FRM301 SNMP Upgrade Procedure



Similar documents
USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks

Ethernet Interface Manual Thermal / Label Printer. Rev Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

FMUX04 SNMP Tutorial

Quick Installation Guide Network Management Card

Update Firmware from GUI

[HOW TO RECOVER AN INFINITI/EVOLUTION MODEM IDX ] 1

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

Liebert IntelliSlot Web Cards

Updating MNS-BB CUSTOMER SUPPORT INFORMATION PK012906

User Manual Network Interface

Connecting the DG-102S VoIP Gateway to your network

SNMP-1 Configuration Guide

Ultra Thin Client TC-401 TC-402. Users s Guide

Firmware upgrade instructions for the Web/SNMP and Network

3.1 Connecting to a Router and Basic Configuration

Dominion KX II-101-V2

SecureLinx Spider Duo Quick Start Guide

50-Port 10/100/1000Mbps with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide

Prestige 324. Prestige 324. Intelligent Broadband Sharing Gateway. Version 3.60 January 2003 Quick Start Guide

3.5 EXTERNAL NETWORK HDD. User s Manual

QUICK START GUIDE Cisco M380 and Cisco M680 Content Security Management Appliance

QNAP SYSTEMS INC. QNAP Digital Signage Player Web Console Manual

TFTP Firmware upgrade

Debugging Network Communications. 1 Check the Network Cabling

Cisco S380 and Cisco S680 Web Security Appliance

LevelOne VOI H.323 VoIP Gatekeeper. User Manual

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

MAX T1/E1. Quick Start Guide. VoIP Gateway. Version 1.0

Broadband Router ESG-103. User s Guide

How to Log On Main Screen Control Console Menus How to Log On Summary Page Navigation Menu... 29

Prestige 324 Quick Start Guide. Prestige 324. Intelligent Broadband Sharing Gateway. Version V3.61(JF.0) May 2004 Quick Start Guide

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T PIN6 T PIN7 R+ PIN8 R-

Lab 2 - Basic Router Configuration

Deploying Windows Streaming Media Servers NLB Cluster and metasan

H0/H2/H4 -ECOM100 DHCP & HTML Configuration. H0/H2/H4--ECOM100 DHCP Disabling DHCP and Assigning a Static IP Address Using HTML Configuration

Moxa Device Manager 2.0 User s Guide

GV-Data Capture V3 Series User's Manual

QUICK START GUIDE. Cisco C170 Security Appliance

Network Management Card

PRILINK PRI Management System

TL-PS310U Single USB 2.0 Port MFP and Storage Server

Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)

ezvsp User's Manual ( Version 2.1d ) Sollae Systems Co., Ltd.

Ethernet Module Manual

Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005

Chapter 3 Management. Remote Management

Securely manage data center and network equipment from anywhere in the world.

Industrial L2+ Managed Gigabit/ 10 Gigabit Ethernet Switch. IGS-5225 Series. Quick Installation Guide

1 INTRODUCTION. This document describes the procedure to upgrade LTMR.

How Do I Recover infiniti Remotes and Line Cards?

QUICK START GUIDE. Cisco S170 Web Security Appliance. Web Security Appliance

PIM31 Remote Setup and Operational Procedures

Schneider OS-Loader usage via Ethernet or USB.

TE100-P21/TEW-P21G Windows 7 Installation Instruction

IP SERIAL DEVICE SERVER

Using a simple crossover RJ45 cable, you can directly connect your Dexter to any computer.

Prestige 314 Read Me First

SMC7004ABR Barricade Broadband Router Installation Instructions

Connecting and Setting Up Your Laptop Computer

Maintaining the Content Server

Configuring the Switch with the CLI Setup Program

PBX DIGITAL TELEPHONE EXCHANGE MAINTENANCE GUIDE

MAGPOWR Spyder Firmware Update Instruction Manual

SNMP Upgrade Procedure for NV Transmitters

Centurion C4 Transfer Guide using C4 File Transfer Utility

Title Page Web/SNMP Management SmartSlot Card

TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

Chapter 4 Management. Viewing the Activity Log

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

SATO Network Interface Card Configuration Instructions

Quick Start Guide. Cisco Small Business. 200E Series Advanced Smart Switches

External Storage 200 Series. User s Manual

Prestige 650R-31/33 Read Me First

CMP-102U. Quick Installation Guide

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

Focal Point 2.1 Management Software & CPSMM100 Firmware Manual

Network Management Card. User Manual

Device Installer User Guide

CS 326e F2002 Lab 1. Basic Network Setup & Ethereal Time: 2 hrs

Prestige 202H Plus. Quick Start Guide. ISDN Internet Access Router. Version /2004

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

DSA-1000 / PRT-1000 Device Server / Thermal Printer

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version Rev.

