SPC BENCHMARK 1 EXECUTIVE SUMMARY HUAWEI TECHNOLOGIES CO., LTD. HUAWEI OCEANSTOR S5500T SPC-1 V1.13



Similar documents
SPC BENCHMARK 1 EXECUTIVE SUMMARY HUAWEI TECHNOLOGIES CO., LTD. HUAWEI OCEANSTOR 5500 V3 SPC-1 V1.14

SPC BENCHMARK 1 EXECUTIVE SUMMARY HUAWEI TECHNOLOGIES CO., LTD. HUAWEI OCEANSTOR 6800 V3 SPC-1 V1.14

SPC BENCHMARK 1 EXECUTIVE SUMMARY X-IO TECHNOLOGIES X-IO ISE 820 G3 ALL FLASH ARRAY SPC-1 V1.14

SPC BENCHMARK 1 EXECUTIVE SUMMARY HITACHI DATA SYSTEMS CORPORATION HITACHI UNIFIED STORAGE 150 (WITH SSDS) SPC-1 V1.13

SPC BENCHMARK 1 EXECUTIVE SUMMARY FUJITSU LIMITED FUJITSU STORAGE SYSTEMS ETERNUS DX600 S3 SPC-1 V1.14

SPC BENCHMARK 1/ENERGY EXECUTIVE SUMMARY IBM CORPORATION IBM FLASHSYSTEM 840 SPC-1/E V1.14

SPC BENCHMARK 1 EXECUTIVE SUMMARY

SPC BENCHMARK 1 EXECUTIVE SUMMARY HITACHI DATA SYSTEMS CORPORATION HITACHI VIRTUAL STORAGE PLATFORM G1000 (WITH HITACHI ACCELERATED FLASH) SPC-1 V1.

SPC BENCHMARK 1 EXECUTIVE SUMMARY IBM CORPORATION IBM STORWIZE V7000 SPC-1 V1.12. Submitted for Review: October 22, 2010 Submission Identifier: A00097

SPC BENCHMARK 1 EXECUTIVE SUMMARY 3PAR INC. 3PARINSERV T800 STORAGE SERVER SPC-1 V1.10.1

SPC BENCHMARK 1 FULL DISCLOSURE REPORT IBM CORPORATION IBM SYSTEM STORAGE SAN VOLUME CONTROLLER V6.2 SPC-1 V1.12

SEAGATE 600GB 15K 12GBPS SAS 2.5" ENTERPRISE PERFORMANCE HDD/ST600MP0065 SPC-1C V1.5

SPC BENCHMARK 1 EXECUTIVE SUMMARY

SPC BENCHMARK 1 EXECUTIVE SUMMARY HEWLETT PACKARD ENTERPRISE HPE 3PAR STORESERV 8450 STORAGE SYSTEM SPC-1 V1.14

SPC BENCHMARK 1C FULL DISCLOSURE REPORT SEAGATE TECHNOLOGY LLC IBM 600GB 10K 6GBPS SAS 2.5" G2HS HYBRID SPC-1C V1.5

SPC BENCHMARK 2/ENERGY EXECUTIVE SUMMARY ORACLE CORPORATION ORACLE ZFS STORAGE ZS3-2 APPLIANCE (2-NODE CLUSTER) SPC-2/E V1.5

SPC BENCHMARK 1 FULL DISCLOSURE REPORT EMC CORPORATION EMC VNX8000 SPC-1 V1.14. Submitted for Review: July 30, 2015 Submission Identifier: A00159

SPC BENCHMARK 1 FULL DISCLOSURE REPORT DATACORE SOFTWARE CORPORATION DATACORE SANMELODY DISK SERVER (ISCSI-STD. NIC) SPC-1 V1.8

SPC BENCHMARK 1 FULL DISCLOSURE REPORT IBM CORPORATION IBM SYSTEM STORAGE DS8700 RELEASE 5.1 (EASY TIER AND SSDS) SPC-1 V1.12

SPC BENCHMARK 1C FULL DISCLOSURE REPORT SEAGATE TECHNOLOGY LLC IBM 600GB 10K 6GBPS SAS 2.5" SFF SLIM-HS HDD SPC-1C V1.5

SPC BENCHMARK 1 EXECUTIVE SUMMARY HITACHI DATA SYSTEMS CORPORATION HITACHI UNIVERSAL STORAGE PLATFORM V SPC-1 V1.10.1

Accelerate Oracle Performance by Using SmartCache of T Series Unified Storage

HUAWEI OceanStor S5500T Exchange Server 2010 Solution with Users

HUAWEI Virtual Desktop Solution with VMware Horizon 6.0 with View

HUAWEI Virtual Desktop Solution Reference Architecture with VMware Horizon View 5.3

Key Messages of Enterprise Cluster NAS Huawei OceanStor N8500

Simple and Intelligent. Unified Storage. Unified Storage. All SSD Storage NAS Storage. Did you know?

