SPC BENCHMARK 2/ENERGY EXECUTIVE SUMMARY ORACLE CORPORATION ORACLE ZFS STORAGE ZS3-2 APPLIANCE (2-NODE CLUSTER) SPC-2/E V1.5
|
|
|
- Joan Evans
- 10 years ago
- Views:
Transcription
1 SPC BENCHMARK 2/ENERGY EXECUTIVE SUMMARY ORACLE CORPORATION ORACLE ZFS STORAGE ZS3-2 APPLIANCE (2-NODE CLUSTER) SPC-2/E V1.5 Submitted for Review: June 25, 2014
2 EXECUTIVE SUMMARY Page 2 of 12 EXECUTIVE SUMMARY Test Sponsor and Contact Information Test Sponsor Primary Contact Test Sponsor Alternate Contact Auditor Test Sponsor and Contact Information Steven Johnson [email protected] 500 Eldorado Blvd. Broomfield, CO Phone: (303) Jason Schaffer [email protected] 500 Eldorado Blvd. Broomfield, CO Phone: (303) FAX: (303) Storage Performance Council Walter E. Baker [email protected] 643 Bair Island Road, Suite 103 Redwood City, CA Phone: (650) FAX: (650) Revision Information and Key Dates Revision Information and Key Dates SPC-2 Specification revision number V1.5 SPC-2 Workload Generator revision number V1.2 Date Results were first used publicly June 25, 2014 Date FDR was submitted to the SPC June 25, 2014 Date the TSC will be available for shipment to customers May 9, 2014 Date the TSC completed audit certification April 25, 2014 Tested Storage Product (TSP) Description Oracle's ZFS Storage ZS3-2 is a high-performance storage system that offers enterpriseclass SAN and NAS capabilities with industry-leading Oracle Database integration, in a cost-effective high-availability configuration. The ZFS Storage ZS3-2 offers simplified set up and management combined with industry-leading storage analytics and a performanceoptimized platform that uses specialized Read and Write Flash-bases SSD caching devices. The ZFS Storage ZS3-2 can scale to 512 GB Memory, 32 CPU cores, and 768 TB capacity, with up to 12.8 TB of Flash Cache in a high-availability configuration. ZFS Storage Appliances deliver additional economic value bundled data services such as file- and blocklevel protocols including connectivity over InfiniBand, Compression, Deduplication, Thin provisioning, DTrace Analytics, Virus Scan, Snapshots, Triple Mirror, Triple Parity RAID, Phone-home, NDMP, Clustering, etc."
3 EXECUTIVE SUMMARY Page 3 of 12 SPC-2 Reported Data SPC-2 Reported Data consists of three groups of information: The following SPC-2 Primary Metrics, which characterize the overall benchmark result: SPC-2 MBPS SPC-2 Price Performance Application Storage Unit (ASU) Capacity Supplemental data to the SPC-2 Primary Metrics. Total Price Data Protection Level Reported Data for each SPC Test: Large File Processing (LFP), Large Database Query (LDQ), and Video on Demand Delivery (VOD) Test. SPC-2 MBPS represents the aggregate data rate, in megabytes per second, of all three SPC-2 workloads: Large File Processing (LFP), Large Database Query (LDQ), and Video on Demand (VOD). SPC-2 Price-Performance is the ratio of Total Price to SPC-2 MBPS. ASU (Application Storage Unit) Capacity represents the total storage capacity available to be read and written in the course of executing the SPC-2 benchmark. Total Price includes the cost of the Priced Storage Configuration plus three years of hardware maintenance and software support as detailed on page on page 10. Data Protection Level of Protected 2 using Mirroring, which configures two or more identical copies of user data. Protected 2: The single point of failure of any component in the configuration will not result in permanent loss of access to or integrity of the SPC-2 Data Repository. Currency Used is formal name for the currency used in calculating the Total Price and SPC-2 Price-Performance. That currency may be the local currency of the Target Country or the currency of a difference country (non-local currency). The Target Country is the country in which the Priced Storage Configuration is available for sale and in which the required hardware maintenance and software support is provided either directly from the Test Sponsor or indirectly via a third-party supplier.
4 EXECUTIVE SUMMARY Page 4 of 12 SPC-2 Reported Data (continued) SPC-2 Reported Data SPC-2 MBPS SPC-2 Price-Performance ASU Capacity (GB) Total Price Data Protection Level 16, $ , $195, Protected 2 (Mirroring) The above SPC-2 MBPS value represents the aggregate data rate of all three SPC-2 workloads: Large File Processing (LFP), Large Database Query (LDQ), and Video On Demand (VOD) Currency Used: "Target Country": U.S. dollars USA SPC-2 Large File Processing (LFP) Reported Data Data Rate (MB/second) Number of Streams Data Rate per Stream Price-Performance LFP Composite 10, $18.12 Write Only: 1024 KiB Transfer 7, KiB Transfer 2, , Read-Write: 1024 KiB Transfer 12, , KiB Transfer 3, , Read Only: 1024 KiB Transfer 19, KiB Transfer 19, , The above SPC-2 Data Rate value for LFP Composite represents the aggregate performance of all three LFP Test Phases: (Write Only, Read-Write, and Read Only). SPC-2 Large Database Query (LDQ) Reported Data Data Rate (MB/second) Number of Streams Data Rate per Stream Price-Performance LDQ Composite 18, $ KiB Transfer Size 4 I/Os Outstanding 19, I/O Outstanding 19, KiB Transfer Size 4 I/Os Outstanding 18, I/O Outstanding 17, , The above SPC-2 Data Rate value for LDQ Composite represents the aggregate performance of the two LDQ Test Phases: (1024 KiB and 64 KiB Transfer Sizes). SPC-2 Video On Demand (VOD) Reported Data Data Rate (MB/second) Number of Streams Data Rate per Stream Price-Performance 18, , $10.38
