Single Port T1/E1 Tap



Similar documents
Installation Guide for. 10/100 to Triple-speed Port Aggregator. Model TPA-CU Doc. PUBTPACUU Rev. 1, 12/08. In-Line

ProfiShark 1G User manual

Installation Guide for Gig Zero Delay Tap and 10/100/1000BaseT Tap

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

TTL to RS232 Adapter User Guide

Installation Guide for. 10/100BaseT Port Aggregator Tap with Active Response. Models PA-CU-AR, PAD-CU-AR. Doc. PUBPACUARU Rev.

User s Guide OSXL-100-PE. Thermal Imaging Camera Enclosure. Shop online at omega.com SM

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

TERMS AND CONDITIONS

BroadBand PowerShield. User Manual

4 Port Hub User Manual

Original instructions Tina 3A/Aps Adaptor unit

MACTek Corporation. USB HART Interface. Users Manual

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

HotLok Pass Through Blanking Panel

User Manual (English)

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

VPCCCare. Virtual PC Center Service Warranty Program

Tina 2A/B Adaptor unit

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

How To Install A Power Supply (Uplast) With A Battery Pack

Commercial Cardiovascular Equipment

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

24.2L M.A.N. V12 Engine Module

USB 2.0 to 10/100Mbps Ethernet Adapter UE User Manual

USB 2.0 Hi-Speed 4-Port Hub User Manual

Model SRMD Setra Remote Monitoring Display

CITRIX SYSTEMS, INC. SOFTWARE LICENSE AGREEMENT

Quick Installation Guide. EtherFast 10/100M Switch. Model No.: SP624R.

2 To 1 Serial (RS-232) AUTO SWITCH. AS-251S User Manual

Quick Start Guide. Internet Conference Station X1-N6.

AVerMedia AVerKey imicro User s Manual

New MINIMAG Magnetic Stripe Reader

NECCare TM. NECCare Hard Disk Drive Retention Program. Express5800/Servers & M-Series SANs. HDD Retention 10/27/14

PS/2 Extender USER MANUAL.


Hi-Speed USB Port Hub Connect up to 7 Hi-Speed USB 2.0 or USB 1.1 devices

Old Company Name in Catalogs and Other Documents

JTAGjet. series SIGNUM SYSTEMS CORPORATION. USB 2.0 Driver for JTAGjet and ADM51. Installation Instructions

IEEE /ZigBee USB Dongle

MDM Zinc 3.0 End User License Agreement (EULA)

Dolphin 9900 Mobile Computers

Powerware Relay-Serial Card User s Guide

Installation. Basic Rack Power Distribution Unit AP9559

PEDAL POWER. User s Manual

Termulator II. for Windows. User s Guide. Termulator support is only available via tlsupport@givenhansco.com

Triton Systems of Delaware, LLC. Warranty Statement

Copyrights 2010 Victron Energy B.V. All Rights Reserved

USB Rover port USB m Cat 5 Extender. User Guide

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

END USER LICENSE AGREEMENT ( EULA )

User Guide. DVI-D Fiber Optic Cable. DVI + Digital Audio to HDMI Converter. HDMI to DVI + Digital Audio Converter DVI-3510a.

48-B-5-08-KIT 5-Wire Resistive Controller (USB) Specification Guide

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

MOTOROLA MOBILITY INC. LIMITED GLOBAL WARRANTY MOTOROLA TABLET COMPUTER

DVI to Analog Converter

USER MANUAL. Kramer Electronics, Ltd. Models:

inmarsat.com/isatphone

FriendlyNet PC Card for PowerBook computers

Triton Systems of Delaware, LLC Warranty Statement / Return Policy

ecopy Business Automation Services Software License Agreement

Model: HD11-ARC. Installation Guide

Triple Expansion Chassis

DISCRETE SEMICONDUCTORS DATA SHEET M3D848. CGD MHz, 20 db gain power doubler amplifier. Product specification 2002 Oct 08

Architect/Contractor Information Package

the Company will not warrant ANSI A156.2 Grade 2 lever Product installed in educational facilities and student housing.

