Leak Detection System



Similar documents
Instructions. Complete RPS 2900 Pump Kit for RoadLazer RoadPak Line Striping System 3A1304A ENG. Pressure Relief Procedure.

Battery Charger. Instruction Manual G

ADP Autoline 3A0986A ENG

- For pumping exact amounts of lubrication fluids from a reservoir to specific lubrication points -

Feed Pump and Agitator Kits

Advantium 2 Plus Alarm

Extrusion Flo-Valve INSTRUCTIONS-PARTS LIST psi (210 bar) Maximum Working Pressure. Model , Series K. Rev.

Test Fixture, High Voltage Probe, and kv Meter

Pump for Drywall Feed Pump System

55-Gallon Dispenser Package

Fluid Regulator. Instructions Parts List L LOW PRESSURE

Warranty Terms. QLogic-provided cables, optics and other accessories are warranted for ninety (90) days from date of purchase.

, User s Manual

Instructions Parts List

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

Owner s Manual & Safety Instructions

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

In-Line Filters and Coalescers with Automatic Drains

Ultra-Lite In-Line Flow Gun

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

Installation and Operation Guide for PD5100 Automatic Transfer Switch

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

ProMix 2KS/3KS Web Interfaces

AirPro Gravity Feed Airspray Gun

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

1 / 4 IN. FFL x 4 FT. 9 IN. 1 / 2 IN. ACME x 4 FT. 9 IN. Gauge Accuracy +/-2% Set includes Quick Disconnect Valves

User Manual (English)

How To Use The Visifault Visual Fault Locator

ATS Overhead Table Shelf System INSTRUCTION MANUAL

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Single Station Remote Alarm

Alarm Clock USER GUIDE

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

Instructions A Amp AC/DC Current Probe

3 WATT LED SPOTLIGHT Model No. SLM

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

Water Leak Detection System

PALLET JACK TON

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Oil and Coolant Circulating Heating System. Model - OCSM

Installation Guide Smart-UPS X External Battery Pack SMX120BP

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

600-GD & 600-GDL 600 SERIES GAS DETECTOR

Sip/Puff Switch User Guide

1/3 HP Submersible Sump Pump with Vertical Float Switch

Installation Instructions for Alarm Module Kit A043F059

INSTALLATION AND OPERATING INSTRUCTIONS

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Installation and Operation Guide PD4600 Series Converter Replacement

BroadBand PowerShield. User Manual

Installation and Operating Instructions (for chargers shown below)

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Customer Support

Automatic Phone-Out Home Monitoring Systems

Dehumidifier Users manual. For Models: DH45S DH65S

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

ROTOR LOADER OWNER S MANUAL

ReadyNet Easy Jack 2 Voice/Data and Data Only Owner s Manual PX-211d and PX-211v

How To Use A Cdm250 Digital Multimeter

INSTALLER S & OWNER S MANUAL

User Guide. HDMI Active Cable Extender. DVI-7370c

INSTRUCTION MANUAL MODEL PCD-88

BEP FD-2 CONTOUR MATRIX FUME DETECTOR

Owner s Manual & Safety Instructions

MODEL MAC-3 MULTIPLE APPLIANCE CONTROL

Mini-led spotlight with magnetic base

12 Volt 30 Amp Digital Solar Charge Controller

Bottom Loading Water Dispenser

Start Here Series. All-in-One Printer. Print Copy Scan. Includes Information on the: ESP 3250 All-in-One Printer ESP 3260 All-in-One Printer

81000 Series Aluminum Gate Valve Installation and Repair Manual

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

24.2L M.A.N. V12 Engine Module

COMPLETE MANUAL. Version: Optic. September 2015 (English), version 1.0. EnergyOT Optic Developed and Manufactured by Genoa Spark, lda Made in Portugal

User Guide for the Kidde RemoteLync. Remote Notification Device

Installation and Operating Instructions (for chargers shown below)

Part I - Installation

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Caller-ID on your TV!