5 EXECUTIVE SUMMARY Page 5 of 12 SPC-2/E Reported Data The initial temperature, recorded during the first one minute of the SPC-2/E Idle Test was 73.20F. The final temperature, recorded during the last one minute of the SPC-2/E Large Database Query (LDQ) Test was 73.20F. Power Environment Average RMS Voltage: Average Power Factor: Usage Profile Nominal Hours of Use per Day Pow er Traffic Ratio Heat Heavy Moderate Idle watts MBPS MBPS/w BTU/hr Low Daily Usage: , Medium Daily Usage: , High Daily Usage: , Composite Metrics: 3, , Annual Energy Use, kwh: 26, Energy Cost, $/kwh: $ 0.12 Annual Energy Cost, $: $ 3, HEAVY SPC-2 Workload: 3,219.55W at a data rate of 17, MB/s. MODERATE SPC-2 Workload: 3,180.10W at a data rate of 15, MB/s. IDLE SPC-2 Workload: 2,686.31W at data rate of zero (0). The above usage profile describes conditions in environments that respectively impose light (Low Daily Usage), moderate (Medium Daily Usage), and extensive (High Daily Usage) demands on the Tested Storage Configuration (TSC). The data in this profile represents the combined results of all three SPC-2 workloads: Large File Processing (LFP), Large Database Query (LDQ) and Video on Demand Delivery (VOD). The detailed SPC-2/E Reported Data and associated charts for each workload, including the Idle Test, are available in this document, via the hyperlinks listed below: The SPC-2/E Idle Test chart SPC-2/E Large File Processing (LFP) Reported Data table and associated charts SPC-2/E Large Database Query (LDQ) Reported Data table and associated charts SPC-2/E Video on Demand Delivery (VOD) Reported Data table and associated charts The definitions, listed below, for the remaining items in the above SPC-2/E Reported Data table, are identical for the SPC-2/E Reported Data tables for each of the three individual SPC-2 workloads: LFP, LDQ and VOD. AVERAGE RMS VOLTAGE: The average supply voltage applied to the Tested Storage Product (TSP) as measured during the Measurement Intervals of the SPC-2 Tests.
6 EXECUTIVE SUMMARY Page 6 of 12 AVERAGE POWER FACTOR: The ratio of average real power, in watts, to the average apparent power, in volt-amps flowing into the Tested Storage Product (TSP) during the Measurement Intervals of the SPC-2 Tests. NOMINAL POWER, W: The average power consumption over the course of a day (24 hours), taking into account hourly load variations. NOMINAL TRAFFIC, MBPS: The average data rate over the course of a day (24 hours), taking into account hourly load variations. NOMINAL MBPS/W: The overall efficiency with which the reported data rate can be supported, reflected by the ratio of NOMINAL TRAFFIC versus the NOMINAL POWER. NOMINAL HEAT, BTU/HR: The average amount of heat required to be dissipated over the course of a day (24 hours), taking into account hourly load variations. (1 watt = BTU/hr) COMPOSITE METRICS: The aggregated NOMINAL POWER, NOMINAL TRAFFIC, and NOMINAL MBPS/W for all three environments: LOW, MEDIUM, and HIGH DAILY USAGE. ANNUAL ENERGY USE, KWH: An estimate of the average energy use across the three environments over the course of a year and computed as (NOMINAL POWER * 24 *0.365). ENERGY COST, $/KWH: A standardized energy cost per kilowatt hour. ANNUAL ENERGY COST: An estimate of the annual energy use across the three environments over the course of a year and computed as (ANNUAL ENERGY USE * ENERGY COST).
7 EXECUTIVE SUMMARY Page 7 of 12 Storage Capacities and Relationships The following four charts and table document the various storage capacities, used in this benchmark, and their relationships, as well as the storage utilization values required to be reported. The capacity values in each of the following four charts are listed as integer values, for readability, rather than the decimal values listed elsewhere in this document.
8 EXECUTIVE SUMMARY Page 8 of 12
9 EXECUTIVE SUMMARY Page 9 of 12 SPC-2 Storage Capacity Utilization Application Utilization 27.99% Protected Application Utilization 55.99% Unused Storage Ratio 41.23% Application Utilization: Total ASU Capacity (24, GB) divided by Physical Storage Capacity (86, GB). Protected Application Utilization: Total ASU Capacity (24, GB) plus total Data Protection Capacity (41, GB) minus unused Data Protection Capacity 17, (GB) divided by Physical Storage Capacity (86, GB). Unused Storage Ratio: Total Unused Capacity (35, GB) divided by Physical Storage Capacity (86, GB) and may not exceed 45%. Detailed information for the various storage capacities and utilizations is available on pages in the Full Disclosure Report.