Torpedo Design Concept Storage Server for Open Rack Hardware v0.3 ST-draco-chimera-0.3

Video Splitter VS-104 / VS-108 User's Manual

CONSOLE REMOTE I /O AC 9V

User Guide. HDMI Active Cable Extender. DVI-7370c

GPS 35 USB. installation and quick start guide

LAN9514/LAN9514i. USB 2.0 Hub and 10/100 Ethernet Controller PRODUCT FEATURES PRODUCT PREVIEW. Highlights. Target Applications.

Limited Warranty Letter for BYD Photovoltaic Module

How To Use A Ves-0116 Video Splitter With Audio And Video From A Computer Or Tv Aten (Ves-116)

QUICK INSTALLATION. 8-Port Telephony Gateway. Model: SPA8000

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

User Manual. Humidity-Temperature Chart Recorder. Model RH520

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

Take-2 by Nel-Tech Labs, Inc. Installation & User Manual

AB SCIEX LLC END USER SOFTWARE LICENSE AGREEMENT and LIMITED PRODUCT WARRANTY MarkerView Software, version 1.2.1

Software Hosting and End-User License Subscription Agreement

LCD5500Z / PKP-LCD v3.x Installation Instructions

APPLIED BIOSYSTEMS END USER SOFTWARE LICENSE AGREEMENT FOR INSTRUMENT OPERATING AND ASSOCIATED BUNDLED SOFTWARE AND LIMITED PRODUCT WARRANTY

ZIMPERIUM, INC. END USER LICENSE TERMS

ENGLISH FRANÇAIS DEUTSCH ESPAÑOL ÐÓÑÑÊÈÉ

Zetron Desktop Microphone Manual F

4 Port PCI Express Gigabit Ethernet PoE PSE Network Card

16-Port Gigabit Green Switch (TEG-S16Dg) 24-Port Gigabit Green Switch (TEG-S24Dg)

This product has the equivalent gain performance with the 14 element Yagi antenna.

PCI Express USB 2.0 Adapter Card

Low forward voltage High breakdown voltage Guard-ring protected Hermetically sealed glass SMD package

PoE+ Extender Switch User's Manual. Rev W

In-Situ Inc. Warranty / Terms & Conditions / Software License. This warranty policy applies to items that shipped prior to January 1, 2012.

SETUP GUIDE SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES

Kramer Electronics, Ltd. USER MANUAL. Rack Adapter Models: RK-1T2PT RK-2T1PT RK-3T RK-6T RK-9T RK-3TR RK-4PT RK-T2B RK-T2SB

16-Port Gigabit Green Switch (TEG-S16Dg) 24-Port Gigabit Green Switch (TEG-S24Dg)

Transcription:

Single Port T1/E1 Tap Model 2 CUSTOMER SUPPORT INFORMATION To order or for a technical information support: Phone: +33 3 88 10 18 30 or Fax: +33 3 88 10 18 35 Mail order: COMCRAFT 2, rue de la Mairie 67203 Oberschaeffolsheim - France Website: www.lan-wan-tap.com E-mail: info@lan-wan-tap.com

Page 2 L A N & W A N T E S T E Q U I P M E N T Index pages 1. General Information 3 2. Functional Description 4 2.1. Interface connectors 4 2.2. Activity/Link 4 2.3. Power 4 2.4. Power Failure 4 3. Installation 5 4. Rack Mount modules 6 5. Additional information 7 6. Disclaimer / Warranty 8

w w w. l a n - w a n - t a p. c o m Page 3 SP-T1/E1-Model 2 «T1/E1 NIC type» 1. General Information. The T1/E1 Tap avoids downtime in your T1/E1 networks. Once in place it enables you to monitor full and half duplex communication and move test equipment without breaking the circuit. It mirrors any packet size, bad CRC and sees both ends of full-duplex links. It is designed for half/full duplex networks. The no package loss and redundant power feature makes it ideal for security applications. The T1/E1 Tap is invisible to the network. It is fault tolerant, bypasses data on power failure, the monitor (Tap) port is nonintrusive to the network.

