Industrial Requirements for a Converged Network

Similar documents
Overview and Applications of PROFINET. Andy Verwer Verwer Training & Consultancy Ltd

Quality of Service in Industrial Ethernet Networks

PROFINET the Industrial Ethernet standard. Siemens AG Alle Rechte vorbehalten.

Demystifying Wireless for Real-World Measurement Applications

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

FOUNDATION Fieldbus High Speed Ethernet Control System

Efficient remote access to machines and plants with SIMATIC

Vorlesung Kommunikationsnetze Fieldbus Systems

Generic term for using the Ethernet standard in automation / industrial applications

Improving Current QoS Mechanisms

19 Comparison of Ethernet Systems

Hirschmann Networking Interoperability in a

Please purchase PDF Split-Merge on to remove this watermark.

EtherCAT Cutting Costs with High-speed Ethernet

Power network telecommunication

From Fieldbus to toreal Time Ethernet

Contents. Connection Guide. What is Dante? Connections Network Set Up System Examples Copyright 2015 ROLAND CORPORATION

High Speed Ethernet. Dr. Sanjay P. Ahuja, Ph.D. Professor School of Computing, UNF

Cabling LANs and WANs

Using installed Fieldbus Wiring to carry Ethernet Communications

Ethernet. Ethernet Frame Structure. Ethernet Frame Structure (more) Ethernet: uses CSMA/CD

HARTING mcon 1000 Introduction and features

Welcome. People Power Partnership PROFIdag 2013 Peter Van Passen Sales & Business Development Manager HARTING Electric 1/44

PROFINET Diagnostics Software and Tools

PROFINET. The leading. Industrial. Ethernet. Standard. The Benefits of PROFINET

High Speed Industrial Ethernet for Semiconductor Equipment

1. Communication Network Requirements

Telephone Company Lease Line Elimination. Dewey Day Principal Operational Technology Architect Pacific Gas & Electric

Introduction to PROFIBUS and PROFINET

Using Industrial Ethernet Networks for PROFInet

Wireless Sensor Networks

IP and Ethernet Communication Technologies and Topologies for IED networks

Central Office Testing of Network Services

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Dr. György Kálmán

the amount of data will grow. It is projected by the industry that utilities will go from moving and managing 7 terabytes of data to 800 terabytes.

Economic fiber optic solutions for public utility companies

Ha-VIS FTS 3000 Introduction and features

Designing Industrial Network - An Approach

IEC 61850: Communication Networks and Systems in Substations

Voice Over IP. MultiFlow IP Phone # 3071 Subnet # Subnet Mask IP address Telephone.

Analysis of Industrial PROFINET in the Task of Controlling a Dynamic System**

Based on Computer Networking, 4 th Edition by Kurose and Ross

Hybrid Simulation von Kommunikationsnetzen für das Smart Grid

Comprehensive Range of Industrial Products and Solutions

Understanding Device Level Connection Topologies

Network Infrastructure Considerations for Smart Grid Strategies By Jim Krachenfels, Marketing Manager, GarrettCom, Inc.

4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Ethernet Switch Wide Temperature

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Wireless Technologies for Industrial Applications

Systems Integration Track: Network Topology

IES-P3073GC Series. Industrial IEC port managed Ethernet switch with 7x10/100Base-T(X) and 3xGigabit combo ports, SFP socket.

How To Monitor And Test An Ethernet Network On A Computer Or Network Card

The Internet of Things: Opportunities & Challenges

Leveraging the Industrial Internet of Things (IOT) to Optimize Renewable Energy

TCP/IP Network Communication in Physical Access Control

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

Your single source for network transmission solutions.