10 EXECUTIVE SUMMARY Page 10 of 12 Priced Storage Configuration Pricing Part Number Description Quantity US List Total List Discount Net Price Oracle ZFS Storage ZS3-2: controller, includes SAS2 PCIE 16 port HBA 2 $17, $34, % $20, One 16 GB DDR registered DIMM (for factory installation) 32 $ $9, % $7, SAS PCIE 6Gbs 16 port (for factory installation) 2 $1, $2, % $1, Cable: 3 meters, mini SAS to mini SAS HD (for factory installation) 8 $ $1, % $ Sun Storage 16Gbs FC PCIe HBA, dual port, Qlogic 6 $1, $10, % $6, Sun Storage 2x16Gbs FC optics, SR, Qlogic 6 $ $5, % $3, SR-JUMP-1MC13 Power cord: Sun Rack 2 jumper, 1 meter, C14RA plug, C13 connector, 13 A (for factory installation) 4 $29.00 $ % $ Oracle Storage Drive Enclosure DE2-24P: base chassis (for factory installation) 12 $4, $48, % $29, One 300 GB rpm 2.5 inch SAS-2 HDD with evo bracket (for factory installation) 288 $ $99, % $59, SR-JUMP-1MC13 Power cord: Sun Rack 2 jumper, 1 meter, C14RA plug, C13 connector, 13 A (for factory installation) 24 $29.00 $ % $ SR-1242-N Sun Rack II, 42U, 1200mm depth, 600mm width, empty shipping only (do not install product inside the rack while it is on this pallet) 1 $2, $2, % $1, SR-10K-L630-N Sun Rack II 10kVA PDU, Single Phase, 48 Supplied Amps Max, NEMA L6-30P on 4m captive cords, Data Center Two 30A NEMA L6-30R (30A breakers), 42 C13 and 6 C19 Outlets in 6 Groups, Current Metering. 1 $ $ % $ SR-JUMPKIT-N Jumper Cable Start Up Kit: qty 10 of 1 meter C13 plugs + qty 10 of 2 meter C13 plugs + qty 2 1 meter C19 plugs + Qty 2 2meter C19 plugs 1 $ $ % $ Sun Storage 16Gbs FC PCIe HBA, dual port, Qlogic 6 $2, $12, % $7, Sun Storage 2x16Gbs FC optics, SR, Qlogic 6 $1, $6, % $4, X9732A-Z-N 2M LC to LC FC Optical Cable RoHS-6 compliant 12 $65.00 $ % $ Oracle Premium Support for Systems: 1-Year 7/24, 2 hour response time. 3 $84, $51, TOTALS $320, $195, The following pricing includes the following: Acknowledgement of new and existing hardware and/or software problems within four hours. Onsite presence of a qualified maintenance engineer or provision of a customer replaceable part within four hours of the above acknowledgement for any hardware failure that results in an inoperative Priced Storage Configuration component. Differences between the Tested Storage Configuration (TSC) and Priced Storage Configuration The TSC was configured with two PDUs to better distribute the measurement demand on the Yokogawa power meter. The Priced Storage was configured with a single PDU, which is sufficient to power the both the TSC and Priced Storage Configuration. The use of one PDU in the TSC would have no impact on the reported performance.
11 EXECUTIVE SUMMARY Page 11 of 12 Priced Storage Configuration Diagram 6 16 Gb FC dual-port HBAs (12 16 Gb FC connections 6 connections per controller) Oracle ZS3-2 Controller A (256 GB cache) 3 16 Gb FC dual-port HBAs (6 16 Gb FC connections) Oracle ZS3-2 Controller B (256 GB cache) 3 16 Gb FC dual-port HBAs (6 16 Gb FC connections) Clustron Connections 2 6 Gb SAS2 Quad port HBAs (8 6 Gb SAS connections) 2 6 Gb SAS2 Quad port HBAs (8 6 Gb SAS connections) 2 Oracle ZFS ZS3-2 controllers (cluster configuration) (256 GB cache per controller, 512 GB total) 6 16 Gb FC dual-port HBAs (3 HBAs per controller) (6 16 Gb FC connections per controller, 12 total, 12 used) 4 6 Gb SAS 16 port HBAs (2 HBAs per controller) (32 6 Gb logical SAS connections per controller, 64 total, 64 used) 12 Sun disk shelf base (2 SAS I/O modules per base) GB 10K RPM 2.5 SAS-2 Disk Drives 1 Sun Rack II 42U 2 Sun Rack II 10kVA PDUs
12 EXECUTIVE SUMMARY Page 12 of 12 Priced Storage Configuration Components Priced Storage Configuration 6 Sun Storage 16 Gbps FC PCIe dual-port HBAs with 12 Sun Storage 16 Gbps FC optics 2 Oracle ZFS ZS3-2 controllers (cluster configuration) 256 GB cache/memory per controller (512 GB total) 6 Sun Storage 16 Gbps FC PCIe dual-port HBAs with 12 Sun Storage 16 Gbps FC optics (3 FC HBAs and 6 FC optics per controller) 6 16 Gb FC front-end connections per controller (12 16 Gb FC front-end connections total, 12 used) 2 SAS PCIe 6 Gb 16 port adapters (1 adapter included with each controller) 4 physical SAS connections per adapter 4 logical SAS connections per physical connection 16 logical SAS connections per adapter 8 physical SAS connections per controller (32 total logical connections, 32 used) 2 SAS PCIe 6 Gb 16 port adapters (1 additional adapter per controller) 4 physical SAS connections per adapter 4 logical SAS connections per physical connection 16 logical SAS connections per adapter 8 physical SAS connections per controller (32 total logical connections, 32 connections used) 12 Sun disk shelf base each with 2 SAS I/O modules, 2 AC PSUs and 2 cooling fans GB 10K RPM 2.5 SAS-2 disk drives 1 Sun Rack II, 42U 1 Sun Rack II 10kVA PDU, single phase, 48 supported amps max
SPC BENCHMARK 1/ENERGY EXECUTIVE SUMMARY IBM CORPORATION IBM FLASHSYSTEM 840 SPC-1/E V1.14
