Daikin Altherma Hybrid Heat Pump



Similar documents
Daikin Altherma Hybrid Heat Pump

Daikin Altherma Hybrid Heat Pump

The natural ombination

The natural ombination

Daikin Altherma hybrid heat pump. The natural combination

Daikin Altherma. hybrid heat pump. The natural combination

your comfort. our world. Daikin Aftercare Service For total peace of mind

your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump

ROTEX gas hybrid heat pump. A strong team.

Time to Rethink Heating

Hybrid heat pumps. saving energy and reducing carbon emissions

DAikin Altherma low temperature heat pump. end user leaflet

Daikin Altherma Hybrid Heat Pump

Fan Coil Units. Fan coil units with brushless DC motor with inverter. your comfort. our world. » Up to 70% energy saving with BLDC motor technology

your comfort. our world. R22 replacement A complete solution for R22 Sky Air systems

Natural geothermal energy.

your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction

Air-to-water heat pumps: Making the most of renewables. Richard Pickford, Daikin UK

ROTEX Gas-Hybrid-Heat Pump

Cooling kw Heating kw

Tackling the renovation challenge: high temperature hybrid heat pumps. François Bruggemans, DAIKIN Europe NV

Clearly Hybrid system

Vitocaldens 222-F Compact Gas-Hybrid appliance

Information Guide Domestic Air Source Heat Pumps

Create the right atmosphere with renewables.

Electric Flow Boiler

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Ecodan Air Source Heat Pump and Flow Temperature Controller 2

Gas Absorption Heat Pumps. Future proofing your heating and hot water

Heat Pumps in the Building Sector: Hybrid Heat Pumps opening UK retrofit opportunities?

The complete heating system.

Continuous flow direct water heating for potable hot water

Hybrid. Daikin Altherma. heat pump systems A POWERFUL TOOL TO CONTRIBUTE TO THE 20/20/20-TARGETS

Information Guide. The Application of Heat Pump Boilers. Issue Eighteen >

ALFEA HYBRID DUO GAZ. New Model 2011

Gas Condensing Boilers

High-efficient gas boiler CompactGas

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

R-32. The next generation refrigerant for air conditioners and heat pumps

LG Electronics AE Company, Commercial Air Conditioning

Air Conditioners Technical Data

A window of opportunity for hybrid heat pumps

Direct Fresh Air Free Cooling of Data Centres

omfort all-in-one applications for residential & commercial DAIKIN ALTHERMA HEATING CATALOGUE

The heat is there let s use it! Using free environmental heat from the air with heat pump technology for central heating and domestic hot water

Half the cost Half the carbon

Hotel solutions. for hotel owners. Heating - air conditioning - hot water - ventilation - refrigeration - control

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

The energy you need. Clearly Hybrid. hybrid. Efficient Solutions. Heating. Hot Water.

R-32. The next generation refrigerant for air conditioners and heat pumps. Superior energy efficiency and low GWP

omfort all-in-one applications for residential & commercial DAIKIN ALTHERMA HEATING CATALOGUE

The energy you need. Clearly Hybrid. hybrid. Efficient Solutions. Heating. Hot Water.

COMFORT ALL YEAR ROUND HEATING AND COOLING SOLUTIONS FOR YOUR HOME

ErP made easy What does it mean to merchants? What does it mean to installers?

Hybrid Heating Systems. Heat Pumps Working with a Traditional Boiler

INSTALLER CATALOGUE DAIKIN ALTHERMA LOW TEMPERATURE HEAT PUMP

Professional Report. Map section. Location of the system. Valkkinen Longitude: Latitude: Elevation: 89 m

Link-Up. Solid Fuel Association Guide to Central Heating.

york air-conditioning products Residential & VRF News 2015

Commercial Hot Water. Make a difference...

How to choose a heat pump and use it wisely

Endless Hot Water 24/7

UNDERSTANDING CENTRAL HEATING SYSTEMS

Gas Boilers - Commercial

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.

