Limits to Audible Alarm Signal Recognition when Encoding Alarm Context April, 2015



Similar documents
Evolution of an Integrated System for Alarm and Call Management March 19, 2014

This document describes how engineered sounds for control system alarms improve Operator responsiveness.

Clinical Alarms Improvement Initiative

Safety Innovations FOUNDATIONHTSI. Using Data to Drive Alarm System Improvement Efforts. The Johns Hopkins Hospital Experience

Alarms and human behaviour: implications for medical alarms

AUDIBLE MONITOR ALARM: FRIEND OR FOE?

Safety and General Information

The Growing Concern Surrounding Medical Alarm Fatigue

The Growing Concern Surrounding Medical Alarm Fatigue

Sound the Alarm: Alarm System Management for Patient Safety

ANNEX 11. RESOLUTION MSC.128(75) (adopted on 20 May 2002) PERFORMANCE STANDARDS FOR A BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS)

Wireless Emergency Alerts (WEA) / Emergency Alert System (EAS) Survey Comparison

Overview of International Medical Device Human Factors Standards. Ed Israelski PhD, Director of Human Factors Abbott Abbott Park, IL, USA

Accessibility-MiVoice-Business.docx Page 1

Pulse Oximetry Alarm Reduction Strategy at Boston Medical Center

Australian/New Zealand Standard

WD-AMX Water Detection Controllers

Palomar Health: Ready Set RUN Configuration of Actionable Alerts Ben Kanter MD FCCP, CMIO Jennifer Sloane, RN, BSN, MBA, PMP

ACOUSTICAL CONSIDERATIONS FOR EFFECTIVE EMERGENCY ALARM SYSTEMS IN AN INDUSTRIAL SETTING

How To Identify The Most Important Alarm Signals To Manage: A Holistic Approach

Summary Table Voluntary Product Accessibility Template. Not Applicable- Not a web-based application. Supports. Not Applicable

Why Do We Need Weather Radios?

Auditory Alert Characteristics: A Survey of Pilot Views

Summary Table Voluntary Product Accessibility Template

The design and use of auditory alarms in medical

AARC-EVAC Portable Hand Held or Fixed Transmitter with SOS assist - ATX43E25 SAFETY ALERT SYSTEMS

Optimizing Masimo SET SpO2 Alarm Settings on Select GE Monitors

Bringing Order Out of Chaos

Nucleus Fitting Software 1.2. User Guide

HQBN USMC HENDERSON HALL Telephone System Call Pilot Voice Messaging

IEC Algorithmic Alert Tone Demo

Alarm fatigue in the perception of medical soundscapes!

Summary Table Voluntary Product Accessibility Template. Criteria Supporting Features Remarks and explanations

Alarm management: The Abbott Northwestern Experience A quality improvement project

Before the FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C ) ) ) ) ) ) ) ) ) ) ) ) ) COMMENTS OF THE TELECOMMUNICATIONS INDUSTRY ASSOCIATION

TAXONOMY OF TELECOM TERMS

Automatic Telephone Dialer TD-101(W)

Notification Solutions Campus

15- EMERGENCY BUTTON ACTIVATION

ETSI ETR 187 TECHNICAL April 1995 REPORT

Wireless Mobile speaker

Regulatory expectations on user engagement for medical devices

Definitions for KRS , , , and As used in KRS , , , and : (1) "Ancillary services"

Ultrasound Condition Monitoring

SPEECH Biswajeet Sarangi, B.Sc.(Audiology & speech Language pathology)

Guide: Technologies for people who are Deaf or hard of hearing

Summary Table Voluntary Product Accessibility Template

Section 314: TELECOMMUNICATION AND RELATED SERVICES SOURCING RULE A. Except for the defined telecommunication services in subsection (C), the sale of

Programming Guide. Model: R-1630C

Addressing Alarm Fatigue. Todd Hazzard CBET October 2014

Space Weather Forecasts for Civil Aviation & Spaceflight. Bill Murtagh NOAA Space Environment Center Boulder, Colorado

Early Evaluation Center

This section will focus on basic operation of the interface including pan/tilt, video, audio, etc.

Description of system

Summary Table Voluntary Product Accessibility Template

DCN Next Generation The next step in digital congress management

VPAT 1 Product: Call Center Hearing Aid Compatible (HAC) Headsets Operated with Amplifier Models M12, MX10, P10, or SQD:

Software-based medical devices from defibrillators

Summary Table Voluntary Product Accessibility Template

Connected Vehicles as things on the Internet. big data, the cloud, and advanced automotive research

Lecture 2, Human cognition

The application of real-time distraction monitoring to driver safety systems. Matthew R. Smith Gerald J. Witt Debi L. Bakowski

The Audiology and Vocational Rehabilitation partnership

Information and Communication Technology in Health Care To Infinity and Beyond. Pam Bush, RN, BScN

PTE Academic Tutorial

Easy call handling Combines telephone directories from various sources Determines employees current location

SW012. Installation software for the Right Ventricular Lead Integrity Alert feature. Reference Manual

Perceptual influence of the vibratory component on the audio component of alarms produced by rumble strips, by measuring reaction times

Tele MODELS LP and DTMF

The FDA Perspective on Human Factors in Medical Device Software Development

LOW COST WIRELESS EMERGENCY ALERT SOLUTIONS

Emergency Dialer DIAL-ALERT MODEL: AD

Fundamental Components of Hearing Aid Fitting for Infants. Josephine Marriage PhD

AUDIO POINTER V2 JOYSTICK & CAMERA IN MATLAB

VPAT for Apple MacBook Pro (Late 2013)

K9 Heat Alarm Owners Manual HA-1520

Dr. Abdel Aziz Hussein Lecturer of Physiology Mansoura Faculty of Medicine

Innovative Systems CVAA Compliance Statement

Summary Table Voluntary Product Accessibility Template

Usability of Medical Applications Ved Line Kagenow Svenstrup,

MONITOR ALARM FATIGUE: STANDARDIZING USE OF PHYSIOLOGICAL MONITORS AND DECREASING NUISANCE ALARMS. Critical Care Management. 1.

