KILKENNY FIRE and RESCUE SERVICE



Similar documents
STANDARD SITE LICENCE CONDITIONS FOR RESIDENTIAL PARK HOME SITES IN GUILDFORD CARAVAN SITES AND CONTROL OF DEVELOPMENT ACT 1960 (AS AMENDED)

Caravan Sites and Control of Development Act Permanent Residential Mobile Home Sites Licence Conditions

EAST LINDSEY DISTRICT COUNCIL ~ RESIDENTIAL CARAVAN SITES CONDITIONS OF SITE LICENCE

Number 19 of Criminal Justice Act 2013

INSURANCE INTERMEDIARIES (GENERAL BUSINESS) ACT 1996 (As it has effect at 1st June 1999)

CITY OF TSHWANE METROPOLITAN MUNICIPALITY DRAFT PARKING METER BY-LAWS. 1.1 Act means the National Road Traffic Act, Act No 93 of 1996 as amended;

Decree of the Ministry of the Environment. on fire safety of garages

CITY OF ST. CA THARINE S. cn- Olc.4 BY-LAW NO. WHEREAS the Council of the Corporation of the City of St. Catharines, is

Fire Safety Requirements for Child Care Centre

PREFERRED REQUIREMENTS: WATER SUPPLIES AND ACCESS FOR SUBDIVISIONS IN RURAL ZONES

Crimes (Computer Hacking)

B-1 Buildings & Service Maintenance

Waste and Recycling Storage and Collection Guidance for Houses, Flats, Houses of Multiple Occupancy, New Builds, and Conversions.

UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS

Standard terms and conditions

Fence By-law. PS-6 Consolidated May 14, This by-law is printed under and by authority of the Council of the City of London, Ontario, Canada

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

CITY OF SURREY BY-LAW NO. 6569

REFERENCE NUMBER : PPC/54. POLLUTION PREVENTION AND CONTROL ACT 1999 POLLUTION PREVENTION & CONTROL (ENGLAND AND WALES) REGULATIONS 2000(as amended)

TORONTO MUNICIPAL CODE CHAPTER 470, FIRE SAFETY BOXES. Chapter 470 FIRE SAFETY BOXES

Code of practice for the depositing of skips on the highway. 4 th edition

PLEASE NOTE. For more information concerning the history of these regulations, please see the Table of Regulations.

BYLAW BEING A BYLAW OF THE TOWN OF OKOTOKS IN THE PROVINCE OF ALBERTA FOR THE PURPOSE OF REDUCING FALSE ALARMS

REFUSE AND RECYCLING STORAGE REQUIREMENTS

OREGON FIRE CODE Interpretations and Technical Advisories

By-law to Regulate Vacant Buildings

TORONTO MUNICIPAL CODE CHAPTER 880, FIRE ROUTES. Chapter 880 FIRE ROUTES

PLEASE NOTE. For more information concerning the history of this Act, please see the Table of Public Acts.

Trade Measurement (Weighbridges) Regulations 1993

Version Decision Number Adoption Date History 1 20\ /02/10 Adopted 2 3 4

Casino, Liquor and Gaming Control Authority Act 2007 No 91

CITY OF KELOWNA. BYLAW NO REVISED: November 28, 2011

Trade Measurement (Weighbridges) Regulations

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

BY-LAW CONCERNING THE SANITATION AND MAINTENANCE OF DWELLING UNITS

ON FIRE PROTECTION LAW ON FIRE PROTECTION CHAPTER I GENERAL PROVISIONS

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT

Liquor Control (Supply and Consumption) Bill

Queensland COAL MINING SAFETY AND HEALTH ACT 1999

PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems

Waste Management. GUIDANCE NOTES FOR DEVELOPERS AND LANDLORDS ON THE STORAGE & COLLECTION OF DOMESTIC REFUSE AND RECYCLING (December 2012)

STANDARD PLUMBING AND DRAINAGE REGULATION 2003

2015 No FINANCIAL SERVICES AND MARKETS. The Small and Medium Sized Business (Finance Platforms) Regulations 2015

Utilities and existing services

NO FALSE ALARMS BYLAW A BYLAW OF THE CITY OF VICTORIA

The following definitions apply with regard to requirements specified in this document:

