Primacord detonating cords



Similar documents
The Shelf Life Of Static Ropes For Life Rescue Lines

Tracking No: Page 1 of 23

Super Slider ADJUSTABLE FROM Model #HD26229

BroadBand PowerShield. User Manual

verope AG St. Antons-Gasse 4a CH-6300 Zug / Switzerland Tel: +41 (0) Fax: +41 (0) Your requirements are our focus.

Fibre Optic Indoor/Outdoor Cable

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249

Flexible cables for submersible products

Hazardous Substance Class Definitions & Labels

A Guide to the Transportation of Dangerous Goods Regulations

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

RAUFOSS EXPLOSIVE COMPRESSION FITTINGS

3 Scotch-Seal TM. Tamper Proof Sealant Technical Data Issue No. 5

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

aseries A13B Mini Bullet Camera User Manual

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

Crystal Clear Sealant

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

Guide on the Segregation, Packaging, Labelling and Storage of Laboratory Chemical Wastes for Schools

Getting the best from your urn

Queen's University Environmental Health and Safety

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Explosives Safety Initial Training. Course # 5.01 Rev TO

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

KINGSTON, FRONTENAC AND LENNOX & ADDINGTON PUBLIC HEALTH BY-LAW, POLICY & PROCEDURE MANUAL PROCEDURE: PERSONNEL. DATE: PAGE: 1 of 5

Pet hair clipper. Model Diagrams within this manual may not be drawn proportionally.

Start Here Series. All-in-One Printer. Print Copy Scan. Includes Information on the: ESP 3250 All-in-One Printer ESP 3260 All-in-One Printer

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Hard Disk Drive (HDD)

HIH-4000 Series Humidity Sensors

Battery Tester. GxT Incorporated, Cheboygan MI, U.S.A. All Rights Reserved E040-01G. 40 & 42HD Operator s Manual

COMPLETE MANUAL. Version: Optic. September 2015 (English), version 1.0. EnergyOT Optic Developed and Manufactured by Genoa Spark, lda Made in Portugal

Grand Mesa Plus LAMINATE - WIRE BRUSHED. GAGVGM81012A Prairie. GAGVGM80012NA Colorado. GAGVGM84012A Pecan Rustic. GAGVGM85012A Saddle Walnut

Battery Charger. Instruction Manual G

Technical Data Sheet February 2014

Cable Preparation and Pulling Procedure Best Practices for Fiber Optic Indoor Tight-Buffered Cable

KALPANA INDUSTRIES LTD. TECHNICAL DATA SHEET

Scotch-Weld PUR Easy 250 Adhesive Applicator

Fibre optic cables MDIC LSZH

Double Coated Urethane Foam Tapes

Compressed Gas Cylinder Storage and Handling Guide

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

Transportation of Soils Contaminated with Flammable Liquids

Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, Product Description

3 Scotch-Weld TM. Urethane Adhesives 3532 B/A 3535 B/A 3549 B/A. Technical Data January, 2010

3M Wire Connectors. Reliable, high performing solutions for every wire connecting application. 3Innovation

Decree of the Ministry of the Environment on fire safety of ventilation systems

OAK WORKBENCH WITH 2 DRAWERS

Extrusion Flo-Valve INSTRUCTIONS-PARTS LIST psi (210 bar) Maximum Working Pressure. Model , Series K. Rev.

Ride-on Car OWNER S MANUAL KT1151TG. Keep instructions for future reference

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

Document Library TS Data Sheet

MATERIAL SAFETY DATA SHEET

3 Destructible Vinyl Label Material 7613T / 7930T

3 Laser Toner Printable Polyester Label Material 7840TL

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

How To Safely Dig For Natural Gas

Hazardous Substances and New Organisms Act 1996

SITE SPECIFIC FALL PROTECTION PLAN

Installation Instructions for Fletco Carpets

3M HEAD PROTECTION. For more information, please visit HARD HATS 101 MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Leak Detection System

)454, !,5-).)5- #!",% 3(%!4(3 #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43. )454 Recommendation,

