW (rated torque: 9 knm). the synchronous machine is taken out of operation and the water pressure of the turbine of the induction machine is changing drastically the delivered power of the cycloconverter driven induction machine is kept constant to MW by changing the speed of the turbine. 15-15 5-5 5-5 11-11 rotor phase current [A] reactive power [MVar] active power [MW] torque [knm] 15:58:4 15:58:45 15:58:5 15:58:55 15:59: t [2,5 s / Div] Measurement of dynamical speed variations caused by a load rejection of the synchronous machine around the synchronous point (turbine operation with MW) h:min:s APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT / A.BOCQUEL / Be 21

MW Variable Speed Drives for Conclusion 1 / 2 advantages of the cyclo-converter driven induction machine drive compared to a synchronous machine drive Cyclo-converter Driven Induction Machine Synchronous Machine with Standard Excitement Step response time (P, Q) (zero to rated) 15 ms several seconds Synchronisation time Synchronisation transient reactions 1 s damped after 5 ms 2 s or more depending on mechanical load conditions damped after several seconds Average efficiency of the whole storage unit (turbine + drive) 8 % 7 % APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT / A.BOCQUEL / Be 22

MW Variable Speed Drives for Conclusion 2 / 2 A MVA doubly-fed cyclo-converter driven induction machine drive for the pump-storage station Goldisthal was successfully put in operation. The cyclo-converter only needs to drive a third of the total power of the machine at the most. The efficiency of the turbine is increased by varying the speed ( 1 % to 4 %). The high-dynamic flux oriented control (torque step response time <1 ms) can be employed for a very fast power control for the stabilisation of the grid. Application of the drive system could also be advantageous for pumpstorage stations with much less power (e.g. 5 to 1 MVA). Shaft between the induction machine and the turbine APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT / A.BOCQUEL / Be 2

www.powerconv.alstom.com