Air Conditioners Technical Data

HEAVY DUTY STORAGE GAS

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

Session 2: Hot Water Supply

THE EUROPEAN GREEN BUILDING PROGRAMME. Technical Module on Combined Heat and Power

Apartment and Communal Heating Solutions

Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets

DIETRISOL SOLAR WATER HEATING SYSTEMS ENERGY SAVINGS AND ECOLOGICAL BENEFITS SUSTAINED COMFORT SIMPLICITY AND RELIABILITY INNOVATIVE, MODULAR SYSTEMS

Subtropical Cities September Design for Energy Efficiency in Commercial Buildings in Queensland

SAP 2012 IN A NUTSHELL

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

Analysis of Energy Consumption. ACME Limited

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

Domestic Heating Energy Savings with Better Controls

The Business Case Annual fuel cost savings of 26% worth more than 28,000 Annual fuel savings of 1.3million kwh Annual CO2 savings of over 245 tonnes

AQUACIAT2 HYBRID THE COMPACT DUAL-ENERGY SOLUTION HEAT PUMP & GAS BOILER. Cooling and heating capacities of 45 to 80 kw AVAILABLE 2 ND QUARTER OF 2014

Air conditioners Heating & Cooling

The Worcester Greenstar System Filter. An innovative solution for reducing system contaminants

HEAT PUMPS A KEY COMPONENT IN LOW CARBON FUTURE

AQUAREA AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

AQUAREA AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS

CE29. Domestic heating by oil: boiler systems guidance for installers and specifiers

Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump

Condensing Boiler Efficiency

Smile. The All-In-One Heating Controller

CHP Plant based on a Hybrid Biomass and Solar System of the Next Generation EU project No. ENER/FP7/249800/"SUNSTORE 4" Dipl.-Ing. Alfred Hammerschmid

Response: The combi boiler. Response: The fit anywhere combi

New technical solutions for energy efficient buildings

Sino-Italian Environment & Energy Building S I E E B

Transcription:

your comfort. our world. Daikin Altherma Hybrid Heat Pump The natural combination Heating Integrated Solutions Ventilation Air Conditioning Refrigeration

About Daikin Forward thinking... Daikin has a worldwide reputation for quality and innovative technology, with over 50 years experience in the design and manufacture of heat pump solutions. Daikin is a leading supplier of heating, cooling, ventilation and refrigeration solutions for commercial, residential and industrial applications. Daikin provides a comprehensive choice of domestic heating and renewable energy products which are ideally suited to the UK housing market. A wholly owned subsidiary of Daikin Europe NV, Daikin UK has an excellent record of concern for environmental issues and applies it to all areas of the business, in many cases pre-empting international and national environmental legislation. Now is the time to rethink the way we heat our homes and hot water. Central heating systems as we have known them are changing dramatically and new solutions are needed to meet the Government s renewable energy targets. Homeowners are increasingly demanding that old heating systems are replaced with more efficient and more environmentally friendly systems that are cheaper to run, reduce carbon dioxide (CO2) emissions, reduce energy consumption and that protect their budget from rising fuel prices. Daikin is playing it s part. Heat pump systems are now available for all homes whether they are off the gas grid and now even for those homes connected to the gas network. The new Daikin Altherma Hybrid Heat Pump combines the benefits of a renewable energy air-water heat pump with a condensing gas combi boiler to make maximum use of the renewable energy and deliver completely reliable and controllable heating and hot water for homes. 2 Daikin Altherma Hybrid Heat Pump

New opportunities in domestic heating The extensive range of Daikin Altherma products provides solutions for all heating applications - new build, oil boiler replacement, and now also gas boiler replacement. Daikin Altherma Low Temperature Heat Pump is the ideal solution for new build applications and complete renovations, delivering the required heating, cooling and domestic hot water capacities for the house, with the best possible efficiencies. When replacing an oil boiler with a Daikin Altherma High Temperature Heat Pump, there is no need to replace the existing radiators, since the heat pump can achieve water temperatures of up to 80 C. The new Daikin Altherma hybrid Heat Pump offers new opportunities when replacing an old gas or LPG boiler. It is a costefficient solution combining a new gas condensing boiler and the most efficient air-to-water heat pump system on the market. Solutions for all heating applications 1 New Build 2 Renovation - change radiators 3 Renovation - keep radiators oil boiler replacement 4 Gas boiler replacement The new Daikin Altherma Hybrid Heat Pump Daikin Altherma low temperature 1 2 4 3 Daikin Altherma high temperature Combines heat pump technology with a condensing gas boiler Designed for properties on the gas network Ideal when replacing a gas or LPG boiler Connects to existing radiators (up to 80 C) Ideal for higher heat load properties (12 kw- 16kW) Lower running costs compared to a new condensing boiler Daikin Altherma Hybrid Heat Pump The natural combination 3