White Paper for Microsoft Private Cloud Fast Track on Huawei Server and Storage System

FAS6200 Cluster Delivers Exceptional Block I/O Performance with Low Latency

Best Practices for VMware Horizon View VDI Based on HUAWEI OceanStor 5500 V3 Converged Storage System. Huawei Technologies Co., Ltd.

Silverton Consulting, Inc. StorInt Briefing Introduction Enterprise challenges

REPLIES TO PRE BID REPLIES FOR REQUEST FOR PROPOSAL FOR SUPPLY, INSTALLATION AND MAINTENANCE OF SERVERS & STORAGE

HUAWEI TECHNOLOGIES CO., LTD.

The Benefit of Migrating from 4Gb to 8Gb Fibre Channel

The safer, easier way to help you pass any IT exams. Exam : Storage Sales V2. Title : Version : Demo 1 / 5

UNIFIED HYBRID STORAGE. Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment

White Paper. Educational. Measuring Storage Performance

Evaluation Report: Supporting Microsoft Exchange on the Lenovo S3200 Hybrid Array

Cisco-EMC Microsoft SQL Server Fast Track Warehouse 3.0 Enterprise Reference Configurations. Data Sheet

Dell Exchange 2013 Reference Architecture for 500 to 20,000 Microsoft Users. 1 Overview. Reliable and affordable storage for your business

HP 4 Gb PCI-X 2.0 Host Bus Adapters Overview

How To Evaluate Netapp Ethernet Storage System For A Test Drive

HUAWEI OceanStor Enterprise Storage System Success Cases

IOmark- VDI. Nimbus Data Gemini Test Report: VDI a Test Report Date: 6, September

STORAGE CENTER. The Industry s Only SAN with Automated Tiered Storage STORAGE CENTER

F600Q 8Gb FC Storage Performance Report Date: 2012/10/30

OceanStor 18500/18800/18800F Data Sheet

The IntelliMagic White Paper: Storage Performance Analysis for an IBM Storwize V7000

Oracle Database Scalability in VMware ESX VMware ESX 3.5

Key Messages on HUAWEI OceanStor series Enterprise Storage System

Technical White Paper for the Oceanspace VTL6000

QLogic 8Gb FC Single-port and Dual-port HBAs for IBM System x IBM System x at-a-glance guide

EonStor DS G7i - Fibre Channel Solutions Affordable and flexible storage solutions featuring enterprise-class data-protection

Storage Systems Performance Testing

EMC Backup and Recovery for Microsoft SQL Server

Module: Sharepoint Administrator

FUJITSU Storage ETERNUS DX200 S3 Performance. Silverton Consulting, Inc. StorInt Briefing

Redundancy in enterprise storage networks using dual-domain SAS configurations

Capacity planning for IBM Power Systems using LPAR2RRD.

Violin Memory Arrays With IBM System Storage SAN Volume Control

White paper 200 Camera Surveillance Video Vault Solution Powered by Fujitsu

New Cluster-Ready FAS3200 Models

Oracle Database Deployments with EMC CLARiiON AX4 Storage Systems

Introduction of Huawei Backup Solution

The Data Placement Challenge

DELL RAID PRIMER DELL PERC RAID CONTROLLERS. Joe H. Trickey III. Dell Storage RAID Product Marketing. John Seward. Dell Storage RAID Engineering

MICROSOFT EXCHANGE best practices BEST PRACTICES - DATA STORAGE SETUP

Evaluation Report: Accelerating SQL Server Database Performance with the Lenovo Storage S3200 SAN Array

VMware Best Practice and Integration Guide

OceanStor 18500/18800/18800F Enterprise Storage System

IBM System Storage DS5020 Express

The introduction of storage presales tool-edesigner. Storage edesigner Project Team

2015 FRCA Installation and Supply of Data Center Infrastructure TENDER 11/2015. Requirement Specification Document

WHITE PAPER Improving Storage Efficiencies with Data Deduplication and Compression