SPC BENCHMARK 1/ENERGY EXECUTIVE SUMMARY IBM CORPORATION IBM FLASHSYSTEM 840 SPC-1/E V1.14 Submitted for Review: September 19, 2014 Submission Identifier: AE00007 EXECUTIVE SUMMARY Page 2 of 16 EXECUTIVE
SPC BENCHMARK 1 EXECUTIVE SUMMARY X-IO TECHNOLOGIES X-IO ISE 820 G3 ALL FLASH ARRAY SPC-1 V1.14
SPC BENCHMARK 1 EXECUTIVE SUMMARY X-IO TECHNOLOGIES X-IO ISE 820 G3 ALL FLASH ARRAY SPC-1 V1.14 Submitted for Review: March 10, 2015 Submission Identifier: A00155 EXECUTIVE SUMMARY Page 2 of 10 EXECUTIVE
SPC BENCHMARK 1 EXECUTIVE SUMMARY FUJITSU LIMITED FUJITSU STORAGE SYSTEMS ETERNUS DX600 S3 SPC-1 V1.14
SPC BENCHMARK 1 EXECUTIVE SUMMARY FUJITSU LIMITED FUJITSU STORAGE SYSTEMS ETERNUS DX600 S3 SPC-1 V1.14 Submitted for Review: July 25, 2014 Submission Identifier: A00146 EXECUTIVE SUMMARY Page 2 of 11 EXECUTIVE
SPC BENCHMARK 1 EXECUTIVE SUMMARY
SPC BENCHMARK 1 EXECUTIVE SUMMARY NETAPP, INC. NETAPP FAS8080 EX (ALL-FLASH FAS) SPC-1 V1.14 Submitted for Review: April 22, 2015 Submission Identifier: A00154 EXECUTIVE SUMMARY Page 2 of 10 EXECUTIVE
SPC BENCHMARK 1 EXECUTIVE SUMMARY HITACHI DATA SYSTEMS CORPORATION HITACHI UNIFIED STORAGE 150 (WITH SSDS) SPC-1 V1.13
SPC BENCHMARK 1 EXECUTIVE SUMMARY HITACHI DATA SYSTEMS CORPORATION HITACHI UNIFIED STORAGE 150 (WITH SSDS) SPC-1 V1.13 Submitted for Review: March 26, 2013 Submission Identifier: A00129 EXECUTIVE SUMMARY
SPC BENCHMARK 1 EXECUTIVE SUMMARY HUAWEI TECHNOLOGIES CO., LTD. HUAWEI OCEANSTOR 5500 V3 SPC-1 V1.14
SPC BENCHMARK 1 EXECUTIVE SUMMARY HUAWEI TECHNOLOGIES CO., LTD. HUAWEI OCEANSTOR 5500 V3 SPC-1 V1.14 Submitted for Review: April 21, 2015 Submission Identifier: A00127 EXECUTIVE SUMMARY Page 2 of 12 EXECUTIVE
SPC BENCHMARK 1 EXECUTIVE SUMMARY HITACHI DATA SYSTEMS CORPORATION HITACHI VIRTUAL STORAGE PLATFORM G1000 (WITH HITACHI ACCELERATED FLASH) SPC-1 V1.
SPC BENCHMARK 1 EXECUTIVE SUMMARY HITACHI DATA SYSTEMS CORPORATION HITACHI VIRTUAL STORAGE PLATFORM G1000 (WITH HITACHI ACCELERATED FLASH) SPC-1 V1.14 Submitted for Review: February 19, 2015 Submission
SPC BENCHMARK 1 EXECUTIVE SUMMARY HUAWEI TECHNOLOGIES CO., LTD. HUAWEI OCEANSTOR 6800 V3 SPC-1 V1.14
SPC BENCHMARK 1 EXECUTIVE SUMMARY HUAWEI TECHNOLOGIES CO., LTD. HUAWEI OCEANSTOR 6800 V3 SPC-1 V1.14 Submitted for Review: November 21, 2014 Submission Identifier: A00149 EXECUTIVE SUMMARY Page 2 of 12
SPC BENCHMARK 1 EXECUTIVE SUMMARY HUAWEI TECHNOLOGIES CO., LTD. HUAWEI OCEANSTOR S5500T SPC-1 V1.13
SPC BENCHMARK 1 EXECUTIVE SUMMARY HUAWEI TECHNOLOGIES CO., LTD. HUAWEI OCEANSTOR S5500T SPC-1 V1.13 Submitted for Review: November 12, 2012 Submission Identifier: A00122 EXECUTIVE SUMMARY Page 2 of 8 EXECUTIVE
SPC BENCHMARK 1 FULL DISCLOSURE REPORT IBM CORPORATION IBM SYSTEM STORAGE SAN VOLUME CONTROLLER V6.2 SPC-1 V1.12
SPC BENCHMARK 1 FULL DISCLOSURE REPORT IBM CORPORATION IBM SYSTEM STORAGE SAN VOLUME CONTROLLER V6.2 WITH IBM STORWIZE V7000 DISK STORAGE SPC-1 V1.12 Submitted for Review: January 30, 2012 ii First Edition
SPC BENCHMARK 1 EXECUTIVE SUMMARY IBM CORPORATION IBM STORWIZE V7000 SPC-1 V1.12. Submitted for Review: October 22, 2010 Submission Identifier: A00097
SPC BENCHMARK 1 EXECUTIVE SUMMARY IBM CORPORATION IBM STORWIZE V7000 SPC-1 V1.12 Submitted for Review: October 22, 2010 Submission Identifier: A00097 EXECUTIVE SUMMARY Page 2 of 8 EXECUTIVE SUMMARY Test
SPC BENCHMARK 1C FULL DISCLOSURE REPORT SEAGATE TECHNOLOGY LLC IBM 600GB 10K 6GBPS SAS 2.5" G2HS HYBRID SPC-1C V1.5
SPC BENCHMARK 1C FULL DISCLOSURE REPORT SEAGATE TECHNOLOGY LLC IBM 600GB 10K 6GBPS SAS 2.5" G2HS HYBRID SPC-1C V1.5 Submitted for Review: June 14, 2013 Submission Identifier: C00016 ii First Edition June
SPC BENCHMARK 1 EXECUTIVE SUMMARY 3PAR INC. 3PARINSERV T800 STORAGE SERVER SPC-1 V1.10.1
SPC BENCHMARK 1 EXECUTIVE SUMMARY 3PAR INC. 3PARINSERV T800 STORAGE SERVER SPC-1 V1.10.1 Submitted for Review: September 2, 2008 Submission Identifier: A00069 EXECUTIVE SUMMARY Page 2 of 7 EXECUTIVE SUMMARY
SPC BENCHMARK 1 EXECUTIVE SUMMARY HEWLETT PACKARD ENTERPRISE HPE 3PAR STORESERV 8450 STORAGE SYSTEM SPC-1 V1.14
SPC BENCHMARK 1 EXECUTIVE SUMMARY HEWLETT PACKARD ENTERPRISE HPE 3PAR STORESERV 8450 STORAGE SYSTEM SPC-1 V1.14 Submitted for Review: March 8, 2016 Submission Identifier: A00168 Revised: June 2, 2016 EXECUTIVE
SEAGATE 600GB 15K 12GBPS SAS 2.5" ENTERPRISE PERFORMANCE HDD/ST600MP0065 SPC-1C V1.5
SPC BENCHMARK 1C EXECUTIVE SUMMARY SEAGATE TECHNOLOGY LLC SEAGATE 600GB 15K 12GBPS SAS 2.5" ENTERPRISE PERFORMANCE HDD/ST600MP0065 SPC-1C V1.5 Submitted for Review: November 3, 2014 Submission Identifier:
SPC BENCHMARK 1 FULL DISCLOSURE REPORT IBM CORPORATION IBM SYSTEM STORAGE DS8700 RELEASE 5.1 (EASY TIER AND SSDS) SPC-1 V1.12
SPC BENCHMARK 1 FULL DISCLOSURE REPORT IBM CORPORATION IBM SYSTEM STORAGE DS8700 RELEASE 5.1 (EASY TIER AND SSDS) SPC-1 V1.12 Submitted for Review: April 13, 2010 Submission Identifier: A00092 ii First
