Residential Tenancy (Smoke Alarms) Act 2012 and Residential Tenancy (Smoke Alarms) Regulations 2012



Similar documents
Smoke Alarm Legislation Frequently Asked Questions

Smoke Alarm Legislation

Smoke Alarms. New smoke alarm requirements for existing buildings from 1 May Introduction. Advisory note March 2006

What you need to know about. Smoke alarms for residential buildings

SMOKE ALARMS CLASS 1A BUILDINGS

FIRE SAFETY INFORMATION FACT SHEET

TEMPORARY ACCOMMODATION

LANDLORD INSTRUCTION FORM

Home Owners Guide to Smoke Alarm Safety

Practice Note

SUBCHAPTER F. SMOKE ALARMS AND FIRE EXTINGUISHERS

DOMESTIC SMOKE ALARMS

Black River-Matheson Fire Department

Residential Tenancy Agreement

Smoke Alarms prhp prhp

PUBLIC Law, Chapter 162 LD 550, item 1, 124th Maine State Legislature An Act To Protect Maine Residents from Home Fires and Carbon Monoxide

Minimum Housing and Health Standards

NO FALSE ALARMS BYLAW A BYLAW OF THE CITY OF VICTORIA

FIRE SAFETY REQUIREMENTS

Danville, IN Code of Ordinances CHAPTER 90: ALARM SYSTEMS, SMOKE DETECTORS AND THE LIKE. Alarm Systems. Smoke Detectors. Key and Data Storage Boxes

In simple terms your return on investment of renting out a property is affected by two main things: rental income and your expenses.

The Smoke and Carbon Monoxide Alarm (England) Regulations 2015

Your Questions Answered

SMOKE ALARM MAINTENANCE PROGRAM

Guidance Sheet : Legislative Requirements for Rented Properties

Public Comment Draft - Health & Safety Act, Stage 1 Model Regulations

Queensland Development Code Mandatory Part 6.1 Commissioning and maintenance of fire safety installation

Residential Tenancies Act 1995

Public Health Association of Australia: Policy-at-a-glance Smoke Alarms in Residential Housing Policy

1. Landlord & Tenant Responsibility for Residential Premises

Introduction 1. Accommodation 2. Safety and Household Furnishings 3. Responsibilities 4. Taxation 5. Insurance 6. Rental 7.

1. Do your research. Speak to local letting agents. They can provide great insights.

SMOKE ALARM MAINTENANCE PROGRAM

MP 5.7 RESIDENTIAL SERVICES BUILDING STANDARD

Residential Tenancies and Rooming Accommodation Amendment Bill 2011

Landlord s Guide to Letting Residential Property

Residential Tenancies Act A Quick Guide

Residential tenancy agreement

Home Warranty Insurance Claim Form

2015 No. XXXX ENERGY, ENGLAND HOUSING, ENGLAND. The Smoke and Carbon Monoxide Alarm (England) Regulations 2015

Office of the Fire Marshal MAINTENANCE OF SMOKE ALARMS OFM-TG July 1998 GUIDELINE

Housing Assistance Payment Landlord Information Leaflet

Property, Stock and Business Agents Regulation 2014

Asbestos Removal and Assessor Licensing Information

This guide is aimed to help you consider the right choices before adding new or further buy to let property to your investment portfolio.

Government of Western Australia Department of Commerce. You and your. property manager

ALARM SYSTEMS INFORMATION & REQUIREMENTS

When you make a holiday rental booking using Wotusee.com the following terms and conditions apply.