Substation Communications Design - Legacy to IEC 61850

Security & Surveillance

Smart Solutions for Network IP Migration

4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Web Smart Switch

Manufacturing and the Internet of Everything

How a fibre connectivity solution can improve your company s performance

AVB Basics... 4 WHITE PAPER. Choosing AVB or CobraNet... 8

Data Link Protocols. TCP/IP Suite and OSI Reference Model

FOXBORO. I/A Series SOFTWARE Product Specifications. I/A Series Intelligent SCADA SCADA Platform PSS 21S-2M1 B3 OVERVIEW

Clearing the Way for VoIP

Fast Ethernet and Gigabit Ethernet. Networks: Fast Ethernet 1

ABB drives. Automation solutions Drives, PLC, motion, motors and safety

HARTING econ 4000 Introduction and features

Intelligent Device Management with DCS, PLC, and RTU

EtherDevice Switch EDS-726 Series

Supports O-Ring (recovery time < 30ms over 250 units of connection) and MSTP(RSTP/STP compatible) for Ethernet

AERONAUTICAL COMMUNICATIONS PANEL (ACP) ATN and IP

Remote I/O Network Determinism

Introduction to Ethernet

Process Control and Automation using Modbus Protocol

CONTROL LEVEL NETWORK RESILIENCY USING RING TOPOLOGIES. Joseph C. Lee, Product Manager Jessica Forguites, Product Specialist

HARTING econ 3000 Introduction and features

SGTech Europe 2015 September 22 th Amsterdam. Pedro Gama, Head of SCADA & Telecom Department at EDP Distribuição, SA

Going Critical. How to Design Advanced Security Networks for the Nation s Infrastructure. w w w. G a r r e t t C o m. C o m

Workshop PROFINET in Process Automation. Intern / Siemens AG Alle Rechte vorbehalten.

Validation of PROFINET plants

M2M I/O Modules. To view all of Advantech s M2M I/O Modules, please visit

DATA COMMUNICATION AND NETWORKS

MANAGEMENT INFORMATION SYSTEMS 8/E

Using Industrial Ethernet Switches to Assure Maximum Uptime White Paper

PROFIBUS AND MODBUS: A COMPARISON

Automation - future trends and innovation

SDH and WDM: a look at the physical layer

Intelligent Vibration Monitoring

Wireless Sensor Network for Performance Monitoring of Electrical Machine

Cisco - Ethernet 100BaseTX and 10BaseT Cables: Guidelines and Specifications

Latency on a Switched Ethernet Network

Basics in Energy Information (& Communication) Systems Substation Automation

The Most Complete Line of Media Converters in the Industry

Controlled Random Access Methods

Wireless Video Best Practices Guide

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Transcription:

Industrial Requirements for a Converged Network IEEE 802.3 SG DMLT Phoenix (AZ) Albert Tretter, Siemens AG

Ethernet captures more and more Applications Traditional Markets - Industrial Automation - Factory Automation - e.g. Material handling, Automotive Manufacturing, Transfer lines, - Process Automation - e.g. Oil, Gas, Chemical / Petrochemical, Food & Beverage - Energy Automation - Power Generation - e.g. Fossil Power Plants, Wind Turbines - Power Transmission and Distribution - e. g. Smart Grid Application - Building Automation - Climate Control - Fire Safety New Markets - Avionics - Fly-by-Wire, Passenger Experience, etc. - Railway Systems - Train Control - Railway Traffic Management Systems - Medical - Patient Imaging, - Patient Management Page2

A bit of History of Industrial Communication 1990 to 2000: non Ethernet Solutions dominated the market - Profibus, Interbus, Controlnet, Devicenet,.. Since 2000 Ethernet based solutions enter the industrial market Up to now Ethernet offers not the required real time capabilities (QoS) therefore specific Ethernet solutions appeared on the market, like: - EtherCAT, Ethernet Powerlink, TCnet, Profinet,... - All these solutions contain specific additions or adjustments to the "standard ethernet" in order to provide the required real time capabilities (QoS) for the industrial applications. Customers ask for one IEEE802.1/.3 standard based solution Page3

Solution: Converged Traffic Environment Multiple Traffic Classes Reserved Traffic Best Effort Traffic Scheduled Traffic One Ethernet cable Customers ask for a solution which: guarantees minimum latency for Scheduled Traffic and provides guaranteed bandwidth for Reserved Traffic and still allows the transfer of Best Effort Traffic on one network Page4