SPC BENCHMARK 1C FULL DISCLOSURE REPORT SEAGATE TECHNOLOGY LLC IBM 600GB 10K 6GBPS SAS 2.5" SFF SLIM-HS HDD SPC-1C V1.5
SPC BENCHMARK 1C FULL DISCLOSURE REPORT SEAGATE TECHNOLOGY LLC IBM 600GB 10K 6GBPS SAS 2.5" SFF SLIM-HS HDD SPC-1C V1.5 Submitted for Review: June 14, 2013 Submission Identifier: C00015 ii First Edition
UNIFIED HYBRID STORAGE. Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment
DATASHEET TM NST6000 UNIFIED HYBRID STORAGE Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment UNIFIED The Nexsan NST6000 unified hybrid storage appliance is ideal for
SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION
SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION AFFORDABLE, RELIABLE, AND GREAT PRICES FOR EDUCATION Optimized Sun systems run Oracle and other leading operating and virtualization platforms with greater
SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION
SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION AFFORDABLE, RELIABLE, AND GREAT PRICES FOR EDUCATION Optimized Sun systems run Oracle and other leading operating and virtualization platforms with greater
SUN/Oracle WSCA Price List. Please call (877) SUN-LATG (877) 786-5284 (504) 304-2505 Or Fax (504) 617 6670 Or e-mail [email protected]
SUN/Oracle WSCA Price List Please call (877) SUNLATG (877) 7865284 (504) 3042505 Or Fax (504) 617 6670 Or email [email protected] WSCA Price List Updated January Item Item Description Named Product List Price
SPC BENCHMARK 1 EXECUTIVE SUMMARY
SPC BENCHMARK 1 EXECUTIVE SUMMARY NETAPP,INC. NETAPP FAS3170 SPC-1 V1.10.1 Submitted for Review: June 10, 2008 Submission Identifier: A00066 EXECUTIVE SUMMARY Page 2 of 7 EXECUTIVE SUMMARY Test Sponsor
EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS
EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS EMC Data Domain deduplication storage systems continue to revolutionize disk backup, archiving, and disaster recovery with high-speed, inline deduplication.
EMC VMAX3 FAMILY - VMAX 100K, 200K, 400K
SPECIFICATION SHEET EMC VMAX3 FAMILY - VMAX 100K, 200K, 400K The EMC VMAX3 TM family delivers the latest in Tier-1 scale-out multi-controller architecture with unmatched consolidation and efficiency for
EMC SYMMETRIX VMAX 20K STORAGE SYSTEM
EMC SYMMETRIX VMAX 20K STORAGE SYSTEM The EMC Virtual Matrix Architecture is a new way to build storage systems that transcends the physical constraints of all existing architectures by scaling system
EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS
EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS EMC Data Domain deduplication storage systems continue to revolutionize disk backup, archiving, and disaster recovery with high-speed, inline deduplication.
SPC BENCHMARK 1 EXECUTIVE SUMMARY HITACHI DATA SYSTEMS CORPORATION HITACHI UNIVERSAL STORAGE PLATFORM V SPC-1 V1.10.1
SPC BENCHMARK 1 EXECUTIVE SUMMARY HITACHI DATA SYSTEMS CORPORATION HITACHI UNIVERSAL STORAGE PLATFORM V SPC-1 V1.10.1 Submitted for Review: October 1, 2007 Submission Identifier: A00054 EXECUTIVE SUMMARY
EMC ISILON HD-SERIES. Specifications. EMC Isilon HD400 ARCHITECTURE
EMC ISILON HD-SERIES The rapid growth of unstructured data combined with increasingly stringent compliance requirements is resulting in a growing need for efficient data archiving solutions that can store
Intel RAID SSD Cache Controller RCS25ZB040
SOLUTION Brief Intel RAID SSD Cache Controller RCS25ZB040 When Faster Matters Cost-Effective Intelligent RAID with Embedded High Performance Flash Intel RAID SSD Cache Controller RCS25ZB040 When Faster
1. Specifiers may alternately wish to include this specification in the following sections:
GUIDE SPECIFICATION Seneca is a leading US designer and manufacturer of xvault security and surveillance solutions. The xvault product line combines our IP expertise and solution partnerships with certified
EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS
EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS EMC Data Domain deduplication storage systems continue to revolutionize disk backup, archiving, and disaster recovery with high-speed, inline deduplication.
DD670, DD860, and DD890 Hardware Overview
DD670, DD860, and DD890 Hardware Overview Data Domain, Inc. 2421 Mission College Boulevard, Santa Clara, CA 95054 866-WE-DDUPE; 408-980-4800 775-0186-0001 Revision A July 14, 2010 Copyright 2010 EMC Corporation.
Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and IBM FlexSystem Enterprise Chassis
White Paper Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and IBM FlexSystem Enterprise Chassis White Paper March 2014 2014 Cisco and/or its affiliates. All rights reserved. This document
EMC SYMMETRIX VMAX 10K
EMC SYMMETRIX VMAX 10K EMC Symmetrix VMAX 10K with the Enginuity operating environment delivers a true Tier-1 multi-controller, scale-out architecture with consolidation and efficiency for the enterprise.
