TECHNICAL INSTRUCTIONS FOR CONCEPT 2 AND CONCEPT 2 MINI CENTRAL HEATING COOKERS



Similar documents
Stove-boiler for solid fuels KW Directions for use and assembling

STOVE-BOILER FOR SOLID FUELS Directions for use and assembling

Meaco 30L and Meaco 40L dehumidifier instruction manual

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Factory owners must ensure the boiler is:

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.

Portable Air Conditioner

Installation Instructions for Alarm Module Kit A043F059

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

INSTRUCTION FOR ASSEMBLY. 150x180 v Traditional sauna cabin

Select Radiators Installation Guide

IH E Sigma Island 90

Reducing Injury and Damage Related to Electric Dryer Fires. Fire Containment Tests for the Second Edition of UL 2158

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

Infrarot-Bewegungsmelder IP44

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Decree of the Ministry of the Environment on fire safety of ventilation systems

3620 W 11th Streetб Houston, TX Telephone: sales@kellogg-american.com Website:

orlando OWNER S MANUAL

Description of functions

VACUUM CLEANER INSTRUCTION MANUAL

Laddomat Charging unit

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

MY HOME IN A HOUSING BLOCK A GUIDE FOR RESIDENTS

Use and Care Manual. Model CPA12KH AIR CONDITIONER

SF15K SF05KSS, SF10KSS

PBX Series Quick Fit Connector Bimetallic Steam Traps

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

SunMaxx Solar Filling Station Operating Instructions

UNDERSTANDING CENTRAL HEATING SYSTEMS

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Baxi Combi 80e & 105e

T H A N K Y OU F O R Y OUR P U R C H A S E O F A N E S S E N T I A V A N I T Y, P L E A S E R E A D T H E S E V A N I T Y C A R E A N D I N S T A L L

1 DESCRIPTION OF THE APPLIANCE

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

AIR-CONDITIONER SPLIT TYPE

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko

Boiler and Burner Cleaning and Servicing Specifications

Air Conditioning System

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

Wine Cooler with Thermo-Electric Cooling & Heating Technology

Mikrobølgeovn. Model:OMF20MNIN0TW1

Dealing with damp and mould growth

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

FLEXIT S4 R S6 R S7 R

Operations Manual Blast Chiller

INFRARED QUARTZ WALL HEATER


PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

SL280UHV SERIES GAS FURNACE WARNING

Important Safeguards

Nest Learning Thermostat Installation Guide. Installation step-by-step

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

Hydraulic control unit series

IMPORTANT SAFETY NOTICE

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

Installation and Service Instructions. Neutralization System Part no Grünbeck part no

Operating Instructions Bedienungsanleitung Mode d emploi

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Microwave Oven. Warning: a) This oven is not for commercial use. b) Don't open the cover of the machine except professional person.

- 2 - IMPORTANT SAFETY REMINDERS

Operating and Installation Instructions

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

Thank You... On behalf of the entire team at Thane Housewares, we appreciate your recent purchase

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

SMD Rework Station TABLE OF CONTENTS

PG_IM_A.indd 1 23/06/ :22

User Manual THR840DUK Digital Thermostat

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

This section gives you some helpful information and tips on running your home and the equipment in it.

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Stove Guard Kit User Manual

San josé OWNER S MANUAL

DRYER VENTING SPECIFICATIONS DRYER SAFETY

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Operating instructions

Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:

OPTIONAL SLENDER REMOTE CONTROL

car + boat Box Contents x2 x _DC16_CAR_BOAT_OPSMAN.indd 1 29/7/08 15:27:01

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Transcription:

TECHNICAL INSTRUCTIONS FOR CONCEPT 2 AND CONCEPT 2 MINI CENTRAL HEATING COOKERS

Dear Customers, We would like to thank you for your trust and to congratulate you since by this purchase you have become a member of voluminous family of satisfied buyers of company ABC PROIZVOD. We anticipate that soon you will be sure that you selected a quality and economic product, being a result of longstanding tradition of our company in the manufacture of central heating boilers and cookers. If you have any doubts, concerns or inquiries, please do not hesitate to contact us, no matter where and from whom you purchased our product, we will provide you with our assistance bymeans of expert advice and technical support. Yours Faithfully Founded in 1990. Prior to use of these central heating cookers, please read this manual carefully, since it provides you with information regarding safe installation, operation and maintenance of these devices. 1.Cooker intended use and specific features... 2 2. Safety... 2 3. Description and technical characteristics... 3 4. Transportation and storage... 5 5. lnstallation... 6 6. Operation-fuel feeding... 9 7. Troubleshooting... 11 8. Cleaning and maintenance... 11 9. Disassembly and disposal... 12 10. Addition... 13 11. Warranty... 14 ABC PRODUCT d. o. o. Serbia, 31 000 Uzice, Milosa Obrenovica 2 + 381 (0) 31 514 502, e-mail: office@abcproizvod.rs www.abcproizvod.rs 1

