DESIGN AND SETUP OF A HYBRID SOLAR SEAWATER DESALINATION SYSTEM: THE AQUASOL PROJECT



Similar documents
ALONE. small scale solar cooling device Project No TREN FP7EN Project No TREN/FP7EN/ ALONE. small scale solar cooling device

Economic and technical assessment of desalination technologies

DE-TOP User s Manual. Version 2.0 Beta

Differentiation Summary. Revolutionizing Water Clean-Up Opportunities

VGB Congress Power Plants 2001 Brussels October 10 to 12, Solar Power Photovoltaics or Solar Thermal Power Plants?

DESIGN CHALLENGES AND OPERATIONAL EXPERIENCE OF A MEGA MED SEAWATER DESALINATION PLANT IN TIANJIN

Vicot Solar Air Conditioning. V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: Fax:

The soot and scale problems

HEAT PUMPS A KEY COMPONENT IN LOW CARBON FUTURE

Performance Test of Solar Assisted Solid Desiccant Dryer

MICRO-COGENERATION AND DESALINATION USING ROTARY STEAM ENGINE (RSE) TECHNOLOGY

UNIT 2 REFRIGERATION CYCLE

Transient Analysis of Integrated Shiraz Hybrid Solar Thermal Power Plant Iman Niknia 1, Mahmood Yaghoubi 1, 2

Recover Heat from Boiler Blowdown Water

Solar Thermal Systems

The Grand Miramare Hotel Santa Margherita (Portofino) Italy March 19 22, Inspiring Innovation and Excellence

Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

Solare termico altre applicazioni. G.V. Fracastoro

EuroSun 1998 A NEW CONCEPT FOR SOLAR THERMAL DESALINATION Results of In-Situ Measurements

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

ALFEA HYBRID DUO GAZ. New Model 2011

Executive summary. - It has a favorable geographical location with significant direct solar irradiation.

Performance Evaluation of a Heat Pump System for Simultaneous Heating and Cooling

SOLAR WATER PURIFICATION WITH THE HELP OF CSP TECHNOLOGY

8. Heat pumps, heat pipes, cold thermal energy storage

Solar Thermal Energy Storage Technologies

Carnegie Mellon University School of Architecture, Department of Mechanical Engineering Center for Building Performance and Diagnostics

Waste Heat Recovery through Air Conditioning System

HYBRID WAY EAF OFF GAS HEAT RECOVERY -ECORECS- MASANARI YAMAZAKI*1, YASUHIRO SATO*2, RYUTARO SEKI*3

Thermal Coupling Of Cooling and Heating Systems

Work package no. 7: Water and Power co-generation in the Mediterranean islands and coastal areas

Natural geothermal energy.

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district

Abstract. s: phone: , fax:

Glossary of Heating, Ventilation and Air Conditioning Terms

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

PERFORMANCE OPTIMIZATION OF HYBRID SOLAR HEATING SYSTEM USING THERMOELECTRIC GENERATOR

SOLAR THERMAL POWER PLANTS FOR HYDROGEN PRODUCTION

Final design of an advanced solar dryer for salt recovery from brine effluent of an MED desalination plant

How To Calculate The Performance Of A Refrigerator And Heat Pump

General Presentation

Field test of a novel combined solar thermal and heat pump system with an ice store

1 DESCRIPTION OF THE APPLIANCE

Sustainable water heating solutions through solar systems

Increasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas

Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications

VACUUM REFRIGERATION SYSTEMS

GLOBACON 05 HVAC Systems for Cogen

NEW JERSEY CENTER OF EXCELLENCE

ENERGY SAVING WORT BOILING SISTEM IN BREWING FACTORY

Solar Thermal TECHNOLOGY. Eric Buchanan Renewable Energy Scientist West Central Research and Outreach Center Wcroc.cfans.umn.edu

New absorption chillers for high efficient solar cooling systems

SONNENKLIMA package solution description

ECOCIAT. Domestic hot water heat recovery unit

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Energy savings in commercial refrigeration. Low pressure control

