GTS Gas-to-Steam Humidification System



Similar documents
GTS. New! Plus: PR0DUCT CATALOG. Vapor-logic 4 controller with: and LonTalk. New models GTS-500 and GTS-700. Gas-to-Steam Humidification System

GTS PRODUCT CATALOG. Vapor-logic 4 controller with: and LonTalk. Gas-to-Steam Humidification System

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Using waste heat. with gas-fired steam humidifiers Condair GS. Humidification and evaporative cooling

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

HEAVY DUTY STORAGE GAS

Commercial Gas Furnace Upflow

CE6500 Energy Recovery Ventilator

ECOCIAT. Domestic hot water heat recovery unit

HUMIDIFICATION DESIGN CHECKLIST: GETTING IT RIGHT THE FIRST TIME.

Commercial Gas Water Heaters

NAVIEN AMERICA INC FITCH AVENUE

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

CRAC Precision climate control units for data centres

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

Mechanical Rooftop Custom Capabilities

UDSA - UDSBD unit heater

SECTION MORTUARY REFRIGERATORS

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

2010 Residential Water Heater Replacement Check List

RPV - RP - RA air handling units

PMI-IF-H High Efficiency Gas Heat Units

"EC" Series Electric Humidifier

Commercial Gas Water Heaters

Commercial Boiler Systems and Controls

Element D Services Heating, Ventilating, and Air Conditioning

Cooling Capacity CFM in. w.c. (125 Pa)

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

Tankless water heaters

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Arapahoe County Residential Water Heater Installation and Inspection Guide

E-gas Instant Gas Water Heaters

SECTION HEAT PUMPS

Bring the fresh in. Dedicated Outside Air Systems

Climate chamber with illumination

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Commercial Gas Water Heater

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

Electric & Gas Water Heaters

Gas water heaters. Why Vaillant? Because warm water is our business for more than 135 years.

F9MXE. Product Specifications

XV 95. Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace PUB. NO.

Innovent LASER Packaged Fresh Air Conditioning Units

Commercial Gas Water Heaters

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

The Different Types of Air Conditioning Equipment for IT Environments

Air Conditioner Water Heater Model ACWH18

Chilled Water Precision Air Conditioner For Critical Application

Apartment and Communal Heating Solutions

Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information

Cooling Capacity CFM in. w.c. (125 Pa)

Aludesign K A T A L O G

SPIDERfire: Delivers high efficiency and real savings for today s businesses

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

G9MXE. Product Specifications

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

STERILIZERS, LABORATORY DRYING OVENS

Cooling Capacity CFM in. w.c. (125 Pa)

SIOUX HYBRID WATER HEATER

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

Cooking at the Speed of light!

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Some Criteria for Choosing a Steam Boiler for a Microbrewery

Installer s Guide 18-AH39D1-13

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

Glossary of Heating, Ventilation and Air Conditioning Terms

Ammonia Detection System Codes and Design Specifications

TANKLESS DURABILITY Tankless Product Guide

Electric Flow Boiler

CHILLED WATER DATA ROOM UNITS

Technical Specifications for West Campus Data Center HVAC System

SOLI TANKLESS PRODUCT GUIDE

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Operation and Installation Manual. Max Series

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Oil and Coolant Circulating Heating System. Model - OCSM

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

User's Instructions. Alpha HE CB25/33 and HE SY25

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Technical data. Danfoss DHP-A

Better Boilers.

Material test chamber with mechanical convection

Transcription:

GTS Gas-to-Steam Humidification System Gas has lowest energy operating costs The industry s first and best-selling gas-to-steam (GTS ) humidifier continues to be your best choice for reducing energy costs both consumption and demand charges. To calculate how much you can save by switching from an electric humidifier to a gas humidifier, contact your DRI-STEEM distributor. Convenient Web-enabled remote access with Vapor-logic4 DRI-STEEM s fourth-generation controller Vapor-logic4 allows, as standard, humidifier control from a keypad or from a Web interface. This provides the capability to securely set up, view, or adjust humidifier system functions from virtually anywhere and at any time. Connect with Modbus, BACnet, or LonTalk GTS humidifiers with Vapor-logic4 are fully interoperable with Modbus, BACnet, and LonTalk systems. Modbus is Vapor-logic4 s native language, or it can converse easily with a building automation system using optional BACnet or LonTalk. More benefits of the best-selling gas-to-steam humidifier: 8 unit capacities from 34 272 kg/h, including new GTS-500 and GTS-700 models Easy software updates through the USB port on the Vapor-logic4 board View operational data from the keypad or from the Web interface Accurate, responsive, adjustable RH control due to full burner modulation and PID control Capacity range up to 4 352 kg/h (16 units under one controller) Automatically cools discharged hot water to 60 C to meet governing code safety requirements Enclosures for virtually any environment. Indoor and outdoor; factory-installed Space conscious and streamlined. All humidifier components are contained within enclosures no separate control cabinets or wiring subpanels Full service access. Lift-off panels remove for easy access to all connection points New! Vapor-logic 4 controller with: Web-enabled remote access Modbus, BACnet, and LonTalk interoperability Plus: New models GTS-500 and GTS-700