1. INTEDED USE AND SPECIFIC FEATURES OF CENTRAL HEATING COOKER These cookers are intended for heating of premises via central heating utility as well as food boiling and roasting, by solid fuel feeding (coal or dry wood). Besides that, it looks like a fireplace owing to fire-resistant glass on the firebox door.the cooker may be connected to a utility with either open or close pressure maintenance system, with water temperature up to 90 C and max. working pressure of 2.5 Bars. The cooker design allows easy fuel feeding and ahs cleaning. Reliable operation is enabled, high degree of usability, as well as long life when following recommendations for accurate installation and exploitation, which we prove by a 5-year warranty. All connections on the cooker (inlet-outlet lines, smoke tube, heat exchanger connector, etc) are standard, therefore not requiring any special adaptation during the connection. IMPORTANT WARNING: During the operation, the cooker door has to be closed, otherwise an uncontrolled temperature rise may occur exceeding an allowed limit, which may cause damages on the cooker and utilities. Besides that, an unjustified increased fuel consumption may happen, as well. 2. SAFETY 2.1. SAFETY AND RELIABILITY IN COOKER OPERATION These central heating cookers are designed and fabricated to provide the highest operation safety provided that the users comply with this MANUAL in all aspects. No responsibility is taken for injuries to humans, animals, or property damages as a consequence of non-compliance with this manual. Any other use of the cooker is considered incorrect and thus either hazardous, too, such as: Ÿ Change of the cooker's intended use by solid fuel feeding but with no connection of hot water line; Ÿ Drying of coal, wood, fire starters, other objects and animals in the oven; Ÿ Drying above the hob of laundry, fuel and other flammable objects or objects which may fall onto the hob. 2

2.2 IMPORTANT SAFETY WARNINGS 1. The cooker has to be mounted and connected to central heating supply by authorized/qualified installer-technician in conformity with this manufacturer's manual. He provides the user/operator of the cooker with basic explanations out of this manual's contents. 2. This cooker may only be operated by a trained and skilled person. Children must not operate this cooker. 3. Stay away from hot surfaces and do not touch them. Keep children and the disabled people away from them. 4. Do not put anything that may cause an accident or damage (empty glass or enamel dishes, inflammable objects, deformed and unstable dishes which may fall over, etc) onto the hob. Ensure that handles of the dishes do not project from the hob, so that you may not move them accidentally. 5. Do not use or keep inflammable objects and volatile liquids in the vicinity of the cooker. 6. When using small household appliances in the vicinity of the cooker, ensure that their power cable do not touch the hot hob of the cooker. 7. Never put any objects or inflammable matters in the drawer blow the oven (except wood for burning). 3. DESCRIPTION AND TECHNICAL CHARACTERISTICS The cooker to which this MANUAL refers is designed for solid fuel (coal and dry wood) feeding. Besides that, it looks like a fireplace due to fire-resistant glass on the firebox door. It is made of certified boilerplate with proved chemical composition and mechanical features at higher temperatures. It is welded by means of most up-to-date welding procedures. Testing of the cooker is performed with water under 3-Bar pressure. The cooker has water-cooled grid, made of seamless tubes as well as ash ejector allowing efficient ash ejection from firebox into the ashtray. This enables a better fresh air supply to combustion area. These types of cooker enable lifting the firebox together with the grid. Placement of this grid reduces heating capacity, therefore the cooker may be used to heat confined area, either. By firebox lifting, the effect of heating on the hob is improved without any losses of the desired temperature within the oven. By the point of chimney connection, the cooker may be either left- or right-sided (lateral connection) or with hob connection. Concept 2 mini cookers are universal, left- or right-sided with the connection to the hob allowed. Before connecting the cooker to the chimney, one needs to remove sheet metal from lateral panel, detach protective sheet metal from the smoke tube (either on the left or on the right side, depending on the side you selected for connection to chimney), F.2, pos. no.18. 3