Feasibility Study of Brackish Water Desalination in the Egyptian Deserts and Rural Regions Using PV Systems

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

PERFORMANCE EVALUATION OF WATER-FLOW WINDOW GLAZING

Session 2: Hot Water Supply

ARP Food Industry, Portugal

Energy Recovery Systems for the Efficient Cooling of Data Centers using Absorption Chillers and Renewable Energy Resources

Evaluation Of Hybrid Air- Cooled Flash/Binary Power Cycle

The Power of Concentrating Solar

Small-Scale Solar Heating and Cooling Systems

Gas Absorption Heat Pumps. Future proofing your heating and hot water

Chapter 3.4: HVAC & Refrigeration System

TERMOSOLAR BORGES: A THERMOSOLAR HYBRID PLANT WITH BIOMASS

LG Electronics AE Company, Commercial Air Conditioning

HYBRID SOLAR - BIOMASS PLANTS FOR POWER GENERATION; TECHNICAL AND ECONOMIC ASSESSMENT

ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric energy and heat -

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Presentation Outline. Background

Cooking at the Speed of light!

GAS HEATING IN COMMERCIAL PREMISES

Exploitation Tests of Borehole Heat Exchangers in the Laboratory of Renewable Energy Sources in Miekinia Poland

Hybrid heat pumps. saving energy and reducing carbon emissions

Abstract Process Economics Program Report 136A PLANT UTILITIES COSTS (January 1995)

Automobile Air Conditioning Primer

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

ALUMINUM. BestPractices Assessment Case Study. Alcoa North American Extrusions Implements Energy Use Assessments at Multiple Facilities.

Engineering and Construction for Sustainability Solar Concentration Workshop World Bank November 5th, 2008

INTERSTAGE ENERGY RECOVERY TURBINE APPLICATION MARCO ISLAND, FLORIDA

Building Energy Systems. - HVAC: Heating, Distribution -

How To Power A Power Plant With Waste Heat

Testing and Performance of the Convex Lens Concentrating Solar Power Panel Prototype

A Novel Storage Technology Opens New Opportunities for CSP

Desuperheater Online Program Sizing Guidance

Vitocaldens 222-F Compact Gas-Hybrid appliance

Solar SOLARMAX ELECTRIC BOOSTED SPECIFICATIONS ALL AUSSIE GAS & ELECTRIC BOOSTED SOLAR WATER HEATERS

16. Heat Pipes in Electronics Cooling (2)

Test Report No. C1319LPEN

Your Partner for Concentrated Solar Power Generation The Heart of Your Process

R ENEWABLE SOURCES CSP. Sustainable and cost-efficient solar thermal energy

SOLAR-POWERED COOLING, DEHUMIDIFICATION AND AIR CONDITIONING

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

Half the cost Half the carbon

Design Approach, Experience and Results of 1MW Solar Thermal Power Plant

Transcription:

DESIGN AND SETUP OF A HYBRID SOLAR SEAWATER DESALINATION SYSTEM: THE AQUASOL PROJECT Diego Alarcón Julián Blanco Sixto Malato M. Ignacio Maldonado Pilar Fernández CIEMAT - Plataforma Solar de Almería Ctra. de Senés s/n Tabernas, Almería 04200 diego.alarcon@psa.es ABSTRACT Despite the energy efficiency advances reached during the last decade, seawater desalination continues to be an intensive fossil energy consumer. In the current global framework, with growing oil price instability and the environmental requirements derived from compliance with the Kyoto Protocol, the sustainability of this technological solution inevitably passes through continued improvement of energy efficiency of the physical processes involved, as well as the use of renewable energy resources, such as for example, solar energy. In 2002, the R&D European Project AQUASOL was initiated at the Plataforma Solar de Almería for the purpose of improving the existing solar thermal seawater desalination technology based on the multi-effect distillation process. After the conclusion of the research phase, a completely new desalination system has been designed and its implementation has been initiated for testing during the demonstration phase. This paper describes the final design of the overall system, and all the erection work performed. 1. INTRODUCTION Seawater desalination is one of the possible solutions to the severe water shortage problem our planet is experiencing during the first half of this century [1], a problem that is not exclusive to developing countries, as the appearance of seasonal episodes of persistent drought in certain regions of the so-called developed countries is becoming more and more frequent. The latest world inventory of desalination facilities established a historical accumulated production capacity (installed or contracted) of 37.75 million cubic meters per day, of which around 26.50 million cubic meters per day are currently in operation [2]. Insofar as desalination processes are concerned, basically only two technologies are implemented on a commercial scale, membrane processes (reverse osmosis, electrodialysis) and thermal distillation processes (multi-stage flash distillation, multi-effect distillation, mechanical vapor compression). The sphere of application of the first is both in brackish water and seawater, while the second are only economically feasible if employed in desalting seawater. In reality, only two processes, reverse osmosis (RO) and multi-stage flash distillation (MSF) take up 80% of the market, one or the other leading this classification depending on the salt concentration of the product water. If only seawater desalination is considered, then the MSF process takes up 47.2% of the global production capacity compared to 36.5% for RO. However, if both desalination of brackish water and seawater are considered, then osmosis processes constitute 47.2% of the worldwide production capacity compared to 36.5% for multi-stage flash distillation. Retrospectively, a decade ago these proportions were 32.7% and 51.3%, respectively, which clearly indicates the current market tendencies of the two technologies. If the progress of the energy efficiency of the two technologies in the last three decades is considered, thermal distillation systems, which in the last thirty years have hardly undergone any appreciable reduction in the desalination process energy requirement, are found to have stagnated. In fact, today, thermal distillation of seawater can only compete economically in large seawater-electricity cogeneration plant layouts, with the additional requirement of relatively low-cost fossil fuel, such as in the Persian Gulf. However, in the case of seawater desalination with reverse osmosis, consumption has gone from 30.84 kwh/m 3 (1970) to a consumption of 3.5 kwh/m 3 (2000), that is, the energy

efficiency has multiplied by nine. Moreover, there are realistic perspectives of these values diminishing even further, as illustrated by the ADC project, now underway in the United States, which intends to demonstrate that that a consumption of 1.7 kwh/m 3 can be achieved in reverse osmosis seawater desalination [3]. Nevertheless, in spite of all these improvements, the seawater desalination process continues to be an intensive fossil energy consumer. In the current global framework, with growing oil price instability and the environmental requirements derived from compliance with the Kyoto Protocol, the sustainability of this technological solution inevitably passes through continued improvement of energy efficiency of the physical processes involved, as well as the use of renewable energy resources, such as for example, solar energy. In 1988, the Solar Thermal Desalination (STD) Project was initiated at the facilities of the Plataforma Solar de Almería (PSA) in the south of Spain [4]. This research project lasted until 1994 and had two main objectives: i) to study the technical and financial feasibility of seawater desalination with solar thermal energy, ii) to optimize the solar thermal desalination system implemented by introducing and evaluating improvements minimizing electrical and thermal energy consumption. The solar technology initially proposed was based on the use of parabolic-trough solar concentrators with single-axis tracking working with thermal oil as the heat transfer and thermal storage fluid, for the purpose of supplying the energy required for a multieffect (MED) distillation plant installed at the PSA. With this configuration, a performance ratio (kg of distillate per 2,326 kj heat input) of was obtained. With the goal of improving that value, two procedures for recovering heat in the MED unit were studied, thermal compression (which is usually used in conventional MED plants) and absorption heat pump technology, which upgrades low temperature heat with much higher second law efficiency than ejector compressors [5]. A first-world prototype of double-effect absorption (LiBr-H 2 O) heat pump (DEAHP) for desalination applications was built and installed in the PSA MED plant in order to recover the latent heat of the steam produced in the last effect. This configuration increased the performance ratio to 20. Although the technical feasibility of the system was demonstrated, its economics remained far from those of conventional desalination technologies. Since 1994, this desalination system has been providing the distilled water required by all the experimental facilities located at the PSA, accumulating a large number of operating hours and demonstrating the robustness of the technology proposed, as no major failure has occurred during this period. Research activities in solar desalination at the PSA were recently boosted by the startup in 2002 of a new combined (research & demonstration) project called Enhanced Zero Discharge Seawater Desalination using Hybrid Solar Technology (AQUASOL, FP5-EVK1-CT2001-002) partially supported by the European Commission under the Energy, Environment and Sustainable Development Programme. The main objective of this project is the development of a seawater desalination technology based on multi-effect distillation that is energy efficient, low-cost and has a zero discharge. In August 2004, the AQUASOL Project research phase was successfully concluded and all the subsystems have been designed and implemented for their evaluation during the demonstration phase. This paper describes the final design of the overall system, and all erection work performed. 2. DESCRIPTION OF THE AQUASOL SYSTEM The seawater system designed under the AQUASOL Project is made up of: A multi-effect distillation plant with 14 cells in a vertical arrangement. A stationary CPC (Compound Parabolic Concentrator) solar collector field. A thermal storage system based on water. A double effect (LiBr-H 2 O) absorption heat pump. A smoke-tube gas boiler. An advanced solar dryer for final treatment of the brine. These subsystems are interconnected as shown in Fig. 1. The system operates with water as the heat transfer fluid, which is heated as it circulates through the solar collectors. The solar energy is thus converted into thermal energy in the form of the sensible heat of the water, and is then stored in the tanks. Hot water from the storage system provides the MED plant with the required thermal energy. In absence of solar radiation, the gas boiler feeds the absorption heat pump, which is also fed with low temperature steam from the last MED plant effect, in order to heat the water coming from first effect from 63.3ºC up to 66.5ºC. 2.1 The distillation unit The PSA SOL-14 desalination plant is a forward-feed multieffect distillation unit manufactured and delivered by Weir ENTROPIE in 1987 (See Table 1 for specifications). It has 14 cells, or effects, in a vertical arrangement, in which seawater is preheated on its way towards the first cell of the plant, which is at the top of the desalination tower.

