SPP Notification to Construct



Similar documents
Project Screening Results

139 FERC 61,088 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION ORDER GRANTING MARKET-BASED RATE AUTHORIZATION AND REQUEST FOR WAIVERS

AGREEMENT FOR PRELIMINARY ENGINEERING DESIGN MISO PROJECT J233

EPCOR Distribution & Transmission Inc.

SUBJECT: Marcy-South Series Compensation Project Capital Expenditure Authorization Request and Contract Award

Midwest Reliability Organization Procedure For NERC PRC-012

Substations or Switching Stations

LCMC Management Response to EY Review of Muskrat Falls Project Cost, Schedule and Related Risk April Report

Green Power Connection Net Energy Metering Engineering Review Process in Delaware and Speeding Up the Application Fee Process

PUC DOCKET NO DIRECT TESTIMONY AND EXHIBITS RALPH G. GOODLET, JR. ON BEHALF OF SHARYLAND UTILITIES, L.P. May 31, 2013

Generation and Transmission Interconnection Process

COLORADO SPRINGS UTILITIES ATTACHMENT K TO OPEN ACCESS TRANSMISSION TARIFF

1 March Al Dussinger Embrace Home Loans 25 Enterprise Center Middletown, RI Dear Mr. Dussinger,

All routes and route segments included in this notice are available for selection and approval by the Public Utility Commission of Texas.

U.S. COMMODITY FUTURES TRADING COMMISSION

STATE OF FLORIDA MITIGATION BANK IRREVOCABLE LETTER OF CREDIT TO DEMONSTRATE CONSTRUCTION AND IMPLEMENTATION FINANCIAL ASSURANCE

Fiber Winds Renewable Energy Project. Over $87 Million in U.S. Government Subsidies

145 FERC 61,237 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION

Smart energy, clean energy, today s energy. The. Mariah. wind power project

TO: Freddie Mac Servicers January 24,

FSPBA8 SQA Unit Code H5FA 04 Process the transfer of foreign currency

TERMS AND CONDITIONS

Title 20 PUBLIC SERVICE COMMISSION. Subtitle 50 SERVICE SUPPLIED BY ELECTRIC COMPANIES. Chapter 02 Engineering

Risk Management GUIDE GUIDE. for PHYSICIAN. Austin, TX

Generation Interconnection System Impact Study Report. For. PJM Generation Interconnection Request Queue Position X1-114.

Procedures for Opt Out and Removal of Taxpayers from IRS FBAR Voluntary Disclosure Program

BUSINESS ASSOCIATE AGREEMENT BETWEEN AND COMMISSION ON ACCREDITATION, AMERICAN PSYCHOLOGICAL ASSOCIATION

REGULATORY ACCOUNTING GUIDELINES FOR TRINIDAD AND TOBAGO ELECTRICITY COMMISSION DRAFT FOR CONSULTATION

Safety Share Who is Cleco? CIP-005-3, R5 How What

To learn more about Berkshire Hathaway Energy s commitment, please visit their website.

Project Tracking and Cost Estimation Tool Member Impacting Project Overview

-1- PSEG-LI Update of LIPA SGIP Full Docw-NYISO reqmts above 10 MW

RESPONSE OF THE OFFICE OF CHIEF COUNSEL DIVISION OF INVESTMENT MANAGEMENT

Memorandum. This memorandum requires Board action. Executive Summary

Top Ten Compliance Issues for Implementing the NERC CIP Reliability Standard

135 FERC 61,058 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION

MAR Sincerely,

Transmission Planning Study (Year 2022) for Cherokee 4 Replacement Alternatives. Final Report

2015 I n t e g r a t e d T r a n s m i s s i o n P l a n Y e a r A s s e s s m e n t R e p o r t

Q140 Cluster Addendum

Transmission Function Employees Job Titles and Descriptions 18 C.F.R 358.7(f)(1)

Step-by-Step 401(k) Plan Administration Transfer

East Penn School District Lehigh County, Pennsylvania

QUANTA ENERGIZED SERVICES

The Institute of Professional Practice, Inc. Business Associate Agreement

Eldorado-Ivanpah Transmission Project WELCOME To Southern California Edison Company s Eldorado-Ivanpah Transmission Project OPEN HOUSE

Salt River Project Ten Year Plan Projects

INDEPENDENT SYSTEM OPERATORS (VI + Access Rules vs. ISO vs. ITSO)

