Personal Comfort Systems (PCS)

Similar documents
EnergyPro Building Energy Analysis. Assisted Living Building

2006 Delta T Corporation dba Big Ass Fan Company

Energy Savings in High-Rise Buildings Using High-Reflective Coatings

Energy Efficiency Analysis for a Multi-Story Commercial Office Building. (LG Multi V Water II Heat Recovery VRF System)

Q Utility Rebate Report. Houston, TX

THE ROOFPOINT ENERGY AND CARBON CALCULATOR A NEW MODELING TOOL FOR ROOFING PROFESSIONALS

Energy Use in Residential Housing: A Comparison of Insulating Concrete Form and Wood Frame Walls

Energy Benchmarking Report for Lakeside Middle School. Millville, NJ

BUILDING PERFORMANCE METRICS

Energy Efficiency Analysis for a Multi-Story Commercial Office Building. (LG Multi V III Heat Recovery VRF System)

Using Time-of-Day Scheduling To Save Energy

Green Buildings Guidelines for Harvard

Commercial Building Energy Initiative Tenant Business Case

A MAJOR STEP IN APPLIED INNOVATION. KCC Climate Management System. Powered by

Continuous Energy Management at UC San Diego. Anna Levitt, P.E. Assistant Energy Manager June 13, 2013

Columbus State Community College. Climate Action Plan

Potential Savings with Events2HVAC Event Automation Software

Energy Efficiency. Energy Efficient Water Heating: Purchasing a new electric water heater. Hot water use has a significant impact on your bill.

Wireless Pneumatic Thermostat Technology Demonstration Test. Los Angeles Unified School District 333 S. Beaudry Ave.

Greening Data Centers

The Promise of Green Building in China

CENIC 2009 Conference

PENNSYLVANIA GREEN ENERGY LOAN FUND

Energy Efficiency Market Transformation Opportunities for Texas

Building Performance Evaluation Guide Version 1.7

Control of Computer Room Air Handlers Using Wireless Sensors. Energy Efficient Data Center Demonstration Project

IES <Virtual Environment> training. Trainee notes. ASHRAE 90.1 Appendix G - PRM Navigator. Version

Prioritizing Energy Efficiency Investments in Corporate Campuses: Opportunities and the Role of Policy

Integrating Landscape Irrigation Control With Building Automation Issues and Opportunities

Arizona State University. Understanding the Impact of Urban Heat Island in Phoenix

Whole House Dehumidification for Occupant Comfort and Energy Savings

Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial

Case Studies: Infrared Heating in Industrial Applications

Team Brundtland Executive Summary of Fort Worth

Increasing Energ y Efficiency In Data Centers

Greenhouse Gas Implications of HVAC Upgrades in Multi-Unit Residential Buildings

Methods for Effective Room Air Distribution. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas

Rules of Thumb Energy Efficiency in Buildings

August 16, Rebecca Duff ICF Interna tional 9300 Lee Highway Fairfax, VA Re: ENERGY STAR Version 2.0 Final Draft. Dear Ms.

Comparisons of HVAC Simulations between EnergyPlus and DOE-2.2 for Data Centers

Greening Your Business

Air Conditioning, Comfort and Energy in India s Commercial Building Sector

Building Energy Analysis Report

Introduction to Energy Codes & Green Building Programs

Measurement & Verification Plan

REAL OPERATING COST SAVINGS FROM RETRO- COMMISSIONING OPPORTUNITIES FOR SAVINGS IN ACADEMIC MEDICAL CENTERS

Agenda. Part I: Introduction to OptimumHVAC. Part II: Initial Energy Savings Analysis for MCO Main Terminal. Part III: Case Studies & Conclusion

STATE PROGRAMS. Residential. Commercial/Public. Other Resources. Weatherization (AHFC) Home Energy Rebate (AHFC) 5 Star+ New Home Rebate (AHFC)

RosevilleProject. LoE _ 2 Glass Products. You can reduce your cooling energy usage by 25% or more. Here is the proof.

POLK STATE COLLEGE CHILLER PLANT EVALUATION WINTER HAVEN, FLORIDA APRIL 2, C arastro & A ssociates, C&A# 5747

SIMULATION OF RADIANT COOLING PERFORMANCE WITH

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Energy Audit Data Collection Form

Heating & Cooling Efficiency

Roadmap for Enhancing Energy Efficiency in New Buildings

Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues

Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers

CCC/IOU Energy Efficiency Partnership and Campus Budget Challenges

Cost Effective HVAC Managing Energy and Performance. Steve, T. Tom, P.E., PhD Automated Logic Corporation

LEED Breadth. Introduction

Protocol for the Certification of Energy Simulation Software: First edition, December 2009

Geothermal Heat Pumps: A Pathway to Zero Net Energy (ZNE) for Schools, Homes and Businesses

The Impact of Demand-Controlled and Economizer Ventilation Strategies on Energy Use in Buildings

Protocol for the Certification of Energy Simulation Software: Second edition, September 2011

ASHRAE Level I Energy Audit June 2011

Energy Savings with Window Retrofits

CTBUH Copyright. What every tenant wants. Chairman, Jones Lang LaSalle. Dan Probst

Improving Sustainability in Campus Data Centers Click To Edit Master Title Style

This presentation is posted for public use. ACEEE does not endorse any product or service.

