Conformity assessment procedures of breast implants



Similar documents
GUIDELINES ON MEDICAL DEVICES EVALUATION OF CLINICAL DATA : A GUIDE FOR MANUFACTURERS AND NOTIFIED BODIES

BSI Road Show: September 8 th to 15 th, 2014

Medical Device Software Do You Understand How Software is Regulated?

Med-Info. Council Directive 93/42/EEC on Medical Devices. TÜV SÜD Product Service GmbH

Guidance for manufacturers and Notified Bodies on reporting of Design Changes and Changes of the Quality System

GUIDANCE NOTE FOR MANUFACTURERS OF CUSTOM-MADE MEDICAL DEVICES

LIST OF INTERNATIONAL STANDARDS FOR MEDICAL DEVICES

GUIDANCE NOTES FOR MANUFACTURERS OF CLASS I MEDICAL DEVICES

Guidelines for conformity assessment of In Vitro Fertilisation (IVF) and Assisted Reproduction Technologies (ART) products

GUIDELINES ON MEDICAL DEVICES

How To Know If A Mobile App Is A Medical Device

THE MENTOR COMMITMENT

GUIDELINES ON MEDICAL DEVICES. IVD GUIDANCES : Borderline issues A GUIDE FOR MANUFACTURERS AND NOTIFIED BODIES

Medical Devices. Notified Bodies and the CE certification Process for Medical Devices. European Surgical Robotics Demonstration Day

WHITEPAPER: SOFTWARE APPS AS MEDICAL DEVICES THE REGULATORY LANDSCAPE

Frequently Asked Questions. Unannounced audits for manufacturers of CE-marked medical devices. 720 DM a Rev /10/02

Guide for Custom-Made Dental Device Manufacturers on Compliance with European Communities (Medical Devices) Regulations, 1994

Medical Devices: CE Marking Step-by Step

NBOG s Best Practice Guide

Manual for ITC's clients, Conformity assessment of ACTIVE IMPLANTABLE MEDICAL DEVICES pursuant to Council Directive 90/385/EEC

Medical Device Directive 2007/47/EC What is New? Are we moving towards Drug Rules?

Update: Proposed Medical Device Regulation (MDR) & IVD Regulation (IVDR)

FINAL DOCUMENT. Global Harmonization Task Force. Title: Label and Instructions for Use for Medical Devices

ALL Medical Devices regardless of Classification

Vigilance Reporting. Vicky Medley - Head of QMS, Medical Devices. September Copyright 2015 BSI. All rights reserved.

Guidance Notes for Applicants of the Certificate for Clinical Trial on Medical Device

Information supplied by the manufacturer with medical devices

Basic Information about the European Directive 93/42/EEC on Medical Devices

TECHNICAL BOOKLET. Recreating harmonious bodies for a new vision of rebirth.

NOTICE. Re: GD210: ISO 13485:2003 Quality Management System Audits Performed by Health Canada Recognized Registrars

CE-Marked Product List (MDD)

COPYRIGHT ASPS. Breast Augmentation. The Symbol of Excellence in Plastic Surgery

RECALLS in EUROPE. Past, present, near & further future. Gert Bos BSI Medcon May 2012

Michael A. Boss, M.D. FMH Plastic, Reconstructive und Aesthetic Surgery

Sientra Silicone Gel Breast Implants Quick Facts About Breast Augmentation And Reconstruction

EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL

Affected Product: Polyethylene Implants from Gender Solutions Natural-Knee Flex, Natural-Knee, Natural-Knee II, MOST Options, and Apollo Systems

Product manufacturing from zirconium oxide

MEDICAL DEVICES: Guidance document

ÖNORM EN The European Standard EN has the status of an Austrian Standard. Edition: Standards group B

THE POST-MARKET PRIORITY Understanding and Meeting Demand for Effective Post-Market Clinical Follow-Up

Reporting Changes to your Notified Body

CE Marking: Your Key to Entering the European Market

IAF Mandatory Document for the Application of ISO/IEC in Medical Device Quality Management Systems (ISO 13485)

How to Use the Design Process to Manage Risk: Elements of Design Controls and Why It Matters

Quality Risk Management - The Medical Device Experience. Niamh Nolan Principal Design Assurance Engineer Boston Scientific

Medical Device Training Program 2015

IMPLANT MENTOR EFFECTIVE JANUARY 2012 BREAST IMPLANTS NOT FOR DISTRIBUTION IN USA APPROVED FOR EMEA REGION. Mentor Worldwide LLC Rev C

Office for Nuclear Regulation

CHECKLIST ISO/IEC 17021:2011 Conformity Assessment Requirements for Bodies Providing Audit and Certification of Management Systems