2013 No. 233 ENVIRONMENTAL PROTECTION. The Timber and Timber Products (Placing on the Market) Regulations 2013

Trade Measurement (Weighbridges) Regulations 1997

Residential Plan Review Emergency Vehicle Access and Water Supply Permit Information Packet

CHAPTER INSURANCE LEVY ACT

Law No. (9) of 2012 Amending some provisions of Law No. (13) of 1997 Concerning the Civil Defense

Important Ontario Fire Code Information for Building Owners in the City of Windsor

COMPUTER MISUSE AND CYBERSECURITY ACT (CHAPTER 50A)

Number 11 of 2012 CRIMINAL JUSTICE (FEMALE GENITAL MUTILATION) ACT 2012 ARRANGEMENT OF SECTIONS

MONEYLENDERS ACT 1991

Planning Technical Advice Note: Waste bin storage and access requirements for new and change of use developments

DRAFT AMENDMENTS TO THE SECURITIES AND FUTURES ACT (CAP. 289)

CHAPTER 124B COMPUTER MISUSE

Guidance for Directors and Senior Managers on their Responsibilities for Workplace Safety and Health

ISLE OF MAN FIRE & RESCUE SERVICE FIRE PRECAUTIONS LOGBOOK. Website

Overview of Hotel Fire Safety Requirements

89 Avenue Road GP Ltd. Functional Servicing and Stormwater Management Report for 89 Avenue Road Re-Development City of Toronto

Taking In Charge Policy

TABLE OF CONTENT

Drainage By-law. WM-4 Consolidated April 18, This by-law is printed under and by authority of the Council of the City of London, Ontario, Canada

1.0 APPOINTMENTS 2.0 FIRE RISK ASSESSMENTS

BUILDING MANAGEMENT (THIRD PARTY RISKS INSURANCE) REGULATION CONTENTS

Greater Manchester Fire and Rescue Service

Liberty Mutual Insurance RISK ENGINEERING PROCEDURE. REP 07 Incident Planning For external use

Number 45 of Credit Reporting Act 2013

(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations;

CER Audit and Inspection System. part of the Petroleum Safety Framework

Supplementary Guidance Stiùireadh Leasachail. Managing Waste in New Developments A Stiùireadh Sgudal ann an Leasachaidhean Ùra

Town of Creston. Bylaw No. 1813

Housing and Planning Bill

Number 35 of Protection of Life During Pregnancy Act 2013

THE MURREE-KAHUTA DEVELOPMENT AUTHORITY ACT, 1986

Greater Dublin Strategic Drainage Study Regional Drainage Policies - Volume 2 New Development

Additional Tax, Penalty and Prosecution

CHAPTER 7 BUILDING ARTICLE 7-1 UNIFORM CODES Adoption. Board of Appeals. Annual Review

2008 No. 495 COMPANIES. The Companies (Trading Disclosures) Regulations 2008

Appendix 6 Storage and Collection of Waste and Recycling

PLEASE NOTE. For more information concerning the history of this Act, please see the Table of Public Acts.

City of Bettendorf Fire Alarm System Requirements

Small Business Grants (Employment Incentive) Act 2015 No 14

Fire Safety In High Rise Building

BERMUDA INTERNATIONAL COOPERATION (TAX INFORMATION EXCHANGE AGREEMENTS) ACT : 47

2015 No FINANCIAL SERVICES AND MARKETS. The Small and Medium Sized Businesses (Credit Information) Regulations 2015

CORPORATE PROCUREMENT UNIT SITE & SECURITY PROCEDURES BOSTON SPA VERSION 9 SEPT12

Workmen s Compensation (Amendment) Bill

approval of matters specified in conditions; and The Town and Country Planning (Development Management Procedure) (Scotland) Regulations 2013

THE REGIONAL MUNICIPALITY OF NIAGARA BY-LAW NO SIGN BY-LAW

CITY OF VINCENT CONSTRUCTION MANAGEMENT PLAN GUIDELINES

Transcription:

Report: GUIDANCE SPECIFICATION FOR FIRE HYDRANTS & FIRE FIGHTING Date: April 2008, Version 17.0 Prepared: Killian John Hennessy Senior Assistant Chief Fire Officer Approved: Adopted: Ciaran Cormican Chief Fire Officer For and on behalf of Kilkenny County Council