The new hybrid heat pump Daikin Altherma Hybrid Heat Pump combines a heat pump and a gas condensing boiler into one efficient renewable heating system. It uses a smart combination of a new condensing gas boiler and the most efficient air-to-water heat pump system on the market. Daikin Heat Pump outdoor unit 5kW Gas boiler DHW 33 kw / CH 27 kw Space heating up to 80 C Domestic hot water heating 600mm Refrigerant Radiator Heat pump convector All types of heat emitters Under floor heating Gas Cold water 4 Daikin Altherma Hybrid Heat Pump

How does it work? The Daikin Altherma Hybrid Heat Pump technology is carefully controlled to deliver the most cost efficient operation at every outdoor temperature. The switch-over between different operating modes depends on the relative cost of gas and electricity. The controller carefully monitors the indoor and outdoor temperatures along with the flow temperatures and decides which is the most cost effective operating mode. This ensures that the system is working most efficiently whilst still providing sufficient heating and hot water. Heat load kwh / C 3 Boiler only heating 2 Hybrid heating upto 10% higher efficiency than a condensing boiler Heat pump only operation -7 0 15 Ambient temperature ( C ) 1 1. High outdoor temperature zone: 100% heat pump 2. Mid outdoor temperature zone: heat pump + gas boiler - most cost efficient to operate both - additional capacity when required 3. Cold outdoor temperature zone: 100% gas boiler Typical application Location: London Heat load: 14 kw 70% heat pump output 30% gas boiler output The natural combination 5

Added benefits for installers, specifiers and householders Installer One heat pump solution for all on-gas and LPG renovation applications Easy and fast installation of renewable energy technology Opportunity to expand your heat pump business Specifier Lower running cost savings for properties on-gas and LPG A renewable energy system for hard to heat homes Helps to meet higher levels of the Code for Sustainable Homes Householder Higher running cost savings compared to a new gas condensing boiler Uses existing radiators minimises installation hassle Space saving renewable energy heating system fits in place of your old boiler 6 Daikin Altherma Hybrid Heat Pump

Installer benefits 1. ONE HEAT PUMP SOLUTION FOR ALL ON-GAS AND LPG APPLICATIONS Suitable for heat loads up to 27 kw (50 / 30 ) Connect to existing radiators (up to 80 C) Connect to all types of heat emitters Rapid start-up the gas boiler can be commissioned without the heat pump outdoor unit to quickly provide heating. Ideal where the existing boiler has broken down. 2. FAST INSTALLATION OF RENEWABLE ENERGY TECHNOLOGY Offers fast installation and easy maintenance No need to change existing radiators Similar dimensions to old boiler - minimises disruption and modifications All key hydraulic components included expansion vessel, circulation pump, filter Front access to key components for easy installation and maintenance Bottom connections familiar arrangement Extensive flue options available (60/100 flue system) Quick commissioning with advanced user interface 3. PEACE OF MIND Industry leading 3-year parts and labour warranty as standard Gas condensing boiler with 10-year warranty on the heat exchanger MCS applied for and pending Become a Daikin Hybrid Partner Working together to build your business Access to latest sales tools Support from our specialist heating sales team Access to dedicated design software Web pages designed to integrate seamlessly with your own site Installation and product training Dedicated on site after sales service support Support from Gas Safe registered Daikin service engineers The natural combination 7

Specifier benefits 1. ONE HEAT PUMP SOLUTION FOR ALL GAS AND LPG BOILER REPLACEMENT APPLICATIONS Ideal for hard to heat / treat homes - suitable for heat loads up to 27kW (50 / 30 ) Minimum investment cost and hassle - suitable for use with existing radiators Quick commissioning - boiler can be started without final commissioning of the heat pump for fast replacement in case of boiler break down Flexible for all property types - choice of DHW solutions: combi boiler and cylinder option 2. RENEWABLE ENERGY HEATING FOR ON-GAS PROPERTIES Meet renewable energy targets for on-gas properties Helps to meet higher levels of Code for Sustainable Homes Lower running costs for householders 3. EASY TO USE AND OPERATE Automatically selects most cost efficient operation mode to ensure lowest running costs Back-lit easy-to-use text display for householder confidence and comfort Gas boiler system: DHW 33, CH 27 kw Heat pump sytem: 5 kw 8 Daikin Altherma Hybrid Heat Pump