The Types of Standard 2 Guidance on the Standards 2 Changes to Legislation 2

Asbestos removal and licensing

ADVISORY NOTES for FIRE SAFETY MANAGEMENT TOOL FOR OWNER/OCCUPIERS

Application Guide HMOs

A clear, impartial guide to. Renting a property. Tenant Moving in Checklist. rics.org/usefulguides

Landlord Insurance. Summary of cover

Requirements for Smoke/Carbon Monoxide & Fire Extinguisher Certification

Landlord Insurance. Summary of cover. October _ACLD0520ZB_BRO_A5.indd 1 23/10/ :20

Relationship Details outside Australia

Compliance Schedules and Building Warrant of Fitness

How To Get A Job In A Police Station

Student Homes Guide for Landlords 2014/2015

AGENCY AGREEMENT. Between 3Keys Limited company registration number of Town End Doncaster DN5 9AG Postcode..

Roy Cooper North Carolina Attorney General

Application to become an Education Queensland International Homestay Provider

Province of British Columbia Guide 6: The Role and Responsibilities of Tenants and Landlords in Stratas

GOVERNMENT REGIONAL OFFICERS HOUSING. Security Policy. October 2009

Queensland COMMUNITY AMBULANCE COVER ACT 2003

Residential Tenancies Landlord & Tenant Obligations

Dated (1) Waverley Borough Council (2) [NAME OF OCCUPIER] Solar Agreement. relating to [ADDRESS OF PROPERTY]

Hamilton City Council provides housing throughout Hamilton for older people living alone or as a couple who are eligible and require long-term

UNIVERSITY OF WASHINGTON SHORT TERM RESIDENTIAL LEASE UNDER 12 MONTHS & UNDER $10,000.00

RHODE ISLAND DIVISION OF STATE FIRE MARSHAL

IMPORTANT INFORMATION FOR LANDLORDS

Astute Property Management

Visual Smoke Alarm Subsidy Program

SELF-STORAGE SPACE RENTAL AGREEMENT

INFORMATION BULLETIN REPAIRS AND MAINTENANCE

REVIEW OF ELECTRICITY (CONSUMER SAFETY) ACT 2004 ISSUES PAPER

IN THE MATTER between Alberto Mendoza and Susan Mendoza, Applicants, and NPR Limited Partnership, Respondent;

Disability Act 2006 A guide for disability service providers

first choice home insurance application first choice home

Asbestos licensing and notification guide for applicants

2010THE LEGISLATIVE ASSEMBLY FOR THEAUSTRALIAN CAPITAL TERRITORY. WORKPLACE PRIVACY BILL 2010EXPLANATORY STATEMENT Circulated by Amanda Bresnan MLA

BYLAW NO A BYLAW OF THE CITY OF MEDICINE HAT to reduce the number of False Alarms responded to by the City s Police Service and Fire Services.

Nurses Amendment Act 2003

NSW Community Housing Asset Management Policy August 2014

Landlord signature:...

Housing Codes for North Carolina As of July 2008

GOOD MANAGEMENT PRACTICE GUIDE FOR HOUSES IN MULTIPLE OCCUPATION MAY The Regional Strategic Housing Authority for Northern Ireland

APPLICATION FOR TENANCY (to be completed by all adult Applicants and unaccompanied minors)

Private Parking Areas Act 1986

Security Alarm Monitoring Agreement

Asbestos Policy & Procedure

Property Management Proposal Information

Dispute Resolution Services

REV-1 CHG-3. C. Section 202 Direct Loan and Section 202 and 811 Capital Advance projects are "assisted" and are covered under this Chapter.

Lawlink NSW: Guide to the Workplace Video Surveillance Act

CARITAS MANAGEMENT CORPORATION CALIFORNIA ADDENDUM GENERAL

Insurances For Owner Management Companies Discussion 14/03/2013

A Guide to Aged Care and Retirement Villages in Australia FOR INVESTORS AND PROSPECTIVE OPERATORS PREPARED BY ARTHUR KOUMOUKELIS, PARTNER, GADENS

BUILDING CERTIFIERS GUIDE TO BSA INSURANCE & OWNER-BUILDER REQUIREMENTS FOR RESIDENTIAL CONSTRUCTION

Transcription:

Residential Tenancy (Smoke Alarms) Act 2012 and Residential Tenancy (Smoke Alarms) Regulations 2012 The Residential Tenancy Amendment (Smoke Alarms) Act 2012 (the Act) requires smoke alarms to be installed in residential rental properties in Tasmania from 1 May 2013. The Act is supported by the Residential Tenancy (Smoke Alarm) Regulations 2012 (the Regulations) which set out detailed requirements regarding the: Class of premises required to have smoke alarms; Type of smoke alarms required; Location of alarms in premises; and Obligations of property owners and tenants to maintain, test and clean smoke alarms. Premises required to have smoke alarms All buildings that are tenanted under a residential tenancy agreement are required to be fitted with smoke alarms from 1 May 2013. The regulations require smoke alarms to be placed in tenanted premises that are, or are part of, a building that is a Class1a, Class1b, Class 2 or Class 3 building or Class 4 premises under the Building Code of Australia. Examples of the premises contained in each class include: Houses, town houses, villa units etc. (Class1a); Small guest houses, boarding houses accommodating up to 12 persons (Class1b); Apartments and blocks of flats (Class 2); Larger boarding houses (Class 3); and Caretaker flats and residences above shops (Class 4). Type of smoke alarms required Smoke alarms must comply with Australian Standard 3786-1993 Smoke Alarms, as in force from time to time.

The regulations recognise that there may be changes to Standard 3786-1993 over time. In order to ensure that owners are not required to replace alarms every time this occurs, the regulations deem that once an alarm that complies with the Standard is installed in tenanted premises, it is taken to continue to comply with the Standard until such time as it: No longer functions; or Reaches its expiry date. When an alarm is replaced, it must meet the requirements of the Standard at the time of replacement. This provision applies to alarms installed in tenanted premises both before and after commencement of the legislation. Transitional Arrangements From 1 May 2013 until 30 April 2016, smoke alarms can be battery (by either a 9-volt removable battery or a 10-year non-removable battery) powered, or mains powered, provided it complies with AS 3786-1993. This transitional arrangement reduces the immediate cost to property owners and allows them three years to budget and arrange for mains powered or ten year non-removable battery alarms to be installed. From 1 May 2016, smoke alarms will be required to be either mains powered or 10-year non-removable battery alarms. Placement of smoke alarms in premises The regulations set out where alarms are required to be located in each class of premises, in line with the relevant provisions of the Building Code of Australia. Alarms must be installed on, or near, the ceiling in each class of building/premises as follows: Class 1a building (Houses, town houses, villa units etc.) (a) if any storey of the premises contain a bedroom (i) in every corridor, or hallway, situated in the storey, that is associated with a bedroom; and (ii) if there is no corridor, or hallway, situated in the storey, that is associated with a bedroom, between that part of the premises containing the bedroom and the remainder of the premises; and (b) in any other storey of the premises that does not contain a bedroom.

Class 1b building (Small guesthouses, boarding houses accommodating up to 12 persons) (i) in each bedroom in that storey; and (ii) in every corridor, or hallway, associated with a bedroom; and (iii) if there is no corridor, or hallway, associated with a bedroom, between that part of the premises containing the bedroom and the remainder of the premises; and (b) in any other storey of the premises that does not contain a bedroom. Class 2 building (Apartments and blocks of flats) (i) in the premises, in every corridor, or hallway, associated with a bedroom in that storey; and (ii) if there is no corridor, or hallway, associated with a bedroom in that storey, between that part of the premises containing the bedroom and the remainder of the premises; and (b) in egress paths in any other storey of the premises that does not contain a bedroom. Class 3 building (Larger boarding houses) (i) in the premises, in every corridor, or hallway, associated with a bedroom in that storey; and (ii) if there is no corridor, or hallway, associated with a bedroom in that storey, between that part of the premises containing the bedroom and the remainder of the premises; and (b) in egress paths in any other storey of the premises that does not contain a bedroom. Class 4 premises (Caretaker flats and residences above shops) (i) in the premises, in every corridor, or hallway, associated with a bedroom in that storey; and (ii) if there is no corridor, or hallway, associated with a bedroom in that storey, between that part of the premises containing the bedroom and the remainder of the premises; and (b) in egress paths in any other storey of the premises that does not contain a bedroom.