March 14, Subject: Southern California Edison 2014 Annual Progress Report

Tufts Consulting Group: Macedonian Energy

Emergency Support Function #14 Long Term Community Recovery and Mitigation

REQUESTS FOR PROPOSAL (RFP) FOR UTILITY RATE CONSULTING SERVICES FOR THE CITY OF FORT MORGAN

Generator Interconnection and Deliverability Study Methodology Technical Paper

Transmission Leadership. Teresa Mogensen Vice President, Transmission

Conservation Voltage Reduction (CVR)

Re: Preliminary Permit Application for the Rose Creek Pumped Storage Project

AUG Mr. Max Jameson Environmental/Regulatory Manager Sabco Oil and Gas Corporation 34 S. Wynden Drive Houston, TX Dear Mr.

Modeling of PV Based Distributed Generator Systems with Diverse Load Patterns

BETTA open letter on likely late issuance of offers under standard licence condition C18 of the electricity transmission licence

Actual capital expenditure during the current regulatory period. Project summary

Oklahoma State University Policy and Procedures. Red Flags Rules and Identity Theft Prevention

FINAL. Alternative Evaluation. for the. Proposed Burlington-Wray 230-kilovolt Transmission Project

ESB Networks Response. ERGEG Consultation. Voltage Quality Regulation in Europe

Notice to Proceed (NTP) Request #13 to Construct the Section kilovolt (kv) Overhead Transmission Line

Public Utilities - Proposed Cost Effectiveness Programs For 2012

Transcription:

SPP-NTC-200365 SPP Notification to Construct January 12, 2016 Mr. John Fulton Southwestern Public Service Company P.O. Box 1261 Amarillo, TX 79105 RE: Notification to Construct for Transmission Service Request resulting from Aggregate Transmission Service Study SPP-2014-AG1-AFS-6 Dear Mr. Fulton, Pursuant to Section 3.3 of the Southwest Power Pool, Inc. ("SPP") Membership Agreement and Attachments O and Y of the SPP Open Access Transmission Tariff ("OATT"), SPP provides this Notification to Construct ("NTC") directing Southwestern Public Service Company ("SPS"), as the Designated Transmission Owner, to construct the Network Upgrades. On June 29, 2015, SPP concluded that the project(s) is required on the SPS system to fulfill Transmission Service Requests as detailed in Aggregate Facility Study SPP-2014-AG1-AFS-6. On December 18, 2015, SPP received all executed Transmission Service Agreements from the customers associated with SPP-2014-AG1-AFS-6. New Network Upgrades Project ID: 30708 Project Name: Line - Ochoa - Ponderosa Tap 115 kv Ckt 1 Rebuild Need Date for Project: 6/1/2018 Estimated In-Service Date: 6/1/2018 Estimated Cost for Project: $4,161,825 Network Upgrade ID: 50954 Network Upgrade Name: Ochoa - Ponderosa Tap 115 kv Ckt 1 Rebuild Network Upgrade Description: Rebuild 9.1-mile 115 kv line from Ochoa to Ponderosa Tap. 1

emergency rating of 178 MVA. Estimated Cost for Network Upgrade (current day dollars): $4,161,825 SPP-NTC-200365 Project ID: 30918 Project Name: Line - Byrd Tap - Cooper Ranch - Oil Center - Lea Road 115 kv Ckt 1 Rebuild Need Date for Project: 6/1/2021 Estimated In-Service Date: 6/1/2021 Estimated Cost for Project: $8,446,740 Network Upgrade ID: 51272 Network Upgrade Name: Cooper Ranch - Oil Center 115 kv Ckt 1 Rebuild Network Upgrade Description: Rebuild 3.5-mile 115 kv line from Cooper Ranch to Oil Center. emergency rating of 163 MVA. Estimated Cost for Network Upgrade (current day dollars): $2,597,868 Network Upgrade ID: 51273 Network Upgrade Name: Byrd Tap - Cooper Ranch 115 kv Ckt 1 Rebuild Network Upgrade Description: Rebuild 4.9-mile 115 kv line from Byrd Tap to Cooper Ranch. emergency rating of 166 MVA. Estimated Cost for Network Upgrade (current day dollars): $3,566,564 2