IOmark- VDI. Nimbus Data Gemini Test Report: VDI- 130906- a Test Report Date: 6, September 2013. www.iomark.org
IOmark- VDI Nimbus Data Gemini Test Report: VDI- 130906- a Test Copyright 2010-2013 Evaluator Group, Inc. All rights reserved. IOmark- VDI, IOmark- VDI, VDI- IOmark, and IOmark are trademarks of Evaluator
SUN STORAGE F5100 FLASH ARRAY
SUN STORAGE F5100 FLASH ARRAY KEY FEATURES ACCELERATING DATABASE PERFORMANCE WITH THE WORLD S FASTEST SOLID- STATE FLASH ARRAY Unprecedented performance, power, and space efficiency World s first flash
EMC VMAX3 FAMILY VMAX 100K, 200K, 400K
EMC VMAX3 FAMILY VMAX 100K, 200K, 400K The EMC VMAX3 TM family delivers the latest in Tier-1 scale-out multi-controller architecture with unmatched consolidation and efficiency for the enterprise. With
An Oracle White Paper October 2013. Realizing the Superior Value and Performance of Oracle ZFS Storage Appliance
An Oracle White Paper October 2013 Realizing the Superior Value and Performance of Oracle ZFS Storage Appliance Executive Overview... 2 Introduction... 3 Delivering Superior Performance at a Lower Price...
Evaluation Report: HP Blade Server and HP MSA 16GFC Storage Evaluation
Evaluation Report: HP Blade Server and HP MSA 16GFC Storage Evaluation Evaluation report prepared under contract with HP Executive Summary The computing industry is experiencing an increasing demand for
Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure
White Paper Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure White Paper March 2014 2014 Cisco and/or its affiliates. All rights reserved. This
EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS
EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS EMC Data Domain deduplication storage systems continue to revolutionize disk backup, archiving, and disaster recovery with high-speed, inline deduplication.
New Cluster-Ready FAS3200 Models
New Cluster-Ready FAS3200 Models Steven Miller Senior Technical Director and Platform Architect NetApp recently introduced two new models in the FAS3200 series: the FAS3220 and the FAS3250. Our design
IOmark- VDI. HP HP ConvergedSystem 242- HC StoreVirtual Test Report: VDI- HC- 150427- b Test Report Date: 27, April 2015. www.iomark.
IOmark- VDI HP HP ConvergedSystem 242- HC StoreVirtual Test Report: VDI- HC- 150427- b Test Copyright 2010-2014 Evaluator Group, Inc. All rights reserved. IOmark- VDI, IOmark- VM, VDI- IOmark, and IOmark
SUN ORACLE EXADATA STORAGE SERVER
SUN ORACLE EXADATA STORAGE SERVER KEY FEATURES AND BENEFITS FEATURES 12 x 3.5 inch SAS or SATA disks 384 GB of Exadata Smart Flash Cache 2 Intel 2.53 Ghz quad-core processors 24 GB memory Dual InfiniBand
Power Efficiency Comparison of Enterprise-Class Blade Servers and Enclosures
Power Efficiency Comparison of Enterprise-Class Blade Servers and Enclosures A Dell Technical White Paper John Beckett, Robert Bradfield, and the Dell Server Performance Analysis Team THIS WHITE PAPER
Cisco-EMC Microsoft SQL Server Fast Track Warehouse 3.0 Enterprise Reference Configurations. Data Sheet
Cisco-EMC Microsoft SQL Fast Track Warehouse 3.0 Enterprise Reference Configurations Data Sheet May 2011 Raghunath Nambiar Access and Virtualization Business Unit Introduction The Microsoft SQL Fast Track
Scaling from Datacenter to Client
Scaling from Datacenter to Client KeunSoo Jo Sr. Manager Memory Product Planning Samsung Semiconductor Audio-Visual Sponsor Outline SSD Market Overview & Trends - Enterprise What brought us to NVMe Technology
WHITE PAPER Improving Storage Efficiencies with Data Deduplication and Compression
WHITE PAPER Improving Storage Efficiencies with Data Deduplication and Compression Sponsored by: Oracle Steven Scully May 2010 Benjamin Woo IDC OPINION Global Headquarters: 5 Speen Street Framingham, MA
Dynamically unify your data center Dell Compellent: Self-optimized, intelligently tiered storage
Dell Fluid Data architecture Dynamically unify your data center Dell Compellent: Self-optimized, intelligently tiered storage Dell believes that storage should help you spend less while giving you the
HADOOP ON ORACLE ZFS STORAGE A TECHNICAL OVERVIEW
HADOOP ON ORACLE ZFS STORAGE A TECHNICAL OVERVIEW 757 Maleta Lane, Suite 201 Castle Rock, CO 80108 Brett Weninger, Managing Director [email protected] Dave Smelker, Managing Principal [email protected]
Vault 8000 Series. Product Overview KEY BENEFITS
Vault 8000 Series Product Overview The demands of a data-driven business require a fundamentally new approach to storage with an integrated combination of high-performance hardware and adaptive, scalable
Scalable. Reliable. Flexible. High Performance Architecture. Fault Tolerant System Design. Expansion Options for Unique Business Needs
Protecting the Data That Drives Business SecureSphere Appliances Scalable. Reliable. Flexible. Imperva SecureSphere appliances provide superior performance and resiliency for demanding network environments.
HP reference configuration for entry-level SAS Grid Manager solutions
HP reference configuration for entry-level SAS Grid Manager solutions Up to 864 simultaneous SAS jobs and more than 3 GB/s I/O throughput Technical white paper Table of contents Executive summary... 2
EMC ISILON NL-SERIES. Specifications. EMC Isilon NL400. EMC Isilon NL410 ARCHITECTURE
EMC ISILON NL-SERIES The challenge of cost-effectively storing and managing data is an ever-growing concern. You have to weigh the cost of storing certain aging data sets against the need for quick access.