Working Party on Control of Medicines and Inspections. Final Version of Annex 16 to the EU Guide to Good Manufacturing Practice

In the Pursuit of Safety: Breast Implants Made in Germany

PLM: Privat Label Manufacturer (Customer of the OEM-PLM relation) OEM: Original Equipment Manufacturer (Supplier of the OEM-PLM relation)

PERTHESE Breast Implants. Cohesive silicone gel-filled breast implants

Inspection campaign summary report

GUIDELINES ON MEDICAL DEVICES

RADIOPHARMACEUTICALS BASED ON MONOCLONAL ANTIBODIES

Med-Info. Introduction to Korean Medical Device regulations. TÜV SÜD Product Service GmbH

Navigating the New EU Rules for Medical Device Software

Clinical evaluation Latest development in expectations EU and USA

ISO 13485: INTERNAL AUDIT CHECKLIST

2002 No. 618 CONSUMER PROTECTION. The Medical Devices Regulations 2002

Quick Facts about Breast Augmentation with IDEAL IMPLANT Saline-filled Breast Implants

GUIDELINES ON A MEDICAL DEVICES VIGILANCE SYSTEM

Risk Management and the Impact of EN ISO 14971:2012 Annex Z

This is Document Schedule 5 Part 1 referred to in this Contract SCOTTISH MINISTERS REQUIREMENTS SCHEDULE 5 PART 1 QUALITY MANAGEMENT SYSTEM

MEDICAL DEVICES : Guidance document

2015. All rights reserved.

Narcotics Ordinance on Charges (Betäubungsmittel-Kostenverordnung) Introductory clause

Changes to Medical Device Regulations

SQ 901 Version D. Railway Application Quality Specification REQUIREMENTS FOR THE QUALITY MANAGEMENT SYSTEM AND QUALITY PLAN

General Rules for the Certification of Management Systems Code: RG

EUROTUBO DELTALAB 6. SWABS

NOTICE TO MANUFACTURERS OF RADIOTHERAPY MEDICAL DEVICES

REGULATORY IMPACT ANALYSIS (RIA) SAFETY, HEALTH AND WELFARE AT WORK. (Electromagnetic Fields) REGULATIONS (S.I. No. of 2016) 5 th January 2015

BSI Unannounced Audits

TABLE OF CONTENTS. Surgical Technique 2. Indications 4. Product Information Patient Positioning and Approach 2

GUIDELINES ON A MEDICAL DEVICES VIGILANCE SYSTEM

XXXXX File No Petitioner v. Issued and entered this 28 th day of June 2010 by Ken Ross Commissioner ORDER I PROCEDURAL BACKGROUND

Certification Bodies for Quality Management Systems

European Regulatory Newsletter July - September 2013

Brief Summary on the Philippine B bilateral Air Services Agreement

FACTS about. MENTOR MemoryGel. Silicone Gel Filled Breast Implants

GUIDELINES ON MEDICAL DEVICES

Konformitätsbewertung 3.9 B 17. Guidance for Notified Bodies auditing suppliers to medical device manufacturers

Having regard to the Treaty establishing the European Economic Community, and in particular Article 100 thereof;

Want to know more about the Notified Body?

Uninterruptible Power Supply Product Regulations and Standardization in the European Union. By Matteo Tricarico Patents and Regulatory Engineer

Quality Manual TABLE OF CONTENTS APPROVAL SIGNATURE PAGE AMENDMENT RECORD SCOPE EXCLUSIONS 2.1 3

10. These general principles are explored in further detail in relation to medical implants in the following section.

CODING. Neighborhood Health Plan 1 Provider Payment Guidelines

GUIDELINES ON MEDICAL DEVICES

Correspondence between ISO 13485:2003 and the US Quality System Regulation

Corrective Actions ISO Coca Cola Company and Michigan State University, original at CC BY SA

RFID Survives Sterilization to Deliver Medical Device Tracking Solution

Conformity assessment certification

How To Inspect A Blood Bank

New OIML Document Surveillance of utility meters in service based on sampling inspections

August 21, TCM Associates Ltd Mr. Iain Alligan Technical Director 3 Hillgrove Business Park Nazeing Road Essex EN9 2HB United Kingdom

Transcription:

Chapter: 2.5.5 Conformity assessment procedures; Conformity assessment for particular product groups Text:... Key words: Conformity assessment, breast implants The NB-MED (stage 3, Rev.-Nr. 4, Rev. date 27.06.97.98) was superseded by the MedDev-document MedDev 2.5/6 Guidelines for conformity assessment of breast implants according to MDD (July 98, distributed to NB-MED as NBM/125/98) (reasons see also attached Rationale and history sheet) A rationale and history sheet is available; please contact Technical Secretariat. Reference to Article/ Reference to standards: Directives: Annex: AIMD MDD Annex: II, III see chapter 3, references IVDD Stage proposed by Rev.-Nr. Rev. date accepted amended withdrawn deleted 5 03.02.2000 03.02.2000 1/6 VdTÜV Technical Secretariat NB-MED PO Box 10 38 34 D-45038 Essen G. Hinrich Schaub (- 178) Jörg Höppner (- 138) Kurfürstenstraße 56 D-45138 Essen Phone: ++49/201/8987-0 Fax: ++49/201/8987-120 email: vdtuev.essen@t-online.de

Foreword Due to continuous public interest and regulatory actions taken by some countries on manufacturing and distribution of breast implants the NB-MED Meeting on September 11 and 12, 1995 decided to establish a project group. The task of this group consisting of representatives of Notified Bodies, Competent Authorities, EQUAM, manufacturers and consumer groups was to develop recommendations for an adequate approach to be taken by Notified Bodies in conformity assessment procedures of those products. 1 Scope Breast implants are usually Class IIb products, in some cases they are class III according to MDD, Annex IX, Rules 8, 13 or 17. This document is intended to give guidance to Notified Bodies for the conformity assessment of breast implants according to Annexes II and III of the MDD. 2 s The product related hazards of breast implants can be divided into the following categories: - hazards associated with the design and manufacture of the device - hazards associated with the surgery and inherent hazards associated with the clinical use of breast implants. In the following the hazards and the respective requirements to be considered are listed. The manufacturer must evaluate the risk associated with each hazard listed below. The second column of the table gives the respective requirements to be considered. The information is not exhaustive and can be completed by further considerations. This information can be considered as a basis for the risk analysis which may be performed in accordance with pren 1441. 2.1 Hazards associated with the design and manufacture of the device Hazard Requirement 2/2

Mechanical failure Results of mechanical testing according to pren 12180, 7.1 and adequate quality control at different steps of manufacture must be available. The aspects of aging and biodegradation have to be addressed in the technical documentation. Capsular contraction Lack of sterility of the product To be addressed in the clinical evaluation. The product must be supplied sterile. The EN 550 series of standards can be used where appropriate. The sterilization process must have been validated adequately and documented in the technical file. The validation must demonstrate the fulfilment of EN 556. Lack of biocompatibility Biological evaluation according to pren 14630 and pren 12180,6 and 7.1.7 in combination with EN 30993-1, ISO/DIS 14538, and pren 1441, Annex B covers the risks to demonstrate conformity. Physical/chemical incompatibilities Osmotic changes Interference with medical diagnosis and treatment Lack of traceability Data about compatibility between shell and filler must be available. Data about the osmotic situation must be available, if applicable. Information about possible interference with diagnosis and treatment must be addressed in the labelling. pren 12180, 11.6 has to be applied. 3/2

Limited lifetime Unknown shelf-life Expected lifetime of implants (stability after implantation) must be demonstrated according to available information and adequately documented. Data shall be available to justify expected lifetime of all components (durability and age related changes). The manufacturer has to provide adequate information in the instructions for use in relation to limitation of lifetime. The expiry date based on stability data has to be given and is addressed in pren 1041 and pren 980 The Notified Body shall during the conformity assessment procedure review the clinical evaluation in the technical file in compliance with MDD, Annex I, Section 14 in conjunction with Annex X. The manufacturer must institute and keep up to date a systematic procedure to gain and review experience from devices in the marketing phase including reviews of risk analysis and plans for any necessary corrective action. During each surveillance audit the Notified Body shall review the experience gained by the manufacturer in the marketing phase and the consequences taken. 2.2 Hazards associated with the surgery and inherent hazards associated with the clinical use of breast implants Information about the risks associated with the surgery shall be provided in the labelling. These shall include: 1. clear indications for the use of the implant, 2. clear contraindications, 3. known adverse reactions, 4. a statement that breast implants are single use devices and must not be resterilized and/or reused. Risks associated with lack of expertise of the surgeon and the need for follow-up of the patient shall be addressed. 4/2