GTS features DRI-STEEM dispersion: Proven and guaranteed When it comes to absorption performance, competitors don't come close to DRI-STEEM s proven and guaranteed dispersion systems. Define your dispersion requirements and DRI-STEEM will meet or exceed them. Guaranteed. Save even more energy with our high-efficiency tube option An option for new and existing Ultra-sorb and Rapid-sorb dispersion assemblies, highefficiency tubes provide significant energy savings: Wasted energy is reduced by up to 85%. Airstream heat gain and condensate are also significantly lowered. Brave the cold with our heated/ventilated outdoor enclosure Third-party testers verified that our outdoor enclosures provide reliable operation under extreme conditions. Proven performance Control to ±3% RH Steam output rangeability up to 40:1 Low nitrogen oxide (NOx) emissions of less than 20 ppm On-board diagnostics verify system operation 93% burner efficiency rating Variable speed blowers and modulating gas valves provide consistent humidity output Designed and tested to meet ARI-640 humidification standard Application flexibility Capacity range to 272 kg/h for each unit; link up to 16 units for capacity to 4 354 kg/h Supports all water types: tap, softened, reverse osmosis, or deionized; easy to field convert if water type changes Supports natural and LP gas Outdoor enclosure available for outdoor operation in any climate CE approved for sealed combustion Requires only two-sided access, allowing installation in tight spaces Horizontal or vertical venting Uses affordable Category 1 venting materials for all options, including sealed combustion Minimal maintenance Cleanout plate and removable panels provide easy access for inspection and servicing Use of softened water significantly reduces maintenance requirements End-of-season autodrain minimizes microbial growth Controller-operated drain and flush removes precipitated minerals from evaporating chamber Easy water level control access Built-in safety Fully CE compliant design Self-contained infrared gas burners provide safety and reliability Gas valves close if the flue becomes blocked, shutting down humidifier operation Low-water sensing mechanism with redundant backup shuts down burners in a low water condition Can be vented with other Category 1 appliances Can interlock with combustion air dampers Freeze protection Page 2 DRI-STEEM GTS humidifier

Vapor-logic4 controller Accurate, responsive control Vapor-logic, DRI-STEEM s humidification system controller, has been setting the standard for exceptional functionality and accurate RH control since 1992. The fourth generation controller, Vapor-logic4, retains the qualities that established the Vapor-logic reputation, plus offers several new capabilities, including: Web interface enables remote, simultaneous, secure access from anywhere, at any time. Modbus, BACnet, and LonTalk allow interoperability with multiple building automation systems (BAS). Up-time optimizer keeps humidifiers operating through conditions such as fill, drain, or run-time faults, as long as safety conditions are met, minimizing production down-time. USB port on Vapor-logic4 allows easy software updates, and data backup and restore capability. Insert a USB flash drive into the Vapor-logic4 board s USB port to perform software updates, or to back up and restore data. PID control provides accurate, responsive, and adjustable relative humidity control. Real-time clock allows time-stamped alarm and message tracking, and accurate drain and flush scheduling. Tank temperature sensor, mounted on the evaporating chamber, allows over-temperature protection, freeze protection, and tank preheating, allowing rapid response to a call for humidity. Auxiliary temperature sensor allows air temperature monitoring. Programmable outputs allow remote signaling or device activation, and are easily configured during the setup process. Multiple-humidifier control allows staged control of up to 16 humidifiers with one controller. Enhanced diagnostics include: Test outputs function, using the keypad or Web interface to verify component operation Test humidifier function, by simulating demand to validate performance Data collection of RH, air temperature, water use, energy use, alarms, and service messages for viewing from the keypad or Web interface Factory commissioning of humidifier and control board guarantees a reliable, fast installation, minimizing field installation requirements. All units are operated and tested, heating water in each tank before shipping. Use the Vapor-logic4 keypad or the standard Web interface, shown here, to control your GTS humidification system. Preconfigured but easily changed. Just go into the Setup menu to change a factory setting if, for example, a transmitter changes. DRI-STEEM GTS humidifier Page 3