Householder benefits 1. SAVE MONEY COMPARED TO A NEW GAS CONDENSING BOILER Space heating up to 35% more efficient than new gas condensing boiler Efficient domestic hot water heating 3-year parts and labour warranty Heat load kwh / C Boiler only heating Hybrid heating upto 10% higher efficiency than a condensing boiler Heat pump only operation -7 0 15 Ambient temperature ( C ) Space heating Programmed for most cost efficient operation at every outdoor temperature Daikin hybrid logic to maximise heat pump usage Most efficient heat pump system on the market Domestic hot water heating Instantaneous hot water from a gas combi boiler High flow rate 13 litres / minute (dt 35 C) The Daikin Altherma Hybrid Heat Pump uses an efficient combi for domestic hot water heating. The direct flow burner provides both space heating and domestic hot water heating. By directly heating the cold water, the combi boiler can condense even in hot water mode increasing efficiency even further compared to traditional gas condensing boilers. 2. USE EXISTING RADIATORS AND CYLINDER No hassle from changing radiators or cylinder Lower investment costs Quicker to install The system is designed to work with existing system pipework and existing radiators to reduce installation disruption. 3. COMPACT AND SPACE SAVING 450 mm 400 mm With similar dimensions to an older boiler, the indoor boiler hybrid unit is designed to fit in place of the old boiler in the available installation space. 890 mm The natural combination 9

Daikin Altherma hybrid heat pump in practice Case Study A 110-year old solid wall mid-terraced home heated by high temperature radiators was chosen for the UK study. The house has a floor area of 140m 2 with a design heat load of 9kW at a design temperature of -6 C. The total annual energy demand is approximately 18,500 kwh, with 16,300kWh for heating. Results from the trial showed that 13,060 kwh of space heating was delivered by the heat pump. Clearly even in older properties, the hybrid heat pump is able to supply most of the energy required for space heating. The measured seasonal efficiency for this house was 1.26 for space heating and 1.2 for space heating and hot water combined. This is about 30% higher than a modern gas condensing boiler, based on a seasonal efficiency of 90% for space heating. Distribution of space heating energy by month Heat pump energy Boiler energy 3000 Space Heating kwh 2000 1000 960 1300 1450 1730 1965 1721 1545 1466 980 0 56 179 211 214 954 1047 237 251 49 Sept Oct Nov Dec Jan Feb Mar Apr May 10 Daikin Altherma Hybrid Heat Pump

Technical specifications GAS MODULE HEAT PUMP MODULE INDOOR UNIT *EHYKOMB33AA *EHYHBH05A Heating only Heating only Heating input (hi) Min. - Max. kw 7.5-32,7 - Heat output CH Min. - Max. 80/60 kw 7.9-31.9 - CH efficiency* NCV 80/60 % 98 - CH efficiency NCV 40/30 (30%) % 107 - DHW output Min. - Max. kw 7.9-31.9 - DHW efficiency NCV % 105 - Flow rate Max. dt 35K l/min. 13 - Dimensions Unit HeightxWidthxDepth mm 710x450x240 902x450x164 Weight Unit kg 36 29.8 SEDBUK applied for and pending OUTDOOR UNIT Heating capacity Nom. Heat pump operation only kw *EVLQ05CV3 4.40 1 4.03 2 COP Heat pump operation only 5.04 1 3.58 2 Dimensions Unit HeightxWidthxDepth mm 735x825x300 Sound power level Heating Nom. dba 61 Sound pressure level Heating Nom. dba 48 (1) heating Ta DB/WB 7 C/6 C - LWC 35 C (DT = 5 C) (2) heating Ta DB/WB 7 C/6 C - LWC 45 C (DT = 5 C) * Note: grey cells contain preliminary data The natural combination 11

your comfort. our world. Daikin units comply with the European regulations that guarantee the safety of the product. FSC Carbon Balanced Paper The present catalogue is drawn up by way of information only and does not Daikin products are distributed by: constitute an offer binding upon Daikin UK. Daikin UK has compiled the content of this catalogue to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin UK explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this catalogue. All content is copyrighted by Daikin UK. Daikin Airconditioning UK Limited The Heights Brooklands Weybridge Surrey KT13 0NY Tel 0845 6419000 Fax 0845 6419009 www.daikin.co.uk UKEPCEN13-961 / 06.13 / Copyright 2013 Daikin Printed in the UK on FSC certified paper from sustainable sources. Dedicated Heating Line: 0845 641 9070 Scotland Region 0845 641 9330 Northern Region 0845 641 9340 Midlands Region 0845 641 9370 Western Region 0845 641 9320 North London 0845 641 9360 South London 0845 641 9355