12-Volt 10-Amp Regulated Power Supply

Mini Power Bank and Charger

PC Tab Security System INSTRUCTION MANUAL

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

Hot Water Urns. all models. Helpline. v3.0

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

USER S MANUAL HSC-24A

Manual for Fire Suppression & Methane Detection System

Ceiling Mount Air Handler Manual

Intelli-Time Alarm Clock model 13027

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

el-720 Carbon Dioxide Gas Leak Detector User s Guide

100 Series Maxi Internal Filters. Instruction Manual

Transcription:

Instructions - Parts List Leak Detection System 311200A For detecting leaks in your diaphragm pump system. Not for use in explosive atmospheres. Part No. 234576 120 psi (0.8 MPa, 8 bar) Maximum Air Input Pressure Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. See page 2 for Table of Contents. TI6850A Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441 Copyright 2005, Graco Inc. is registered to I.S. EN ISO 9001

Warnings Contents Warnings................................. 2 Overview.................................. 3 Installation................................ 5 Operation................................. 7 Maintenance............................... 7 Troubleshooting............................ 8 Technical Data............................. 9 Graco Standard Warranty................... 10 Graco Information......................... 10 Warnings The following general warnings are for the safe setup, use, grounding, maintenance and repair of this equipment. The exclamation point symbols alert you to general warnings and the hazard symbols refer to procedure-specific risks. Refer back to these warnings. Additional product-specific warnings may be found throughout the body of this manual where applicable. WARNING ELECTRIC SHOCK HAZARD Improper grounding, setup, or usage of the system can cause electric shock. Turn off and disconnect power at main switch before disconnecting any cables and before servicing equipment. Connect only to grounded power source. All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations. Do not expose to rain. Store indoors. EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals. For complete information about your material, request MSDS from distributor or retailer. Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer s warnings. Check equipment daily. Repair or replace worn or damaged parts immediately with genuine Graco replacement parts only. Do not alter or modify equipment. For professional use only. Use equipment only for its intended purpose. Call your Graco distributor for information. Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not kink or over bend hoses or use hoses to pull equipment. Comply with all applicable safety regulations. Keep children and animals away from work area. Do not operate the unit when fatigued or under the influence of drugs or alcohol. PERSONAL PROTECTIVE EQUIPMENT You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic fumes, burns, and hearing loss. This equipment includes but is not limited to: Protective eyewear Clothing and respirator as recommended by the fluid and solvent manufacturer Gloves Hearing protection 2 311200A

Overview Overview Usage The leak detector monitors air operated double diaphragm pumps for diaphragm rupture or other leaks that may contaminate the fluid being pumped. The system is made up of a main control box and two liquid detection sensors. The sensors are screwed into the air side of each diaphragm on the pump. When liquid is sensed by either one of the sensors, an alarm will sound, indicating a diaphragm rupture has occurred. The control box also has the ability to control an external device such as an alarm, light, or an air solenoid via an onboard relay. During normal operation, the LED indicators on the control box and each sensor will flash once per second, indicating proper operation. If a system fault or a leak is detected, an alarm will sound and the LED on the control box will blink three times per second. See table, page 8. Component Identification and Description Before you install the system, you should be familiar with the parts discussed in the following paragraphs. Sensors The sensors are mounted on the pump to detect liquid on the air side of the diaphragm. See FIG. 1, FIG. 2, and FIG. 5. The sensors use two methods of detection: optical and conductive. Having both conductive and optical sensors allows the sensor to detect as many liquids as possible. When both sensors are in air, both lights (blue and yellow) flash once per second. When the sensor is immersed in a conductive liquid, the blue LED will stop flashing. When the sensor is immersed in a liquid compatible with the optical sensor the yellow LED will stop flashing. Control Box The control box powers and monitors the sensors and sound the alarm when a leak is detected. The control box powers and reads the sensors every second. If the sensors detect liquid, the control box will alarm and set it s fault relay. Relay The relay has two sets of contacts that can be used to indicate an error by turning off a valve, lighting a light, etc. The contacts are located at J4 on the circuit board. See FIG. 6. There are two separate sets of Common, NO/NC contacts labeled CRS. C (Common) R is Reset, which is connected to Common during normal operation. (NO) S is Set, which is connected to Common when an error is detected. (NC) Sensors Conductive Optical Definition The two metal pins on the sensors. Controls the blue light and its signal is the white wire. The plastic dome in the center of the sensor. Controls the yellow light and its signal is the green wire. For example, if an air valve was held open during normal operation, the power to the valve would enter at C and exit at R. During normal operation C and R are connected and would open if liquid were detected by a sensor. This would stop the pump. Power must be maintained to the control box for the pump to operate. When the control box loses power it will set the relay. Both sets of CRS contacts are floating contacts and are electrically isolated from each other and the electronics on the control board. They do not supply power and should be used as a switch only. 311200A 3

