Power over Ethernet Devices



Similar documents
Power Over Ethernet (PoE) Operation for the Series 2600-PWR Switches

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Power over Ethernet (PoE) Power Requirements FAQ

Models HP NJ2000G IntelliJack

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

DES-1005P 5-Port 10/100Mbps with 1-Port PoE Unmanaged Switch

EAGLE Power over Ethernet Products for IP Powering Applications. Flexibility, Simplicity and Value LAN POWER SYSTEMS. Trend Datacom USA, Inc.

PoE+ Extender Switch User's Manual. Rev W

3Com WHITE PAPER. Power over Ethernet Overview

COBRA Power over Ethernet Products for IP Surveillance Applications LAN POWER SYSTEMS. Trend Datacom USA, Inc.

HP ProCurve High-Speed Transceivers Installation Guide

Power over Ethernet (PoE)

ProCurve Switch 5400 and 3500 Power Over Ethernet

8-Port 10/100Mbps 802.3at PoE + 1-Port 10/100/1000Mbps Desktop Switch

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

ProCurve Networking. Troubleshooting WLAN Connectivity. Technical White paper

The ABCs of Power Over Ethernet

ALL8808POE. 8 Port Gigabit PoE+ Switch. Manual

Interface Adapters PS/2 Interface Adapter 1 pack B21 PS/2 Interface Adapter 8 pack B21 USB Interface Adapter 1 pack B21

HP ProCurve Switch 1400 Series

HP ProCurve Wireless Access Point 10ag Overview

8-Port PoE Network Switch

HP ProCurve Switch 1800 Series Overview. HP ProCurve Switch G. HP ProCurve Switch G. HP ProCurve Switch G

Power over Ethernet (PoE) Explained

Impact of Power-over-Ethernet (PoE) on Industrial-based Networking

How To Make Power Over Ethernet A Viable Alternative To A Network Cable (Networking)

Power over Ethernet technology for industrial Ethernet networks

4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Ethernet Switch Wide Temperature

Sharing Pictures, Music, and Videos on Windows Media Center Extender

How To Power A Power Supply Shelf With A Power Unit (Hp 2920)

IEEE 802.3af 4-Port Power over Ethernet Injector Hub POE-400. User s Manual

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

HP 1405 Small Office Switch Series

User Guide TL-SG1016/ TL-SG /24-port Gigabit Ethernet Switch

IP videoconferencing solution with ProCurve switches and Tandberg terminals

GEU Port Gigabit Switch

MICROSENS. Installation Switch with PoE (5x10/100Base-TX) and fiber uplink (1x100Base-FX) General. Features

HP V1410 Switch Series. Product overview. Key features. Data sheet

The Ins and Outs of PoE

8-Port 10/100Mbps 802.3af / 802.3at PoE + 1-Port 10/100/1000Mbps Desktop Switch. FGSD-910P / FGSD-910HP User s Manual

Megapixall Security Tools & Accessories

User's Manual. 8-Port 10/100Mbps with 4-Port PoE Fast Ethernet Switch FSD-804P - 1 -

HP Roar Plus Speaker. Other Features

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Cisco 110 Series Unmanaged Switches

D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch. Manual

Interoperability between Cisco Unified IP 7900 Series phones and ProCurve switches

HP UPS R1500 Generation 3

installation and getting started guide hp procurve switch

AXIS T81B22 DC 30W Midspan

HP ProCurve Switch 1800 Series

White Paper. Power over Ethernet Plus Update and Cabling Considerations

Design Guidelines for PoE Based Security Systems. Carlos Carle, P.E. SignaMax Systems, Inc.

Product Specifications

QuickSpecs. HP IP Console Switch with Virtual Media Overview

ProCurve Switch 1400 Series

Installation Guide for. 10/100 to Triple-speed Port Aggregator. Model TPA-CU Doc. PUBTPACUU Rev. 1, 12/08. In-Line

QuickSpecs. Models HP Server Console Switches

Engineering Advisory Power Consumption and Management on Polycom Phones

HP ProCurve Networking. Networking solutions for small and growing businesses

HP ProCurve Identity Driven Manager 3.0

HP V1405 Switch Series. Product overview. Key features. Data sheet

Power efficiency and power management in HP ProLiant servers

VAC 50/60Hz Power Adapter

Quick Installation Guide. EtherFast 10/100M Switch. Model No.: SP624R.

2-Port Gigabit Ethernet Switch Operations Guide

HP ProCurve 1410 Switch Series Overview. Models HP ProCurve G Switch

TP-LINK TECHNOLOGIES CO.,LTD. Website ADD FI.3,Bldg.R1-B.High-Tech Industrial Park,Shenzhen

QuickSpecs. HP 480/277 Volt Solutions. Overview

Power over Ethernet - Wikipedia, the free encyclopedia

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

QuickSpecs. HP M n Access Point Series. Models HP M n WW Access Point. Key features

Installation Guide for Gig Zero Delay Tap and 10/100/1000BaseT Tap

Power over Ethernet for VoIP Applications. White Paper

HP ProLiant power supply technology

Interoperability between Mitel IP Phones and ProCurve Switches

StorTrends 3400 Hardware Guide for Onsite Support

Internet Telephony PBX system IPX-1980

HP Server Console Switch with Virtual Media Overview

Long Reach PoE over Coaxial Extender Kit

Gigabit Switching Ethernet Media Converters - Product User Guide

8-Port 10/100/1000Mbps 802.3at PoE Desktop Switch

Release Notes: Version P.1.8 Software. Related Publications. for HP ProCurve 1810G Switches

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

MDI/MDIX) FEP-32008T-3

HP 1405 Small Office Switch Series

HP Networking and Aastra

FSW-0505TX/0805TX 5/8 Port SOHO 10/100Mbps NWay Switch FSW-0505TX FSW-0805TX. 5/8 Port SOHO 10/100Mbps NWay Switch. User s Manual. (Revision 1.