TABLE 1: TECHNICAL SPECIFICATIONS OF THE SOL-14 DESALINATION PLANT Feedwater flow 8 m 3 /h Brine reject 5 m 3 /h Distillate production 3 m 3 /h Seawater flow at condenser: at ºC: at 25ºC: 8 m 3 /h 20 m 3 /h Output salinity 50 ppm TDS Number of cells 14 Heat source energy consumption 190 kw Performance Ratio >9 Vacuum system Top brine temperature 70ºC Condenser temperature 35ºC Hydroejectors (seawater at 3 bar) The original first cell that worked with low-pressure saturated steam (70ºC, 0.31 bar), has been replaced in the AQUASOL Project by a new one, working with the hot water coming directly from the thermal storage tank (See Table 2). A new horizontal tube bundle, front and rear water boxes and a new spraying tray with technical characteristics constrained to the dimensions of the first cell, have also been installed in the SOL-14 plant. TABLE 2: ESTIMATED PERFORMANCE OF THE NEW PSA MED PLANT FIRST EFFECT 2.2 The solar field Desalination driven by solar collectors Desalination driven by absorption heat pump Power 200 kw 150 kw Inlet /Outlet hot 75.0 / 71.0 ºC 66.5 / 63.5 ºC water temperature Brine temperature 68ºC 62.0 ºC (on first cell) Hot water flow rate.0 kg/s.0 kg/s Pressure drop 0.4 bar g 0.4 bar g The solar field is made up of 252 stationary solar collectors (CPC Ao Sol 1.x) with a total surface area of approximately 500 m 2 arranged in four rows of 63 collectors (See Fig. 2). Due to the specially designed hydraulic layout (reverse feeding mode), total flow rate (14.97 m 3 /h) is equally distributed into the four rows (3.74 m 3 /h) without further regulation. The collectors are organized in groups of nine, all connected in parallel in each row, which in turn are connected in parallel to each other, feeding into the thermal storage system. Each group of nine collectors is organized in the following way: i) the collectors are oriented east-west to Fig. 1: Final configuration proposed for AQUASOL seawater desalination system