Overview Control Box Sensors (234789) FIG. 1 TI6850A 4 311200A

Installation Installation 1. Mount the leak detector box in a convenient location. 2. Remove plugs from the pump, if plugs are present. 3. Remove the sensor covers. Connect the leak detector to the pump by screwing the sensors into the pump. Use thread sealant, as needed. See FIG. 5. 6. The control box can be powered by 230 VAC, 110 VAC, or 24 VDC. AC power is connected to J6 on the circuit board. The ground connection is the pin between the pins N and 110. See FIG. 6. a. To operate on 230 VAC, connect between pins marked N and 220. b. To operate from 110 VAC, connect between pins marked N and 110. FIG. 2 4. Route the sensor wires into the leak detector box through the fittings at the bottom of the box. Tighten the fittings. c. To operate from 24 VDC, connect to J1. J1 is marked for positive and negative polarity. Disconnect any power to the AC connector J6 if the system is to be powered by 24 VDC. See FIG. 6. Connect the leak detector to a 24 VDC power source OR a 110 VAC or 230 VAC power source. Do not connect to both. FIG. 3 5. Attach the lead wires into the terminal strip. See FIG. 4. The wires must be attached in the following order from left to right: black, red, white, green. 7. Connect an external ACPRH, air valve, etc. to the internal relay (CRS), if desired, using J4. See FIG. 6. C (Common) R is Reset, which is connected to Common during normal operation. (NO) S is Set, which is connected to Common when an error is detected. (NC) Black Red Green White FIG. 4 311200A 5

Installation Typical Installation Sensors TI6851A FIG. 5 Terminal Connections J3 (Sensor 1) J5 (Sensor 2) J1 (24 VDC) J6 (Line Voltage) Relay J4 (Relay) FIG. 6 Grounding 1. Follow the instructions in your pump manual to ground the Graco diaphragm pump system and check its electrical grounding continuity. 2. When the Leak Detector is powered by 230 VAC or 110 VAC, ground the Leak Detector by connecting the ground wire to terminal G on terminal J6. See FIG. 6. 6 311200A

Operation Operation Leak Detector Operation During normal operation, the LED on the leak detector control box and the sensors will flash once per second. If an error or a diaphragm rupture occurs, the LED and sensors will flash three times per second and the alarm will sound. The relay will trip and change state. To stop the alarm, press the reset button or remove power for 30 seconds. See FIG. 7. LED Reset Button FIG. 7 TI6850A Maintenance Clean Sensors Clean the sensors whenever the pump is disassembled for cleaning or inspection. 311200A 7

Troubleshooting Troubleshooting Problem Cause Solution Light flashes 3/sec and alarm sounds 1/sec. Sensor has detected liquid. Determine which sensor has detected the liquid. Inspect the diaphragm on the side which liquid has been detected. Replace diaphragm as necessary. Light flashes 3/sec and alarm sounds 3/sec. Light flashes 3/sec and alarm sounds 8/sec. Relay is set and light flashes 3/sec until reserve power is gone. One of the sensors is unplugged or has failed. The reset button is stuck in the down position. Loss of power to the leak detection system. To assure proper sensor operation, clean and dry the sensor head and the air side of the diaphragm pump. Remove the cover from the leak detector control box. Inspect the sensor connection for proper contacts and connections. If the problem persists, replace the sensor(s) as required. Remove any obstruction possibly depressing the reset button. If no obstruction exists, remove the cover and inspect the reset button for anything holding it in the down position. Once main power is restored, the alarm will clear and the system will resume normal operation. If the control box relay is wired to the air supply to the pump, the control box must be powered for the pump to work. 8 311200A

Technical Data Technical Data Input voltage range.............................. 12-28 VDC 100-130 VAC, 50/60 Hz 190-260 VAC, 50/60 Hz Maximum power consumption..................... 3 W Relay contact rating, 230 VAC..................... 60 W, 62.5 VA Maximum sensor pressure........................ 200 psi (1.4 MPa, 14 bar) Operating temperature range...................... 0-104 F (-18-40 C) Maximum sensor line length....................... 2 ft (.6 m) EMC compatibility............................... CE compliant Type of liquids that can be detected: water, oil, or any liquid compatible with polysulphone. 311200A 9

Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco s written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco. This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation. THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale. GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties. In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise. FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées. Graco Information TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505 All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. MM 311200 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441 www.graco.com Printed in USA 311200A 6/2005