Standard connector on all our cookers is 145 mm. In case that this connector is not suitable for you, our factory in its product range may offer reductors converting the existing status into the following dimensions: 120, 130 or 150. Picture number 1: STOVE FOR CENTRAL HEATING Concept 2 1. Firebox door 2. Thermometer for water in the cooker 3. Oven door 4. Oven thermometer 5. Flap handle 6. Ashtray door 7. Ash ejector 8. Drought controller 9. Smoke tube 10. Opening for panel removal 10. Opening for cleaning below the oven 11. Wood drawer 12-12'. Connector R1/2" for heat exchanger (thermal protection) 13. Connector R1/2" for thermal valve 14. Supply line R1" 15. Connector R1/2" for safety valve 16. Returning line R1 " 17. Load and unload connector R1/2" Technical details for all cooker types TECHNICAL DETAILS Power transferred to water(kw)* Required draught (Pa) Mass (total weight) (kg) Water volume (I) Max working temperature ( C) Max working pressure (Bars) Smoke tube diameter (mm) Width L (mm) Height H (mm) Depth D (mm) Concept 2 Concept 2 Mini Coal Wood Coal Wood * NOTE: Power emitted by the cooker by radiation in the room was cot considered. 4

Picture number 2: CENTRAL HEATING COOKER - Concept 2 mini 1. Firebox door 2. Thermometer for water within the cooker б. Ashtray door 7. Ash ejector 8. Drought controller 12-12: Connector R1/2" for heat exchanger (thermal protection) 13. Connector R1/2"for thermal valve 14. Supply line R1 " 15. Connector R1/2" for safety valve 16. Returning line R1 " 17. Load and unload connector R1/2" 18. Protective smoke tube sheet metal 4. TRANSPORTATION AND STORAGE The cooker is protected with packaging which is not precipitation-resistant. It should be kept under covered area. Transportation to the user's destination is performed as agreed. When you remove the unit from the cooker, check for any accidental damages during transportation and manipulation. If you have any doubts regarding its functionality, contact your retails or factory ABC PROIZVOD directly. Keep packaging components out of reach of the children, since they may be hazardous. 5

5. PLACEMENT / INSTALLATION Design, placement and central heating installation is mandatory to be done by a qualified person. In case of poorly designed system and possible defects in installation by mentioned person, which in turn may cause incorrect cooker functionality, solely the installer of heating system, not the manufacturer, representative or retailer of the cooker, bears both complete material responsibility and unexpected expenses. The cooker may be placed in the kitchen or some other suitable area, under the condition that a non-flammable base, sufficient manipulation area, room ventilation and suitable chimney are provided. When installing the cooker, take care about the following: а) Furniture and objects next to the cooker must not be made of flammable materials, otherwise their distance from the cooker has to be min. 20 cm. b) Under no circumstances can the shelves or similar wooden furniture be placed under the cooker hob c) The wall which is in contact with the back of the cooker has to be made of a heat-resistant material d) Do not place curtains directly behind the cooker, when placing them laterally, they should be placed as far as possible e) Flammable materials, f.e. door frames, wallpapers have to be at least 20 mm away from smoke tubes. This distance may be reduced if appropriate thermal insulation is installed around smoke tubes. f) Place the cooker in horizontal position or lift the back of it slightly (2-4 mm). 5.2. CONNECTION TO CHIMNEY As an essential component of central heating system, the chimney has to have an appropriate cross section, and to be duly installed, correctly placed above the roof and insulated (F.4). Determination of the size and check of the existing chimney is performed by the designer of central heating utility based on the cooker capacity, fuel type of required drought for selected cooker. The cooker reaches the declared power only in case of appropriate size of the chimney. All smoke tube joints from the cooker to the chimney have to be properly sealed. F.3. The chimney needs to be duly placed above the roof as per the instructions presented in F.4. Avoid the placement of chimney caps, especially if with lateral blinds. In case of possible placement of a chimney cap, act as recommended in F. 4.. 6

Picture 3 Connection to chimney Correct cooker connection to chimney Incorrect cooker connection to chimney Sealed Pipe Cleaning hole sealed Cleaning hole Sealed Sealed Cleaning hole sealed Cleaning hole Sealed Pipe Cleaning hole sealed Cleaning hole Picture 4. Chimney installation above the roof and chimney cap placement Putting a chimney above roof Chimney hat 7