IRISH, BRITISH AND INTERNATIONAL STANDARDS Standards affect all areas of fire safety and are continually being developed to protect and support both consumers and professionals. With regards fire related products, standards are created to cover new areas or are updated to encompass the latest technological advancements. As standards continue to evolve to meet Irish, British, European and International criteria, it is crucial for specifiers/proprietors to know which standards apply to fire products. Standards provide common performance levels for both products and services. This ensures that a product is fit for the purpose it is intended. There are a large number of Irish, British and European Standards applicable to fire protection equipment and systems today. At the time of going to press/publication the Irish, British and European Standards referred to in this specification were believed to be true and accurate. However, they are the current standards, which may be revised from time to time, so we would ask you to use our information as a basic guide only. Compliance with this specification/guidance document does not of itself confer immunity from legal obligations. Page 2 of 14

LEGISLATION Statutory Instrument No. 30 of 1981 Fire Services Act, 1981 as amended Section 4 Offences Any person who contravenes (by act or omission) any requirement of Part III of this Act or of any regulation under this Act or any notice to which this Act applies shall be guilt of an offence. Section 5 Penalties 1) A person who is guilty of an offence by reason of a contravention of section 18(2), section 20 or section 20A or regulations made under section 37 shall be liable (a) on summary conviction, to a fine not exceeding 3,000 or to imprisonment for a term not exceeding 6 months, or to both, or (b) on conviction on indictment, to a fine not exceeding 130,000 or to imprisonment for a term not exceeding 2 years, or to both. 2) Where a person is convicted of an offence referred to in subsection (1) and there is a continuation by the person of the offence after the conviction, the person shall be guilty of a further offence on every day on which the contravention continues and for each such offence shall be liable (a) on summary conviction, to a fine not exceeding 500 for each day on which the offence is so continued or to imprisonment for a term not exceeding 6 months, or to both, but if a person is convicted in the same proceedings of 2 or more such further offences, the aggregate term of imprisonment to which the person shall be liable shall not exceed 6 months, or (b) on conviction on indictment, to a fine not exceeding 13,000 for each day on which the offence is so continued, or to imprisonment for a term not exceeding 2 years, or to both, but if a person is convicted in the same proceedings of 2 or more such further offences, the aggregate term of imprisonment to which he or she shall be liable shall not exceed 2 years. 3) A person who is guilty of an offence under this Act, other than an offence referred to in subsection (1) or (2), shall be liable, on summary conviction, to a fine not exceeding 3,000 or to imprisonment for a term not exceeding 6 months, or to both. 4) Where an offence under this Act is committed by a body corporate or by a person acting on behalf of a body corporate and is proved to have been so committed with the consent, connivance or approval of, or to have been facilitated by any neglect on the part of a person, being a director, manager, secretary or other officer of that body or a person who was purporting to act in any such capacity, that person shall also be guilty of an offence and shall be liable to be proceeded against and punished as if he or she were guilty of the first-mentioned offence. 5) Where the affairs of a body corporate are managed by its members, subsection (4) shall apply in relation to the acts and defaults of a member in connection with his or her functions of management as if he or she were a director of the body corporate. Section 10 Functions of fire authorities 1) A fire authority shall have the functions assigned to it by or under this Act. 2) A fire authority shall (a) make provision for the prompt and efficient extinguishing of fires in buildings and other places of all kinds in its functional area and for the protection and rescue of persons and property from injury by fire, and (b) establish and maintain a fire brigade, provide premises and make such other provision as it considers necessary or desirable for such purpose, and Page 3 of 14