Moxa EtherDevice Switch

QuickSpecs. Models HP Server Console G2 Switch. HP Server Console Switch G2 with Virtual Media & CAC. Overview

MICROSENS Media Converter 10/100/1000T to Gigabit Fiber

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

Quick Start Guide. Cisco Small Business. 200E Series Advanced Smart Switches

Models HP 1405C-5 Switch* IEEE 802.1p prioritization: delivers data to devices based on the priority and type of traffic

ProCurve Switch 1700 Series

HP Advanced Wireless Docking Station. User Guide

palm Switch Port 10/100 Base-TX Switch with Auto MDI/MDI-X User Guide

Cisco WAP4410N Wireless-N Access Point: PoE/Advanced Security Cisco Small Business Access Points

Transcription:

Planning and Implementation Guide over Ethernet Devices over Ethernet www.procurve.com

ProCurve over Ethernet () Planning and Implementation Guide

Copyright 2003, 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translation into another language without the prior written consent of Hewlett-Packard. Publication Number 5991-2167 September 2005 Applicable Products ProCurve Switch 2626-PWR (J8164A) ProCurve Switch 2650-PWR (J8165A) ProCurve Switch 2600-8-PWR with Gigabit Uplink (J8762A) ProCurve Switch xl Module (J8161A) ProCurve 600 Redundant and External Supply (J8168A) ProCurve 610 External Supply (J8169A) Trademark Credits Windows NT, Windows, and MS Windows are US registered trademarks of Microsoft Corporation. Disclaimer HEWLETT-PACKARD COMPANY MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Hewlett-Packard assumes no responsibility for the use or reliability of its software on equipment that is not furnished by Hewlett-Packard. Warranty See the Customer Support/Warranty booklet included with the product. A copy of the specific warranty terms applicable to your Hewlett- Packard products and replacement parts can be obtained from your HP Sales and Service Office or authorized dealer.

Contents 1 Introduction Overview...................................................... 1-1 Through the Cable.................................... 1-3 Capabilities of the Products.............................. 1-4 Redundancy.......................................... 1-5 2 Using External Supplies 600 RPS/EPS and 610 EPS Operation.............................. 2-1 Redundant Switch........................................ 2-2 Operating Characteristics.................................... 2-2 External Switch.......................................... 2-3 EPS Allocation........................................ 2-3 Maximum........................................ 2-4 With and Without EPS............................. 2-5 Switch Port Priority......................................... 2-6 Switch Priority Class......................................... 2-6 Line Loss................................................... 2-7 PD Classification...................................... 2-7 3 Planning and Implementation Supported Products............................................. 3-1 PD Requirements......................................... 3-2 Number of PDs per Switch.................................... 3-2 Planning Your Configuration................................. 3-2 ProCurve 2600-8-PWR Configurations.......................... 3-4 ProCurve 2626-PWR Configurations............................ 3-5 ProCurve 2650-PWR Configurations............................ 3-7 ProCurve Switch xl Module Configurations................ 3-11 Infrastructure Requirements..................................... 3-16 iii

Glossary Index iv

1 Introduction This chapter provides an overview of over Ethernet () and a list of reasons why you might want to implement in your environment. It discusses how transmits power over twisted pair cable and the capabilities of the devices used to provide. Introduction Overview over Ethernet technology allows IP telephones, wireless LAN Access Points and other appliances to receive power as well as data over existing LAN cabling, without needing to modify the existing Ethernet infrastructure. over Ethernet is likely to become a standard feature of ethernet switches in a few years, as the cost of adding power supplies to the Ethernet switches is going to be small. IEEE 802.3af is an extension to the existing Ethernet standards. It offers the first truly international standard for power distribution (consider how many different AC power plugs exist worldwide). Almost all appliances require both data connectivity and a power supply. Just as telephones are powered from the telephone exchange through the same twisted pair that carries the voice, we can now do the same thing with Ethernet devices. The technology is bound to make a big impact in the world of embedded computing. In the realm of embedded computers, where the systems are increasingly connected to LANs and the internet, the advantages of providing power and data through a single cable should be obvious. Consider a typical application: a system for a car park that includes security cameras, information signs, call-for-help telephones and vehicle sensors. Such a system is distributed over a significant area, where main power is not easily available. A single link to a Ethernet Switch makes implementing this system less expensive and faster than using a non- switch. 1-1

Fault ProCurve Switc h 2600-PWR J8762A Status RPS LED Mode EPS Fan Test Act FDx Spd * Reset Clear Console * Spd mode: of f = 10 Mbps, flash = 100 Mbps, on = 1000 Mbps Link Dual-Personality P ort: -Integrated 10/1 00-TX P orts (1-8) (Ports are HP A uto-mdix) 10/1 00/1 000-T (T) o r Mini-GBIC (M) (Port 9T is IEEE A uto MDI/MDIX) 1 Mode 2 3 4 Link 5 Mode 6 7 8 Link 9T Mode 9M Link Mode! Use only one (T or M) for Port 9 Introduction Overview Introduction over Ethernet connections to embedded computers will allow much cheaper installation (no AC cabling, lower labor costs), facilitate updating the installation and repositioning of sensors without electricians, while maintaining full control over every node through the internet, with VoIP and webcam telephony. Functionality can be changed by downloading new software through the network. Figure 1-1 shows a typical system implemented to power telephones and wireless access points. The Ethernet switches are installed to supply power over the twisted pair LAN cables to run phones or other appliances as required. 610 EPS Mitel 3300 IP PBX 5300xl Switch Switch Switch 600 RPS/EPS Wireless Access Points Figure 1-1. Example of a Typical Implementation 1-2

Introduction Overview Here are some reasons why you might want to do this: Simplifies installation and saves space - only one set of wires to bring to your appliance. Saves time and money - there is no need to pay for additional electrical power runs or to delay your installation schedule to make them. Minimal disruption to the workplace - the appliance can be easily moved, to wherever you can lay a LAN cable. Safer - no AC voltages need to be added for additional network devices. As well as the data transfer to and from the appliance, you can use SNMP network management infrastructure to monitor and control the appliances. Appliances can be shut down or reset remotely - no need for a reset button or power switch. When implementing wireless LAN systems it simplifies the radio frequency (RF) survey task, as the access point can easily be moved and wired in. Introduction Through the Cable A standard CAT5 Ethernet cable has four twisted pairs, but only two of these pairs are used for 10Base-T and 100Base-TX data. The specification allows two options for using these cables for power: The spare pairs are used. The pair on pins 4 and 5 are connected together and form the positive supply, and the pair on pins 7 and 8 are connected and form the negative supply. The data pairs are used. Since Ethernet pairs are transformer coupled at each end, it is possible to apply DC power to the center tap of the isolation transformer without upsetting the data transfer. In this mode of operation the pair on pins 3 and 6 and the pair on pins 1 and 2 can be of either polarity. The standard does not allow both pairs (spare and data) to be used - a choice must be made. The Sourcing Equipment (PSE) applies power to either set of wires. ProCurve Networking supplies power over the data pair. The ed Device (PD) must be able to accept power from both options. 1-3