Page 4 L A N & W A N T E S T E Q U I P M E N T 2. Functional description 2.1 Interface connectors It has 4 RJ48 ports, port A and B are connected to the network, The Tap ports are connected to the analyzer. Network ports A and B are hardware cross-wired together. 2.2 Activity/Link Two (2) LEDS indicate Activity. Activity LED A lights up when a signal is received at port A, LED B for a signal received at port B. The brightness of the LED show signal strength/activity. 2.3 Power The T1/E1 Tap is redundant powered from the back. The external power can be chained as each power has 2 input sockets. Using redundant powering guarantees a maximum uptime off the tap/monitor ports. Two LEDs show the presence of power. 2.4 Power Failure The uninterrupted link in the network guarantees permanent network connectivity, also when power fails. Redundant powering guarantees maximum uptime of the monitor ports. No data is passed to the Tap port at power failure.

w w w. l a n - w a n - t a p. c o m Page 5 3. Installation a. Connect Server 1 to Network port A through a straight cable. b. Connect Server 2 to Network port B through a straight cable. * Server 1 and 2 communicate with each other after step a & b. c. Power the Tap with the 12V supply, the Power LED should light. d. Connect Analyzer 1 to Tap Port A through a straight cable. * Analyzer 1 receives a copy of the data send by Server 1. e. Connect Analyzer 2 to Tap Port B through a straight cable. * Analyzer 2 receives a copy of the data send by server 2.

Page 6 L A N & W A N T E S T E Q U I P M E N T 4. Rack Mounting. T1/E1 Tap - Model 2 The T1/E1 rack modules are designed to fit, together with rack mount plates, in 19 inch rack Systems. The Rack modules plug easily in the rack mount plates

w w w. l a n - w a n - t a p. c o m Page 7 5. Additional information. Connectors: 4 x RJ48, 8 pin Power: 12V stabilized / max. 100mA Operation temperature: 0 to 50 C Storage Temperature: -10 to 80 C Operating Humidity: 10 to 90%, no condensing Approval: CE Enclosure: Dimensions: Weight: Metal, structured black oven painted 142 x 82 x 30 mm (WxDxH) 210gr.

Disclaimer The information in this document is subject to change without notice. The manufacturer makes no representations or warranties with respect to the contents hereof and specifically disclaim any implied warranties of merchantability or fitness for any particular purpose. The manufacturer reserves the right to revise this publication and to make changes in the content hereof without obligation of the manufacturer to notify any person of such revision or changes. Warranty and Liability Comcraft warrants that this product is free from defects in material and workmanship at time of shipment. The warranty period is 3 years from the date of purchase. Comcraft assumes no liability for products that have been subjected to abuse, modification, misuse, or if the model or serial number has been altered, tampered with, defaced or removed. Comcraft is not liable under any contract, negligence, strict liability or other legal or equitable theory for any loss of use of the product, inconvenience or damages of any character, whether direct, special, incidental or consequential (including, but not limited to, damages for loss of goodwill, loss of revenue or profit, work stoppage or malfunction) Copyright This publication, including all photographs and illustrations, is protected under international copyright laws, with all rights reserved. Neither this manual, nor any of the material contained herein, may be reproduced without written consent of the author Trademarks The trademarks mentioned in this manual are the sole property of their owners. Rev 3.1 2007, Comcraft COMCRAFT 2, rue de la Mairie 67203 Oberschaeffolsheim France +33 3 88 10 18 30 +33 3 88 10 18 35 www.lan-wan-tap.com