Scalable. Reliable. Flexible. High Performance Architecture. Fault Tolerant System Design. Expansion Options for Unique Business Needs

KVM Virtualized I/O Performance

Private cloud computing advances

End-to-end Data integrity Protection in Storage Systems

Infortrend ESVA Family Enterprise Scalable Virtualized Architecture

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure

EMC XtremSF: Delivering Next Generation Performance for Oracle Database

All-Flash Storage Solution

Building Backup-to-Disk and Disaster Recovery Solutions with the ReadyDATA 5200

Evaluation Report: HP Blade Server and HP MSA 16GFC Storage Evaluation

Business-centric Storage for small and medium-sized enterprises. How ETERNUS DX powered by Intel Xeon processors improves data management

Technical White Paper ETERNUS DX8700 S2 Hardware Architecture

RAID Performance Analysis

SAN TECHNICAL - DETAILS/ SPECIFICATIONS

Doc. code. Huawei OceanStor T Series Technical White Paper. Issue V3.0. Date HUAWEI TECHNOLOGIES CO., LTD.

No matter what you need for Managed IT services, High-Performance Storage, you can count on us for low cost, fast and effective service.

Architecting a High Performance Storage System

Enhancements of ETERNUS DX / SF

Business-centric Storage for small and medium-sized enterprises. How ETERNUS DX powered by Intel Xeon processors improves data management

The Benefits of Virtualizing

Deploying Microsoft Exchange Server 2010 on the Hitachi Adaptable Modular Storage 2500

Measuring Interface Latencies for SAS, Fibre Channel and iscsi

Performance characterization report for Microsoft Hyper-V R2 on HP StorageWorks P4500 SAN storage

SUN STORAGE F5100 FLASH ARRAY

FlexArray Virtualization

Transcription:

SPC BENCHMARK 1 EXECUTIVE SUMMARY HUAWEI TECHNOLOGIES CO., LTD. HUAWEI OCEANSTOR S5500T SPC-1 V1.13 Submitted for Review: November 12, 2012 Submission Identifier: A00122

EXECUTIVE SUMMARY Page 2 of 8 EXECUTIVE SUMMARY Test Sponsor and Contact Information Test Sponsor Primary Contact Test Sponsor Alternate Contact Auditor Test Sponsor and Contact Information Huawei Technologies Co., Ltd. http://www.huawei.com/en/ Eric He eric.heji@huawei.com Tianchen Road 88# Chengdu, Sichuan, P.R. China 611711 Phone: 86 28 62905595 FAX: 86 28 62905793 Huawei Technologies Co., Ltd. http://www.huawei.com/en/ Tao Dang dangtao@huawei.com Tianchen Road 88# Chengdu, Sichuan, P.R. China 611711 Phone: 86 28 62905591 FAX: 86 28 62905793 Storage Performance Council http://www.storageperformance.org Walter E. Baker AuditService@StoragePerformance.org 643 Bair Island Road, Suite 103 Redwood City, CA 94063 Phone: (650) 556-9384 FAX: (650) 556-9385 Revision Information and Key Dates Revision Information and Key Dates SPC-1 Specification revision number V1.13 SPC-1 Workload Generator revision number V2.3.0 Date Results were first used publicly November 12, 2012 Date the FDR was submitted to the SPC November 12, 2012 Date the Priced Storage Configuration is available for shipment to customers currently available Date the TSC completed audit certification November 11, 2012 Tested Storage Product (TSP) Description Huawei OceanStor T series unified storage system (T series) is a new-generation storage product for mid-range and high-end storage applications. It boasts integration of block-level and file-level data storage, support for a variety of storage protocols, and GUI-based central storage management. Delivering leading performance, enhanced efficiency, maximized return on investment, and all-in-one solutions, the T series is ideally applicable to scenarios such as large-database OLTP/OLAP, high-performance computing, digital media, Internet applications, central storage, backup, disaster recovery, and data migration.