Fig. 2.: 500 m 2 stationary CPC solar collector field maximize energy collection; ii) each group is subdivided into three subgroups of three collectors; iii) in each subgroup, the collectors are connected in parallel; iv) each subgroup is connected to the next in series (See Fig. 3). higher temperatures than could be reached with the 1.x CPC collector. 2.3 Thermal storage system The thermal storage system is made up of two interconnected -m 3 -capacity water tanks (See Fig. 4). The total volume finally chosen is based on the response time required by the gas boiler and the absorption heat pump to reach nominal operating conditions. The use of two tanks enables the solar contribution to be increased over the year as well as obtain certain temperature stratification necessary to avoid the heat pump water inlet temperature exceeding the permissible range (60ºC 70ºC). Fig. 3: Detail of connection between solar collectors in the AQUASOL solar field TABLE 3: TECHNICAL CHARACTERISTICS OF AO SOL CPC 1.X COLLECTOR Dimensions 20 x 18 x 7 mm Aperture area 1.98 m 2 Absorber (selective coating) Emissivity Absorptivity 0. 0.15 0.94 0.95 Weight (empty) 38 kg Operating pressure 6 bar Testing pressure bar Optical efficiency 0.70 0.71 Thermal loss factor 3.4 W/m 2 K A transparent honeycomb-type insulation material inside the solar collector was considered during the research phase. However, at the operating temperatures that are expected in the system (below 80ºC) there is no net advantage in this. Furthermore, stagnation temperatures reached without the honeycomb are much safer in case of pump failure. The use of a new higher concentrating CPC collector prototype (1.5x) was considered, but was finally rejected because it would have meant a reduction in the number of hours operating with solar energy, and there was no need for The tanks are A6 grade B carbon steel that had to be treated to prevent corrosion on the surfaces in contact with hot water. After studying several options, paint treatment resistant to water up to 150ºC was finally chosen (See Table 4).. TABLE 4: TANK INNER SURFACE PAINT TREATMENT Preparation Sandblasting SA-2 Metal primer Zinc silicate 75 μm Intermediate layer Two-epoxy 0 μm components paint External layer Aluminum silicone 45 μm The outer surface of both tanks is thermally insulated, and for this reason only a minimum primer after sandblasting was required. 2.4 Gas boiler A propane gas-fired backup system is necessary to guarantee the necessary operating conditions (the DEAHP requires steam at ºC) and permit 24-hour MED-plant operation (to reduce the impact of capital costs) in absence of solar radiation. During the design phase of the AQUASOL Project, it was decided to install a C-class

Fig. 4: Front view of the PSA desalination building with the thermal storage tanks (left) and gas tank (right) smoke tube boiler so that the DEAHP can work at variable loads (from 30% to 0%). The gas to be burnt is stored in a 2,450-liter tank installed next to the distillation plant building. This tank volume provides an estimated autonomy of 143 hours at full load. Return condensate flow must be cooled in order to avoid flashing, and a heat exchanger is to be installed for this reason, transferring the energy to the stream that connects the absorption heat pump with the thermal storage tank. Fig. 6: Energy balance of PSA MED plant coupled to a Double Effect Absorption Heat Pump Three different system operating modes of the AQUASOL plant are possible depending on where the desalination unit energy supply comes from: Fig. 5: Gas boiler system installed in the PSA desalination building 2.5 Double-effect absorption heat pump The double effect absorption heat pump increases the energy efficiency of the distillation process by making use of the 35ºC saturated steam produced in the last MED plant effect, which would otherwise involve the loss of the energy (0 kw) in the evacuation of the cooling fluid used for its condensation, as the cold focus (See Fig. 6). Solar-only mode: energy to the first distillation effect comes exclusively from thermal energy from the solar collector field. Fossil-only mode: the double-effect heat pump supplies all of the heat required by the distillation plant Hybrid mode: the energy comes from both the heat pump and the solar field. It is planned to test two different operating philosophies. In the first, the heat pump works continuously 24 hours a day with a 30% minimum contribution, while second, pump starts up or shuts down, depending on the availability of the solar resource. Table 5 shows the thermal design of the DEAHP working at different load values. As can be seen, the coefficient of performance (COP), defined as the ratio between the power recovered at low temperature and the power delivered to the heat pump, drops as the steam load decreases.