J8762A Status Link Mode Link (Port 9T is IEEE Auto MDI/MDIX) Mode Link Mode! Use only one (T or M) for Port 9 Introduction Overview Introduction An obvious requirement of the specification is to prevent damage to existing Ethernet equipment. A discovery process, run from the PSE, examines the Ethernet cables, looking for devices that comply with the specification. It does this by applying a small current-limited voltage to the cable and checks for the presence of a 25k ohm resistor in the remote device. Only if the resistor is present, will the full wattage be applied, but this is still current-limited to prevent damage to cables and equipment in fault conditions. The PD must continue to draw a minimum current. If it does not (for example, when the device is unplugged) then the PSE removes the power and the discovery process begins again. Capabilities of the Products The ProCurve switch devices are multiport switches that can be used to build high-performance switched workgroup networks with. These switches are store-and-forward devices that offer low latency for high-speed networking. The ProCurve switch devices are designed to support Redundant Supply and over Ethernet () technologies. The 2650-PWR (J8165A), has 48 Integrated auto-sensing 10/100Base- TX RJ-45 ports with two dual-personality Gigabit Uplink ports. 2626-PWR (J8164A), has 24 Integrated auto-sensing 10/100Base-TX RJ-45 ports with two dual-personality Gigabit Uplink ports. 2600-8-PWR with Gigabit Uplink (J8762A), has 8 Integrated autosensing 10/100Base-TX RJ-45 ports with one dual-personality Gigabit Uplink port. The 2600-8-PWR also supports some pre-standard devices. For a list of these devices, see the FAQs for your switch model. This feature must be enabled, it is not a default feature. Fault ProCurve Switch 2600-PWR RPS EPS Fan Test LED Mode Act FDx Spd * Reset Clear Console * Spd mode: off = 10 Mbps, flash = 100 Mbps, on = 1000 Mbps -Integrated 10/100-TX Ports (1-8) (Ports are HP Auto-MDIX) 1 2 3 4 Link 5 Mode 6 7 8 9T Dual-Personality Port: 10/100/1000-T (T) or Mini-GBIC (M) 9M The dual-personality ports have either auto-sensing 10/100/1000Base-T RJ-45, or mini-gbic connectivity. The dual-personality ports do not support. 1-4

Introduction Overview The ProCurve Switch xl Module (J8161A) is a module for the ProCurve 5300xl Switch and has 24 -Ready auto-sensing 10/100-TX RJ-45 ports. hp procurve xl module J8161A Status EPS LED Mode Std Link 1 Mode 2 3 4 5 6 13 14 15 16 17 Link 18 Mode 7 8 9 10 11 12 19 -Ready 10/100-TX Ports (1-24) all ports are HP Auto-MDIX 20 21 22 23 24 xl module Introduction All 24 ports are capable of supplying power. However, for the module ports to be able to supply power it first must be connected to an EPS port on a ProCurve 600 Redundant and External Supply (J8168A), or the ProCurve 610 External Supply (J8169A), hereafter referred to as the 600 RPS/EPS or the 610 EPS, respectively. These switch devices are designed to be used primarily in wiring closets directly connected to computers, printers, and servers to provide dedicated bandwidth to those devices. In addition, they support the standard, IEEE 802.3af, and can supply power over a twisted-pair cable to power devices such as telephones and wireless access points. Redundancy The internal power supply in these switches provides both the 12V (RPS) and 50V (EPS) circuits. If either the 12V or 50V fails, the power supply shuts down which will bring down all switch and connections. Therefore it is important to provide a redundant power supply for both the 12V and 50V circuits. Thus when you connect EPS from a 600 RPS/EPS device to one of the Series 2600-PWR Switches, you should also connect the RPS as well to provide full redundant power. The Series 2600-PWR Switches can be connected to a 600 RPS/EPS and receive full redundant power from the RPS part of the unit for switch operation, if the internal power supply in the switch fails. If multiple switches are connected to the RPS ports and several switches lose power at the same time, the switch attached to the lowest RPS port number receives power. The 600 RPS/EPS unit can provide all the power necessary to keep one switch running. EPS power from the 600 RPS/EPS is the capability of the device. It supplies backup and additional power for the ports of the 2600-PWR Switches. It also provides power to the ProCurve Switch xl Module. The 610 EPS can also be used for this purpose, to supply power only. The 610 EPS cannot supply RPS power, it can only supply power. 1-5

This page is intentionally unused.

2 Using External Supplies This chapter discusses the operating rules and characteristics of the ProCurve External Supplies and describes the capabilities of two devices: The ProCurve 600 Redundant and External Supply (J8168A), hereafter referred to as the 600 RPS/EPS, is used to provide redundant and external power. The ProCurve 610 External Supply (8169A), hereafter referred to as the 610 EPS, is used to provide external power only. The 600 RPS/EPS and the 610 EPS are accessory products for the Series 2600- PWR Switches, the ProCurve Switch xl Module, and specific other ProCurve switches. The redundant power supply (RPS) and external power supply (EPS) features are explained below. Using External Supplies 600 RPS/EPS and 610 EPS Operation The 600 RPS/EPS monitors the power signal from a switch by detecting that it is connected to the switch with an RPS or EPS cable. When the power from the switch is no longer detected, the 600 RPS/EPS provides power to the switch within 1 millisecond. The 600 RPS/EPS supports hot plugging of an RPS or EPS cable. For more information refer to the documentation that came with the 600 RPS/EPS. For connectivity refer to the ProCurve Series 2600 Switches Installation and Getting Started Guide that came with your switch. The 610 EPS operates in much the same way except it does not supply redundant, RPS power. It only has the capability to supply external power. Therefore, there are no RPS cables or ports on a 610 EPS. 2-1

Using External Supplies Redundant Switch Redundant Switch The 600 RPS/EPS provides redundant power to any one of up to six switch products, to back up the power supply in a switch in case of loss of AC power, or a fault condition. The 600 RPS/EPS is an unmanaged power supply that only provides information by way of LEDs or through the port interfaces to attached devices. Operating Characteristics Using External Supplies The 600 RPS/EPS has six RPS ports, each of which can provide redundant +12V power to a connected switch, but only one port can provide this power at a given time. If a switch with no AC power is connected to an operating 600 RPS/EPS, it will receive power if power is available (no higher priority port is already using the RPS power). Figure 2-1. Example RPS Connections on the 600 RPS/EPS 2-2