EXECUTIVE SUMMARY Page 3 of 8 Summary of Results SPC-1 Reported Data Tested Storage Product (TSP) Name: Metric SPC-1 IOPS 60,242.22 Reported Result SPC-1 Price-Performance Total ASU Capacity Data Protection Level $2.96/SPC-1 IOPS 21,367.462 GB Protected 1 (Mirroring) Total Price $178,191.00 Currency Used Target Country for availability, sales and support U.S. Dollars USA SPC-1 IOPS represents the maximum I/O Request Throughput at the 100% load point. SPC-1 Price-Performance is the ratio of Total Price to SPC-1 IOPS. Total ASU (Application Storage Unit) Capacity represents the total storage capacity available to be read and written in the course of executing the SPC-1 benchmark. A Data Protection Level of Protected 1 using Mirroring configures two or more identical copies of user data. Protected 1: The single point of failure of any storage device in the configuration will not result in permanent loss of access to or integrity of the SPC-1 Data Repository. Total Price includes the cost of the Priced Storage Configuration plus three years of hardware maintenance and software support as detailed on page 6. Currency Used is formal name for the currency used in calculating the Total Price and SPC-1 Price-Performance. That currency may be the local currency of the Target Country or the currency of a difference country (non-local currency). The Target Country is the country in which the Priced Storage Configuration is available for sale and in which the required hardware maintenance and software support is provided either directly from the Test Sponsor or indirectly via a third-party supplier.

EXECUTIVE SUMMARY Page 4 of 8 Storage Capacities, Relationships, and Utilization The following diagram and table document the various storage capacities, used in this benchmark, and their relationships, as well as the storage utilization values required to be reported. Application Storage Unit (ASU) Capacity 21,367.462 GB ASU 1 9,615.358 GB ASU 2 9,615.358 GB Addressable Storage Capacity 21,370.231 GB ASU 3 2,136.746 GB ASU1: 15 Logical Volumes, 641.116 GB/Volume ASU2: 15 Logical Volumes, 641.116 GB/Volume ASU3: 2 Logical Volumes, 1,068.373 GB/Volume Unused 2.768 GB Unused 5,509.285 GB Configured Storage Capacity 53,759.032 GB Physical Storage Capacity 54,001.527 GB Data Protection (Mirroring) 26,879.516 GB (includes 5,512.054 GB of Unused Capacity) Unused 49.392 GB Global Storage Overhead 193.103 GB SPC-1 Storage Capacity Utilization Application Utilization 39.57% Protected Application Utilization 79.14% Unused Storage Ratio 20.51% Application Utilization: Total ASU Capacity (21,367.462 GB) divided by Physical Storage Capacity (54,001.527 GB) Protected Application Utilization: Total ASU Capacity (21,367.462 GB) plus total Data Protection Capacity (26,879.516 GB) minus unused Data Protection Capacity (5,512.054 GB) divided by Physical Storage Capacity (54,001.527 GB) Unused Storage Ratio: Total Unused Capacity (11,073.499 GB) divided by Physical Storage Capacity (54,001.527 GB) and may not exceed 45%. Detailed information for the various storage capacities and utilizations is available on pages 21-22 in the Full Disclosure Report.

EXECUTIVE SUMMARY Page 5 of 8 Response Time Throughput Curve The Response Time-Throughput Curve illustrates the Average Response Time (milliseconds) and I/O Request Throughput at 100%, 95%, 90%, 80%, 50%, and 10% of the workload level used to generate the SPC-1 IOPS metric. The Average Response Time measured at the any of the above load points cannot exceed 30 milliseconds or the benchmark measurement is invalid. Ramp Phase Response Time / Throughput Curve 30 25 20 Response Time (ms) 15 10 5 10% 50% 80% 100% 95% 90% 0 0 10000 20000 30000 40000 50000 60000 70000 IO Requests per Second Response Time Throughput Data 10% Load 50% Load 80% Load 90% Load 95% Load 100% Load I/O Request Throughput 6,003.11 30,109.86 48,194.42 54,190.96 57,211.51 60,242.22 Average Response Time (ms): All ASUs 2.88 4.32 5.41 6.13 6.65 7.60 ASU-1 3.84 5.37 6.88 7.72 8.31 9.29 ASU-2 3.41 5.63 8.08 9.51 10.46 11.98 ASU-3 0.61 1.50 1.14 1.27 1.46 2.11 Reads 6.49 8.82 12.13 13.78 14.85 16.42 Writes 0.54 1.39 1.04 1.15 1.31 1.86

