FPD IN-LINE SPECTRAL TESTING SOLUTIONS
PRI ENGINEERS COMBINE 70 YEARS OF SCIENTIFIC GRADE ACCURACY WITH SPEED It is well known that spectrally based measurements offer the highest degree of accuracy available for determining intensity (luminance) and color (chromaticity) of FPD s regardless of the technology CCFL, LED Backlit LCD or OLED etc. One major drawback to existing spectral solutions is unacceptably long measurement times. The Photo Research series of A-TAKT spectroradiometers has eliminated this by making it possible to perform in-line production testing with spectral accuracy at or near real-time speeds. Three models of A-TAKT are available the V-7HS, V-7WD and V-6AQL. The V-7HS is our most sensitive and fastest offering, measuring 0.5 cd/m² at 250 ms total measurement time (tested for LED backlit LCD s). Comparable spectroradiometers can take almost 14 seconds to perform the same task. The V-7WD provides high-speed solutions for those applications, such as LCD BLU s, where higher intensity devices need testing. Finally, the V-6AQL offers the ultimate cost effective solution for less speed critical applications such as AQL, IQC or OQC testing. All three versions feature a built in CCD target acquisition camera removing the necessity of sighting through an eyepiece while providing an image of the measured area to your testing documentation. RS232 and USB interfaces are provided, and the enclosures are ruggedized to withstand potentially harsh environments. The instruments are easily fixtured utilizing the integral dual ¼-20 SAE threaded mounting holes. Objective lenses range from a fixed focus 50mm to a variable focused 75mm lens. Customized lenses are available for your unique production line application. To remove unwanted light from the measurement, a special luminance accessory with ambient light shield is available. The A-TAKT series of instruments are controlled via SDK and are Windows Vista 32 or 64 bit (or higher) or OSX (10.7+). FLEXIBLE CUSTOMIZATION Because production test environments differ (from target distance and measurment area to system controller interface) A-TAKT can be configured to address individual requirements, including custom lenses (to suit any working distance/ spot size requirements) and an easy to program SDK for smooth, effortless integration into your ATE. To insure that A-TAKT consistently returns accurate and repeatable measurement results, we ve included EasyProfile, an automated method of teaching the A-TAKT DUT characteristics. Profiled data is then used to deliver the fastest measurement times with scientific grade accuracy and precision.
THE HIGH SPEED, HIGH RESOLUTION SPECTRAL SOLUTION FOR HIGH INTENSITY APPLICATIONS Thermo Electrically Cooled Detector Targeting USB Camera (1280 x 720) Obejective Lens (Tailored to your application) A-TAKT V-7HS Two ¼ - 20 mounting holes Test the maximum number of samples in the minimum amount of time without compromising accuracy or repeatability. q Full grayscale, gamma and color in mere seconds. (depending on luminance levels and number of patterns measured) q Spectroradiometric accuracy and repeatability at near real-time speeds. q Thermally cooled detector for stability in production environments. q Measure ultra-low black levels in milliseconds. q DUT measurement target area customizable for your specific application. USB / RS-232 A-TAKT V-7HS SENSITIVITY CHART 1, 2 APERTURE LENS SPECTRAL BANDWIDTH 1.5 1.25 1 0.5 FF-50 or MS-75 2 NM (FWHM) 0.00069-416 0.001-600 0.0016-937 0.0065-3,748 FF-50 or MS-75 5 NM (FWHM) 0.00029-166 0.0004-240 0.00062-375 0.0026 1,500 FF-50 or MS-75 8 NM (FWHM) 0.000174-104 0.00025-150 0.00039-234 0.0163 936 1 ALL VALUES ARE IN CD/M 2. 2 MEASURING A WHITE LED.
THE HIGH SPEED, HIGH RESOLUTION SPECTRAL SOLUTION FOR HIGH INTENSITY APPLICATIONS Thermo Electrically Cooled Detector Targeting USB Camera (1280 x 720) Objective Lens (Tailored to your application) A-TAKT V-7WD Two ¼ - 20 mounting holes The V-7WD is optimized for the testing of high intensity sources such as FPD BLU s with extreme accuracy and repeatability. q Spectroradiometric accuracy and repeatability at near real-time colorimeter speeds. q Thermally cooled detector for stability in production environments. q High speed, high spectral resolution measurements of ultra-bright BLU s, LEDS, etc.. q DUT measurement target area customizable for your specific application. USB / RS-232 A-TAKT V-7WD SENSITIVITY CHART 1, 2 APERTURE LENS SPECTRAL BANDWIDTH 1.5 1.25 1 FF-50 or MS-75 2 NM (FWHM) 0.00014-41667 0.002-60,000 0.0045-135,000 FF-50 or MS-75 5 NM (FWHM) 0.00056-16667 0.0008-24000 0.0018-54,000 FF-50 or MS-75 8 NM (FWHM) 0.00035-10,417 0.00050-15000 0.0011-33,750 1 ALL VALUES ARE IN CD/M 2. 2 MEASURING A WHITE LED.