(c) make adequate provision for the reception of and response to calls for the assistance of the fire brigade. 3) A fire authority shall, in the exercise of its functions under subsection (2), have regard (in addition to all other relevant considerations) to the nature of the fire hazards and the probable incidence and extent of fires in its functional area, the character of the area and the value of the property liable to be damaged by fires. Section 18 General obligations with regard to fire safety. 1) This section applies to premises or any part thereof put to any of the following uses (a) use as or for any purpose involving the provision of, sleeping accommodation, excluding premises consisting of a dwelling house occupied as a single dwelling: (b) use as, or as part of, an institution providing treatment or care: (c) use for purposes of entertainment, recreation or instruction or for the purpose of any club, society or association: (d) use for purposes of teaching, training or research; (e) use for any purpose involving access to the premises by members of the public, whether on payment or otherwise: and use for any other prescribed purpose, including i. premises used as a factory within the meaning of the Safety in Industry Acts, 1955 and 1980; ii. premises used as a store and subject to licensing under regulations made under the Dangerous Substances Act, 1972; iii. a magazine, store or registered premises within the meaning of the Explosives Act, 1875; and iv. an oil jetty within the meaning of regulations under the Dangerous Substances Act, 1972. v. any workplace. 2) It shall be the duty of every person having control over premises to which this section applies to (a) Take all reasonable measures to guard against the outbreak of fire on such premises, (b) Provide reasonable fire safety measures for such premises and prepare and provide appropriate fire safety procedures for ensuring the safety of persons on such premises, (c) Ensure that the fire safety measures and procedures referred to in paragraph (b) are applied at all times, and (d) Ensure, as far as is reasonably practicable, the safety of persons on the premises in the event of an outbreak of fire whether such outbreak has occurred or not. 3) It shall be the duty of every person, being on premises to which this section applies, to conduct himself in such a way as to ensure that as far as is reasonably practicable any person on the premises is not exposed to danger from fire as a consequence of any act or omission of his. 4) A fire authority may give advice in relation to fire safety to the owner or occupier of any premises or to any person having control over any premises. 5) Advice referred to in subsection (4) (a) may include a warning that a fire safety notice may be served under section 20 or that the owner or occupier may be liable to prosecution by reason of a contravention of a provision of this Act, (b) may be given on behalf of the fire authority by an authorised person authorised for the purposes of this section by a fire authority in accordance with subsection (11) of this section, and (c) may include recommendations, orally or in writing, to such persons concerning fire safety measures and procedures. 6) An authorised person may require a person having control over premises to which this section applies or to an owner or occupier of such premises (a) to carry out a fire safety assessment of such premises and to notify the fire authority of such assessment, and Page 4 of 14

(b) to carry out works specified under subsection (9) to such premises within a period of time so specified. 7) An authorised person may issue a warning, in writing, concerning any matter arising out of fire safety procedures and measures on such premises. 8) An authorised person may enter and inspect a premises to which this section or section 24 applies at all reasonable times for the purposes of this section. 9) An authorised person may specify works to be carried out at a premises to which this section applies and may specify a period of time within which such works are to be carried out. 10) Section 20(4) shall apply with any necessary modifications to works to be carried out under subsection (6). 11) A fire authority may authorise a person to be an authorised person for the purposes of this section by an order made by a city manager or a county manager as the case may be. 12) In this section authorised person means a person appointed in accordance with subsection (11) of this section.. Section 29 Public water supply for fire-fighting 1) The functions of a sanitary authority for the provision of a supply of water shall extend to the supply of water for fire-fighting purposes and the provision and maintenance of fire hydrants at such places as the fire authority requires. 2) Where a fire authority represents to a sanitary authority that reasonable provision has not been made for a supply of water for fire-fighting purposes, the sanitary authority shall consult with the fire authority as to the measures required and shall take such measures as may be agreed. Section 31 Damage to fire hydrant 1) Any person who interferes with, damages or obstructs a fire hydrant or any apparatus for drawing water from a main for the purpose of fire-fighting otherwise than in connection with operations of a fire brigade or for any purpose authorised by the sanitary authority shall be guilty of an offence. Statutory Instrument No. 497 of 1997 Building Regulations, 1997 Second Schedule, Part B, Fire Safety B5, Access and facilities for the fire service Access and Facilities for the fire service A building shall be so designed and constructed that there is adequate provision for access for fire appliances and for such other facilities as may be reasonably required to assist the fire service in the protection of life and property. Page 5 of 14