Dehumidifier Users manual. For Models: DH45S DH65S

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

3 Scotch-Weld TM. Urethane Adhesives 3532 B/A 3535 B/A 3549 B/A. Technical Data March, 2002

CamSplice Assembly Manual

Blast management plan template

3 Thermal Transfer Acrylate Label Material 3921

REVISION NO : 3 August 2010

CARRIAGE OF GAS CYLINDERS BY ROAD IN CARS, VANS AND OTHER VEHICLES GUIDANCE FOR DRIVERS AT WORK

RayClic Connection System Installation Instructions

User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes

Transport and Mailing Systems

Hot Water Urns. all models. Helpline. v3.0

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Flygt flexible cables

XONYX Solid Surface Owner's Manual

BiO-STiX Drain Cleaner & Deodorizer

Company and Product Presentation

GeniSys 12V. Model Description / Applications. Advanced 12 Vdc Burner Control

RayClic Connection System Installation Instructions

Material Safety Data Sheet

Part I - Installation

Waste Management Policy

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.

Meaco 30L and Meaco 40L dehumidifier instruction manual

Guide To Returning Your Satellite Modem and Radio Assembly Model: HN7000S

Ducoterra Radiant Heating Panel Installation Manual

SIGMACOVER 300. PRODUCT DATA SHEET December 12, 2014 (Revision of November 1, 2013) DESCRIPTION

Columbia flooring will resist fading from exposure to sunlight or artificial light.

Crimp Tooling Where Form Meets Function

Factory owners must ensure the boiler is:

Installing the Broadband Global Area Network (BGAN) Fixed Mount Kit

Guidelines for the Safe Transport of Infectious Substances and Diagnostic Specimens

Ultrasonic Jewelry/DVD Cleaner. make jewelry, dvds and more sparkle like new

Transcription:

Primacord detonating cords ZapcordTM 40 (40g/m) ZapcordTM 10 (10g/m) Detacord (15g/m) E-cord (5g/m) SB cordtm (8g/m) function Primacord detonating cord, when detonated, has the initiating energy of a blasting cap at all points along its entire length. The Primacord detonating cord detonates at a speed of approximately 7000m/s. Primacord trunklines will initiate any number of additional lengths, extensions or branch lines through correctly tied connections or knots. When used as a down line, the explosive supplier should be consulted as to the sensitivity and compatibility of cord and explosives used. description Primacord detonating cord is simple in design and use. The high explosive core is encased in various protective coverings developed to withstand the many conditions encountered in the fi eld. The difference between the standard types of Primacord detonating cord is essentially the core load coupled with a difference in the degree of protection afforded by the encasements. Various combinations of materials such as textiles and plastics cover the raw PETN (Pentaerythritol Tetranitrate) core. The textiles used provide tensile strength and fl exibility, as well as resistance to abrasion and cutting, extremes of heat and cold and water and oil penetration.

advantages safety reliability quality All products are brightly coloured for easy identification in storage and in the field. All explosives are classified as dangerous goods and can cause personal injury if not handled correctly. Primacord detonating cords will still initiate through knots, kinks and water. It has excellent abrasive resistance properties. Primacord detonating cords are factory manufactured to order under stringent quality control to adhere to specifications. product information & applications Detacord Detacord detonating cord will detonate through standard knots and will initiate other detonating cords. Most cap sensitive explosives, detonating relays and cast boosters are insufficiently sensitive to be initiated by Detacord. Confirmation of compatibility should be obtained from the manufacturer. Detacord detonating cord is flexible, easy to handle, readily ties and holds knots. Detacord is commonly used for surface, quarrying, construction or underground blasting applications. Detacord can also be used as surface trunklines or lead-in-lines when used in conjunction with shock tube Primadet accessories. E-cord E-cord is flexible and easy to handle which readily ties and holds knots. E-cord detonating cord is commonly used as a surface trunkline, lead-in-line and down line. E-cord detonating cord will detonate through standard knots and will initiate other detonating cords. E-cord is not recommended for underground use or applications. In all applications, some cast boosters can not be reliably initiated by E-cord detonating cord. The manufacturer of the booster should be consulted before using E-cord detonating cord in this manner. SB cord TM SB cord TM is designed for secondary blasting. SB cord TM does not exhibit the tensile and abrasive resistant properties of the other Primacord detonating cords due to the exclusion of the outer layers of protective yarns and wax. SB cord TM is compatible with all cap sensitive products and can be used with detonating relays. SB cord TM detonating cord will detonate through standard knots and will initiate other detonating cords. SB cord TM is not recommended for underground use or applications. Zapcord Zapcord detonating cord possesses all the handling and reliability advantages of the other Primacord detonating cords. Zapcord is recommended to be used as trunklines and downlines in severe surface or underground blasting applications. It is most commonly used as a downline where continuity throughout the column is to be ensured. Zapcord 40 Zapcord 40 detonating cord possesses all the handling and reliability advantages of the other Primacord detonating cords. It is recommended for use as downlines in severe blasting applications. It is most commonly used for demolition work, trim blasting, pre-splitting and landmine clearance. 2