Using External Supplies External Switch If the power to a switch fails, power is provided from the 600 RPS/EPS, if it is available, that is, if the 600 RPS/EPS is not already providing power to a higher priority switch. If two or more devices fail, priority goes to the device plugged into the lower numbered port on the 600 RPS/EPS unit. Consequently the most important switch should be plugged into port one on the 600 RPS/EPS. In this state, the Connected LED should be ON, and the Status LED should be BLINKING on the lower priority RPS port not supplying power. (For further information refer to the Installation and Getting Started Guide that came with your 600 RPS/EPS unit.) External Switch The 600 RPS/EPS provides external power to up to two switch devices through two EPS ports, and the 610 EPS provides external power to up to four switch devices through four EPS ports. The amount of power provided depends on how many switches (one to four) are connected. For example, using a 600 RPS/EPS you can connect one EPS port to a Switch 2650- PWR and connect the other EPS port to a ProCurve Switch xl Module. Or, using a 610 EPS device you could connect up to four ProCurve Switch xl Modules, or any number of other variations. Using External Supplies EPS Allocation The 600 RPS/EPS has one power supply of 408 watts and the 610 EPS has two power supplies of 408 watts each that can supply power to connected switch devices either as the primary source of power, such as with the Switch xl Module, or as a level of additional power for devices that have internal power supplies. For the Switch 2600-8-PWR and the 2626- PWR the external power is redundant power, used if the internal power supply fails. However, when both ports of pair A or pair B of the 610 EPS, or the two ports of the 600 RPS/EPS are connected to two switches, the supplied power to each switch is cut in half. In other words, each switch only receives 204 watts of power. The same holds true, for example, if you have connected one EPS port to a Switch 2626-PWR and the other EPS port to a ProCurve Switch xl Module. The 408 watts from the 600 RPS/EPS will be split between the two switch devices. However, if you are using a 610 EPS and you connect one port of pair A to a Switch 2626-PWR and one port of pair B to a ProCurve Switch xl Module, they each will receive 408 watts. 2-3

Using External Supplies External Switch Maximum The Switch 2626-PWR provisions (allocates power to) ports 1-24 with 406 watts of power for applications compatible with the IEEE 802.3af standard. The Switch 2650-PWR provisions ports 1-48 with 406 watts. This reduces the per port wattage by half as compared to the Switch 2626-PWR. However, by connecting a 600 RPS/EPS or a 610 EPS, you can optionally provision ports 25-48 with 408 watts of external power, thereby bringing the per port wattage up to 15.4 watts per port, unless you have the other EPS port of the 600 RPS/EPS or the other port of a pair on the 610 EPS connected to a ProCurve device. In this case you cannot provision the full 408 watts to the Switch 2650-PWR, only half, or 204 watts. Using External Supplies Table 2-1. Maximum Allocations Devices Internal Only Internal and EPS EPS Only for Switch 2600-8-PWR 126 watts available to ports 1-8. 126 watts available to ports 1-8 (provided by the internal source). 408/204* watts available, provided by the EPS source. The internal power supply has failed, and the EPS provides 408/204* watts to ports 1-8. for Switch 2626-PWR 406 watts available to ports 1-24. Redundant 408/204* watts available to ports 1-24. Only if the internal power supply fails. 408/204* watts available to ports 1-24. (The EPS provides power to ports 1-24 only if the internal power supply fails.) for Switch 2650-PWR 406 watts available to ports 1-48. 406 watts available to ports 1-24 (provided by the internal source). 408/ 204* watts available to ports 25-48 (provided by the EPS source). The internal power supply has failed, and the EPS provides 408/204* watts to ports 1-48. Note that 38 watts of this power are always allocated exclusively to ports 1-24 or 25-48.) See page 3-7. ProCurve Switch xl Module No internal power. 408/204* watts available to ports 1-24 from the EPS only. 408/204* watts available to ports 1-24. * If both EPS ports on the 600 RPS/EPS or both ports of a pair on the 610 EPS are connected to switches, each switch can receive 204 watts of power. If a single switch is connected to the EPS ports, that switch can receive 408 watts. 2-4

Using External Supplies External Switch With and Without EPS It is important to understand the power requirements of these switch devices because if the power is not planned and implemented correctly, end devices connected to the switch ports may not receive power if an internal switch power source failure occurs. The Switch 2600-8-PWR has 8 ports and its internal power supply provides 126 watts across all 8 ports. If a 600 RPS/EPS or a 610 EPS device is connected to the Switch 2600-8-PWR for the purpose of supplying external power to the portion of the switch, there will be either 408 watts or 204 watts of power available should the switch s internal power supply fail. If a single switch is connected to the EPS ports on the 600 RPS/EPS or a single port of a pair on the 610 EPS, 408 watts are available, providing fully redundant power to the switch. If two switch devices are connected to the EPS ports on the 600 RPS/EPS or to both ports of a pair on the 610 EPS, only 204 watts are provided to the switch if the internal power supply fails. This will still provide enough wattage to be a full backup for the Switch 2600-8-PWR because it only needs 126 watts. The Switch 2626-PWR has 24 ports and its internal power supply provides 406 watts across all 24 ports. If a 600 RPS/EPS or a 610 EPS device is connected to the Switch 2626-PWR for the purpose of supplying external power to the portion of the switch, there will be either 408 watts or 204 watts of power available should the switch s internal power supply fail. If a single switch is connected to the EPS ports on the 600 RPS/EPS or a single port of a pair on the 610 EPS, 408 watts are available, providing fully redundant power to the switch. If two switch devices are connected to the EPS ports on the 600 RPS/EPS or to both ports of a pair on the 610 EPS, only 204 watts are provided to the switch if the internal power supply fails. Using External Supplies The Switch 2650-PWR power requirements are different. This switch has 48 ports and the internal power supply supplies 406 watts across all 48 ports. The switch reserves 38 watts for either ports 1-24 or 25-48, so that neither set of ports receives the entire 406 watts. By connecting a 600 RPS/EPS or a 610 EPS to the Switch 2650-PWR, more power is provided to the switch. With the 600 RPS/EPS or the 610 EPS connected to the Switch 2650-PWR, the internal power supply provides the first 24 ports (1-24) with 406 watts and the 600 RPS/EPS or the 610 EPS supplies the second 24 ports (25-48) with 408 or 204 watts (408 watts if only one switch is connected to the EPS ports; 204 watts if two switches are connected to the EPS ports). If the internal power supply in the 2650- PWR switch fails, 408 watts or 204 watts are provided to ports 1-48. 38 watts of power are always allocated to ports 1-25 or 25-48. See page 3-7. 2-5

