Contact Information: 4031-0001 Electrical Connection Kit for CL Series Constant Wattage Temptrace for Low Temperature Maintenance.



Similar documents
NELSON HEAT TRACING SYSTEMS

FAK-7HTS High Temperature Tubing Bundle End Seal Kit INSTALLATION PROCEDURES

Instruction Manual. Cable Splicing. Models , HDF1, HDF SS1

KSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES

RayClic Connection System Installation Instructions

RayClic Connection System Installation Instructions

BILLET HEADLAMP WITH SHORT/TALL MOUNTS

Universal Vehicle Power Supply 9007AX01. Installation Instructions

5800 Temperature Sensor Cable Assembly

XL PREMIUM OIL COOLER KIT

Heat Tracing Sales Mt. Airy, Maryland Installation Instructions

Heating Cable. Construction

User s Manual. BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide ( )

Installation Instructions DTS-HAZ DTS-HAZ-DC. for Use with Self-Regulating & Constant Wattage Heating Cables

NOTE WARNING. Electric Leveling Motor Brake Replacement Instructions ELECTRIC LEVELING MOTOR BRAKE REPLACEMENT INSTRUCTIONS. Content.

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

with installation dynafact boost GAUGE this manual is for use with systems

SCTK INSTALLATION PROCEDURES. Splice Connection Termination Kit. SCTK-1D for BSX, RSX, VSX SCTK-2D for KSX, HTSX SCTK-3D for HPT, FP

3M Scotchcast Mine and Portable Cable Splice Kit

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.

CUSTOM AUXILIARY FORWARD LIGHTING KIT

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Self-Regulating Low Temperature Heating Cable

PDI-P10LCD Pre-Tensioned Swivel Cartridge

2178-S Fiber Optic Splice Case

AM/FM ANTENNA KIT (TOUR-PAK MOUNT)

Ocean Engineering Technical Data Sheet Stuffing Tubes

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

INSTALLATION INSTRUCTIONS

jbs nfb INSTALLATION INSTRUCTIONS AND OWNERS MANUAL Mechanical Steering for Inboard, Outboard, and Sterndrive Powered Vessels

SECURITY SYSTEM SMART SIREN KIT

Model 111 Mass Flow Instruments

TECHNICAL GUIDE. For Self-Shielded Guns - 300, 400 and 500 amp SAFETY AND WARRANTY INFORMATION INSTALLATION MAINTENANCE GUIDE TECHNICAL DATA OPTIONS

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

SELF-REGULATING PIPE TRACING HEATER CABLE

LED Wiring and Connections

Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N

Connecting the Channel A

TELECOM The Newsmagazine of the Industrial Telecommunications Association, Inc.

Ignition Coil Sealing Instructions Revision 1.0

73 Chevy C10 Ammeter to Volt Gauge Conversion Mark and Michael Olson 2013 Rev 1.0

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

AMPSEAL* Automotive Plug Connector and Header Assembly

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

Spreader Light Bulb Replacement Instructions

Tech Bulletin. Hose / Cord Replacement and Required Wraps. Series RT

WarmTrace TM INSTALLATION INSTRUCTIONS. Systems for Hot Water Temperature Maintenance. Systems for Hot Water Temperature Maintenance

OVEN PARTS For Models:GSC308PJB05, GSC308PJQ05, GSC308PJT05, GSC308PJS05 (Black) (White) (Biscuit) (Black Stainless)

EH-20 20m antenna. By VE3RGW

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Operating Instructions

Installation Instructions

Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

Assembly Instruction CAI- Connector with universal Endbell

Malibu Monte Carlo El Camino

UNIT 7: PLUMBING KEY CONCEPTS. 1. Identify tools for plumbing. 2. Location of shutoff valves for the main and individual fixtures

USA: 866.LAWSON4U ( ) Canada: lawsonproducts.com. Electrical Industrial and Fleet Solutions

TMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations

Installation & Weatherproofing Guide for ENCOM Broadband Radios


Your safety and the safety of others are very important.

DTS-HAZ DTS-HAZ-DC. Installation Instructions. for use with Self-Regulating, Constant Wattage & Mineral Insulated Electric Heating Cables

Reasons for reissue are in Section 6, REVISION SUMMARY.