SECTION 1.0 - Hydrant details 1.1 OUTLET: Male, round thread, 62.5mm diameter, with cap chained to bolt of spindle flange. The depth of the hydrant outlet shall not exceed 300mm below finished ground level. 1.1 LOCATION: As far as possible hydrants shall be located in the footpath or grass margin adjoining the roadway near the kerb. Where it is found necessary to locate the hydrant in the grass, the area around the box shall be periphery of the box. The surface box and concrete surround shall be kept over the level of the adjoining surface and weathered to prevent polluted water from entering the hydrant pit. Hydrant pits shall be constructed so as to be self-draining. The location of hydrants shall be such as shall allow easy fitting of a standpipe and ready access of fire appliance without causing obstruction to other vehicles. 1.2 DEPTH: Spacer lengths under hydrant body shall be fitted to permit the top of false spindle being 75mm minimum to 225mm maximum below finished surface of footpath. 1.3 CHAMBER: The containing chamber shall provide not less than 75mm clearance around the hydrant body. Figure 1.0 Hydrant Chamber Hydrant chambers are provided with cast iron surface boxes, in compliance with the requirements of IS 261. The surface boxes are embedded in mortar on the chamber walls, and where any of the hydrants are located other than on a footway, driveway or roadway, are surrounded by 150mm concrete of 100mm in depth. Page 6 of 14

1.4 DRAINAGE: A 37.5mm minimum diameter drain from chamber to an open watercourse, shall be carried from a position at 50mm lower than the flanged base of the hydrant. 1.5 COVER: The hydrant cover box, with a 375mm x 225mm clear opening area, shall be placed centrally over the hydrant to permit freedom of affixing stand-pipe and operating key. 1.6 MARKER: A hydrant indicator plate, to BS 3251: 1976, shall be fitted on boundary wall or on marker against any fence provided at 450mm over footpath surface level. They should show the diameter of the watermain in millimetres on the upper part of the plate and the distance in metres of the marker from the hydrant on the lower part of the plate, as shown below: Figure 2.0 Marker Plates All the characters are black and the remainder of the front face should conform to colour reference No. 309 (Canary Yellow) of BS 381C. Some indicator plates may be present and are fixed to solid boundary walls, or where marker posts are utilised they should be constructed as shown below. Figure 3.0 Marker Plates Note Distance A preferably the height from finished ground level to the base of the fire hydrant marker plate should be 600mm Page 7 of 14

1.7 SPACING: Fire hydrants should be located such that- (a) The distance from the building is not less than 6m or more than 46m; (b) The distance from a hydrant to a vehicle access roadway or hard standing area for fire appliances is not more than 30m; (c) They are distributed around the perimeter of the building having regard to the provision of access for fire appliances. (d) Housing Estates / Residential Developments - Hydrants should be provided such that no house is more than 46 metres from a hydrant. 1.8 HYDRANT FLOW TESTING Kilkenny County Council Fire/Building Control Authority shall require for all fire safety certificate applications having a gross total internal floor area of 600m² or greater to demonstrate there is an adequate supply (volume) of firewater immediately available for the proposed application(s), either by means of an adequate number of fire hydrants, static storage or an open source of water. On a fire safety risk assessment basis building of any floor area may be requested to demonstrate there is an adequate supply (volume) of firewater immediately available for the proposed application(s), either by means of an adequate number of fire hydrants, testing of existing local/adjacent hydrants, static storage or an open source of water. The flows (l/s) and pressure (bar) from the existing fire hydrants should be confirmed in writing to the assessing authority. Therefore demonstrating there is an adequate supply of water for use in an emergency. Fire-fighters must have immediate access to adequate supplies of water. Calibration certificates for any flow meters utilised shall be submitted with the test results. Where a person is applying for a fire safety certificate it may be prudent for the applicant to seek specific advice, on a without prejudice basis, from the assessing Authority. A building shall be so designed and constructed that there is adequate provision for access for fire appliances and for such other facilities as may be reasonably required to assist the fire service in the protection of life and property. 1.9 SAFETY WARNING - PLASTIC/NYLON OUTLETS ON HYDRANTS Kilkenny Fire Authority is of the view and understanding that these fittings (plastic/nylon outlet) to fire hydrants pose an unacceptable level of risk of injury to both firefighters and members of the public. We make reference to Section 6.1 of BS 750 2006 and quote the following 6.1 The outlets shall be manufactured from copper alloy materials conforming to 5.3 and shall conform to 11.3 and 11.4. The outlet shall conform to the dimensions shown in Figure 3. Components involved in the attachment/retention of hydrant outlets shall not be made from plastics. See figure 4.0 below of such type of plastic/nylon outlet that is unacceptable to Kilkenny Fire Authority. Page 8 of 14