Using External Supplies External Switch Switch Port Priority The lower the port number the higher the priority given. For example, port number one has a higher priority than port number two. Therefore when both ports need power, port number one is given power priority over port number two and so on throughout the rest of the ports. A port can be assigned a power priority that alters the assignment of power to it by the switch. See the software manual that came with your switch for details. Switch Priority Class Using External Supplies Port priority classification can be used by the switch to allocate power to ports. It is a prioritization scheme by which the user can assign a low (default), high, or critical priority to any given port. This assignment is done through the command line interface (see the software manual that came with your switch) of the switch and alters the hardware port-number priority for power allocation. Low (default) - This priority class receives power only if all other priority classes are receiving power. If there is enough power to provision PDs on only some of the ports with a low priority, then power is allocated to the ports in ascending order, beginning with the lowest-numbered port in the class until all available power is in use. High - This priority class receives power only if all PDs on ports assigned with a critical priority are receiving full power. If there is not enough power to provision PDs on ports assigned with a High priority, then no power goes to the low priority ports. If there is enough power to provision PDs on only some of the High priority ports, then power is allocated to the High priority ports in ascending order, beginning with lowestnumbered high priority port, until all available power is in use. Critical - This priority class always receives power. If there is not enough power to provision PDs on all of the ports configured for this class, then no power goes to High or Low priority ports. If there is enough power to provision PDs on only some of the Critical ports, then power is allocated to the Critical ports in ascending order, beginning with the lowest-numbered port in the class. 2-6

Using External Supplies External Switch Line Loss A certain amount of power is consumed from the switch to the powered device (typically less than 16% loss), which can be influenced by cable length, quality, and other factors. The IEEE 802.3af specification has addressed loss of power by providing more power than a powered device requires. As well, depending upon the classification (Class 0-3) of the device, the switch will provide more or less power to address the specific power needs of that end device. PD Classification A PD is classified based on the maximum power it draws across all input voltages and operational modes. The most common class is 0, in which the switch will allow a maximum draw of 15.4 watts per port. As an example, 15.4 watts - Loss (16%) = 12.95 watts. See table 2-2. Table 2-2. Usage Class Usage Minimum Levels at Output of PSE Range of Maximum required by the PD Using External Supplies 0 Default 15.4 Watts 0.44 to 12.95 Watts 1 Optional 4.0 Watts 0.44 to 3.84 Watts 2 Optional 7.0 Watts 3.84 to 6.49 Watts 3 Optional 15.4 Watts 6.49 to 12.95 Watts As you can see in the table, any 802.3af compliant PD will never require more than 12.95 watts. The switch provides a minimum of 15.4 watts at the port in order to guarantee enough power to run a device, after accounting for line loss. 2-7

This page is intentionally unused.

3 Planning and Implementation This chapter discusses the planning process a user should follow to successfully implement a switch. After understanding what is and its operating rules, the next step to implementation is planning. The following is an example list of considerations during the planning phase: What devices will need power? How much power will each device require? What if power is lost to the switch? for the switch to operate (AC power) for devices Which devices to plug into which ports and with what priorities? Are the appliances to be powered by power supported? Supported Products The ProCurve Series 2600-PWR Switches and the ProCurve Switch xl Module support any products that meet the IEEE 802.3af standard. The 2600-8-PWR also supports some pre-standard devices. For a current list see the FAQ page for the 2600-8-PWR Switch, which can be found on the ProCurve Web site, http://www.procurve.com, Technical Support, FAQs (all). Planning and Implementation 3-1

Planning and Implementation PD Requirements PD Requirements When a PD is initially connected to a port, a minimum of 15.4 watts of available power is required to begin the power-up sequence. This 15.4 watts is needed to determine the type of PD requesting power (see PD Classification on page 2-7). Once the power classification is determined and power is supplied, any power beyond the maximum power requirements for that class of PD is available for use. In the default switch configuration all ports have a Low priority. If the switch has less than 15.4 W of power available, the switch transfers power from lower-priority ports to higher-priority ports. See Switch Priority Class on page 2-6 for information on the use port priority classifications. Within each priority class, a lower numbered port is supplied power before a higher numbered port. Disconnecting a PD from a port causes the switch to stop providing power to that port and makes that power available to other ports configured for operation. Number of PDs per Switch Planning and Implementation The number of PDs supported per switch depends on the power allocation and how much power each PD uses and how much power is left. The following examples show the power consumption in some typical configurations. Planning Your Configuration This section assists you in building a reliable and, if required, redundant configuration. Using the following examples you can plan, build, and connect your devices quickly and easily. There are four configurations: ProCurve Switch 2600-8-PWR with Gigabit Uplink ProCurve Switch 2626-PWR ProCurve Switch 2650-PWR ProCurve Switch xl Module 3-2

Planning and Implementation Planning Your Configuration Each example shows a complete configuration including an optional 600 RPS/ EPS or 610 EPS unit. A table shows the power available to connected devices when using just the switch or when using the switch and either the 600 RPS/EPS or 610 EPS unit. The tables show the available power when the 600 RPS/EPS or 610 EPS unit is providing power to connected switch devices. Once you have selected your specific configuration and the power provided, you then add up the maximum amount of power each of your IEEE 802.3af-compliant devices require (use maximum power in watts, usually found on a product s data sheet). Adjust this total maximum power figure by adding 15% to account for possible line loss. This value must be less than the maximum power available shown in the table for your configuration. If you are planning to include redundant power in your configuration you need to determine which devices must receive redundant power, then total their power requirements as explained in the paragraph above. The maximum power figure must be less than the maximum power available when the switch is powered by the 600 RPS/EPS or the 610 EPS unit, taking into consideration the number of switches the 600 RPS/EPS or 610 EPS unit is powering. Note Full redundancy is achieved by connecting both the RPS and EPS ports of the 2600-PWR Switches to the corresponding ports of a 600 RPS/EPS. The following examples only show the EPS connections, however, remember these switches use a single internal power supply which provides two isolated output voltages for switch and functionality. One supply voltage provides power for the switch functionality while the isolated voltage provides power for the functionality. If either voltage fails, the entire power supply shuts down disconnecting all switch and connections. Therefore it is important to provide redundancy for each isolated voltage. Planning and Implementation 3-3