ECONOMICAL, COMPACT SOLUTION FOR QC/QA APPLICATIONS. Compact Industrialized Packaging USB / RS-232 Objective Lens (Tailored to your application) Two ¼ - 20 mounting holes Targeting USB Camera (1280 x 720) A-TAKT V-6AQL Economical, compact solution for QC/QA applications. When your AQL application requires a spectral solution for the utmost accuracy, look to the 6AQL as THE solution. q Compact industrial ready package. q Spectroradiometric design guarantees accuracy and repeatability to meet or exceed your production needs. q DUT measurement target area customizable for your specific application. A-TAKT V-6AQL SENSITIVITY CHART 1, 2 APERTURE LENS SPECTRAL BANDWIDTH 1.5 0.5 FF-50 or MS-75 8 NM (FWHM) 0.600-80,000 2.40-320,000 1 ALL VALUES ARE IN CD/M 2. 2 MEASURING A WHITE LED.
A-TAKT CONTROL SOFTWARE A-TAKT SDK MAKES IT CONVENIENT TO INTEGRATE CONTROL OF THE A-TAKT SERIES INTO YOUR SPECIFIC PRODUCTION LINE ENVIRONMENT BY INCLUDING AN EASY TO USE SDK AS STANDARD EQUIPMENT. q Compatibility with Windows Vista, Windows 7, Windows 8 32 or 64 bit or MAC OS X 10.7+. q EasyProfile function that optimizes the A-TAKT system to the DUT insuring the fastest and most accurate results. q Access to targeting camera image. q Complete instrument control setup, measurement and data collection. q Custom software solutions can be developed to insure the smoothest transition of the A-TAKT component into your production line environment. Call us with your requirements. A-TAKT 7-VHS LENS CHART 1, 2 APERTURE OBJECT LENS SPOT SIZE 3 1.5 1.25 1 0.5 3 5.0 299.1 299.1 5.5 316.9 316.9 6.0 335.2 335.2 FF-50 6.5 353.5 353.5 7.0 371.9 371.9 7.5 299.0 335.2 390.3 390.3 8.0 310.4 350.1 396.3 396.3 8.5 328 364.4 DISTANCE 5.0 451.1 451.1 MS-75 7.5 450.9 505.3 588.0 588.0 8.0 469.0 526.9 615.6 615.6 8.5 487.0 549.1 643.9 643.9 1 ALL DIMENSIONS ARE IN MILLIMETERS. 2 DISTANCES ARE FROM THE FRONT MOUNTING HOLE (SEE ENVELOPE DRAWING). 3 FOR THE 0.5 APERTURE, DIVIDE SPOT SIZES BY 2.0.
4.59 [116.66] (3.24 [82.36]) 3.44 [87.44] 7.39 [187.78] 5.93 [150.50] 6.69 [169.80] (.04 [1.02]) 10.61 [269.49].48 [12.19] 4.30 [109.22] 4X.50 [12.70] RUBBER FOOT V-7HS V-7WD 2X.72 [18.22] (3.44 [87.44]) 2X 1/4-20 UNC - 2B.55 [12.70] 2X 5.25 [133.35] (.08 [2.03]) OVERHANG (.08 [2.03]) OVERHANG 2.57 [65.28] 2X.48 [12.19] 2X 9.29 [235.97] (3.24 [82.36]) 3.44 [87.44] 3.13 [79.38] 6.69 [169.80] (.06 [1.60]) 7.57 [192.28] 4X.50 [12.70] RUBBER FOOT.48 [12.19] 4.30 [109.22] 2X.72 [18.22] V-6AQL (3.44 [87.44]) 2X 1/4-20 UNC - 2B.55 [12.70] 2X 5.25 [133.35] (.08 [2.03]) OVERHANG (.08 [2.03]) OVERHANG 2.57 [65.28] 2X.58 [14.73] 2X 6.25 [158.75]
A-TAKT SPECIFICATIONS V-7HS V-7WD V-6AQL DETECTORS 512 512 128 COOLED DETECTOR YES YES NO STANDARD APERTURE 1.25 2.0 1.0 OBJECTIVE LENSES Fixed Focus 50mm Variable Focus 75mm Custom (contact factory) STANDARD BANDWIDTH 2 nm (see page 3 for further sensitivity details) 8 nm (see page 4 for further sensitivity details) 8 nm (see page 5 for further sensitivity details) LUMINANCE RANGE IN cd/m² FOR WHITE LED 0.001 TO 600 0.002 TO 60,000 0.6 TO 80,000 TOTAL CYCLE TIME FOR WHITE LED 250 ms @ 0.5 cd/m² 60 ms @ 10,000 cd/m² 70 ms @ 10,000 cd/m² TOTAL CYCLE TIME FOR ILLUMINANT A 450 ms @ 0.5 cd/m² 75 ms @ 10,000 cd/m² 86 ms @ 10,000 cd/m² LUMINANCE ACCURACY FOR ILLUMINANT A ± 2% @ 0.005 cd/m² ± 2% @ 0.01 cd/m² ± 2% @ 0.5 cd/m² LUMINANCE RANGE IN cd/m² FOR ILLUMINANT A 0.0005 TO 2,900.001 TO 30,000 0.3 TO 40,000 SIZE IN INCHES (MM) L X W X H 10.79 X 6.69 X 7.40 (270 X 170 X 188) 10.79 X 6.69 X 7.40 (270 X 170 X 188) 10.63 X 6.69 X 4.61 (192 X 170 X 117) WEIGHT IN LBS. (KG) 9.55 (4.33) 9.55 (4.33) 4.72 (2.14) INC. The Reference in Color and Light Measurement 9731 Topanga Canyon Place Chatsworth, CA 91311-4135 Tel: (818) 725-9750 Fax: (818) 725-9770 sales.pr@photoresearch.com www.photoresearch.com Copyright 2013 Photo Research, Inc. All rights reserved. Specifications are subject to change without notice.