SECTION 2.0 - Water Supplies Figure 4.0 Plastic/nylon outlets on hydrants 2.1 - Residential/Housing Estate Outcome: The supply of water is sufficient to meet firefighting purposes. Fire Hydrants + Fire Water Main note (Residential/Housing Estate) All fire hydrants shall be located in accordance with Technical Guidance Document B of Building Regulations, 1997 & Technical Guidance Document B of Building Regulations, 2006 Statutory Instrument 497 of 1997. All fire hydrants to be installed in accordance with Recommendations for Site Development Works for housing works DoEHLG, BS 5306: Part 1: 2006 Code of practice for fire extinguishing installations and equipment on premises Part 1: Hose reels and foam inlets (BS 5306: Part 1: 1976 has be withdrawn since May 2006) and BS 9990: 2006 Code of practice for non-automatic fire-fighting systems in buildings, and marked in accordance with BS 3251: 1976 and installed in accordance with BS 750: 2006. Final verification should be sought from the fire authority for agreed layout of all hydrants and the number of water supply connections to the firewater ring main, preferably there should be more than one and, preferably from supplies obtained from different mains. <<<Housing developments with units of detached or semidetached houses of not more than two floors should have a water supply capable of delivering a minimum of eight litres per second (8 l/s) through any single hydrant.>>> OR <<<Multi occupied housing developments with units of more than two floors should have a water supply capable of delivering a minimum of 20 to 35 litres per second through any single hydrant on the development.>>> The flows (l/s) and pressure (dynamic bar) from the existing/adjacent/extended fire water main hydrants should be confirmed in writing to the fire authority, thus to demonstrate an adequate fire water main supply for the fire authority in the event of an emergency. Fire-fighters must have immediate access to adequate supplies of water. Page 9 of 14

2.2 - Commercial Development Industry Outcome: The supply of water is sufficient to meet firefighting purposes. Fire Hydrants + Fire Water Main note (Commercial Development - Industry) All fire hydrants shall be located in accordance with Technical Guidance Document B of Building Regulations, 1997 & Technical Guidance Document B of Building Regulations, 2006 Statutory Instrument 497 of 1997. All fire hydrants to be installed in accordance with Recommendations for Site Development Works for housing works DoEHLG, BS 5306: Part 1: 2006 Code of practice for fire extinguishing installations and equipment on premises Part 1: Hose reels and foam inlets (BS 5306: Part 1: 1976 has be withdrawn since May 2006) and BS 9990: 2006 Code of practice for non-automatic fire-fighting systems in buildings, and marked in accordance with BS 3251: 1976 and installed in accordance with BS 750: 2006. Final verification should be sought from the fire authority for agreed layout of all hydrants and the number of water supply connections to the fire water ring main, preferably there should be more than one and, preferably from supplies obtained from different mains. The water supply infrastructure to any industrial estate should have a minimum nominal diameter of 150mm and have a water supply capable of delivering a minimum of 20 to 75 litres per second through any single hydrant, depending on acreage of industrial estate. 2.3 - Transportation Outcome: The supply of water is sufficient to meet firefighting purposes. Fire Hydrants + Fire Water Main note (Transportation lorry/coach parks, multi storey car parks, service stations) All fire hydrants shall be located in accordance with Technical Guidance Document B of Building Regulations, 1997 & Technical Guidance Document B of Building Regulations, 2006 Statutory Instrument 497 of 1997. All fire hydrants to be installed in accordance with Recommendations for Site Development Works for housing works DoEHLG, BS 5306: Part 1: 2006 Code of practice for fire extinguishing installations and equipment on premises Part 1: Hose reels and foam inlets (BS 5306: Part 1: 1976 has be withdrawn since May 2006) and BS 9990: 2006 Code of practice for non-automatic fire-fighting systems in buildings, and marked in accordance with BS 3251: 1976 and installed in accordance with BS 750: 2006. Final verification should be sought from the fire authority for agreed layout of all hydrants and the number of water supply connections to the firewater ring main, preferably there should be more than one and, preferably from supplies obtained from different mains. All of these amenities should have a water supply capable of delivering a minimum of 25 litres per second through any single hydrant on the development or within a vehicular distance of 90m from the complex. 2.4 shopping, offices, recreation and tourism Outcome: The supply of water is sufficient to meet firefighting purposes. Fire Hydrants + Fire Water Main note (shopping, offices, recreation and tourism) Page 10 of 14