Multiple power sources. Disconnect both the AC power cord and the RPS cable to completely remove power from the unit. Planning and Implementation Planning Your Configuration ProCurve 2600-8-PWR Configurations The tables in the example configurations contain entries that show the power available when the 2600-8-PWR is used alone. When used with the 600 RPS/EPS or 610 EPS unit, power is available to the ports should the internal power supply fail. Table entries show the power available when the 600 RPS/EPS or 610 EPS alone provides power. ProCurve Switch 2600-8-PWR EPS R edundant Input ProCurve RPS Input! Line: 50/60 Hz 100 240 V~ 3.3 A (3,3 A) 600 RPS/EPS Figure 3-1. Example of a 600 RPS/EPS ing One 2600-8-PWR Switch Planning and Implementation Source of Internal Supply External Supply (Failed Internal Supply) Watts Available # of Ports ed and Average Watts/Port 126 8 @ average 15.4 W each Redundant # of Ports ed and Average Watts/ Port 408 8 @ average 15.4 W each A single 2600-8-PWR switch with a dedicated 600 RPS/EPS unit has fully redundant power for all 8 ports at 15.4 W per port. Also (not shown), two 2600-8-PWR switches with a dedicated 600 RPS/ EPS unit has full redundant power for both switches. The 600 RPS/ EPS supplies 408 watts to one switch and 204 watts to each switch when two switches are connected to the 600 RPS/EPS. 3-4

ProCurve 2626-PWR Configurations Planning and Implementation Planning Your Configuration The tables in the example configurations contain entries that show the power available when the 2626-PWR is used alone. When used with the 600 RPS/EPS or 610 EPS unit, power is available to the ports should the internal power supply fail. Table entries show the power available when the 600 RPS/EPS or 610 EPS alone provides power. 600 RPS/EPS ProCurve Switch 2626-PWR Figure 3-2. Example of an 600 RPS/EPS ing One 2626-PWR Switch Source of Internal Supply External Supply (Failed Internal Supply) Watts Available # of Ports ed and Average Watts/Port 406 24 @ average 15.4 W each Redundant # of Ports ed and Average Watts/ Port 408 24 @ average 15.4 W each Planning and Implementation A single 2626-PWR switch with a dedicated 600 RPS/EPS unit has fully redundant power for all 24 ports at 15.4 W per port. 3-5

Planning and Implementation Planning Your Configuration 600 RPS/EPS ProCurve Switch 2626-PWR Figure 3-3. Example of an 600 RPS/EPS ing Two 2626-PWR Switches Source of Watts Available # of Ports ed and Average Watts/Port Redundant # of Ports ed and Average Watts/ Port Planning and Implementation Internal Supply External Supply (Failed Internal Supply) 406 24 @ average 15.4 W each 204 24 @ 7.6 W each 12 @ 15.4 W each When two switches are connected to the 600 RPS/EPS ports, the power available to each switch is a maximum of 204 W. If all of your PDs consume on average less than 7.6 W each (allowing for any line loss) then all 24 ports will receive redundant power should a switch s internal power supply fail. Redundant power is available as long as the total power required remains below 204 W. 3-6

ProCurve 2650-PWR Configurations Planning and Implementation Planning Your Configuration The tables in the example configurations contain entries that show the power available when the 2650-PWR is used alone. When used with the 600 RPS/EPS or 610 EPS unit, additional power is available to the ports and power is available should the switch s internal power supply fail. Table entries show the power available when the 600 RPS/EPS or the 610 EPS alone provides power. In the following examples using the ProCurve 2650-PWR switch, reference is made to two blocks of ports: ports 1-24 and ports 25-48. This applies when external power is available from an 600 RPS/EPS or 610 EPS unit. In that case, the internal switch power supply provides 406 watts of power to ports 1-24 and the 600 RPS/EPS or 610 EPS provides 408 watts of power to ports 25-48. If you are using the ProCurve Switch 2650-PWR with external power, the number of ports with available power when the switch is powered by just the 600 RPS/EPS or 610 EPS unit may be less than the number of ports powered when both the switch and the 600 RPS/EPS or 610 EPS unit are supplying power. In the default configuration the number and location of ports with redundant power is determined by three factors: The number of switches drawing external power from the 600 RPS/ EPS or 610 EPS unit. If only a single switch is using external power the 600 RPS/EPS or 610 EPS provides 408 watts of power. If two switches are using external power from the 600 RPS/EPS or two switches are connected to the same pair on the 610 EPS, a switch receives 204 watts of power. Should the switch s internal power supply fail, the 600 RPS/EPS or 610 EPS provides power up to the wattage stated above. When the internal power supply fails, the 600 RPS/EPS reserves a minimum of 38 watts for the less-loaded bank of ports. In the default configuration, at a minimum, the first two ports in the bank (1 and 2 or 25 and 26) will have power. Planning and Implementation Note It is the ports configured with the highest priority of either bank (1-24 or 25-48) that will receive power. For example, if the highest priority ports have been re-configured to be 23, 24 and 47, 48, then they will have power. In the default configuration power priority is determined by port number, with the lowest numbered port having the highest priority. If redundant power is required, use the example tables to determine how much power is available to which ports. 3-7

Planning and Implementation Planning Your Configuration 600 RPS/EPS ProCurve Switch 2650-PWR Figure 3-4. Example of an 600 RPS/EPS One Switch Source of Watts Available # of Ports ed and Average Watts/Port Redundant # of Ports ed and Average Watts/ Port Internal Supply 406 24 @ average 15.4 W each 48 @ average 8.5 W each Planning and Implementation Internal plus External Supply External Supply (Failed Internal Supply) 406 + 408 1-24 25-48 408 (38 W is reserved for either ports 1-24 or 25-48) 48 @ average 15.4 W each 24 @ average 15.4 W each 48 @ average 8.5 W each The lowest loaded bank of ports (1-24 or 25-48) has 38 watts reserved. That power is available for use by the two highest priority ports in the bank, (in a default configuration ports 1 and 2, or 25 and 26). 3-8