SOM. Data Needs to Achieve High-Performance Buildings. Teresa Rainey, PE, LEED AP BD+C Sustainable Engineering Studio, Washington, DC

Naval Support Activity Monterey: Energy Audit Use Case

CHAPTER 8 HVAC (Heating, Ventilation, and Air-Conditioning)

Multifamily Central Heat Pump Water Heating

Leveraging the Power of Intelligent Motor Control to Maximize HVAC System Efficiency

Energy Efficiency Workshops For Commercial Customers

ULTRA-EFFICIENT HVAC DESIGN AND CONTROL

AIA Provider: Colorado Green Building Guild Provider Number: Speaker: Geoff Overland

Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

New Approaches in Automating and Optimizing Demand Response to Solve Peak Load Management Problems

Best Practices in HVAC Design/Retrofit

Energy Audits. Good energy management begins with an energy audit

Heating and Cooling Policy at the EUI - rev last update: Heating and Cooling Policy at the EUI

Application Guide.

HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY

Los Angeles Community College District

After-hours Conditioned Air Policy Revised 8/2/11

Deep Energy Savings in Existing Buildings

Considerations for Building Controls

Sustainable Smart Laboratories

Trade Professional Alliance EE Programs Training. Napa, CA January 20, 2015 Mark Salavitch Trade Professional Manager, Bay Region

Energy Benchmarking Report for Lafayette Elementary School Bound Brook, NJ

Pilot Program Description: Building EMIS

White Paper Nest Learning Thermostat Efficiency Simulation for France. Nest Labs September 2014

ENERGY EFFICIENCY COMPARISON

Business Support

Advanced Energy Design Guide LEED Strategies for Schools. and High Performance Buildings

Dual Maximum VAV Box Controls

Energy Efficiency 101

GREEN BAY AREA PUBLIC SCHOOL DISTRICT Board Policy Manual ENERGY MANAGEMENT

Transcription:

Personal Comfort Systems (PCS) COMFORT AND CONTROL FOR YOUR OCCUPANTS, ENERGY SAVINGS FOR YOUR BUILDING.

C2M Team Inventors Katie Dewitt MBA Ankit Jain Ms Public Policy Professor Ed Arens Director of CBE Director of CEDR Anna Maybank MBA Chris Hallas MBA Anoop Honnekeri MS Architecture Professor Hui Zhang Research Specialist, CBE

Meet the Cast Fred the Facilities Mgr (Overall Comfort) Barry the Boss (Low Bills and Productivity) Erica and Eric the Employees (Individual Comfort)

The problem with current HVAC systems No, 68! 76! No, 72! And quit touching the thermostat! Why aren t you working?! 76 Fred the Facilities Mgr (Overall Comfort)!! 68 Barry the Boss (Low Bills and Productivity) Erica and Eric the Employees (Individual Comfort)

Plus, the energy savings potential is huge! Buildings = 81% of electricity Commercial = 35% of building electricity HVAC = 51% of commercial Plug load as percentage of electricity 15-30% 1 1 Energy Information Administration, Commercial Buildings Energy Consumption Survey (CBECS): Table E1A. Major Fuel Consumption (BTU) by End Use for All Buildings, September 2008.

Thermo-receptors; a source of information Provide the brain with information about environmental temperature. Are distributed over the whole body. Warm receptor Cold receptors

What does it mean to heat/cool individual body parts? Overall thermal comfort is dictated by local comfort Cooling head is most effective in warm environments Warming feet is most effective in cold environments Source:- Thermal sensation and comfort models for non-uniform and transient environments: Part I: Local sensation of individual body parts. Zhang et.al Building and Environment 45 (2010) 380 388

Preliminary surveys say: It works! 8 Occupants were comfortable even at extreme temperatures of 64 o F to 86 o F Improved productivity vs. neutral conditions Personal comfort system prototype Fan Foot warmer (40W) Fan (4W) Footwarmer

Expand the deadband for energy savings kwh/sqft 2.15 HVAC electricity in San Francisco 2.1 2.05 2 58% Energy saving 1.95 1.9 70-75 66-79 HVAC set point temperature o F Energy savings in other cities Phoenix- 24% Miami- 15% Chicago 31%

Simulations confirm payback potential Assumptions Size 4,982 m 2 / 53,826 ft 2 HVAC System Occupants Multi-zone VAV 18.5 m 2 / 200 ft 2 268 ppl Deadband 7 F wider 66 79 F Cost of system $100/unit $26,800 City % Savings kwh kwh saved Savings ($) Payback San Francisco 58% 79,044 $10,132 2.6 years Phoenix 24% 81,597 $7,260 3.7 years Miami 15% 55,414 $4,346 6.2 years Chicago 31% 94,061 $5,644 4.7 years Simulation software: Energy Plus. Building specs used: DOE reference building; Medium-size office building. [3 soties, 15 HVAC zones].

