Why Does the Relief Valve Open?



Similar documents
Sample Exam Questions and Recommended References for ABC s Backflow Prevention Assembly Tester Exam

Reduced Pressure Principle Assembly 3 Valve Procedure

Undersizing Backflow Preventers

Installation, Maintenance, & Repair Series 4000B/LF4000B

Changing a DC to an RP in the Field

Cross-Connection Control. Protecting the potable water supply from contamination.

Installation, Maintenance, & Repair Series 909 and LF909 Reduced Pressure Zone Assemblies

CROSS-CONNECTION CONTROL MANUAL

A Cross-Connection is a. water system and a nonpotable CROSS-CONNECTION CONTROL BACKFLOW PREVENTION CROSS-CONNECTION CROSS-CONNECTION

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Miami Dade County. Miami Dade Water & Sewer Department. Cross Connection Control Program 2/27/2015

Installation, Maintenance, & Repair Series 909, LF909, 909RPDA, LF909RPDA Reduced Pressure Zone Assemblies Reduced Pressure Detector Assemblies

(a) Purpose. The purpose is to safeguard potable water supplies by preventing backflow into public water systems.

CROSS-CONNECTIONS AND BACKFLOW PREVENTION MANUAL

PRESSURE REDUCING CONTROL VALVE

ALBUQUERQUE BERNALILLO COUNTY WATER UTILITY AUTHORITY CROSS CONNECTION PREVENTION AND CONTROL ORDINANCE

PBX Series Quick Fit Connector Bimetallic Steam Traps

CITY OF BAY CITY ORDINANCE NO. 628

Float and Thermostatic Traps Series H, C and X

FAQ and Device/Usage Chart. What Is a Cross-Connection? What Is Backflow Prevention? What Is Backflow?

MAINTENANCE MANUAL INDEX DOUBLE CHECK ASSEMBLIES MODELS 850 & 850U 1/2" - 2"

M A N U A L

BERMAD Fire Protection

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Flushing and Cleaning the A/C System

ARTICLE 1141 Cross Connection Control Program

BLADDER SURGE CONTROL SYSTEM

CHAPTER II. This chapter contains a simplified description of the pipeline safety requirements. The complete text can be found in 49 CFR Part 192.

VAL-MATIC VALVE AND MANUFACTURING CORP. 905 RIVERSIDE DRIVE, ELMHURST, IL TEL. (630) FAX.

WATER VALVE OWNER S MANUAL REV051811

C. starting positive displacement pumps with the discharge valve closed.

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Revised April (May) 2015

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

Flashing and Cavitation

ORDINANCE NO THE CITY COUNCIL OF THE CITY OF NORTH LAS VEGAS, NEVADA, DOES HEREBY ORDAIN AS FOLLOWS:

WARNING WARNING TABLE 1.

NITROUS TRANSFER PUMP INSTRUCTIONS


THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

Operation and Maintenance Manual Reduced Pressure Backflow Prevention Assemblies

2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

MODEL G300 BRAKE BLEEDER

Application Feature Valve Nominal Liquid Capacity R-22 (in tons)*

The Ninth Edition of the Manual of Cross-Connection Control defines a cross-connection as follows:

TECHNICAL INSTRUCTIONS REPAIR KITS Hydroguard Series 420 Thermostatic Valve All Models (1 9)

AWWA Small Systems Pipe Repair Checklist, as published in July 2008 Opflow Question of the Month

Wastewater Capital Projects Management Standard Construction Specification

REGULATORS D& HD Series

BERMAD Fire Protection

2010 Residential Water Heater Replacement Check List

POD Visor Instructions

Before repairing your toilet, you must determine

Element D Services Plumbing

TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES EFFECTIVE: OCTOBER 2007

Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology

77 ILLINOIS ADMINISTRATIVE CODE, PART 890 (NEW) ILLINOIS PLUMBING CODE (02/04) SUBPART I: WATER SUPPLY AND DISTRIBUTION

WESTFIELD WATER RESOURCES DEPARTMENT

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

The Jockey Pump, an Important Part of a Fire Pump System.

MAINTENANCE INSTRUCTIONS FOR THE CLEAN-FLO CONTINUOUS LAMINAR FLOW INVERSION / OXYGENATION SYSTEM

GENERAL VALVE Four-way Diverter Valve

Finding and Fixing Leaks

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Daniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.