Planning and Implementation Planning Your Configuration 600 RPS/EPS ProCurve Switch 2650-PWR Figure 3-5. Example of an 600 RPS/EPS ing Two Switches Source of Internal Supply Internal plus External Supply Watts Available # of Ports ed and Average Watts/Port 406 24 @ average 15.4 W each 406 + 204 1-24 25-48 48 @ average 8.5 W each 24 @ average 15.4 W each and 24 @ 8.5 W each or Redundant # of Ports ed and Average Watts/ Port Planning and Implementation 36 @ average 15.4 W each External Supply (Failed Internal Supply) 204 (38 W is reserved for either ports 1-24 or 25-48) 10 (bank 1) and 2 (bank 2) @ average 15.4 W each 19 (bank 1) and 4 (bank 2) @ average 8.5 W each 48 @ average 4.2 W each The lowest loaded bank of ports (1-24 or 25-48) has 38 W reserved and is bank 2 in the table above. 3-9

Fan/Temp Status flash = Temperature too high Fan/Temp Status + Fault flash = Fan failure 50 V 16 A 50 V 16 A 50 V 16 A 50 V 16 A In Ready Out Ready RPS 12 V 7.5 A RPS 12 V 7.5 A RPS 12 V 7.5 A RPS 12 V 7.5 A (408 W total for applications) Device Connected Line: 50/60 Hz. 100-240 V~ 7.5 A Line: 50/60 Hz. 100-240 V~ 7.5 A Line: 50/60 Hz. 100-240 V~ 7.5 A Line: 50/60 Hz. 100-240 V~ 7.5 A Planning and Implementation Planning Your Configuration ProCurve Series 2600-PWR Switches 610 EPS hp procurve 610 eps J8169A EPS Ports EPS A1 Pair A A1 Device Connected Status EPS A2 EPS Ports Pair B (408 W total for applications) A2 B1 B2 EPS B1 EPS B2 Status Internal Status Backup Ports Status Fault Fan/Temp Status EPS Ports: 50V 8.3A max each. Figure 3-6. Example of an 610 EPS ing Four Switches Planning and Implementation Source of Internal Supply Watts Available # of Ports ed and Average Watts/Port 406 24 @ average 15.4 W each 48 @ average 8.5 W each Redundant # of Ports ed and Average Watts/ Port Internal plus External Supply 406 + 204 1-24 25-48 24 @ average 15.4 W each and 24 @ 8.5 W each or 36 @ average 15.4 W each External Supply (Failed Internal Supply) 204 (38 W is reserved for either 1-24 or 25-48) 10 (bank 1) and 2 (bank 2) @ average 15.4 W each 19 (bank 1) and 4 (bank 2) @ average 8.5 W each 48 @ average 4.2 W each With all four EPS ports in use, each switch only receives 204 watts. 3-10

hp procurve xl module J8161A Link LED Mode Std EPS Status 1 Mode 2 3 4 5 6 7 8 9 10 11 12 19 -Ready 10/100-TX Ports (1-24) all ports are HP Auto-MDIX 13 14 15 16 17 Link 18 20 21 22 23 24 Mode module Planning and Implementation Planning Your Configuration ProCurve Switch xl Module Configurations For the ProCurve Switch xl Module to function it must be installed in an ProCurve Switch 5300xl. The module will receive it s operational power from the switch and it s power from the 600 RPS/EPS or an 610 EPS. ProCurve Switch 5300xl ProCurve Switch xl module xl 600 RPS/EPS Figure 3-7. Example of an 600 RPS/EPS ing One Module Note In this example there is only one module connected to the 600 RPS/EPS, therefore it will be supplied with 408 watts of power to be distributed to all it s 24 ports at 15.4 watts per port. When planning the installation of the ProCurve Switch xl Module you must pay attention to the cabling. In a rack type installation, the 600 RPS/EPS is installed with the EPS ports in the rear, opposite this graphic. This means the EPS cable must come from the back of the 600 RPS/EPS unit and connect to the front of the module. Planning and Implementation Source of External Supply Watts Available # of Ports ed and Average Watts/Port 408 24 @ average 15.4 W each None Redundant # of Ports ed and Average Watts/ Port 3-11

hp procurve J8161A Link LED Mode Std EPS Status 1 Mode 2 3 4 5 6 7 8 9 10 11 12 19 -Ready 10/100-TX Ports (1-24) all ports are HP Auto-MDIX 13 14 15 16 17 Link 18 20 21 22 23 24 Mode module hp procurve J8161A Link LED Mode Std EPS Status 1 Mode 2 3 4 5 6 7 8 9 10 11 12 19 -Ready 10/100-TX Ports (1-24) all ports are HP Auto-MDIX 13 14 15 16 17 Link 18 20 21 22 23 24 Mode module Planning and Implementation Planning Your Configuration ProCurve Switch 5300xl ProCurve Switch xl modules xl module xl xl module xl 600 RPS/EPS Figure 3-8. Example of an 600 RPS/EPS ing Two Modules Planning and Implementation In this example there are two modules connected to the 600 RPS/EPS, therefore each module will be supplied with 204 watts of power to be distributed to each modules 24 ports at 8.5 watts per port. Source of External Supply Watts Available 204/each module # of Ports ed and Average Watts/Port 24 @ average 8.5 W each None Redundant # of Ports ed and Average Watts/ Port 3-12

hp procurve J8161A Link LED Mode Std EPS Status 1 Mode 2 3 4 5 6 7 8 9 10 11 12 19 -Ready 10/100-TX Ports (1-24) all ports are HP Auto-MDIX 13 14 15 16 17 Link 18 20 21 22 23 24 Mode module hp procurve J8161A Link LED Mode Std EPS Status 1 Mode 2 3 4 5 6 7 8 9 10 11 12 19 -Ready 10/100-TX Ports (1-24) all ports are HP Auto-MDIX 13 14 15 16 17 Link 18 20 21 22 23 24 Mode module Planning and Implementation Planning Your Configuration ProCurve Switch 5300xl ProCurve Switch xl modules xl module xl xl module xl 610 RPS/EPS Figure 3-9. Example of an 610 EPS ing Two Modules In this example there are two modules connected to the 610 EPS. Each module will be supplied with 408 watts of power to be distributed to each modules 24 ports at 15.4 watts per port, because each module is connected to a different pair. One module to one port of pair A and one module to one port of pair B. Source of External Supply Watts Available 408/each module # of Ports ed and Average Watts/Port 24 @ average 15.4 W each None Redundant # of Ports ed and Average Watts/ Port Planning and Implementation 3-13