All fire hydrants shall be located in accordance with Technical Guidance Document B of Building Regulations, 1997 & Technical Guidance Document B of Building Regulations, 2006 Statutory Instrument 497 of 1997. All fire hydrants to be installed in accordance with Recommendations for Site Development Works for housing works DoEHLG, BS 5306: Part 1: 2006 Code of practice for fire extinguishing installations and equipment on premises Part 1: Hose reels and foam inlets (BS 5306: Part 1: 1976 has be withdrawn since May 2006) and BS 9990: 2006 Code of practice for non-automatic fire-fighting systems in buildings, and marked in accordance with BS 3251: 1976 and installed in accordance with BS 750: 2006. Final verification should be sought from the fire authority for agreed layout of all hydrants and the number of water supply connections to the fire water ring main, preferably there should be more than one and, preferably from supplies obtained from different mains. Commercial developments of this type should have a water supply capable of delivering a minimum of 20 to 75 litres per second to the development. 2.5 Education, health and community facilities Outcome: The supply of water is sufficient to meet firefighting purposes. Fire Hydrants + Fire Water Main note (Education, health and community facilities) All fire hydrants shall be located in accordance with Technical Guidance Document B of Building Regulations, 1997 & Technical Guidance Document B of Building Regulations, 2006 Statutory Instrument 497 of 1997. All fire hydrants to be installed in accordance with Recommendations for Site Development Works for housing works DoEHLG, BS 5306: Part 1: 2006 Code of practice for fire extinguishing installations and equipment on premises Part 1: Hose reels and foam inlets (BS 5306: Part 1: 1976 has be withdrawn since May 2006) and BS 9990: 2006 Code of practice for non-automatic fire-fighting systems in buildings, and marked in accordance with BS 3251: 1976 and installed in accordance with BS 750: 2006. Final verification should be sought from the fire authority for agreed layout of all hydrants and the number of water supply connections to the fire water ring main, preferably there should be more than one and, preferably from supplies obtained from different mains. <<Village Halls or the like>> Should have a water supply capable of delivering a minimum of 15 litres per second through any single hydrant on the development or within a vehicular distance of 100m from the complex. OR <<Primary schools and/or Single storey health centres and/or the like>> Should have a water supply capable of delivering a minimum of 20 litres per second through any single hydrant on the development or within a vehicular distance of 70m from the complex. OR <<Secondary schools, colleges, large health and community facilities and/or the like>> Should have a water supply capable of delivering a minimum of 35 litres per second through any single hydrant on the development or within a vehicular distance of 70m from the complex. Page 11 of 14

SECTION 3.0 Static Storage 3.1 STATIC STORAGE First and foremost, direct advice should be sought from a senior fire officer of Kilkenny Fire and Rescue Service. The size of the static storage tank(s) shall be agreed in writing with Kilkenny Fire and Rescue Service. The design, location and layout of these tank(s) shall be agreed in writing with Kilkenny Fire and Rescue Service. Prior to commencement on-site, the Kilkenny Fire and Rescue Service requires that you submit all supporting calculations and drawings indicating the location and access to the static storage tank(s). The static storage tank(s) should be monitored for water level. However, in brief we provide the following as guidance notes for static storage tanks 1. The fire authority requires that a static storage tank(s) is provided on-site - 1.1. To be sizing according to the risk assessment and 1.2. To provide an adequate supply of water for fire fighting. 2. The area around the static storage tank(s) shall be a suitable designed hard-standing area for fire appliances, see guidance in Table 5.2 of Building Regulations, Technical Guidance Document, Part B. The heaviest Fire Appliance currently in Kilkenny Fire Authority operational area is the high-reach appliance which is 18.5 tonnes. 3. If above ground tanks, the base of the static storage tank should a minimum of 1.0m off the adjacent hard-standing area, this will facilitate a gravity discharge of the entire tank contents to the eye of the main pump of the adjacent fire appliance. 3.1. At least 2no. (two) instantaneous female fire brigade couplings shall be provided from the base of each static storage tank each with hand lever operated isolation valves, and 3.2. 1no. (one) 4 (four) screw (hard suction) female fire brigade connection shall be provided from the base of each static storage tank with a hand lever operated isolation valve. 4. If below ground tanks, the [1] number of, [2] locations of, and [3] sized of access point to these tanks should be agreed in writing with Kilkenny Fire and Rescue Service prior to being placed. 4.1. If a number of tanks are to be connected together, the sizes of and number of connections between tanks shall be agreed in writing with Kilkenny Fire and Rescue Service. 4.2. Emergency access to these tanks should be through a fire hydrant cover box, with a 375mm x 225mm clear opening area in accordance with BS 750: 2006. NOTE adequate risk assessments must be done and documented in accordance with best practice. 5. A methodology of monitored the contents, water level, of this static storage tank(s) will be required. We propose a low level alarm probe to be fitted at a high level position, typically at 80% contents of the tank, this probe will be hard wired into the adjacent Fire Detection and Alarm System for continual monitoring. The graphics interface of the Fire Detection and Alarm System will be required. We also propose that a clear pipe be provided on the external façade of the tank(s) to allow for visual monitoring of the water level within the tanks, if above ground tanks are installed. 6. All tanks shall be signed in accordance with BS 3251: 1976, Specification Indicator plates for fire hydrants and emergency water supplies. 6.1. These signs should be of a permanent construction and should be appropriately sized. 6.2. The background and all text should be of photo-luminance properties. 6.3. The signs should be erected in permanent fashion and all an appropriate height to be legible at all material times. 6.4. The final layout of these signs with content should be agreed in writing with Kilkenny Fire and Rescue Service prior to manufacture and erection. 6.5. Example text could include the following FIRE-FIGHTING EMERGENCY, USE BY KILKENNY FIRE and RESCUE SERVICE ONLY BY ORDER 6.5.1. Volume of tank in m3 and litres 6.5.2. The continual maintenance if these tanks and contents contact details (24 hour basis) 6.5.3. If tanks content are monitored, where and by whom - contact details (24 hour basis) Page 12 of 14