EXECUTIVE SUMMARY Page 6 of 8 Differences between the Tested Storage Configuration (TSC) and Priced Storage Configuration There were no differences between the TSC and the Priced Storage Configuration. Priced Storage Configuration Pricing Part Number Description Quantity Unit Price Total Price Control module 10,401.00 SPE31C0212-33 Controller Enclosure(2U,3.5",Dual Controller,AC,32GB Cache,2*4*8G FC Front-End SPE31C0212-S33-2C32G-8F8- Port,2*2*24G SAS Back-End Port(Wide Port),UPS Cache AC-BASE Protected Module,HS Storage Array Control System Softw are) 1 10,401.00 10,401.00 Hard Disk Drives 73,236.00 SAS300-15K-2 300GB 15K RPM SAS Disk Unit(3.5") 156 418.00 65,208.00 SAS600-15K-2 Disk Enclosure 600GB 15K RPM SAS Disk Unit(3.5") 12 669.00 8,028.00 21,042.00 DAE12435U4-AC DAE12435U4-03 Disk Enclosure(4U,3.5",AC,SAS Expansion Module,w ithout Disk Unit,w ith HS SAS in Band Management Softw are) 7 3,006.00 21,042.00 Accessory 289.00 SS-OP-D-LC-M-3 Patchcord,DLC/PC-DLC/PC,Multimode,2mm Parallel,3m 8 11.00 88.00 MINI-SAS-3 Purchased Cable,MiniSAS Cable,Key246,3m 3 67.00 201.00 Storage management software 3,554.00 LIC-UltraPath02-V1R5 OceanStor HS UltraPath Softw are License 1 1,938.00 1,938.00 LIC-S3A-ISM02-BLOCK HS Integrated Storage Manager-Device Management License for OceanStor Block S5500T 1 1,616.00 1,616.00 Third Party 1,698.00 N8GHBA000 QLOGIC QLE2562 HBA Card,PCIE,8Gbps DualPort,Fiber Channel Multimode LC Optic Interface,English Manual,Driver 1 1,698.00 1,698.00 CD Total of Product 110,220.00 Maintenance Support Service 67,971.00 Hi-Care Premier On-Site Service (3 years) 1 67,971.00 67,971.00 Total of Service (3 years) 67,971.00 Total Price 178,191.00 Notes: Hi-Care Premier On-Site Service include: 7*24 Technical Assistance Center Access. Access to all new software updates and Online Support. 24*7*4 Hours Onsite Hardware Replacement

EXECUTIVE SUMMARY Page 7 of 8 The above pricing includes hardware maintenance and software support for three years, 7 days per week, 24 hours per day. The hardware maintenance and software support provides the following: Acknowledgement of new and existing problems with four (4) hours. Onsite presence of a qualified maintenance engineer or provision of a customer replaceable part within four (4) hours of the above acknowledgement for any hardware failure that results in an inoperative Priced Storage Configuration that can be remedied by the repair or replacement of a Priced Storage Configuration component. Huawei Technologies Co., Ltd. only sells its products to third-party resellers, who in turn, sell those products to U.S. customers. The above pricing, which also includes the required three-year maintenance and support, was obtained from one of those third-party resellers. See Appendix F: Third-Party Quotation in the Full Disclosure Report for a copy of the third-party reseller quotation.

EXECUTIVE SUMMARY Page 8 of 8 Priced Storage Configuration Diagram 1 - Qlogic dual-port QLE 2562 FC HBA 2 Fiber Channel Connections 8 Gbps FC Huawei OceanStor TM S5500T 6 Gbps SAS dual controllers - Active-Active 16 GB cache per controller (32GB total) 12 - disk drives 7 - disk enclosures 168-15K RPM SAS disk drives 12-300GB 15K RPM SAS disk drives in the controller enclosure 144-300GB 15K RPM SAS disk drives in disk enclosures 1-6 12-600GB 15K RPM SAS disk drives in disk enclosure 7 Priced Storage Configuration Components Priced Storage Configuration: 1 Qlogic dual-port QLE2562 FC HBA dual controllers Active-Active 16 GB cache per controller (32 GB total) 4 8 Gbps front-end connection per controller (8 total, 2 used) 2 2x24 Gbps SAS backend connections per controller (4 total, 4 used) 12 300 GB, 15K RPM disk drives 7 Disk Enclosures 24 3.5 HD slots per enclosure 156 300 GB, 15K RPM SAS disk drives 12 disk drives in the controller enclosure 24 disk drives/enclosure in enclosures1-6 12 600 GB, 15K RPM SAS disk drives 12 disk drives in enclosure 7