Musical Literacy. Clarifying Objectives. Musical Response

Experts in wireless device and infrastructure test solutions

Dial91 App for Windows Phone 8 Edition User Guide

Transcription:

Limits to Audible Alarm Signal Recognition when Encoding Alarm Context April, 2015 Peter Doyle, Sharon Allan, Shawn Sullivan, Adam Sapirstein and Maria Cvach pdoyle6@jhmi.edu

Audio Alarm Signals and Context Encoded a good degree of context in 17 different audio alarm signals 2 yrs. later assessed their discriminability Sources for the 17 signals included: Nurse call system Physiologic monitoring system Not vents or pumps Wireless phones Pagers 2

Discrimination Test Participants 25 CVSICU RNs, 3 levels experience No screening for hearing ability/loss Protocol One session recognition testing with 3 trials, each presenting17 tones randomly.wav files via headphones Each signal balanced for volume Each signal presented for 10 sec Responses recorded as correct/incorrect 3

Results: Recognition Accuracy Patient normal (Nurse call) 100% Voice call (WiFi phone) 100% Crisis (Monitor) 84% Code blue (Nurse call) 67% Code blue/lav emerg, etc. (WiFi phone) 67% Equipment disconnects/text msg (WiFi phone) 67% System warning (Monitor) 67% Advisory (Monitor) 65% Lav assist (Nurse call) 63% 4

Results Continued Crisis (Pager) 60% Non-crisis (Pager) 59% Warning (Monitor) 48% Equipment/vent alarm (Nurse call) 21% System advisory (Monitor) 15% Staff and Lav emerg (Nurse call) 13% Staff normal/equip disconnect (Nurse call) 3% Staff & Pt normal/lav assist (WiFi phone) 0% 5

Military-Standard-1472 Discriminable differences in intensity, pitch, beats and harmonics shall be provided. Audio warning signals should normally consist of two elements: and alerting signal and an identifying or action signal If absolute discrimination is required, the number of signals to be identified shall not exceed four 2 Not sustained 6

IEC 60601-1-8 Alarms should: Help determine urgency Locate the room/patient Determine or categorize the cause of the alarm condition Determine or categorize the nature of response or awareness required 7

ANSI/AAMI HE75:2009(R)2013 The goals that any alarm signal should meet include: Clearly communicate the appropriate degree of urgency Clearly identify the relevant location Clearly identify the reason for the alarm condition 8

Research Points Out People can only differentiate, learn, and/or remember a few different abstract auditory alarm signals (Stanton and Edworthy, 1999; Patterson, 1982). Medical professionals appear to be poor at correctly identifying auditory alarm signals in their environments. (Momtahan et al.,1993). Fewer than 30% of [non-anesthetist] participants could identify [16 melodic alarms designed per IEC Annex F with] 100% accuracy after practice. (Sanderson et.al.2006) 9

Summary of The Standards Discriminable differences shall be provided Absolute audible signals shall not exceed four Audible signals should help determine Urgency Location Categorize cause/reason for alarm condition Response required 10

What Now? Physiologists and clinicians decide on alarms levels and thresholds HF and engineers can assist with best use of technology within manufacturers constraints Reduce the number of signals/tones Ideally 3 tiers: Run / Walk / Shuffle Encode only the highest priority audible alarms with alarm-specific content Use other media (visual or voice) to convey context other than urgency 11

Tone Reduction Plan Reduce WiFi phone signals from 4 to 2 tiers of priority (eliminates 2 signal) Transfer physiologic monitor pager alarms to existing WiFi phone signals (eliminates 2 signal) Combine lav assist call with patient normal call (eliminates 1 signal) Disable the hall monitor crisis signals Retest 12

AAMI Alarm Foundation Efforts AAMI alarm standards committee recognizes the challenges AAMI supporting Judy Edworthy to develop 7-10 signals Those to be evaluated by an international work group International alarm committee to adopt a set of signals 13

References 1. ANSI/AAMI HE75: 2009, Human Factors Engineering- Design of Medical Devices 2. IEC 60601-1-8 General requirements, tests and guidance for alarm systems in medical electrical equipment and medical electrical systems 3. Military Standard 1472G, Department of Defense Design Criteria Standard, Human Engineering, 11 Jan. 2012. 4. Momtahan K, Hetu R, and Tansley B. Audibility and identification of auditory alarms in the operating room and intensive care unit. Ergonomics, 36:1159 1176, 1993. 5. Patterson RD. Guidelines for auditory warning systems on civil aircraft. Paper 82017. In: Civil Aviation Authority. London (U.K.): Civil Aviation Authority, 1982. 6. Sanderson et. al. (Anaesthesia, 2006, 61, pages 142-147) 7. Stanton N, and Edworthy J. Auditory warnings and displays: an overview. In: Stanton NA, and Edworthy J (Eds.).Human factors in auditory warnings. Brookfield (VT): Ashgate Publishing, 1999, pp. 3 33. 14