There are certain risks particularly inherent in the use of breast implants or postulated from their use. These are addressed specifically during consultation between physician and patient and subject to informed consent. Note 1: Note 2: The instructions for use must also include details allowing the medical staff to brief the patient on any contra-indications and any precautions to be taken (MDD, Annex I, Essential Requirements, 13.6). The manufacturer of breast implants should refer in the instructions for use to the Patient Information and Consent Form on Silicone Breast Implants developed and issued by EQUAM (European Committee on Quality Assurance and Medical Devices in Plastic Surgery) or equivalent information. 3 References EN 550: 1994 EN 552: 1994 EN 554: 1994 EN 556: 1994 EN 30993-1: 1993 pren 980: 1995 pren 1041: 1994 pren 1441: 1994 Sterilization of medical devices - Validation and routine control of ethylene oxide sterilization Sterilization of medical devices - Validation and routine control of sterilization by irradiation Sterilization of medical devices - Validation and routine control of sterilization by moist heat Sterilization of medical devices - Requirements for devices to be labelled 'Sterile' Biological evaluation of medical devices - Part 1: Guidance on selection of tests Graphical symbols for use in the labelling of medical device Terminology. symbols and information provided with medical devices; information supplied by the manufacturer with medical devices Medical devices - Risk analysis pren 12180 Non active surgical implants - Body contouring implants - Specific requirements for mammary implants 5/2

pren 14630 Non-active surgical implants - General requirements ISO/DIS 14538: 1996 Methods for the establishment of allowable limits for residues in medical devices using health based risk assessment Note: This document refers to applicable standards. Other applicable solutions may be used by the manufacturer to demonstrate compliance with the essential requirements. 6/2

Rationale and history sheet to Rev. 4: Notified Body Meeting, Brussels, June. 24 & 25. 1997: The draft document for conformity assessment procedures of -breast implants was revised on 25.09.96 and subject to discussion by the Medical Device Experts Group at their meeting on 25 February 1997. This document was prepared by NB-MED Task Force Conformity assessment for breast implants (Convenor: Dr. Müller-Lierheim/MDC; Members: Mr Binard/G- MED, Mr Chitarrini/,Laboratoires Sebbin, Mr Dawids/DMDC, Dr. de Jong/MENTOR Medical Systems, Dr. Eisenmann-Klein/Caritas Krankenhaus St. Josef, Mr Gügel/TÜV Product Service, Mr Hüser/Polytech Silimed Europe, Ms Jeanty/LPI - Laboratoire Perouse Implant, Dr. Laufer/Collagen/LipoMatrix, Ms Meyer/SSF, Mr Rentschler/MDC, Mr Thalen/IAPM, Mr Tinkler/MDA Medical Device Agency, Dr. Tschöpe/BfArM - Bundesinstitut für Arzneimittel und Medizinprodukte, Ms White/McGhan, Mr Wild/SHG-D). With some minor changes requested by the Medical Device Experts Group the document was tabled on the Notified Body Meeting on 24./25.06.97. The document was approved by the NB-MED plenary. Meeting of NBR Group, Brussels, June 26 & 27 1997: The NBRG has brought the document into the format of a NB-MED recommendation and issued it among their stage 3 -recommendations. It was decided to give a proposal to the Medical Device Expert Group concerning a concluding discussion of the use of shall / should and the consideration of Liquid Implants. Confirmed at stage 3. New revision no: 4 Meeting of NBR Group, Essen, September 29 & 30 1997: It was decided to fit the document in the new recommendations nomenclature system (chapter 2.5.5 Conformity assessment procedures; Conformity assessment for particular product groups). Therefore the recommendation gets the number NB-MED/2.5.1/R1. Rev. 5: Notified Body Meeting, Brussels, November 2 & 3. 1999: It was mentioned that the stage 3 on breats implants needs some further development; since the adoption in 1997 the Commission has done a lot of work to this subject which is not be reflected by the present. The French Competent Authority is waiting for a strongest Commission s document to withdraw banning of such devices. Rev.-Nr. Rev. date accepted amended withdrawn 03.02.2000 1/2 VdTÜV Technical Secretariat NB-MED PO Box 10 38 34 D-45038 Essen G. Hinrich Schaub (- 178) Jörg Höppner (- 138) Kurfürstenstraße 56 D-45138 Essen Phone: ++49/201/8987-0 Fax: ++49/201/8987-120 email: vdtuev.essen@t-online.de

Rationale and history sheet to Meeting of NBR Group, Brussels, November 3, 1999: It was propsed by Mr. V. and subsequently agreed at the NBRG meeting that NB-MED No. 2.5.5/Rec1 on Breast Implants should be withdrawn from the list of NB-MED s because a revised MedDev 2.5/6 is in preparation, the context of which more accurately identifies the requirements relating to this product. The revised MedDev will be included when agreed and published; in the meanwhile the former and existing MedDev 2.5/6 (issued as final draft 07/98) is still valid and supersedes this. The Technical Secretariat was asked to rework the rationale & history of this and the list of NB-MED s and to withdraw this. Meeting of NBR Group, Cologne, February 3, 2000: NBRG agreed with tabled document and the described procedure to handle this. Confirmed at stage delete. New revision no: 5 2/2