64-Bit Compatibility with Micromeritics Applications

Application Note: Upgrading Interceptor software with FTP server on local PC

Setting up Digi Connect Wi-SP or Digi ConnectPort TS W Devices On a Secured Wireless Network for use with Veriteq viewlinc

User s Manual Network Management Card

USER S GUIDE Switched Rack PDU

AXIS 205 Network Camera Quick Installation Guide

T3 Mux M13 Multiplexer

Allworx Installation Course

your Gateway Windows network installationguide b wireless series Router model WBR-100 Configuring Installing

Networking Alpha signs on a TCP/IP network

PC/POLL SYSTEMS Version 7 Polling SPS2000 Cash Register TCP/IP Communications

StarMOBILE Network Configuration Guide. A guide to configuring your StarMOBILE system for networking

SOP085 - HELLER OVEN SOFTWARE INSTALLATION PROCEDURE. For version 6.2.x.x

ZyXEL AES-100 V2.03(AS.0) Release Notes/Manual Supplement

Transcription:

The information within this document is intended for experienced service personnel with knowledge of TCP/IP networking, PC networking configuration, serial terminal configuration and operation. Failure to follow steps precisely could leave the flash on the embedded device in an unusable state, requiring factory assistance. Failure of boot code upgrade requires the factory to physically replace the flash chip, which is a surface mounted component, soldered with RoHS compliant materials (non-lead). Please be warned and please be careful. Stable AC power is a MUST!! during flash update Document Version 5.02 Jan. 28, 2010 f/w ver. 5.02

Prerequisites: FRM301 3U Chassis with SNMP, Hardware version 3.1G (This is actually the third hardware release version of SNMP for FRM301) Identified by CPU chip Winbond (Nuvoton) W90P710CDG (Not for Samsung ARM processor!!!!) DB9F to DB9M 1:1 cable Notebook or PC with available COM port and TCP/IP ready Console emulation software (PuTTY, HyperTerminal or Tera Term) TFTP server (CTCU TFTP Server for Windows) Upgrade firmware, for version 5.02, released as 'romfs502.gz' file which is Unix GZIPped image files (DO NOT UNZIP this file.) Procedure: 1. Connect the SNMP's DB9F serial port to the desktop's or laptop's COM port with 1:1 configuration cable. 2. Start the terminal application and configure it for: a. 38.4k baud (exception: version 5.01 release used 115.2k baud) b. 8 pits c. no parity d. 1 stop bit e. no flow control 3. Connect the SNMP's RJ-45 Ethernet port to the desktop's or Laptop's Ethernet LAN port. Configure TCP/IP settings on the PC as follows: a. static IP 192.168.0.145 b. subnet mask 255.255.255.0 c. gateway 192.168.0.254 4. Start the TFTP application program by double-clicking. It was extracted with the upgrade package. If the firewall complains, select 'Unblock'. Make sure all 'gz' and 'bin' files are located in the same directory as the TFTP application program. 2

Online Upgrade Procedure 5. FileSystem Upgrade: Reboot the SNMP and allow it to completely boot. Upgrade may also be performed on an online system, adjust the IP settings of TFTP server and image names without changing SNMP IP address. For this version 5.02 upgrade, kernel does not require update. *** V5.01-17 *** Main Menu and Rack Status: 1:Slot #1 >> 10/100 Base << 9:Slot #09 >> 1000 Base << 2:Slot #2 >> 10/100 Base << A:Slot #10 >> SERIAL << 3:Slot #3 >> 10/100 Base << B:Slot #11 >> SERIAL << 4:Slot #4 >> 10/100 Base << C:Slot #12 >> E1 BNC << 5:Slot #5 >> 1000 Base << D:Slot #13 >> 10/100 Base << 6:Slot #6 >> 1000 Base << E:Slot #14 >> V.35 HS << 7:Slot #7 >> 1000DS << F:Slot #15 >> V.35 << 8:Slot #8 >> 1000 Base << G:Slot #16 >> V.35 << '1' to '9', 'A' to 'G': I/O Cards Setting 'P': Show Fans and Powers Status 'R': Refresh Status 'ESC' Logout 'M': Manager Configuration Setup 'S': System Configuration and TFTP Setup Console:[On line] Telnet:[Off line] GUI:[Off line] The above screen indicates the SNMP firmware version is 5.01 and that the CPU controller card is version 2.17 ( -17 ). The controller card cannot be upgraded via software, only by chip change. 6. Key in the 'S' command to enter the System Configuration and TFTP Setup. *** V5.01-17 *** System Configuration and TFTP Setup Menu: MAC Address : 0002abddeef5 1:IP Address : 192.168.0.219 2:Subnet Mask : 255.255.255.0 3:Gateway IP : 192.168.0.254 4:TFTP Server IP : 192.168.0.145 5:TFTP Download Kernel : linux.zip 6:TFTP Download File System : romfs.zip '1' to '6': Configure Setting 'R': Reset All Setting to Default 'S': Store Setting and Reboot 'K': TFTP and Upgrade the SNMP Kernel 'F': TFTP and Upgrade the SNMP File System 'ESC': Main Menu. 7. If required, change the settings to match these below, or set for your network environment. (1) IP Address: 192.168.0.219 (2) Subnet Mask: 255.255.255.0 (3) Gateway IP: 192.168.0.254 (4) TFTP Server IP: 192.168.0.145 (5) TFTP Download Kernel: linux.zip (6) TFTP Download File System: romfs502.gz (S) to write the changes and reboot. Be sure to reboot the SNMP after any of these system changes. (online traffic WILL be effected when SNMP is rebooted) 3

