D8X / D16X IPHONE INTERFACE

Similar documents
Amcrest 960H DVR Quick Start Guide

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST

Crow Limited Warranty. Print Version 017

Homeguard Wireless Home Camera Quick Start Guide

Self Help Guide. Please read the following carefully; Synopsis: Requirements: A Computer with a working RJ45 LAN Port All Belkin Modem Routers

NESS D Zone Control Panel and Dialler OWNER S MANUAL

Section 5: Installing the Print Driver

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

UTM Quick Installation Guide

NESS-APX. Training Manual

Self Help Guide IMPORTANT! Configuring Your Router With Your Modem. Please read the following carefully; This Guide refers to the following Products:

TC 3/10 Rev. A

Solution-16 Operators Manual ISSUE 1.60

for Windows Media Center User's Guide

Apps for Android. Apps for iphone & ipad INS584-3

OSM 2007 MONITORING SOFTWARE

EC150 BASIC SOFTWARE SETUP GUIDE. Read This First. Easy Clocking EC150 Setup Guide - Page 1

Global Monitoring + Support

NetworX TM NX-8E Alarm Panel. Application Note. NetworX NX-8E. 1.0 The NetworX NX-8E Alarm Panel

D24 USER S MANUAL ALARM CONTROL PANEL AND DIALLER. Ness D24 control panel User s manual A$15.00 INC GST. Revision 2

AC1200 Smart WiFi Router

User Manual Web Operating Panel AP User Manual. General Settings, Updating and Troubleshooting

First of all Let's look at how you would connect your laptop via Ethernet, as it is the easier of the two methods.

How To Use The Lutron Home Control+ App On An Ipad Or Ipod

You may refer the Quick Installation Guide in the package box for more information.

Configuring Napco Integration

EMBEDDED ACCESS CONTROL Hardware Installation Guide

WiFi DSL Modem Router

19 LCD / 8 CHANNEL DVR COMBO WITH 160GB HDD & 4 CAMERAS

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

Trademark Notice. Copyright Notice

VR8. User Guide Intruder Alarm System

Ethernet Radio Configuration Guide

Quick Start. Nighthawk X8 AC5300 Tri-Band WiFi Router Model R8500. Package Contents. NETGEAR, Inc. 350 East Plumeria Drive San Jose, CA USA

Event Link for Honeywell Galaxy 1.3 User Manual

How To Program A Talkswitch Phone On A Cell Phone On An Ip Phone On Your Ip Phone (For A Sim Sim) On A Pc Or Ip Phone For A Sim Phone On Iphone Or Ipro (For An Ipro) On

Arduino Wifi shield And reciever. 5V adapter. Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the shield:

Bright House Networks Home Security and Automation Mobile Application. Quick Start Guide

GV- RK1352 Card Reader

HRG App for Android Devices. User Guide

User s Information Guide R1A

Connecting to a Soundweb TM. London Network

Bright House Networks Home Security and Control Mobile Application

Serenity s Web & Mobile Remote Access Concept

Quick Installation and Setup for WinPower Software

AMAX 2100 / 3000 / en User Guide

Knowledge Base POS/C31A Troubleshooting

Iphone & Android App Smart GSM Home Alarm System

TE100-P21/TEW-P21G Windows 7 Installation Instruction

INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS. Viron Connect 10

Technical Support. Package Contents. D6300 WiFi ADSL Modem Router Installation Guide

GSM Interfacing Board

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

Nighthawk AC1900 WiF Range Extender

Ness D8x / D16x alarm control panel. User's MANUAL. A$15.00 Revision 5.6

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

Floating License Installation Guide for Windows

Vicon Flash Upgrade Software

3.5 EXTERNAL NETWORK HDD. User s Manual

Control4 Smart Home Safety and Security Guide

Access Control & Burglar Alarm Integration with KT-300

Diamante WiFi Wireless Communication User Guide. Linksys E1200

ElkRMS. Ness. Remote Management Software PC & Ness Touchscreen Edition. Part # v. 2.0

DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.

E-Mon Communication Gateway Utility Instructions for BACnet/mstp

USING YOUR DMX PROFUSION

ZeppelinAir AirPlay. set up

IP SERIAL DEVICE SERVER

SPC Connect Configuration Manual V1.0

User Guide HUAWEI UML397. Welcome to HUAWEI

Ness D8x / D16x alarm control panel

EASE Scan Tool Customers. SECTION I - Installation

Setting Up the ZigBee Ethernet Gateway

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

You will find the following information contained in this document: Requirements for performing a Self-Install of your Internet service