Definitions In this presentation the following definitions are use: - Scheduled Traffic: - used for the conveyance of cyclic control data like the input and output values of sensors and actors - Reserved Traffic: - used for the conveyance of streams like Audio/Video streams - Best Effort Traffic: - used for the conveyance of acyclic data like diagnostic information, access to a WEB server, Firmware Update,... Page5

Overview of Industrial Communication Requirements Process Automation Factory Automation Energy Automation Smart Grid Applications Motion Control 100ms Application Cycle or Control Cycle 31,25µs 10GBit/s 1GBit/s 100MBit/s Copper Fiber Wireless Linkspeeds Required Media 1GBit/s 100MBit/s Copper Fiber Page6

Examples of Industrial Communication Services Best Effort Traffic - Configuration - Diagnostic - Web Services - Events Reserved Traffic - Real Time Diagnostic (e.g. inspection, identification, tracking, counting and measurement) - Vision Systems Scheduled Traffic - General Automation to exchange analog an digital values e.g. manufacturing and process industry - Motion Control to exchange typical analog and digital values from actuators and sensors based on synchronized processes -Sampled Values (Current and Voltage) Multiple Traffic Classes Reserved Traffic Best Effort Traffic Scheduled Traffic One Ethernet cable Best Effort Traffic: Reserved Traffic: No guaranteed bandwidth Separate network Today Future: Only one Network: Guaranteed bandwidth for Best Effort Traffic Guaranteed QoS for Reserved Traffic Scheduled Traffic: Page7 Dedicated solutions to guarantee minimum latency, resources and bandwidth and often a separate network for the Best Effort Traffic is necessary Standardized solution to guarantee minimum latency, resources and bandwidth for Scheduled Traffic

Closed Loop Application based on Scheduled Traffic Typical traffic pattern for control traffic Closed Loop Application e.g. PLC C Tx Rx time Transmission Outputs Frame Tx Rx D D Transmission Inputs D D D D e.g. actuators or sensors Tx Rx Tx time Page8

Model of the cyclic transfer of and at Industrial Control applications Note: The controller and the devices are so called Bridged Endstations, means they have a 3 port bridge integrated IO-Device IO-Device IO-Device Controller Buffers for the of all devices Buffers for the of all devices Buffer for the Buffer for the Behavior of the Buffered Model of the and Output Data at the Controller and Devices: : - The devices update the buffer with the actual values of the in each ControlCycle - The will be transfered to the controller in each ControlCycle : - The controller updates the buffer with the actual processed values for the transfer to the devices - The will be transfered to the devices in each ControlCycle General: - The size of the and buffers at the controller and devices is configured at startup - In case of transmission errors the contend of the buffers remains valid and will be used for processing until a defined number of failures occur in one consecutive sequence Page9

Phase "Communicate": => Transfer a copy of the to the controller and => Transfer a copy of the to the devices ControlCycle (x-1) ControlCycle (x) ControlCycle (x+1) IO-Device IO-Device IO-Device Controller During this time the Scheduled Traffic is on the network Page 10

Phase "Compute": => Controller: Process the and calculate new for the next Cycle => Devices: Process the Outputdata and provide new for the next ControlCycle ControlCycle (x-1) ControlCycle (x) ControlCycle (x+1) IO-Device IO-Device IO-Device Controller Process the and calculate new for the next Cycle During this time Reserved Traffic or/and Best Effort Traffic is possible on the network Process the Outputdata and provide new for the next ControlCycle Process the Outputdata and provide new for the next ControlCycle Process the Outputdata and provide new for the next ControlCycle Page 11

Phase "Communicate": => Transfer a copy of the to the controller and => Transfer a copy of the to the devices ControlCycle (x) ControlCycle (x+1) ControlCycle (x+2) IO-Device IO-Device IO-Device Controller During this time the Scheduled Traffic is on the network Page 12