8. Open a command window on the laptop or desktop PC and ping the SNMP. Make sure the network connection works and is reliable. 9. On the laptop or PC, if the TFTP application is not already running, start it now by double clicking the server icon. Note: A Linux box on the network can also act as a TFTP server if configured properly. You can even upload the files to your TFTP server and then perform upgrade from Telnet of FRM301- SNMP remotely. (It is necessary to disable the built-in firewall in Windows temporarily to perform the upgrade process.) Some anti-virus programs also include firewall. Make sure all firewalls are disabled or unblocked for the TFTP server. 4

10. On the laptop or PC, in the terminal screen and while in the SNMP System Configuration Setup, press the 'F' key to do File System upgrade. Answer with y 'ESC': Main Menu Do TFTP and Flash File System function. Are you sure?['y' or 'n']y Start TFTP and Flash. Please Wait... Dots are added during flashing DO NOT POWER OFF!!!!! *** V5.01-17 *** System Configuration and TFTP Setup Menu: MAC Address : 0002abddeef5 1:IP Address : 192.168.0.219 2:Subnet Mask : 255.255.255.0 3:Gateway IP : 192.168.0.254 4:TFTP Server IP : 192.168.0.145 5:TFTP Download Kernel : linux.zip 6:TFTP Download File System : romfs502.gz '1' to '6': Configure Setting 'R': Reset All Setting to Default 'S': Store Setting and Reboot 'K': TFTP and Upgrade the SNMP Kernel 'F': TFTP and Upgrade the SNMP File System 'ESC': Main Menu 11. After the flash is written, the SNMP will automatically reboot. Make sure to change the baud rate of the console terminal to 38.4K when upgrading from 5.01 to 5.02. (38.4K is the original baud rate for previous version SNMP. Returning it to 38.4k from 115.2k keeps previous documentation for FRM301 accurate.) *** V5.02-17 *** Main Menu and Rack Status: 1:Slot #1 >> 10/100 Base << 9:Slot #09 >> 1000 Base << 2:Slot #2 >> 10/100 Base << A:Slot #10 >> SERIAL << 3:Slot #3 >> 10/100 Base << B:Slot #11 >> SERIAL << 4:Slot #4 >> 10/100 Base << C:Slot #12 >> E1 BNC << 5:Slot #5 >> 1000 Base << D:Slot #13 >> 10/100 Base << 6:Slot #6 >> 1000 Base << E:Slot #14 >> V.35 HS << 7:Slot #7 >> 1000DS << F:Slot #15 >> V.35 << 8:Slot #8 >> 1000 Base << G:Slot #16 >> V.35 << '1' to '9', 'A' to 'G': I/O Cards Setting 'P': Show Fans and Powers Status 'R': Refresh Status 'ESC' Logout 'M': Manager Configuration Setup 'S': System Configuration and TFTP Setup Console:[On line] Telnet:[Off line] GUI:[Off line] Reflects the new version before reboot 5

12. Confirm TFTP transfer was OK and then close the TFTP server application. (should indicate the new version file system file) This completes the successful upgrade of the FRM301 SNMP. View the 'release_note.txt' file in this package for changes in this version. <END> 6

Fiber Series CTC Union Technologies Co., Ltd. Far Eastern Vienna Technologies Center (Neihu Technology Park) 8F, No. 60, Zhouzi St., Neihu, Taipei, Taiwan Phone:(886) 2.2659.1021 Fax:(886) 2.2.799.1355 E-mail: techsupport@ctcu.com http://www.ctcu.com