ABUS WIRELESS ALARM SYSTEM

Support. Package Contents. D6200 WiFi DSL Modem Router Installation Guide

tattletale User Guide Consumer unit version P a g e

Epson Stylus CX9475Fax. Start Here

ASUS WL-5XX Series Wireless Router Internet Configuration. User s Guide

Linksys E2500 Wireless-N Router Configuration Guide

SATO Network Interface Card Configuration Instructions

Remote Security Control

XFINITY HOME SECURITY

Innovative Electronics for a Changing World INDEX

Movie Cube. User s Guide to Wireless Function

Diamante WiFi Wireless Communication User Guide. CradlePoint CTR35

User Manual. Updated for igrill and ios 7

MDI FAQ. Version 8.1.0a Page 1 of 16

Network Installation Guide. WorkForce 610 Series Artisan 710 Series

BioStar Config Guide V1.0

Tooway KA-SAT Installation Guide

Using TCP/IP Remote to Control the V16Pro

DIRECT INTERNET DATA. User s Guide

APR-PRT3 Printer Module: C-Bus Programming Instructions

Setting up RDP on your ipad

Section 5: Connecting the Laser to Your Computer

EC500 BASIC SOFTWARE SETUP GUIDE. Read This First. Easy Clocking EC500 Setup Guide - Page 1

Transcription:

Ness icomms App D8X / D16X IPHONE INTERFACE SETUP GUIDE Revision 1.0.0

Table of Contents Copyright Notice... 3 1. Important Information... 4 2. Wiring Diagram... 5 2.1 RS232 Wiring Setup... 5 2.2 IP232 Ethernet to Serial Bridge Settings... 6 3. Ness icomms Configuration Setup... 8 4. Using the App... 9 4.1 Understanding the icons... 9 4.2 Arming / Disarming the panel... 10 4.3 Activating Emergency Alarms... 11 4.4 Viewing Zone Status... 12 4.5 Controlling Outputs... 13 5. Troubleshooting... 14 2

C O R P O R A T I O N Head Office: Ness Corporation Pty Ltd ABN 28 069 984 372 Ph +61 2 8825 9222 Fax +61 2 9674 2520 ness@ness.com.au Sydney Ph 02 8825 9222 Fax 02 9674 2520 sales@ness.com.au Melbourne Ph 03 9875 6400 Fax 03 9875 6422 nessmelb@ness.com.au Brisbane Ph 07 3399 4910 Fax 07 3217 9711 nessbris@ness.com.au Perth Ph 08 9328 2511 Fax 08 9227 7073 nessper@ness.com.au Adelaide Ph 08 8152 0000 Fax 08 8152 0100 adelaide@ness.com.au Copyright Notice All rights reserved. No part of this publication may be reproduced, transmitted or stored in a retrieval system in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of Ness. Ness reserves the right to make changes to features and specifications at any time without prior notification in the interest of ongoing product development and improvement. 2012 Ness Corporation Pty Ltd ABN 28 069 984 372 3

1. Important Information Ness D8x / D16x Versions The Ness icomms App only works with version 5.6 and above of the D8x and D16x. NOTE: To control the AUX outputs in the Ness icomms App you must be using a D8x/D16x PCB version 7.8 or above. To check what software version you are running in the D8x/D16x enter installer programming mode and enter P 99999999 E (eight 9's), it will then flash back the software version installed in the D8x/D16x. Or if you are running a D8x / D16x with a Navigator keypad, you can view the version number by pressing the Info button on the main screen, and it will display the D8x/D16x version number at the bottom of the screen. D8x / D16x Two way communications settings The two way communications on the D8x / D16x will only work if the following programming locations are enabled on the panel: P 199 E 1E ON: Send Address. 2E ON: Send Time Stamp 3E ON: Send Alarms. 4E ON: Send Warnings. 5E ON: Send Access Events. 6E ON: Send Zone Seal State. (D8x/D16x V6 and later.) 4

2. Wiring Diagram 2.1 RS232 Wiring Setup The Ness icomms app requires the D8x / D16x to be on a TCP/IP network. Although the panel doesn t have a TCP/IP connection you are required to use an Ethernet to serial bridge (Ness Part Number 101-244). Hardware / Parts Required: 1 x D8x-D16x SERIAL LEAD 3 WAY - PANEL TO DB9 (Ness Part Number: 450-185) 1 x IP232 ETHERNET TO SERIAL BRIDGE (Ness Part Number: 101-244) You need to connect the white serial plug into the D8x/D16x and connect the other end into the IP232 Ethernet to serial bridge as shown in the image above, and then you need to connect the IP232 Ethernet to serial bridge into a wireless router/switch. D8x/D16x Panel Black Blue White IP232 Ethernet to Serial Bridge PIN5 PIN2 PIN3 5

2.2 IP232 Ethernet to Serial Bridge Settings Before any connection can be made, you need to make a few changes in the IP232 Ethernet to serial bridge. To do this you need to open the IP232 Config Utility program which is available from the Ness download page on the website. You must be running at least version 1.1.0 or above of the IP232 Config Utility software. You need to make sure that you have your network cable plugged into the IP232 Ethernet to serial bridge and make sure that it s connected to the same network your computer is plugged into before continuing. Now you need to click on the Search button, this will go and search for these IP232 Ethernet to serial bridges on your network. Once it finds an IP232 Ethernet to serial bridge it will display down the bottom how many was found, as well as showing it in the dialog along with its MAC address and IP address. If it fails to find any IP232 Ethernet to serial bridges it will come up with the following error: 6