GTS specifications, capacities, and weights Table 4-1: GTS specifications, capacities, and weights GTS model Maximum steam capacity Input Water usage at maximum capacity** Tank volume Operating weight GTS Shipping weight GTS with outdoor enclosure Operating weight Shipping weight I max A* kg/h kw litres/hr litres kg kg kg kg 230 V 50 Hz GTS-100 34 29 34.1 185.5 320 170 365 230 2.8 GTS-200 68 59 68.1 185.5 320 170 365 230 2.8 GTS-300 102 88 102.2 200.6 385 205 455 270 4.0 GTS-400 136 117 136.3 200.6 385 205 455 270 4.0 GTS-500 170 147 170.3 287.7 500 270 660 430 5.5 GTS-600 204 176 204.4 287.7 500 270 660 430 5.5 GTS-700 238 205 238.5 336.9 635 320 795 475 7.0 GTS-800 272 234 272.5 336.9 635 320 795 475 7.0 Note: * Add 8 full load current for GTS models with an outdoor enclosure fitted with heaters and 1 full load current without heaters. ** Add 10% to account for skim and automatic drain/flush features if utilized (standard water units only). Table 4-2: High altitude derate Altitude Input derate metres % 0 610 0 610 765 2 765 915 4 915 1065 6 1 065 1 220 8 1 220 1 370 10 1 370 1 525 12 1 525 1 675 14 1 675 1 830 16 1 830 1 980 18 1 980 2 135 20 2 135 2 285 22 2 285 2 440 24 Capacity notes At sea level, approximately 352 kj are required to raise the temperature of one kilogram of water from 16 C to 100 C. An additional 2 257 kj are required to change the state of one kilogram of 100 C water to vapor. Another factor to consider is condensation steam loss from piping. Use the following general steam loss guidelines: Vapor hose: 0.22 kg/h/m Insulated pipe: 0.07 kg/h/m Hard pipe and dispersion tubes: 0.7 kg/h/m High-efficiency dispersion tubes: 0.298 kg/h/m For more detailed information about condensation steam loss, see the DRI-STEEM Design Guide. LP gas All models operate at rated kw input. High altitude A derate in kw input exists when operating units at a high altitude above 600 metres. See Table 4-2 for high altitude derate information. Page 4 DRI-STEEM GTS humidifier

GTS dimensions Figure 5-1: Dimensions Top view Front view Side view G H F C D J L 127 mm M E B K A OM-1203 Table 5-1: Dimensions Description GTS-100 GTS-200 GTS-300 GTS-400 GTS-500 GTS-600 GTS-700 GTS-800 mm mm mm mm A Overall length 1 380 1 380 1 380 1 380 B Overall width 670 822 1 076 1 229 C Shroud height 1 040 1 040 1 040 1 040 D 457 432 432 413 Flue position E 330 397 475 533 F Flue diameter 127 178 203 254 G 356 521 743 895 Steam outlet position H 295 295 295 295 J 330 330 330 330 Fill valve connection position K 330 330 330 330 L 222 222 222 222 Drain position M 203 203 203 203 DRI-STEEM GTS humidifier Page 5

GTS outdoor enclosure, Figure 6-1: Outdoor enclosure Heated and ventilated outdoor enclosure DRI-STEEM offers a robust and affordable enclosure for mounting the GTS humidifier outdoors. Independent testing has proven that the GTS installed within this new outdoor enclosure provides errorfree ignition and reliable operation under extreme conditions. The GTS humidifier with outdoor enclosure are assembled at the factory. The unit ships complete to the job site, ready for easy-toconnect gas, water, electrical, and steam field connections. The outdoor enclosure has heating and venting systems that ensure humidifier operation in temperatures from 40 C to 48 C. The outdoor enclosure can also be ordered without the heater package, or with a factory-supplied curb. Outdoor enclosure features Protects in cold and hot climates. To ensure complete safety and operation in all climates, the outdoor enclosure has heating and venting systems that ensure humidifier operation in temperatures from 40 C to 48 C. The outdoor enclosure can also be ordered without the heater package. Install on the ground or roof. The outdoor enclosure is ideal for facilities that have limited interior space. Factory constructed. The outdoor enclosure ships complete with a GTS unit preinstalled and tested, ready to easily connect to gas, water, steam and electricity. Certified, tested and proven. GTS humidifiers and outdoor enclosures are CE compliant for outdoor operation. In addition, in-house testing has proven that the GTS and outdoor enclosure provide error-free ignition and reliable operation under extreme conditions. Easy service access. Easily removed panels provide access to all internal components. Robust design. The outdoor enclosure is ruggedly built to completely protect internal components. The enclosure is constructed of heavy-duty galvanized steel and is fully insulated. Serviceable gaskets on access panels ensure a tight seal. Optional curb. Factory-supplied curb provides base clearance and allows easy installation. Page 6 DRI-STEEM GTS humidifier