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV Kit Number. Models. Additional Parts Required. Kit Contents

Co-location Interconnect Power Panel (CIPP) Installation Guide

A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION

MCR1900 Media Converter 19-Slot Chassis

Document number RS-PRD Revision 05 Date 20/10/2009 Page 1/30

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

ASX7-4-IOM-7 J

SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT

SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT

Mounting Plate / Screwdriver. Alignment Stickers Screws / Desiccant Bag / Double-sided Tape / Rubber Seal Plug / Rubber Washer

Determine the desired location fixture and center the coaxial cord location to the electrical box.

IOM SERIES 820-E/P Electro-Pneumatic Positioner

Predator. Sewer Cleaning Hose Products

SDX Submersible Depth Transmitter User Manual

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Assembly Guide FOR LED NEON FLEX

Elecraft K3 KPA3 Power Connector Replacement Revision A Review, April 16, 2012 Copyright 2012, Elecraft, Inc. All Rights Reserved

Step 1. Item 6. Item 1

INSTRUCTIONS FOR THE INSTALLATION AND OPERATION OF ACTIVATOR II

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

BILLET HEADLAMP SHELL

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

AMX300 DirectConnect Mixing Valve Kits

Electric Heat Tracing INSTALLATION PROCEDURES

- power windows - alarm system - electric door mirror control - door warning light - central locking - seat memory

Installation Instructions For Slider Casement Air Conditioners

INSTALLATION GUIDE. APPLICATION LENGTH MODEL YR PART # Bestop PART #

USE & CARE MANUAL. Non-Metallic Electric Water Heater. Residential Electric Models Gallon Capacity

Slide the new steering column shaft through the steering column from the driver compartment.

DVD-60C The Seven Sins of Wire Harness Assembly

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide

AM/FM ANTENNA RELOCATION KIT

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

Transcription:

Technical Data Sheet & Installation Instructions for 4031-0001 Electrical Connection Kit for CL Series Constant Wattage Temptrace for Low Temperature Maintenance Bulletin CL-II Contact Information: Parker Hannifin Corporation Parflex Division 1300 North Freedom Street Ravenna, OH 44266 phone 330 296 2871 fax 330 296 6747 www.parker.com/pfd 4031-0001 Electrical Connection Kit for CL Series Constant Wattage Temptrace for Low Temperature Maintenance Scope Description: Parker electrical connection kits are universal all-in-one connection kits for making the electrical connections (input power, splice, input power splice, and termination) for Parker electric trace tubing bundles. The kits contain all the necessary components and hardware to make one input connection, one splice connection or one input power splice connection as well as two termination connections. The connection kits are designed for use in ordinary locations and Class I, Division 2, Groups B, C, and D; Class II, Division 2, Groups F and G; Class III, Divisions 1 and 2 hazardous locations. Bill of Materials (1) Connection Box (1) Connection Box Gasket (1) Connection Box Cover (1) Mounting Bracket (1) 3/4" Locknut (1) 3/4" Pipe Plug Approvals (1) Electric Trace caution sticker (1) 2.8 oz Black RTV Sealant (1) Bracket Assembly (2) Connector unions (2) Heating cable grommets (2) Plastic cable ties (2) Non-insulated butt splice (12-10 AWG) (2) Non-insulated butt splice (16-14 AWG) (2) Heater termination boots (1) Roll 3/4" wide temperature tape FM - Factory Mutual Approved Ordinary Locations Hazardous (Classified) Locations Class I, Division 2, Groups B, C and D Class II, Division 2, Groups F and G Class III, Divisions 1 and 2 WARNING USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems. Ground Fault Equipment Protection Devices (GFEPDs): The IEEE standards (515-2004) for heating cables requires the use of GFEPDs with a nominal 30 miliampere trip level for piping systems in classified areas, those areas requiring a high degree of maintenance, or which may be exposed to physical abuse or corrosive atmospheres. Offer of Sale The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated in the detailed Offer of Sale elsewhere in this document or available at. 2012 Parker Hannifin Corporation Bulletin CL-II Mar 2012 Assembled Input Power Connection Kit Assembled Input Power and Splice Connection Kit Assembled Termination Connection Kit