4 Bay External Hard Drive Array RAID Tower esata USB 3.0 Enclosure. StarTech ID: SAT3540U3ER
4 Bay External Hard Drive Array RAID Tower esata USB 3.0 Enclosure StarTech ID: SAT3540U3ER The SAT3540U3ER 4-Drive USB 3.0/eSATA to 3.5" SATA RAID Enclosure is a high-performance external RAID storage
EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS
EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS EMC Data Domain deduplication storage systems continue to revolutionize disk backup, archiving, and disaster recovery with high-speed, inline deduplication.
Appendix 3. Specifications for e-portal
Appendix 3. Specifications for e-portal 1. e-portal H/W and S/W No Equipment Specification Unit Q'ty 1 Web Server for users and administrator 2 WAS Server 3 LMS Server 4 DB Server 4U Rack Type 8 Core Intel
3 Port PCI Express 2.0 SATA III 6 Gbps RAID Controller Card w/ msata Slot and HyperDuo SSD Tiering
3 Port PCI Express 2.0 SATA III 6 Gbps RAID Controller Card w/ msata Slot and HyperDuo SSD Tiering StarTech ID: PEXMSATA343 The PEXMSATA343 3-Port PCI Express 2.0 SATA Card with HyperDuo adds an internal
IBM System Storage DS3950 Express
DS3950 Express Manage growth, complexity and risk with scalable, high-performance storage Highlights Simplify storage infrastructure with 8 Gbps Fibre Channel interfaces Leverage mixed-host interfaces
MESOS CB220. Cluster-in-a-Box. Network Storage Appliance. A Simple and Smart Way to Converged Storage with QCT MESOS CB220
MESOS CB220 Cluster-in-a-Box Network Storage Appliance A Simple and Smart Way to Converged Storage with QCT MESOS CB220 MESOS CB220 A Simple and Smart Way to Converged Storage Tailored for SMB storage
All-Flash Storage Solution for SAP HANA:
All-Flash Storage Solution for SAP HANA: Storage Considerations using SanDisk Solid State Devices WHITE PAPER 951 SanDisk Drive, Milpitas, CA 95035 www.sandisk.com Table of Contents Preface 3 Why SanDisk?
Cisco Unified Computing System and EMC VNXe3300 Unified Storage System
Cisco Unified Computing System and EMC VNXe3300 Unified Storage System An Ideal Solution for SMB Server Consolidation White Paper January 2011, Revision 1.0 Contents Cisco UCS C250 M2 Extended-Memory Rack-Mount
WHITE PAPER Addressing Enterprise Computing Storage Performance Gaps with Enterprise Flash Drives
WHITE PAPER Addressing Enterprise Computing Storage Performance Gaps with Enterprise Flash Drives Sponsored by: Pliant Technology Benjamin Woo August 2009 Matthew Eastwood EXECUTIVE SUMMARY Global Headquarters:
The Future of Computing Cisco Unified Computing System. Markus Kunstmann Channels Systems Engineer
The Future of Computing Cisco Unified Computing System Markus Kunstmann Channels Systems Engineer 2009 Cisco Systems, Inc. All rights reserved. Data Centers Are under Increasing Pressure Collaboration
INDIAN INSTITUTE OF TECHNOLOGY KANPUR Department of Mechanical Engineering
INDIAN INSTITUTE OF TECHNOLOGY KANPUR Department of Mechanical Engineering Enquiry No: Enq/IITK/ME/JB/02 Enquiry Date: 14/12/15 Last Date of Submission: 21/12/15 Formal quotations are invited for HPC cluster.
G-RAID 2 - Award Winning RAID 0 Storage System
G-RAID 2 - Award Winning RAID 0 Storage System G-Technology (G-Tech) manufactures the industry's most comprehensive line of external disk storage solutions designed for professional content creation applications.
Scalable. Reliable. Flexible. High Performance Architecture. Fault Tolerant System Design. Expansion Options for Unique Business Needs
Protecting the Data That Drives Business SecureSphere Appliances Scalable. Reliable. Flexible. Imperva SecureSphere appliances provide superior performance and resiliency for demanding network environments.
Maximum performance, minimal risk for data warehousing
SYSTEM X SERVERS SOLUTION BRIEF Maximum performance, minimal risk for data warehousing Microsoft Data Warehouse Fast Track for SQL Server 2014 on System x3850 X6 (95TB) The rapid growth of technology has
PSAM, NEC PCIe SSD Appliance for Microsoft SQL Server (Reference Architecture) September 11 th, 2014 NEC Corporation
PSAM, NEC PCIe SSD Appliance for Microsoft SQL Server (Reference Architecture) September 11 th, 2014 NEC Corporation 1. Overview of NEC PCIe SSD Appliance for Microsoft SQL Server Page 2 NEC Corporation
Oracle Database Deployments with EMC CLARiiON AX4 Storage Systems
Oracle Database Deployments with EMC CLARiiON AX4 Storage Systems Applied Technology Abstract This white paper investigates configuration and replication choices for Oracle Database deployment with EMC
27 22 00 Data Communications Hardware 27 22 16 Data Communications Storage and Backup 27 22 19 Data Communications Servers
Pivot3 has over 1200 customers across the globe that rely on purpose-built Pivot3 appliances for highcapacity video surveillance and high-iop virtual desktop environments. The company is the leading supplier
Acer Hitachi AS2040 specifications
Product overview The Acer Hitachi AS2040 is a reliable and robust storage system designed with the small and mid-sized business in mind. Designed with enterprise-class features and simplified management
HP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN
HP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN Table of contents Executive summary... 2 Introduction... 2 Solution criteria... 3 Hyper-V guest machine configurations...