Once it finds your IP232 Ethernet to serial bridge, click on it and select Configure. You now need to enter / change some settings in the configure screen. 1. You need to make sure you set the IP address to a static IP address. 2. You need to enter in an IP address for this RS232 Ethernet to serial bridge. This should be on the same network range as your idevice. (e.g. 192.168.0.xx) If you are unsure what IP settings to use you might need to contact the network administrator. 3. You need to set the Baud rate to 9600 as that is what the D8x/D16x communicates on. 4. The TCP Port to accept connections should be set to 2401. This port number can be anything, but recommended to use the default 2401. 5. Once the settings have been entered, click on the Send Settings (to IP232) button. This will apply all the settings to the IP232 Ethernet to serial bridge. 7

3. Ness icomms Configuration Setup When you open the Ness icomms app for the first time it will display the configuration screen. Otherwise you can press and hold the D8x / D16x logo for approximately 3 seconds, to change the settings at any time. Once the configuration screen displays you need to enter in your panels connection settings. 1. Network Address, needs to be the IP address you set in the IP232 Ethernet to serial bridge. 2. Port, needs to be 2401 (or the port number you setup in the IP232 Ethernet to serial bridge) 3. Panel Type, select the panel type you are using. If you are using a 8 zone panel select D8, if your panel is a 16 zone panel then choose D16. Once you have entered your settings in press the Ness logo up the top and the App will try and make connection you re your panel. 8

4. Using the App When sending commands from the Ness icomms App, there might be a small delay in sending the data and receiving the data. 4.1 Understanding the icons Low Battery AC Mains Lost Normal Operation Fire Alarm Activated Panic Alarm Activated Medical Alarm Activated Display activation Alarms screen (Panic, Fire, Medical) Area 1 Disarmed Display zones Area 1 Armed Control Outputs Area 2 Disarmed Outputs not available with current PCB Area 2 Armed 9

4.2 Arming / Disarming the panel To arm or disarm the panel you need to bring up the on screen keypad. To do this you need to press the shield in the middle of screen. (No matter what icon is in the middle of the shield, it will always display the keypad on the screen). Arm to away mode To arm the panel, you need to press the Arm button followed by your user code then press the E button. The keypad will then disappear and the panel will then arm. (It may take serval seconds before the panel arms). Arm Home / Monitor mode To arm the panel to home/monitor mode, you need to press the Home / Monitor button followed by your user code then press the E button. The keypad will then disappear and the panel will then arm. (It may take serval seconds before the panel arms). Disarm the panel from away mode or Home / Monitor mode To disarm the panel, you just need to enter in your user code followed by the E button. (It may take serval seconds before the panel disarms). 10

4.3 Activating Emergency Alarms To activate an emergency alarm, you need to press the panic button, which is located down the bottom left of the screen. You then have 3 different alarms to choose from: Fire Panic Medical You need to slide the icon to the right to activate the alarm, and you will hear a beep sound to confirm the activation of the alarm. 11

4.4 Viewing Zone Status You can view the zone status from the panel by clicking on the Zones icon down the bottom of the screen. On an 8 Zone panel each zone is displayed on the screen. On a 16 zone panel, you will need to scroll down the list to view the other zones. There are 2 different states Zone Normal Zone Violated Each zone status is updated automatically when a zone is violated or become back to normal. 12

4.5 Controlling Outputs NOTE: To control the AUX outputs in the Ness icomms App you must be using a D8x/D16x PCB version 7.8 or above. If you find that your outputs icon is grayed out then you are using an older version board that is not supported. You will need to update the PCB. If your panel is supported you should see the icon like below which isn t grayed out. You can tap the on/off toggle button to activate/deactivate the output at any time. 13

5. Troubleshooting It won t display the version number when I press P99999999E on the keypad. Make sure you have programming location P 126 E 8 E turned OFF and try again. If you are using a Navigator keypad, you need to press the info button on the main screen and it will display the version number of the board at the bottom of the screen. Why is the outputs icon grayed out? The outputs can only be controlled by version 7.8 and above on the D8x / D16x. Although you can use the outputs on the keypads (such as the navigator keypad or KPX), there is no serial protocols in earlier boards to use outputs via the serial port. I can t control anything on the panel using the app? The Ness icomms app will only work if the following is enabled on the panel: P 199 E 1E: ON (Send Address.) 2E: ON (Send Time Stamp) 3E: ON (Send Alarms.) 4E: ON (Send Warnings.) 5E: ON (Send Access Events.) 6E: ON (Send Zone Seal State. (D8x/D16x V6 and later.)) Make sure your IP address isn t being used by another device on your network, and make sure you idevice is connected to the same network as the panel. Why doesn t the Panic, Fire or Medical buttons work? Make sure you have programming location P 126 E 1E: ON (Double key PANIC) 2E: ON (Double key FIRE) 3E: ON (Double key MEDICAL) Can I control my D8x / D16x over the internet using 3G? Yes, however you will need to enable Port Forwarding in your router. For more information on how to enable port forwarding please visit www.portforwarding.com for detailed step-by-steps on port forwarding. 14

Notes 15

16