GTS outdoor enclosure Figure 7-1: GTS outdoor enclosure with standard or optional steam outlet, elevation view Standard steam outlet Optional steam outlet Flue piping (by installer) Flue piping (by others) Steam outlet (See Note 1) Steam outlet (See Note 1) Ventilation fans Combustion air intake 38 mm knockouts 102 mm o.c. GTS humidifier Ventilation fans Combustion air intake 38 mm knockouts 102 mm o.c. GTS humidifier Pipe chase Emergency drain Power block Pipe chase Emergency drain Power block OM-1228M OM-1227M Notes: 1. The outdoor enclosure has two available steam distribution configurations. The standard configuration has a steam outlet at the back of the outdoor enclosure for connecting to steam dispersion unit piping. The optional internal steam distribution configuration routes steam within the outdoor enclosure and down through the enclosure pipe chase into a building. 2. There are three knockouts located on the right and left side of the enclosure. Run the electrical power and gas piping into the enclosure at these knockouts. 3. Piping from the GTS unit to the steam outlet is stainless steel pipe. Piping from the steam outlet to the dispersion assembly is provided by the installer. Choose interconnecting steam piping material that is appropriate for the application (e.g., for high-purity steam applications, consider using stainless steel interconnecting steam piping). 4. The GTS housed in an outdoor enclosure will operate properly in operating temperatures of 40 C to 48 C. Table 7-1: Outdoor enclosure dimensions Description GTS-100 GTS-200 GTS-300 GTS-400 GTS-500 GTS-600 GTS-700 GTS-800 mm mm mm mm A Enclosure height 1 388 1 388 1 388 1 388 B Enclosure width 660 813 1 067 1 219 C Enclosure length 1 454 1 454 1 454 1 454 Figure 7-2: Outdoor enclosure mounted on a curb Figure 7-3: Outdoor enclosure mounted flush A 356 mm B C OM-7431 B C OM-7430 DRI-STEEM GTS humidifier Page 7

GTS steam dispersion options Expect quality from the industry leader For more than 40 years, DRI-STEEM has been leading the industry with creative and reliable humidification solutions. Our focus on quality is evident in the construction of the GTS humidifier, which features cleanable, stainless steel construction, and an industry-leading two year warranty that covers all parts. For more information www.dristeem.com 106277.1443@compuserve.com For the most current product information, visit our Web site: www.dristeem.com DRI-STEEM Corporation An ISO 9001:2000 certified corporation European office: Marc Briers Grote Hellekensstraat 54 b B-3520 Zonhoven Belgium +3211823595 (voice) +3211817948 (fax) E-mail: marc.briers@dristeem.com U.S. Headquarters: 14949 Technology Drive Eden Prairie, MN 55344 800-328-4447 or 952-949-2415 952-229-3200 (fax) E-mail: sales@dristeem.com Continuous product improvement is a policy of DRI-STEEM Corporation; therefore, product features and specifications are subject to change without notice. DRI-STEEM, GTS, Rapid-sorb, Ultra-sorb, and Vapor-logic are registered trademarks of DRI-STEEM Corporation and are filed for trademark registration in Canada and the European community. Modbus is a registered trademark of Schneider Electric. BACnet is a registered trademark of ASHRAE. LonTalk is a registered trademark of Echelon Corporation. 2010 DRI-STEEM Corporation Ultra-sorb Double header design Shortest non-wetting distance; install within inches of upstream dampers, coils, or elbows without dripping Steam capacity up to 840 kg/h Factory assembled for easy installation High-efficiency tube option Rapid-sorb Single header design Short non-wetting distance Steam capacity up to 360 kg/h Assembled on-site High-efficiency tube option High-efficiency tube option Up to 85% reduction in wasted energy, airstream heat gain, and condensate production PVDF insulation is plenum-approved for in-duct installation Will not absorb water or support microbial growth; has a closed-cell structure Your DRI-STEEM distributor is: Ultra-sorb panel with high-efficiency tubes Form No. GTS-PDS-M-0210 Rev Web