Phase "Compute": => Controller: Process the and calculate new for the next Cycle => Devices: Process the Outputdata and provide new for the next ControlCycle ControlCycle (x) ControlCycle (x+1) ControlCycle (x+2) IO-Device IO-Device IO-Device Controller Process the and calculate new for the next Cycle During this time Reserved Traffic or/and Best Effort Traffic is possible on the network Process the Outputdata and provide new for the next ControlCycle Process the Outputdata and provide new for the next ControlCycle Process the Outputdata and provide new for the next ControlCycle Page 13

Phase "Communicate": => Transfer a copy of the to the controller and => Transfer a copy of the to the devices ControlCycle (x+1) ControlCycle (x+2) ControlCycle (x+3) IO-Device IO-Device IO-Device Controller During this time the Scheduled Traffic is on the network Page 14

Phase "Compute": => Controller: Process the and calculate new for the next Cycle => Devices: Process the Outputdata and provide new for the next ControlCycle ControlCycle (x+1) ControlCycle (x+2) ControlCycle (x+3) IO-Device IO-Device IO-Device Controller Process the and calculate new for the next Cycle During this time Reserved Traffic or/and Best Effort Traffic is possible on the network Process the Outputdata and provide new for the next ControlCycle Process the Outputdata and provide new for the next ControlCycle Process the Outputdata and provide new for the next ControlCycle Page 15

Requirements for Scheduled Traffic ControlCycle (x+1) ControlCycle (x+2) ControlCycle (x+3) IO-Device IO-Device IO-Device Controller During this time the Scheduled Traffic is on the network Most important requirements for Scheduled Traffic: - Keep the Transmission Time (Phase "Communicate") as short as possible AND - Keep the jitter of the Transmission Time (Latency) as small as possible in order to get as much as possible processing time for the application Page 16

Benefits of Minimum Latency for Scheduled Traffic ControlCycle (x+1) ControlCycle (x+2) ControlCycle (x+3) Process the and calculate new for the next Cycle Benefits of Minimum Latency for Scheduled Traffic: - With the minimum Latency for the Scheduled Traffic possible processing time AND Page 17 the application gets as much as the network provides a maximum of bandwith for the Reserved Traffic and/or Best Effort Traffic Process the Outputdata and provide new for the next ControlCycle Process the Outputdata and provide new for the next ControlCycle Process the Outputdata and provide new for the next ControlCycle

Requirements for the ControlCycle (Application point of view) ControlCycle (x+1) ControlCycle (x+2) ControlCycle (x+3) IO-Device IO-Device IO-Device Controller Requirements for the ControlCycle: - ControlCycles in the range from 31,25us to 1ms are required - These ranges are necessary for 100MBit/s and also 1GBit/s Page 18

Benefits of LOW Latency for Scheduled Traffic Reasons for low latency: - Increase rate or speed of production - Increase product quality by increasing product accuracy - Reduce resources => Minimize Control Cycle Synchronization T R E N D Increased Number of Axes Faster Higher Complexity e.g. Movement Higher Accuracy More flexible Machines Reduce Resources Example (plastic moulding) Control cycle optimization through minimization of the response time and constant dead time is not an end in itself. In addition to enhanced quality, the aim is to save material through reduced wall thickness. Setpoint 2ms control loop 250µs control loop Example: Plastic cup moulding: Reduction of cup weigth per part by only 2 grams results in the following savings for the machine user: Cup weight today (g): 22 Cup weight target (g): 20 Parts / year: 54,568,421 Annual material saving (kg): >109,137 Savings per year ($ US): >200,000 Page 19

Industrial Communication Network Topologies Network topologies: star line ring and combinations Reasons for line topologies: - Applications are normally physically distributed in a linear manner, i.e. production lines - The network is tailored to the application, i.e. line topologies - To reduce total cost, 2-port-bridges are integrated into the end stations - Ring topologies are used to provide high availability - Minimize wiring effort avoid thick cable harness cable channel Influence of the topology to the QoS of Scheduled Traffic: In line topologies the interference of Scheduled Traffic by Best Effort Traffic increases the latency of the Scheduled Traffic dramatically. Page 20