Input Power Connection Terminal Connection The IEEE standards (515-2004) for heating cables requires the use of GFEPDs with a nominal 30 milliampere trip level for piping systems in classified areas, those areas requiring a high degree of maintenance, or which may be exposed to physical abuse or corrosive atmospheres. When cutting jacket and insulation, take great care not to cut into heating cable. Cutting heating cable may cause electrical 1 4b 4c 4d Using a sharp knife carefully cut and remove approximately 8" of jacket, insulation and heat transfer foil from product exposing process tube(s) and heating cable. 1" of inner jacket. Take care not to cut into bus wires. Remove excess nichrome wire and separate bus wires. Cut one bus wire 1/4" from end. Heating zones are located between nichrome wire/bus wire connections. To ensure proper installation, nichrome wire/bus wire connection must be outside of bundle as near to bundle end as possible. Ensure only one nichrome wire/bus wire connection is located outside bundle. 2a Nichrome wire/bus wire connections may be located at either 12", 18" or 24" intervals along the heating cable. Locate nichrome wire/bus wire connection as follows: Using thumb and index finger, move down heating cable to locate nichrome wire/bus wire connection. (Connection is identified by an indentation along one side of heating cable.) 5 6 Fill terminating boot with RTV sealant. Separate heating cable bus wires from each and carefully slide termination boot over wires. 7 Secure termination boot with high temperature tape. 2b If nichrome wire/bus wire connection can t be felt, continue cutting back jacket, insulation and heat transfer foil until found. It may be necessary to cut back jacket 24" to find connection. 3 4 8 Cut and remove tube and leaving approximately 2 2-1/2" of tube and terminate with appropriate tube fitting or connection (not provided). 9 Install SK-612 kit to re-insulate bundle end. Hold bracket in place on product 1/2" beyond cut section and install cable ties. Attach connection box to bracket with connector union and locknut. Position box as required. 2 Parker Hannifin Corporation 11 Parker Hannifin Corporation

Terminal Connection When cutting jacket and insulation, take great care not to cut into heating cable. Cutting heating cable may cause electrical 1 Heating zones are located between nichrome wire/bus wire connections. Using a sharp knife, carefully cut and remove approximately 8" of jacket, insulation and heat transfer foil from product exposing process tube(s) and heating cable. Nichrome wire/bus wire connections may be located at either 12", 18" or 24" intervals along the heating cable. Input Power Connection (Continued) Either a hot air gun or propane torch may be used when heating heat shrinkable tube. A wide tipped flame must be used to prevent burning tube. When using a torch, keep flame moving to avoid scorching. 5 Place heat shrinkable tube over heating cable (if heating cable does not have braid and over jacket) and using heat gun or torch, gently heat tube until it shrinks. 6 Feed heating cable through cap, washer and oval hole grommet. When cutting heat shrinkable tube or over jacket, take care not to cut into wire braid. Cutting wire braid or bus wires may cause electrical 7a 7b To ensure proper installation, nichrome wire/bus wire connection must be outside of bundle as near to bundle end as possible. Ensure only one nichrome wire/bus wire connection is located outside bundle. 2a Locate nichrome wire/bus wire connection as follows: Using thumb and index finger, move down heating cable to locate nichrome wire/bus wire connection. (Connection is identified by an indentation along one side of heating cable.) 2b If nichrome wire/bus wire connection can t be felt, continue cutting back jacket, insulation and heat transfer foil until found. It may be necessary to cut back jacket 24" to find connection. Prepare heating cable for electrical leads as follows: 2-1/2" of over jacket or heat shrink tube. Take care not to cut into wire braid. Separate wire braid from end of heating cable. Do not cut wire braid. 3 4a When cutting heating cable inner jacket, take care not to cut into bus wires. Cutting bus wires may cause electrical 7c 7d When cutting heating cable inner jacket, take care not to cut into bus wires. Cutting bus wires may cause electrical Cut heating cable approximately 2 2-1/2" from bundle end. Isolate heating cable bus wires as follows: 1-1/2" of over jacket (if applicable) and wire braid. Twist wire braid to form a ground wire. Crimp small terminal to end of wire braid. 10 Parker Hannifin Corporation 3 Parker Hannifin Corporation