Obligations of property owners Removable battery alarms At the beginning of a tenancy, owners must ensure that: Alarms function effectively; Batteries are installed; Batteries have not reached their expiry date and will not do so within 30 days of the tenancy commencing; Alarms have not reached their expiry date; and Alarms are free from dust and debris. Mains powered smoke alarms At the beginning of a tenancy, owners must ensure that: Alarms are connected to mains power; Back-up batteries are installed; Back-up batteries have not reached their expiry date and will not do so within 30 days of the tenancy commencing; Back up batteries function effectively; Alarms are free from dust and debris; Alarms function effectively; and Alarms have not reached their expiry date. During the period of a tenancy, owners must ensure that back-up batteries for mains powered alarms are replaced if the batteries: Have not been replaced for 12 months or more; Have reached their expiry date; or No longer function effectively or at all.

10-year non-removable battery alarms At the beginning of a tenancy, owners must ensure that all alarms: Are free from dust and debris; Function effectively; and Have not reached their expiry date. During the period of a tenancy, owners must ensure that batteries for 10-year non-removable alarms are replaced if they: Have been in use for more than 10 years; Have reached their expiry date; or No longer function effectively or at all. Repair of all types of alarms Owners must ensure that smoke alarms are repaired or replaced as soon as practicable after becoming aware that the alarm has reached its expiry date or no longer functions effectively. The only exception is where the alarm fails to function effectively due to the failure of removable batteries or the mains power supply, the tenant is responsible for correcting these problems. Under the Residential Tenancy Act 1997, property owners will need to give at least 24 hours notice before entering the premises to undertake any maintenance of or repairs to smoke alarms. Maintenance, testing and cleaning requirements for tenants Removable battery alarms Tenants must ensure that batteries for removable battery alarms are replaced, if the batteries: Have not been replaced for 12 months or more since the tenancy commenced; No longer function effectively or at all; or Have reached their expiry date, more than 30 days after the tenancy commenced Mains powered smoke alarms and 10-year non-removable battery alarms Tenants are not responsible for the replacement of batteries providing back up for mains powered smoke alarms, or in 10-year non-removable battery alarms.

Maintenance and testing of smoke alarms During a tenancy, every six months tenants are required to: Test all smoke alarms installed at the premises; and Remove any dust and debris from the smoke alarms. Failure or malfunction of a smoke alarm Where a smoke alarms fails or malfunctions, for reasons other than the failure of removable batteries or the mains power supply, a tenant must notify the owner as soon as practicable after becoming aware of the failure or malfunction. Miscellaneous Provisions The Act makes it an offence to remove, or interfere with the operation of, a smoke alarm in a tenanted property, except where alarms are removed for the purposes of repair or replacement. The Act also imposes penalties for failure to comply with these provisions. Where it is not practicable to install a smoke alarm on or near the ceiling, the regulations permit a smoke alarm to be installed in a place where it will, if activated, alert people in the property to the presence of smoke. The Act clarifies that where a rental property is subject to the control of a body corporate under the Strata Titles Act 1998, an owner is not required to obtain permission from the body corporate in order to install a smoke alarm in accordance with the Act. The Act also authorises the Residential Tenancy Commissioner to make an order requiring a party to a residential tenancy agreement to comply with a provision of the Act. Please Note The information in this document is correct as at 5 April 2013. The information provided here is general in nature and does not constitute legal advice. No responsibility is accepted for any errors or omissions it may contain. For precision, reference should be made to the Residential Tenancy Amendment (Smoke Alarms) Act 2012 and the Residential Tenancy (Smoke Alarm) Regulations 2012