FLUSHOMETER - TANK SYSTEM

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Water valves REFRIGERATION AND AIR CONDITIONING. Fitters notes

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Watts Pure Water Systems

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

COUNTERBALANCE VALVES

SECTION ABANDONMENT OF SEWER MAINS

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

CROSS-CONNECTION CONTROL PROGRAM MANUAL

How To Install A Mazzei Injector

Contents. LWN edition:

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

V47 Series Temperature Actuated Modulating Water Valves

Operator s Manual. Pressure Injection Cell Model PC8500. Congratulations! Contents

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

CHAPTER 26 PLUMBING CODE

How To Replace A Reverse Osmosis Water Tank

3620 W 11th Streetб Houston, TX Telephone: sales@kellogg-american.com Website:

TYPE E Main Valve Sizes 3 /8 through 12

Solenoid Valves and Their Importance in Refrigeration Systems. October 2007

SECTION ABANDONMENT OF WATER MAINS. A. Conform to requirements of Section Submittals.

Injection Systems INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL SYSTEMS

Transcription:

W i n t e r, 1 9 9 7 Why Does the Relief Valve Open? Regularly, the Foundation staff receive calls regarding the activation of the relief valve of a reduced pressure principle assembly (RP). Often it is either the owner or maintenance person at a facility which has recently installed a reduced pressure principle assembly. The statement may be something like, we just installed this valve and it doesn t work or, we just installed this valve and it s leaking. Many Foundation Members may receive similar calls. First of all, it is important to define what is occurring, then we can determine if it is a problem and what the solution may be. Many people have never heard of a backflow preventer until they were required to install one. So, the person complaining about the leaking RP may not have any concept of what it is the RP does. They simply see water coming out of the relief valve and think there is a problem. It is not always possible to determine what the problem is over the telephone, but some problems can be eliminated this way. The actual activation of the relief valve should be clarified. Is the relief valve stuck in an open position and releasing large quantities of water? Does the relief valve have a constant steady drip or slight stream discharging from the port? Does the relief valve activate periodically spitting water? Continued on page 3 Tenth Edition of the Manual Although it seems like the Ninth Edition of the Manual of Cross-Connection Control was just published, it has already been three years. It is now time to begin the process all over again for the Tenth Edition. The Manual Review Committee (MRC) will begin meeting early this year. In addition to the regular meetings, the Manual Review Committee will be opening certain meetings for public comment, suggestions, etc. Those wishing to address the Manual Review Committee will need to request time on the agenda. Foundation Members will be notified of the dates of the open meetings. Those wishing to make suggestions, yet not able to attend these meetings are encouraged to send their suggestions to the Manual Review Committee care of the Foundation Office. It is always better to get suggestions in early so that the committee has enough time to address the concerns submitted. The Foundation will maintain a page on the Foundation s web site which will keep everyone abreast of the proposals and discussions taking place in the MRC. This will also provide an opportunity for Members to submit comments to the Manual Review Committee via the World Wide Web. Comments will also be accepted through the mail or phone calls. I n s i d e C r o s s T a l k Flipping the Disc Tenth Edition of the Manual Cross Talk Changes Spitting Relief Valves Foundation Produces New Video

Foundation Membership he Foundation s Membership Program provides many benefits to the Members of the Foundation. These include: twenty percent discounts on Foundation Training courses for any employee of the Member company/ organization, the List of Approved Backflow Prevention Assemblies, printed quarterly, and access to the up-to-the-minute version of the List for those Members with Internet access. Members may also call the Foundation at any time with technical questions they may have. The Foundation s Engineering Staff is available to assist Members with the various aspects of field testing backflow preventers, installing backflow preventers, administering their cross-connection control program. Accurate Backflow, IN Craig Adams Ahlee Backflow Service Amundson Engineering Australian Backflow Prevention Services CH2M - Hill Correct Flow, Inc. Gary Verholtz Kaiser Permanente PTSM City of Norfolk City of Northglenn Town of Parker Steve Herres Construction Triangle & Leahy, Inc. Universal Studios Hollywood University of Colorado University of Idaho White Rock Utilities Limited Mel Zinberg Cross Talk s New Look C ross Talk, as is quite evident, has taken on a new look. With some recent advances in printing technology, it is possible for the Foundation to print Cross Talk in full color at a cost just a bit less than the previous two color version. This gives us the ability to include color photographs and graphics, making Cross Talk more informative and enjoyable to read. Color photographs provide an effective way of communicating information. Some good examples are shown in the article on Flipping the Disc. You will also notice that the old water drop logo is no longer being used. As mentioned in the April issue of Cross Talk, the University of Southern California has undergone a major change of logo and the Foundation, along with all University departments, are using the new University logo. Two Cross Talk is published by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California for Foundation Members. Limited additional copies are available to Members upon request. (213) 740-2032 1997 University of Southern California. All rights reserved.