Input Power Connection (Continued) Input Power and Splice Connection (Continued) 7e 7f 7g 12 13 For input power and splice connections, install power leads in remaining connection box opening and connect to both sets of heating cable bus wires. (Not shown.) 1-1/2" of inner jacket. Take care not to cut into bus wires. Remove excess nichrome wire and separate bus wires. Strip jacket from each bus wire approximately 1/4" from end. Insert remaining heating cable through second connector union and tighten securely. For splice connection only (no power leads required) insert stripped bus wires of heating cable into terminal ends of second heating element and crimp. 8 9 Tighten cap securely to connector union to ensure a watertight connection. Failure to do this may cause electrical 14 15 16 Crimp one large terminal to each bus wire. Insert heating cable with leads through connector union and tighten cap securely. Using high temperature tape wrap and insulate crimp terminals. Using high temperature tape, secure heating cables to bare tubing section. Install plug into remaining connection box port. 10 11 12 17 18 Install power leads (not furnished) through connection box opening and connect to heating cable leads with crimp terminals. Using high temperature tape provided, wrap and insulate crimp terminals. Install gasket and cover and tighten screws securely. Install gasket and cover and tighten screws securely. Attach sticker to connection box. 4 Parker Hannifin Corporation 9 Parker Hannifin Corporation

Input Power and Splice Connection (Continued) Input Power Connection (Continued) 9d 9e 13 14 When cutting heating cable inner jacket, take care not to cut into bus wires. Cutting bus wires may cause electrical When pushing insulation back inside bundle end, take care not to damage heating element. Damage to heating element may cause electrical Crimp small terminal to end of wire braid. 1-1/2" of inner jacket. Take care not to cut into bus wires. Insert plug into remaining opening of connection box. Attach sticker to connection box. 9f 9g 9h Prepare remaining heating cable the same as in Steps 9a - 9g, only do not attach terminals to wires. 15 Push thermal insulation, heat transfer foil and polyester tape inside bundle end approximately 1/4", and seal with RTV sealant. Remove excess nichorome wire and separate bus wires. Strip jacket from each bus wire approximately 1/4" from end. 10 11 Tighten cap securely to connector to ensure a watertight connection. Failure to do so may cause electrical Crimp one large terminal to each bus wire. Insert heating cable with leads through connector union and tighten securely. 8 Parker Hannifin Corporation 5 Parker Hannifin Corporation

Input Power and Splice Connection Input Power and Splice Connection (Continued) The IEEE standards (5-15-2004) for heating cables requires the use of GFEPDs with a nominal 30 milliampere trip level for piping systems in classified areas, those areas requiring a high degree of maintenance, or which may be exposed to physical abuse or corrosive atmospheres. When cutting jacket and insulation, take great care not to cut into heating cable. Cutting heating cable may cause electrical 1 Either a hot air gun or propane torch may be used when heating heat shrinkable tube. A wide tipped flame must be used to prevent burning tube. When using a torch, keep flame moving to avoid scorching. 5 6 Using a sharp knife carefully cut and remove approximately 8" of jacket, insulation and heat transfer foil from product exposing process tube(s) and heating cable. Place heat shrinkable tubes over both heating cables (if heating cable does not have braid and over jacket) and using heat gun or torch, gently heat tubes until they shrink. Attach connection box to bracket with connector union and locknut. Position box as shown. Heating zones are located between nichrome wire/bus wire connections. To ensure proper installation, nichrome wire/bus wire connection must be outside of bundle as near to bundle end as possible. Ensure only one nichrome wire/bus wire connection is located outside bundle. 2a 8 7 When cutting heat shrinkable tube or over jacket, take care not to cut into wire braid. Cutting wire braid or bus wires may cause electrical Nichrome wire/bus wire connections may be located at either 12", 18" or 24" intervals along the heating cable. Locate nichrome wire/bus wire connection as follows: Using thumb and index finger, move down heating cable to locate nichrome wire/bus wire connection. (Connection is identified by an indentation along one side of heating cable.) Install remaining connector union in connection box. Feed each heating cable through a cap, washer and grommet. 2b If nichrome wire/bus wire connection can t be felt, continue cutting back jacket, insulation and heat transfer foil until found. It may be necessary to cut back jacket 24" to find connection. 3 4 9a 9b 9c Hold bracket in place on product end 1/2" beyond cut section and install cable ties. Connect tubes together with Parker A-LOK (type SC) or Parker CPI (type HBZ) tube union (not furnished) and secure according to manufacturer s recommendations. Prepare heating cable for electrical leads on one heating cable only as follows: 2-1/2" of over jacket or heat shrink tube. Take care not to cut into wire braid. Separate wire braid from end of heating cable. Do not cut wire braid. Twist wire braid to form a grounding wire. 6 Parker Hannifin Corporation 7 Parker Hannifin Corporation