Application Example 1: Printing Machine Finishing Unit Turner Bars Folder superstructure Folding Unit - multiple printing units per column - up to 10 axes per column - a segment can consist up to 10 column - each segment has its own real time network Guide Rollers (to route Paper Webs) Printing Unit Reel Stands and Paper Rolls ring network for control data and real time diagnostic data Recording PC for realtime diagnostic Requirements: Transmission Period: 1ms 125µs, in future 62,5us Typical length of control data: 12 60 bytes/axis Maximum number of axes: up to 100 in one segment - up to 1000 axes in huge printing machine Topology: daisy chain, ring, comb in combination with star High available network seamless redundancy Real time diagnostic for monitoring purposes - Payload of AV streams: ~400 bytes Payload of Best Effort Traffic : ~1500 bytes Future implementations can be more efficient if a converged network is available Page 21

Application Example 2: Wind Turbine Pitch bearing Gear Generator Spinner Requirements: Number of controllers: 1 Number of devices: 8 Typical length of control data: Input: 40 bytes Output: 40 bytes Rotor hub Blade Transmission Period: 125us in future 62,5µs Topology: line topology Real time diagnostic for monitoring systems (e.g. vibration) - Payload of streams: ~400 bytes Payload of best effort traffic: ~1500 bytes Yaw gear Tower Future implementations can be more efficient if a converged network is available Page 22

Application Example 2: Substation Automation Substation Automation according to IEC 61850 is an integral part in many Smart Grid Initiatives around the world! Traffic characteristics of Substation Automation according to IEC 61850: Scheduled traffic: L2 event trip messages (GOOSE) L2 cyclic traffic (Sampled Values) Best effort traffic MMS (Manufacturing Messaging Specification) e. g. SCADA File up- /downloads, device configuration,... Problem: MMS traffic, like SCADA file up- /downloads increase the latency of scheduled GOOSE and SV traffic GOOSE message SCADA traffic Future implementation can be more efficient if a converged Network is available IED = Intelligent Electronic DeviceM; MU = Merging Unit; P = Protection Relay; BP = Busbar Protection Relay; C = Bay Controller; NC = Network Clock Page 23

Summary: Industrial Requirements for Scheduled Traffic Performance requirements for Scheduled Traffic: Minimum latency: < 1µs @1000MBit/s in case of an empty transmission queue Guaranteed latency Topology independent Typical data size (payload size): 40-300 bytes Range of transmission period: 31,25µs 1ms Scheduled Traffic has higher priority than Reserved Traffic and Best Effort Traffic Preconditions for performance requirements Network topology: star, line, ring and combinations Network attributes - Maximum 64 hops - Maximum number of nodes (bridged end stations & end stations): 2000 - Maximum cable length: Standard length for Tx and Fx are required - High available network - seamless redundancy for Scheduled Traffic Payload size of Reserved Traffic (e.g diagnostic data): ~400 bytes Payload size of Best Effort Traffic: 1500 bytes * These are our best estimates derived from multiple use cases of the current and future industrial applications. Page 24

Summary: Industrial Requirements for the Physical Layer In Industrial Applications different media types are used and required. Ethernet offers the required physical media like: - 100Base-Tx and 1000Base-Tx - used for most applications - 100Base-Fx and 1000Base-Fiber: - used at harsh EMC environments - used to bridge long distances - Wireless: - used for mobile devices - 10GBase-Fx: - used as backbone Page 25

Objectives Objectives for a Converged Network for Industrial Communication: No or less configuration - ease of use Has to be operational with different link speeds Usage of the existing and future IEEE 802.3 Media types Connecting existing 802.1/.3 networks to converged networks shall be possible Flexibility: Changing the network (e.g. adding new stations, changing the topology) should be possible without influence on the latency of the Scheduled Traffic Robustness against miss-configuration High available networks are required (as shown in the slide "Substation Automation") Efficient usage of the existing bandwidth of the network required A converged network should have same transmission performance (e. g. related to the Bit Error Rate) like standard 802.1/.3 networks today Page 26

Thank you for your attention Albert Tretter Siemens AG Phone: +49(9621)-80-3135 E-Mail: albert.tretter@siemens.com Page 27