Detacord E-cord SB cord TM Zapcord TM Zapcord TM 40 Core load (g/m) 3.5 5.0 8.0 10.0 40.0 Tensile strength (kg) 100 100 70 130 130 Outside diameter (mm) 3.6 4.0 4.2 4.7 7.6 Temperature range ( C) Water resistance Yes Yes -10 to 80 Limited Yes Yes important instructions Always store detonators and explosives separately. Keep detonating cord away from sparks, flames or any other source of ignition. Store explosives according to the country rules & regulations. Always knot the end of the cord, to avoid water ingress (figure one). Always keep loose ends as short as possible (figure two). All Primacord detonating cord connections should be pulled tight so that the two lines make positive contact. The clove hitch is recommended for connecting downlines to trunklines or branch lines. It is also very important that all branch line connections are kept at right angles (figure three). Make sure that all Primacord detonating cord lines are devoid of loops and kinks and prevent lines crossing over each other (figure four). Only a sharp knife should be used to cut cord and never use a scissor-type cutting device. With underground or small applications, it is recommended to ring-feed to avoid possible misfires (figure five). Avoid any acute angles (figure six). Initiation of the Primacord detonating cord may be done using an Instantaneous Electric Detonator (IED) (figures seven & eight). Figure one Figure two Figure three 3

Figure four Figure five Figure six Figure seven Figure eight packaging information Standard product lengths and packaging densities are available on your request. Please contact your representative. standard packaging Primacord detonating cord. Detacord E-cord SB cord TM Zapcord TM Zapcord TM 40 Core load (g) 3.5 5.0 8.0 10.0 40.0 Carton dimensions (mm) 295 x 295 x 385 length spools ship length spools ship length spools ship length spools ship length spools ship per /box weight per /box weight per /box weight per /box weight per /box weight spool (kg) spool (kg) spool (kg) spool (kg) spool (kg) (m) (m) (m) (m) (m) 500 2 13.1 300 2 9.0 250 2 8.4 250 2 11.4 50 2 6.3 150 4 8.6 150 4 9.4 150 4 10.3 100 4 9.7 100 4 6.2 100 4 6.7 100 4 7.3 50 4 5.5 80 4 5.2 50 4 4.0 80 4 6.1 50 4 3.7 50 4 4.3 4

colour codes & labelling Detacord E-cord SB cord TM Zapcord Zapcord 40 Yellow with one Pink with one Orange Yellow with two black Yellow with two black countering black countering yarn countering yarns black countering yarn yarns Each carton is marked with a printed sticker that identifies the product according to core load, date of manufacture, batch number and carton number. The information enables Sasol Dyno Nobel to refer to quality records in order to investigate customer complaints. recommended storage, shelf life & transport Primacord Recommended storage 3 months (dry, well ventilated) Shelf life 24 months Transport: UN classification 1.1D UN number 0065 Zax number 362 warning and disclaimer All products and equipment manufactured and supplied by Sasol Dyno Nobel shall be used, handled, stored or transported according to the guidelines laid down by the relevant applicable legislation in that country. Explosive accessories should be secured in an explosive magazine. All or any part of the explosive accessories is dangerous and can cause injury or death. If you find any of these items, do not touch them. Instead, immediately report their location and description to the police. To the extent provided for in terms of section 61 of the Consumer Protection Act, 2008, Sasol Dyno Nobel shall not be liable for any damage, whatever its nature, including incidental, consequential and indirect damage caused to buyers or third parties, directly or indirectly arising from or relating to the supply, use or storage of the products and equipment arising after delivery unless caused by Sasol Dyno Nobel s wilful misconduct or gross negligence. *Trademarks are registered or applied marks are licensed to Sasol. 5 Sasol Dyno Nobel (A division of Sasol Chemical Industries Limited 1968/01/391/06) 15 Baker street Rosebank 2196 PO Box 5486 Johannesburg 2000, South Africa +27 (0) 11 441 3111 www.sasol.com