3 SPP-NTC-200365 Network Upgrade ID: 51407 Network Upgrade Name: Lea Road - Oil Center 115 kv Ckt 1 Rebuild Network Upgrade Description: Rebuild 3.1-mile 115 kv line from Lea Road to Oil Center. emergency rating of 162 MVA. Estimated Cost for Network Upgrade (current day dollars): $2,282,308 Project ID: 30987 Project Name: Line - Cunningham - Monument Tap 115 kv Ckt 1 Rebuild Need Date for Project: 6/1/2021 Estimated In-Service Date: 6/1/2021 Estimated Cost for Project: $4,770,097 Network Upgrade ID: 51406 Network Upgrade Name: Cunningham - Monument Tap 115 kv Ckt 1 Rebuild Network Upgrade Description: Rebuild 6.5-mile 115 kv line from Cunningham to Monument Tap. emergency rating of 184 MVA. Estimated Cost for Network Upgrade (current day dollars): $4,770,097 Project ID: 30989 Project Name: Sub - Potash Junction 230 kv Terminal Upgrade Need Date for Project: 6/1/2018 Estimated In-Service Date: 6/1/2018 Estimated Cost for Project: $63,251 Network Upgrade ID: 51409 Network Upgrade Name: Potash Junction 230 kv Terminal Upgrade

4 SPP-NTC-200365 Network Upgrade Description: Replace wavetrap at Potash Junction 230 kv substation. Network Upgrade Specification: All elements must have at least an emergency rating of 372 MVA. Estimated Cost for Network Upgrade (current day dollars): $63,251 Project ID: 30990 Project Name: Line - Jal - Teague 115 kv Ckt 1 Rebuild Need Date for Project: 6/1/2021 Estimated In-Service Date: 6/1/2021 Estimated Cost for Project: $7,544,091 Network Upgrade ID: 51410 Network Upgrade Name: Jal - Teague 115 kv Ckt 1 Rebuild Network Upgrade Description: Rebuild 10.3-mile 115 kv line from Jal to Teague. emergency rating of 140 MVA. Estimated Cost for Network Upgrade (current day dollars): $7,544,091 Project ID: 30991 Project Name: Line - National Enrichment Plant - Teague 115 kv Ckt 1 Rebuild Need Date for Project: 6/1/2018 Estimated In-Service Date: 6/1/2018 Estimated Cost for Project: $4,990,255 Network Upgrade ID: 51411 Network Upgrade Name: National Enrichment Plant - Teague 115 kv Ckt 1 Rebuild Network Upgrade Description: Rebuild 6.8-mile 115 kv line from National Enrichment Plant to Teague.

SPP-NTC-200365 emergency rating of 147 MVA. Estimated Cost for Network Upgrade (current day dollars): $4,990,255 Commitment to Construct Please provide to SPP a written commitment to construct the Network Upgrade(s) within 90 days of the date of this Notification to Construct, in addition to providing a construction schedule and an updated ±20% cost estimate, NTC Project Estimate, in the Standardized Cost Estimate Reporting Template for the Network Upgrade(s). Failure to provide a written commitment to construct as required by the SPP OATT could result in the Network Upgrade(s) being assigned to another entity. Mitigation Plan The Estimated In-Service Date represents the timing required for the Network Upgrade(s) to address the identified need. Your prompt attention is required for formulation and approval of any necessary mitigation plans for the Network Upgrade(s) included in the Network Upgrades(s) if the Estimated In-Service Date is not feasible. Additionally, if it is anticipated that the completion of any Network Upgrade will be delayed past the Estimated In-Service Date, SPP requires a mitigation plan be filed within 60 days of determination of expected delays. Notification of Commercial Operation Please submit a notification of commercial operation for each listed Network Upgrade to SPP as soon as the Network Upgrade is complete and in-service. Please provide SPP with the actual costs of these Network Upgrades as soon as possible after completion of construction. This will facilitate the timely billing by SPP based on actual costs. Notification of Progress On an ongoing basis, please keep SPP advised of any inability on SPS's part to complete the approved Network Upgrade(s). For project tracking, SPP requires SPS to submit status updates of the Network Upgrade(s) quarterly in conjunction with the SPP Board of Directors meetings. However, SPS shall also advise SPP of any inability to comply with the Project(s) Schedule as the inability becomes apparent. All terms and conditions of the SPP OATT and the SPP Membership Agreement shall apply to this project(s) and nothing in this letter shall carry such terms and conditions. 5

SPP-NTC-200365 Don't hesitate to contact me if you have questions or comments about these requests. Thank you for the important role that you play in maintaining the reliability of our electric grid. Sincerely, Lanny Nickell Vice President, Engineering Phone: (501) 614-3232 Fax: (501) 482-2022 lnickell@spp.org cc: Carl Monroe - SPP Antoine Lucas - SPP William Grant - SPS 6