5.3.INSTALLATION Central heating cooker may be connected to open system (F. 5) and to closed system (F. б) of central heating utility, since the cooker has built-in thermal safety feature a heat exchanger. Thermal valve is not delivered with the cooker. Preferably connect the cooker to open central heating system, and connection of a thermal valve with a probe to the cooker is however mandatory as well as connection of the heat exchanger to water supply network. Warranty shall be void without the thermal valve connection. All cooker joints need to be properly sealed, which should be visually checked before commissioning. A final step in the mounting procedure is to fill the cooker and all the utilities with water up to the required pressure. DO NOT USE THE COOKER WITHOUT WATER. Picture 5 Scheme of cooker connection to open central heating system 1. Cooker Concept 2 2. Smoke tube 3. Open expansion vessel 4. Discharge pipe 5. Manometer 6. Radiator valve 7. Radiator 8. Air valve 9. Circulation pump 10. Safety valve 11. Thermal valve 12. Water supply connection line 12'. Hot water drain 13. Thermal valve probe 14. Supply line 15. Safety valve connector 16. Returning line 17. Load and unload connector 1/2" 8

Picture number 6 Scheme of the cooker connection to closed central heating 1. Cooker Concept 2 2. Smoke tube 3. Valve 4. Closed expansion vessel 5. Manometer 6. Radiator valve 7. Radiator 8. Air valve 9. Circulation pump 10. Safety valve 11. Thermal valve 12. Water supply connection line 12'. Hot water drain 13. Thermal valve probe 14. Distribution line 15. Safety valve connector 16. Returning line 17. Load and unload connector 1/2" 6. OPERATION FUEL FEEDING Solid fuel has to be physically separated from the cooker by means of spatial and physical barrier. Ashtray needs to be made of non-flammable ingredients and it has to be placed away from fuel storage area. INITIAL FUEL FEEDING The following conditions need to be met at the initial fuel feeding: chimney has to be clean and duly connected with the cooker, the cooker and heating utility need to be equipped with all safety devices, at the initial fuel feeding, pull the flap handle, F.1, pos. 5 (Cooker Concept 2), completely, for more convenient passage of additional cold smoke gases, and once the desired temperature is reached, return the handle into the suitable position, depending on operating mode, fill the system with water and remove the air in cooker operating mode, firebox door and ashtray door need to be closed, set the automatic drought controller button to the desired value, max. cooker working temperature is 90 С. 9

IIMPORTANT NOTE: First fuel feeding may cause condensation water drops and humidity in the ashtray. In this case, increase the cooker temperature gradually and this phenomenon will disappear. 6.2. OPERATION The cooker is fed with fuel as all the other continuously burning solid fuel boilers. The fire is started with the ashtray door open. Having opened the firebox door, put the paper and small prices of wood on the grid and start the fire. Put the heating material gradually into the firebox until the fire intensifies. Only then fill the firebox, close the ashtray door and set the drought controller to the desired temperature. 6.3. USE OF GRID The cooker has water-cooled grid, made of seamless tubes as well as ash ejector, F.1 and F.2, pos. 7, allowing efficient ash ejection from firebox into the ashtray. This enables a better fresh air supply to combustion area. The cooker also has a feature that the firebox may be lifted with the grid, which is placed on suitable holders. The grid is an accessory, and if desired, the customer may either purchase it directly from the manufacturer or order it through a distributor. This grid is intended for use in a transitional season, when external temperature is not too low. Placing this grid, the heating effect on the hob is enhanced, and thus food is boiled and roasted faster, and the cooker may also be used for heating confined premises. 6.4. TEMPERATURE CONTROL On the cooker panel, F.1 and F.2, pos. 8, a drought controller is installed, which function is to set the desired temperature, and in consists of a numerical wheel with 0-8 scale, then of controller flap and capillaries. A thermometer is installed on the cooker, F.1 and F.2 pos. 2, showing the water temperature in the cooker. By means of capillaries, the draught controller (as well as the thermometer) is connected with the probe from which it collects the details about water temperature value in the cooker. The cooker temperature is the lowest when the drought controller is set to no.1, and it is the highest when the drought controller is set to no 8. When the cooker temperature starts to fall, the controller flap is open automatically by 3-5 mm, allowing the flow of secondary drought (air) and better combustion up to the desired temperature. the drought controller settings depend on the desired area temperature. IMPORTANT NOTE: For correct functionality of the drought controller, connect the cooker to the chimney with stipulated dimensions. 10