TABLE 5: THERMAL DESIGN OF THE NEW DEAHP TO BE INSTALLED IN AQUASOL PROJECT Low pressure steam Cooling water High pressure steam Power (kw) Pressure inlet (bar) Temp. inlet (ºC) Flow rate (kg/s) Power (kw) Temp. inlet (bar) Temp. outlet (ºC) Flow rate (kg/s) Power (kw) Pressure inlet (bar) Temp. inlet (ºC) Flow rate (kg/s) DEAHP load (%) 0 75 50 30 0 75 50 30 0.051 0.051 0.051 0.051 35 35 35 35 0.041 0.031 0.021 0.0 182 67.7 82 0.039 139 66.7 62.5 0.031 95 65.8 42 0.021 56 65.2 26 0.014 COP 1.22 1.20 1.18 1.15 An advanced control system regulates the three-way regulating valve in the recirculation loop of the MED plant first cell. Temperatures inside the thermal storage tanks must be carefully monitored to determine the appropriate recirculation flow and avoid temperatures above 70ºC inside the MED first effect and also the DEAHP operating load (when available solar radiation becomes insufficient to feed the MED plant by itself). 2.6 Advanced solar dryer The purpose of the advanced solar dryer is to increase the concentration in the brine until it has reached the saturation point of calcium carbonate (16ºBe, Baumé scale). After the experimental evaluation of a series of small prototypes, a final solar dryer design has been proposed for evaluation during the AQUASOL Project demonstration phase. This dryer consists of three parallel 4-m-x-17-m interconnected evaporation channels with brine stream circulating inside them. The evaporation channels have a plastic cover, a preheating section at the inlet, and a solar chimney located at the outlet to promote air stream inside the channels (See Fig. 7). Fig. 7: Simulated view of the three advanced solar dryer modules proposed in the AQUASOL Project (courtesy of INETI) due to the predominant winds at the installation site. Simulation models foresee a 2.5 increase in efficiency compared to traditional open-air salt evaporation ponds. 3. CONCLUSIONS Research activities in solar thermal seawater desalination are currently carried out at the facilities of the Plataforma Solar de Almería in the framework of the AQUASOL Project. After the conclusion of the research phase, the final design of the proposed desalination system is being erected for testing during the project's demonstration phase. Use of a renewable energy source, such as solar thermal energy, in the desalination process, improved MED process efficiency through incorporation of the absorption heat pump technology, and reduction of the environmental impact of the desalination process effluent are the main goals of AQUASOL Project. 4. ACKNOWLEDGMENTS The authors wish to thank the European Commission (DG XII Research) for its financial assistance within the Energy, Environment and Sustainable Development Programme ( AQUASOL Project; Contract Nr. EVK1- CT2001-002). 5. REFERENCES [1] United Nations, Water for People, Water for Life UN World Water Development Report, UNESCO Publishing, Paris, 2003. [2] Wiseman, R., Desalination business stabilised on a high level IDA report, Desalination & Water Reuse 14(2), pp. 14-17, 2004. [3] McHarg, J. and Truby, R., West Coast researchers seek to demonstrate SWRO affordability, Desalination & Water Reuse 14(3), pp. -18, 2004. [4] Millow B. and Zarza E., Advanced MED solar desalination plants. Configurations, costs, future Seven years of experience at the Plataforma Solar de Almería (Spain), Desalination 8, pp. 51-58, 1996. [5] Gregorzewski, A. and Genthner, K., High efficiency seawater distillation with heat recovery by absorption heat pumps. Proceedings of the IDA World Congress on Desalination and Water Reuse, pp. 97-113, Abu Dhabi, November 18-24, 1995. A fourth open-air channel will be erected at the same time for realistic comparison of the new prototype s performance. A north-south orientation was finally chosen