Why Does the Relief Valve Open? Discharging large quantities of water If it can be determined that the relief valve is discharging large quantities of water, there may be a problem which requires immediate attention. The relief valve could be stuck in the open position due to debris, or the first check of the RP could be stuck in the open position for the same reason. This could also be caused by a ruptured diaphragm in the relief valve. Another possibility is that the second check could be stuck open with a backpressure condition. No matter what is causing the problem, the assembly will need to be tested to determine the condition of the check valves and relief valve. The relief valve discharges a constant stream or drip. If the relief valve is discharging a continuous drip or stream, all of the same conditions as noted above may exist, but not to the same degree. The most common problem is a fouled first check. If the first check is not seating properly, for any reason, this will cause the relief valve to discharge under non-flowing conditions. The amount of water discharging out of the relief valve directly relates to the size of the fouling of the check. A slight drip may indicate a fine piece of sand or debris on the sealing surface of the check valve. A stream of water is an indication of something larger. If there is a constant flow of water through the assembly, this problem wouldn t appear until the flow of water is stopped, such as to test the backflow preventer. When the water flows through the assembly, the pressure drop across the first check valve increases and, therefore, keeps the relief valve from leaking. When, however, the water stops flowing the check valve leaks causing the relief valve to leak, as well. Another possible cause for the relief valve discharging a constant stream or drip is a fouled relief valve. Some debris could be caught on the relief valve disc, not allowing proper seating of the relief valve. In this situation, the discharge out of the relief valve would not be affected by the flow of water through the assembly. There also remains the possibilities that the diaphragm has a small hole in it, or there is a leaking number two check valve with backpressure. Intermittent discharges from the relief valve In many cases the relief valve may be reported as discharging intermittently, or spitting. When this scenario arises, the RP is most likely doing exactly what it is designed to do. The differential pressure relief valve is designed in such a way that it is hydraulically dependent upon the differential across the first check valve. When the difference in pressure across Continued on page 5 If it can be determined that the relief valve is discharging large quantities of water, there may be a problem which requires immediate attention. Three

Four Training Video in Production Using computer animation, and live action the video will be able to, not only demonstrate the field test procedures, but also show the testers what is happening within the assembly... Last year the Foundation sent a survey to the Members in order to determine which services or products would provide the most benefit to the Members. The survey showed that Members were most interested in a video detailing the field test procedures found in the Ninth Edition of the Manual of Cross- Connection Control. Because of the tremendous interest, the Foundation has begun production on a training video which will explain in detail the field test procedures. Using computer animation, and live action the video will be able to, not only demonstrate the field test better understand and learn the field test procedure. The Foundation s Course for the Training of Backflow Prevention Assembly Testers offers detailed one-on-one instructions to help those attending the course retain the information. However, there is a tremendous amount of information for the attendees to comprehend in five days. This video will allow testers, those preparing for or taking a class, and those getting ready for re-certification to prepare. The video is being produced in such procedures, but also show the testers what is happening within the assembly to help them

Five The Video Continued from page 4 away to help the viewer understand exactly what is occurring internally when some external observations are made. For example, in testing the double check valve assembly, the tester may notice the water n the tube receding. In the video, the live scene will then fade to animation to show the water leaking through the number two check valve and the number two shutoff valve. When the tester observes the water level in the tube receding in the field, he or she will (hopefully) remember the images from the video which show the water leaking past the number two check valve and shutoff valve. Make sure to check the Foundation s web site to see a preview of the video, under Training Tools. As the video is being produced the Foundation is aiming for a low price that will allow individuals to easily purchase the video. Members will be informed as soon as the video is available. It is expected to be available later in the first quarter of 1997. Why Does the Relief Valve Open? the first check drops far enough the relief valve opens. This relieves the pressure in the zone between the check valves and keeps the pressure in that zone reduced lower than inlet pressure thus, the name reduced pressure principle assembly. The assemblies are designed so that the relief valve will keep the pressure in the zone between the check valves at least two pounds per square inch (psi) less than the line pressure upstream of the first check valve. (This means the relief valve has an opening point of at least two psid.) This assures that, even with fouled check valves, the pressure between the two check valves will always remain less than inlet pressure. Since water always flows from high pressure to low, backflow will not occur through the RP. Additionally, the first check is designed to hold a differential of at least three psi above the relief valve opening point. So, in the case of a relief valve with an opening point of two psi, the first check, if working properly, will hold a differential of at least five psi (two psi relief valve opening point plus three psi buffer ). The spitting or intermittent discharging occurs when the pressure fluctuates so much that the differential pressure across the first check valve drops to the relief valve opening point. This can occur Continued on page 7 When the relief valve discharges intermittently, the RP is most likely doing exactly what it is designed to do.