Clean the space between controller's flap and airflow hole occasionally and remove ash and other burning products' debris. Avoid low water temperatures in the cooker of 50-60 С, since condensation may occur. If you observe water accumulation in either cooker or in the ashtray, simply increase cooker's operating temperature. 6.5 FOOD BOLING, ROASTING AND FRYING During the season of heating, the cooker is used for food heating, boiling, roasting and frying. For faster cooking, roasting and frying, use dry wood as a fuel. For reaching the oven temperature of 250 С required for roasting, dry wood has to be used as a fuel and drought controller (F.1, pos.8) should be set to maximum (no. 8 in the scale). If required, in order to reach desired temperature in a faster and more efficient way, you may open the ashtray door. IMPORTANT: Do not leave the product with the door open unattended, since an uncontrolled temperature rise exceeding an allowed limit may occur. 7. TROUBLESHOOTING Technical disturbances may occur for the following reasons: a) possible factory faults in that case, refer to the manufacturer, company "ABC PROIZVOD", b) fitting, installation and connection faults in that case, refer to the installer, с) as a consequence of incorrect operation, user's failure to comply with a correct mode, heating and maintenance of the cooker in that case, study this manual and take correct steps. If the problem persists, the user should refer to factory "ABC PROIZVOD" for a piece of advice/intervention. 8. CLEANING AND MAINTENANCE To extend the life of your cooker and for its correct functionality, accurate cooker maintenance is required, both during heating season and after. Daily cleaning of ash area and airflow hole below the flap is required. Periodically remove soot from the cooker, at least once monthly, since deposits of soot and pitch in the interior of the firebox of the cooker increase fuel consumption and decrease usability level. The manufacturer recommends the usage of chemical agent ASTRATHERM, which facilitates mechanical removal of deposits of combustion products. Do not use wire brush or wire sponge for cleaning exterior of the cooker, oven and rings since it may damage protective layer, but use a cloth damped with a mild cleaning agent. Clean the oven after each use. 11

Picture number 7 Panel disassembly for cleaning soot below the oven Plating The place where to put a screwdriver Carrier Detail A Screwdriver for removal of plating The opening, pos. 10', F. 7 is designed for cleaning the soot below the oven. The panel is fastened to a clip and is easily removed by a lever principle (f.e. with a screwdriver). On a suitable place (F.7, pos. 10), on the bottom of the panel, on the left, there is an opening. Put the screwdriver is into the opening and place it under the panel by 120 mm, press it down (lever principle) and the panel will be detached from the clip. Remove the panel gently from the small column on the right. Remove protective sheet metal and gasket from the opening intended for cleaning the soot below the oven. When cleaning is complete, replace the gasket, protective sheet metal and panel. The cooker cooling by means of watering the firebox is forbidden. Once the heating season is over, clean the cooker thoroughly and completely. Drain the water only if some utility repairs are required. Upon the completion of the heating season, the manufacturer recommends a linen bag with 1-2 kg of grinded quicklime to be suspended within fuel feeding area. 9. DISASSEMBLY AND DISPOSAL At the end of the product's life, remove power supply, water supply and heating connections, drain water and handle the product to an authorized waste collection/recycling point. In compliance with the European Directives, the symbol of "crossed recycle bin" (see the Figure on the right) warns you that you are committed to treat unusable products with a special attention. 12

10. ADDITION ACCORDANCE WITH EU DIRETIONS AND STANDARDS THESE STOVES ARE MADE BY DIRECTIONS OF EUROPEAN COMMUNITY: 97/ 23/ EC Equipment under pressure 92/ 42/ EEC - Heaters for hot water 93/ 68/ EEC - Heaters for hot water ACCORDANCE WITH INTERNATIONAL STANDARDS The company ABC PROIZVOD in 2007 introduced a quality management system JUS ISO 9001/2008, which is maintained and improved. Since 2013, two additional standards were introduced. SRPS OHSAS 18001/2008 and SRPS ISO 14001/2005, so the company possesses an INTEGRATED QUALITY MANAGEMENT SYSTEM which is certified by an accredited body. 13

WARRANTY Company ABC PRODUCT is giving guarantee for its products as per guarantee given when the products get sold. Dear customers, in case you are not satisfied with our product, please check the following before you decide to get in touch with us: 1. Did you do everything as suggested by INSTRUCTIONS when installing it: choice of power of stove in correlation to the scored and projected capacity of the heating; height, ǿ, insulation of chimney, especially if the chimney is built up next to the building; regular use of other parts of heating installations, which can have effects on use of the stove; coverage in case of lost of electricity supply; coverage of stove by implementation of term vents with sound and connection of heat exchanger to the water supply. 2. Are you using suggested heating regime and regime of maintaining stove temperature in aspects of: -proper choice of heating gradual heating - compulsory closer of ashtray; -ash shaker use. 3. Are you doing all to keep the product without ash and tar from the insides of stove and chimney? 4. Did you do anything on your own initiative to change the product? All above mentioned can have an effect on your guarantee's rights, durability of the stove and installation and exposure to the unnecessary cost in case of unnecessary visit to do the service when you call us. 14