hp procurve J8161A Link LED Mode Std EPS Status 1 Mode 2 3 4 5 6 7 8 9 10 11 12 19 -Ready 10/100-TX Ports (1-24) all ports are HP Auto-MDIX 13 14 15 16 17 Link 18 20 21 22 23 24 Mode module hp procurve J8161A Link LED Mode Std EPS Status 1 Mode 2 3 4 5 6 7 8 9 10 11 12 19 -Ready 10/100-TX Ports (1-24) all ports are HP Auto-MDIX 13 14 15 16 17 Link 18 20 21 22 23 24 Mode module Planning and Implementation Planning Your Configuration ProCurve Switch 5300xl ProCurve Switch xl modules xl module xl xl module xl 610 RPS/EPS Figure 3-10. Example of an 610 EPS ing Two Modules Planning and Implementation In this example there are two modules connected to the 610 EPS, however each module will be supplied with 204 watts of power to be distributed to each module s 24 ports at 8.5 watts per port, because both modules are connected to the same pair of ports, pair A. Source of External Supply Watts Available 204/each module # of Ports ed and Average Watts/Port 24 @ average 8.5 W each None Redundant # of Ports ed and Average Watts/ Port 3-14

hp procurve J8161A hp procurve J8161A Link Link LED Mode Std EPS Status 1 Mode 2 3 4 5 6 7 LED Mode Std EPS Status 1 Mode 2 3 4 5 6 7 8 8 9 9 10 10 11 11 12 12 19 19 -Ready 10/100-TX Ports (1-24) all ports are HP Auto-MDIX 13 14 15 16 17 Link 18 20 -Ready 10/100-TX Ports (1-24) all ports are HP Auto-MDIX 13 14 15 16 17 Link 18 20 21 21 22 23 24 22 23 24 Mode Mode module module hp procurve J8161A hp procurve J8161A Link Link LED Mode Std EPS Status 1 Mode 2 3 4 5 6 7 LED Mode Std EPS Status 1 Mode 2 3 4 5 6 7 8 8 9 9 10 10 11 11 12 12 19 19 -Ready 10/100-TX Ports (1-24) all ports are HP Auto-MDIX 13 14 15 16 17 Link 18 20 -Ready 10/100-TX Ports (1-24) all ports are HP Auto-MDIX 13 14 15 16 17 Link 18 20 21 21 22 23 24 22 23 24 Mode Mode module module Planning and Implementation Planning Your Configuration ProCurve Switch 5300xl ProCurve Switch xl modules xl module xl xl module xl xl module xl xl module xl 610 RPS/EPS Figure 3-11. Example of an 610 EPS ing Four Modules In this example there are four modules connected to the 610 EPS, therefore each module will be supplied with 204 watts of power to be distributed to each module s 24 ports at 8.5 watts per port. Source of External Supply Watts Available 204/each module # of Ports ed and Average Watts/Port 24 @ average 8.5 W each None Redundant # of Ports ed and Average Watts/ Port Planning and Implementation 3-15

Planning and Implementation Infrastructure Requirements Infrastructure Requirements Air conditioning. supplies create a great amount of heat. Ensure you have enough cool air to maintain an ambient temperature between 0 C to 50 C (32 F to 131 F) around the switch devices inside the rack. requirements.ensure you have enough power supplied to the area where the switches will be mounted. Some units have dual power supplies in them that you may want to consider connecting each power supply to different circuits. Space. These devices may be deeper than other equipment in your network. Have enough space for the switch and around the switch to allow access and cool air circulation. If placing in an enclosed rack make certain there is adequate airflow and cooling through the rack. Racks. These devices may be heavier than other devices in your network. Rack heavy devices at the bottom of the rack, followed by lighter devices as you move up the rack. Secure racks as specified by your rack s manufacturer. Ensure your racks are compliant with any earthquake rules. Planning and Implementation 3-16

Glossary Glossary active port - -enabled port connected to a PD and currently delivering power. priority class - Refers to the type of power prioritization where the switch uses Low (the default), High, and Critical priority assignments to determine which groups of ports will receive power. Note that power priority rules apply only if provisioning on the switch becomes oversubscribed. EPS - External Supply PD - ed Device. This is an IEEE 802.3af-compliant device that receives its power through a direct connection to a 10/100Base-TX RJ-45 port on the switch. Examples of PDs include Voice-over-IP (VoIP) telephones, wireless access points, and remote video cameras. port-number priority - Refers to the type of power prioritization where, within a priority class, the switch assigns the highest priority to the lowestnumbered port, the second-highest priority to the second lowest-numbered port, and so-on. Note that power priority rules apply only if provisioning on the switch becomes oversubscribed. - -Over-Ethernet PSE - -Sourcing Equipment. A PSE, such as a Switch 2626-PWR or 2650- PWR, provides power to IEEE 802.3af-compliant PDs directly connected to 10/100Base-TX RJ-45 ports on the switch. The Switch 2626-PWR, 2650- PWR and the Switch xl Module are endpoint PSEs. Glossary Gloss-1

This page is intentionally unused.

Index Numerics 600 RPS/EPS external power supply 2-3 operation 2-1 redundant power characteristics 2-2 redundant power supply 2-2 610 EPS external power allocation 2-3 operation 2-1 C cable data pairs 1-3 power through 1-3 spare pairs 1-3 class method priority 2-6 E EPS allocation 2-3 EPS power 1-5 example configurations 3-2 I Introduction 1-1 L line loss power loss 2-7 M maximum power 2-4 minimum watts 3-2 O overview 1-1 P PDs power classification 2-7 planning 3-1 1-1 capabilities product capabilities 1-4 power with and without EPS 2-5 power, maximum 2-4 port priority 2-6 power loss 2-7 power over Ethernet 1-1 power requirements 3-2 power sourcing equipment 1-3 powered device 1-3 powered devices 3-2 priority, class method 2-6 priority, port 2-6 ProCurve Switch xl Module 1-5, 2-1, 2-3 R redundant switch power 2-2 RPS, operating characteristics 2-2 S switches 2626-PWR, 2650-PWR, 2600-8-PWR, Series 2600- PWR Switches 1-4 U Using External Supplies 2-1 X xl module configurations 3-11 xl module, EPS 2-3 xl module, power 2-3 Index Index 1

This page is intentionally unused.

This page is intentionally unused.

This page is intentionally unused.

Technical information in this document is subject to change without notice. Copyright 2001, 2005 Hewlett-Packard Development Company, L.P. Reproduction, adaptation, or translation without prior written permission is prohibited except as allowed under the copyright laws. Printed in Taiwan September 2005 Manual Part Number 5991-2167 *5991-2167*