PCS can reduce hot/cold calls maintenance cost Data from CBE study Time per call-out 1.8 hr x Labor rate $35 = Cost per call-out $63 Significant avoided cost Uncomfortable occupants 20% Real estate owners: Significant savings Increased comfort happy occupants Reduced T/O Federspiel, C., 10/01/2000, Predicting the frequency and cost of hot and cold complaints in buildlings, Center for Environmental Design Research.

Combined savings improve payback, <3 years Assumptions Cost per call-out $63 Uncomfortable occupants 2 calls per year (1 hot/1 cold) 20% $6,754 Cost of system $26,800 City Energy Maintenance Total savings Payback San Francisco $10,132 $6,754 $16,885 1.6 years Phoenix $7,260 $6,754 $14,014 1.9 years Miami $4,346 $6,754 $11,100 2.4 years Chicago $5,644 $6,754 $12,397 2.2 years Simulation software: Energy Plus. Building specs used: DOE standard midium-size office building. 3 soties, 15 HVAC zones.

Productivity trumps all Types of productivity: Individual productivity Sick days, working from home Office climate war peace accord Loyalty, morale Who $/hour Hours needed kwh $0.10 1,000 hours Maintenance wage $35 3 hours Key Employees $50-100+ 1-2 hours

What s next: From pilot to scale Developed: United States UC Berkeley Owner-occupied commercial office space Commercial office space, government, universities Developing: India Local universities: CEPT/ NIT Jaipur New builds: HVAC/mixedmode India and China: Commercial office space 1 year 2-5 years 5 years + Pilot Pioneers Scale

Case study: Zynga Characteristics: Built in 1988, bought by Zynga in April, 2012 HVAC building, atrium with skylight (natural ventilation) USGBC Best Building Challenge 20% reductions in 2 yrs Applying for LEED certification Value proposition: Helping to meet energy savings goals & LEED points Culturally aligned innovative workplace Help meet CA Title 24: NZE commercial buildings by 2030 Go-to-market strategy: Validation: University pilot, endorsement from USGBC Partnership: Revenue share with leading furniture designers Target market: Innovative companies, property managers Promotion: Zynga & Cushman & Wakefield Source: interview with Preston Richards, property manager of 650 Townsend Street

Case study: Paharpur Business Center, India Characteristics: 50,000 sq ft office building, built in 1990 Widened deadband from 72 to 79 degrees Energy savings- ~60,000 kwh /yr Comfort mitigation; green plants and mesh chairs Value proposition: Rationale for widening set-point Energy savings Rationale for PCS employee comfort at higher set-point Help meet Energy Conservation Building Codes Go-to-market strategy: Validation: Indian pilot, Leverage ASHRAE & USGBC Partnership: Revenue share with accredited partners e.g. Schneider Electric Target market: New builds, Forwardthinking companies Promotion: Domestic & internationally via multinational partners

Key opportunities for development Partnerships Establish a collaborative partnership with a leading office furniture designer/manufacturer Product features Develop value-add features, i.e. Sleek design Furniture attachments A smart-desk suite Pioneers Identify pioneering companies and facilities managers in our premium markets

Thank you!

Appendix

Market sizes USA California India Office employees 72 M 8 M 166 M TAM $7 B $800 M $16 B 10% market share $700 M $81 M $1.6 B

Additional value created by enhanced productivity Warmth Concentration Cold Manual dexterity Individual control Performance

Replacing the Space heater is an easy win Advantages vs. Space heater: Reduced plug load Reduces effect on building HVAC Space heater Footwarmer Cost $50 $50 Watts 1,500 W 40 W City Months in use kwh saved Savings ($) Payback San Francisco 4 1,004 $100 0.5 years Phoenix 3 753 $75 0.7 years Miami n/a n/a n/a n/a years Chicago 5 1,256 $63 0.8 years

Comparing directly vs regular desk fan Advantages vs. Regular desk fan: Smaller footprint Less noise Less air turbulence Dial for speed setting Desk fan Cost $15 $15 Watts 15 W 4 W PCS fan City Months in use kwh saved Savings ($) Payback San Francisco 4 8 $1 66 years Phoenix 3 6 $1 88 years Miami n/a n/a n/a n/a years Chicago 5 9 $0.5 106 years

Why don t existing technologies solve this? 1.) Space heaters and personal fans: Facilities managers hate them! Safety High energy usage, yet thermostat doesn t change Take up plug load 2.) The Herman Miller C2 The C2 didn t do what it promised Heating and cooling the face didn t have the desired effect No impact on the office thermostat

Case stud: Wurster Hall, UC Berkeley Characteristics: Built in 1964 with minimal retrofits since due to lack of funding Central heating but no AC Value proposition: Enhanced employee control and comfort Financial reward for energy savings Culturally aligned with CBE s mission Go-to-market strategy Key partner: Universityendorsed furniture manufacturer Customer: Individual building managers Cost structure: One-off product sales and consultancy services Promotion: Offer educational demonstrations across campus