SECTION 4.0 Vehicle Access 4.1 RESIDENTIAL TURNING BAYS Figure 5.0 Turning Bays and Table As extracted from Technical Guidance Document, Part B, the minimum size of turning circles for fire appliances are as specified in Table 1.0 below - Note the high reach platform in Kilkenny Fire Authority has a minimum carrying capacity of 18.5 tonnes. Table 1.0 Vehicle access route specifications Page 13 of 14

SECTION 5.0 Standards and Engineering Codes 5.1 IRISH STANDARDS AND BRITISH STANDARDS At the time of going to press, the Irish & British Standards referred to in this guide were believed to be true and accurate. However, they are the current standards, which may be revised, so we would ask you to use our information as a basic guide only. SECTION 6.0 - References 6.1 Recommendations for Site Development Works for housing works, November 1998, available from Department of Environment Heritage and Local Government, Government Publications, Postal Trade Section, 4-5 Harcourt Road, Dublin 2, ISBN 0-7076-6163-3, Telephone number 01-6613111, approx price 12.70 6.2 Technical Guidance Document B, Building Regulations 1997, Statutory Instrument 497 of 1997, available from Department of Environment Heritage and Local Government, Government Publications, Postal Trade Section, 4-5 Harcourt Road, Dublin 2, Telephone number 01-6613111 6.3 Technical Guidance Document B, Building Regulations 2006, Statutory Instrument 497 of 1997, available from Department of Environment Heritage and Local Government, Government Publications, Postal Trade Section, 4-5 Harcourt Road, Dublin 2, Telephone number 01-6613111 6.4 National guidance document on the provision of water for fire fighting, UK Water, Local Government Association, 2 nd Edition, May 2002 6.5 Municipal Water related to Fire Fighting and Fire protection, Chief Fire Officers Conference, Westport, Mayo 1986, Patrick J. Tobin & Co., Consulting Engineers, Galway. 6.6 BS 5588 Part 10 1997, Code of Practice for shops, offices, industrial, storage and other similar buildings. 6.7 BS 5588 Part 11 1991, Code of Practices for shopping complexes. 6.8 NFPA 1142, National Fire Protection Association, http://www.nfpa.org 6.9 Fire engineering, Chartered Institute of Building Services Engineers, CIBSE. (2003), 2 nd Edition, Chartered Institute of Building Services Engineers: London, (CIBSE Guide E). 6.10 Fire safety engineering; a reference guide, Chitty. R. and Fraser-Mitchell. J. (2003), Building Research Establishment, Crown Copyright, (BR 459). Page 14 of 14