Six Flipping the Disc While Repairing Assemblies Discs subject to extreme backpressure conditions may become permanently deformed by the seat embedding into the elastomer disc. Acommon question received by the Foundation Engineering Staff is: When repairing a backflow preventer is it OK to flip the disc? When testers come across problems during the field test of a backflow preventer, they normally try to assess the situation to determine the problem. Often when a tester obtains an inadequate reading on a check valve, the problem is merely debris which was caught on the disc. This is cleaned off, the assembly reassembled and re-tested. Sometimes, the disc may have had some debris embedded into it which caused permanent deformation. In these cases the tester may be tempted to simply flip the disc over so that the smooth side of the disk (assuming it hasn t been flipped already), which had been against the disc retainer, is sealing against the seat. In some cases this may provide temporary solution, however, this is not the proper means of repairing a backflow preventer. When any portion of a backflow preventer is damaged it is necessary to replace the part with the original manufacturer s replacement parts. To flip the disc is essentially the same as using a used part. When repairing a backflow prevention assembly, the goal should be more than just getting the assembly to pass the test for the moment, by any means. The repair should leave the assembly in a properly operating condition so that it will continue to operate properly. Flipping the disc is really not a repair, but a makeshift way of getting the assembly to pass the test for the moment. In some cases the disc retainer has a phonograph finish or raised rings in order to help the disc stay in place. If this type of disc is flipped the back side of the disc may have the markings of the phonograph finish (as shown on the opposite page) in the sealing area and will likely provide a poor seal against the check valve seat. The tester should always be prepared to repair the assembly they are testing. One should have commonly needed spare parts available, such as discs, gaskets, o-rings, etc., or know where original manufacturer s replacement parts are available. If the tester initiates a repair without the proper parts at hand, they could find, when they decide to flip the disc, that it has already been flipped and neither surface is suitable to get a proper seal. Overall, testers should be sure, when a repair or maintenance is Continued on page 7

Why Does the Relief Valve Open? when the line pressure fluctuates more than three psi quickly. If the assembly is located in a pressure region which has regular line fluctuations, the relief valve could intermittently discharge. Additionally, the discharging of the relief valve, in some cases, causes a slight shock wave to flow through the downstream piping system. The wave can travel through a closed system and bounce back to the RP excerpting pressure on the back side of the second check, which, in turn, causes the relief valve to spit. Some field conditions will actually set up a harmonic condition such that the RV continues to spit until the assembly is isolated (i.e., shutoff valve closed). This can be confusing to the person reviewing the situation since the assembly field tests just fine, and when the water is turned back on the RV doesn t discharge. However, once the pressure fluctuation sets off the condition again, the pressure starts bouncing back and forth in the water line and the RV spits. Flipping the Disc Continued from page 6 necessary, to do a professional and complete job. A backflow preventer which If the spitting relief valve is a problem, but the region is not subject to line pressure fluctuations, one needs to investigate other causes of the spitting. Once a backflow preventer is put onto a water system, the system becomes closed and pressure waves created by quick closing valves downstream of the backflow preventer can no longer dissipate into the water distribution system. In some cases, solenoid valves have sent shock waves through a water system to the number two check valve of an RP. The sudden shock against the second check causes the relief valve to discharge which, in turn, may set up another wave traveling back through the system. Once one discovers the cause of the intermittent relief valve discharging, a solution can be implemented. It has been reported, in many cases, that a single resilient seated check valve upstream or downstream (depending upon the source of the fluctuation) of an assembly will reduce the fluctuating pressure enough to stop the discharging of the relief valve. If the pressure fluctuation is caused by a solenoid valve downstream, it must be adjusted to close more slowly or a more slowly closing solenoid valve may be used. Other reported solutions include a pressure reducing valve or an expansion tank to dampen out any line fluctuations. It has been reported, in many cases, that a single resilient seated check valve upstream or downstream (depending upon the source of the fluctuation) of an assembly will reduce the fluctuating pressure enough to stop the discharging of the relief valve. is not properly repaired or maintained may not provide adequate backflow protection when needed. The solution to the problem may be unique to the given piping system and installation. It is important to gather all of the facts and investigate the problem before a solution can be implemented. Seven

Training Courses Tester Cours Las Vegas, NV 3-7 February 1997 Los Angeles, CA 12-16 May 1997 Los Angeles, CA 14-18 July 1997 Incline Village, NV 4-8 August 1997 Charleston, SC 15-19 September 1997 Las Vegas, NV 17-21 November 1997 Specialist Course Incline Village, NV 10-14 March 1997 Upcoming Events Utah Chapter American Backflow Prevention Association (ABPA) Meeting 31 January 1997 CA/NV Section AWWA Tester Refresher Course -Ontario, CA 22 February 1997 Nebraska Chapter ABPA Meeting 6 March 1997 CA/NV AWWA Conference 9-10 April 1997 ABPA National Conference -Ashville, NC 27-30 April 1997 New Mexico Backflow Prevention Society 28 May 1997 Ft. Worth, TX 2-6 June 1997 Los Angeles, CA 21-25 July 1997 Foundation for Cross-Connection Control and Hydraulic Research School of Engineering University of Southern California Kaprielian Hall 200 Los Angeles, California 90089-2531