Network Attached Storage Common Configuration for Entry-Level
Common Configuration for Entry-Level ATTACHMENT VI Product Attribute Entry Level -- Description RFI Response Main Memory (Base): 4 Internal Storage Controller: Fiber Channel RAID Controller: Dual redundant
FAS6200 Cluster Delivers Exceptional Block I/O Performance with Low Latency
FAS6200 Cluster Delivers Exceptional Block I/O Performance with Low Latency Dimitris Krekoukias Systems Engineer NetApp Data ONTAP 8 software operating in Cluster-Mode is the industry's only unified, scale-out
Solutions Brief. Unified All Flash Storage. FlashPoint Partner Program. Featuring. Sustainable Storage. S-Class Flash Storage Systems
FlashPoint Partner Program Solutions Brief Unified All Flash Storage Featuring Sustainable Storage S-Class Flash Storage Systems E-Class Flash Storage Systems Gemini Flash Storage Systems FlashPoint Partner
SUN ORACLE DATABASE MACHINE
SUN ORACLE DATABASE MACHINE FEATURES AND FACTS FEATURES From 2 to 8 database servers From 3 to 14 Sun Oracle Exadata Storage Servers Up to 5.3 TB of Exadata QDR (40 Gb/second) InfiniBand Switches Uncompressed
4 Bay External Hard Drive Array RAID Tower esata USB 3.0 Enclosure. StarTech ID: SAT3540U3ER
4 Bay External Hard Drive Array RAID Tower esata USB 3.0 Enclosure StarTech ID: SAT3540U3ER The SAT3540U3ER 4-Drive USB 3.0/eSATA to 3.5" SATA RAID Enclosure is a high-performance external RAID storage
534479 Great Northern Consulting, LLC Original Price list 6.27.14. Manufacturer Description No Great Northern Consulting - Professional Services List
534479, LLC Original Price list 6.27.14 SYSTEMS ADMIISTRATIO - Professional Services List Systems Administrator 3 GCS-SA3 Provides Unix/Linux systems administration services for client. Three years systems
ORACLE BIG DATA APPLIANCE X3-2
ORACLE BIG DATA APPLIANCE X3-2 BIG DATA FOR THE ENTERPRISE KEY FEATURES Massively scalable infrastructure to store and manage big data Big Data Connectors delivers load rates of up to 12TB per hour between
SAN TECHNICAL - DETAILS/ SPECIFICATIONS
SAN TECHNICAL - DETAILS/ SPECIFICATIONS Technical Details / Specifications for 25 -TB Usable capacity SAN Solution Item 1) SAN STORAGE HARDWARE : One No. S.N. Features Description Technical Compliance
NetScaler SD-WAN. Securely delivers optimal application performance over any network
Securely delivers optimal application performance over any network NetScaler SD-WAN increases the performance and reliability of traditional enterprise applications, SaaS applications and virtual desktops
ntier Verde Simply Affordable File Storage
ntier Verde Simply Affordable File Storage Current Market Problems Data Growth Continues Data Retention Increases By 2020 the Digital Universe will hold 40 Zettabytes The Market is Missing: An easy to
Spare Parts Price List (Sorted by Orderable Marketing Part Number)
Spare s (Sorted by ) November 3, 2015 Important note: Spare parts fall into two categories: 1) In Production Spares: Spare parts associated with current systems that are readily available; and 2) Out of
FUJITSU Enterprise Product & Solution Facts
FUJITSU Enterprise Product & Solution Facts shaping tomorrow with you Business-Centric Data Center The way ICT delivers value is fundamentally changing. Mobile, Big Data, cloud and social media are driving
Cisco UCS B-Series M2 Blade Servers
Cisco UCS B-Series M2 Blade Servers Cisco Unified Computing System Overview The Cisco Unified Computing System is a next-generation data center platform that unites compute, network, storage access, and
NEC EXPRESS5800/R320c-E4 Configuration Guide
NEC EXPRESS5800/R320c-E4 Configuration Guide VMware model Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure
Evaluation Report: Accelerating SQL Server Database Performance with the Lenovo Storage S3200 SAN Array
Evaluation Report: Accelerating SQL Server Database Performance with the Lenovo Storage S3200 SAN Array Evaluation report prepared under contract with Lenovo Executive Summary Even with the price of flash
Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server
Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Strong Performance and Cluster
nappliance Network Virtualization Gateways
nappliance Network Virtualization Gateways The nappliance MNV Gateway appliance family supports wide range of models, each of the models are specifically designed to meet the unique technical requirements
PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector
PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector StarTech ID: PEXSAT34SFF The PEXSAT34SFF PCI Express SATA Controller Card enables 4 AHCI SATA III connections to
HUAWEI TECHNOLOGIES CO., LTD. HUAWEI FusionServer X6800 Data Center Server
HUAWEI TECHNOLOGIES CO., LTD. HUAWEI FusionServer X6800 Data Center Server HUAWEI FusionServer X6800 Data Center Server Data Center Cloud Internet App Big Data HPC As the IT infrastructure changes with
DATA WAREHOuSIng. 11.12 eb 7378. Data Warehouse 6700
Teradata Active Enterprise Data Warehouse 6700 Active Data Warehousing Platform for Teradata Solutions In today s fast-paced, ever-changing competitive environment, your data warehouse must provide higher
Evaluation Report: Supporting Microsoft Exchange on the Lenovo S3200 Hybrid Array
Evaluation Report: Supporting Microsoft Exchange on the Lenovo S3200 Hybrid Array Evaluation report prepared under contract with Lenovo Executive Summary Love it or hate it, businesses rely on email. It
An Oracle White Paper November 2010. Backup and Recovery with Oracle s Sun ZFS Storage Appliances and Oracle Recovery Manager
An Oracle White Paper November 2010 Backup and Recovery with Oracle s Sun ZFS Storage Appliances and Oracle Recovery Manager Introduction...2 Oracle Backup and Recovery Solution Overview...3 Oracle Recovery
Configuration Guide February 2015
Configuration Guide February 2015 1 For the latest version of this document, please go to: http://www.overlandstorage.com//pdfs/snapserver_xsr_config_guide.pdf 2015 Overland Storage. All trademarks and