SOLID PHASE REVERSIBLE IMMOBILIZATION HIGH PERFORMANCE NUCLEIC ACID ISOLATION AND PURIFICATION



Similar documents
BR-10150B. Bringing power and flexibility down to size. BIOMEK NX LABORATORY AUTOMATION WORKSTATION

AxyPrep TM Mag PCR Clean-up Protocol

Automated High Throughput Purification of BigDye TM Terminator Fluorescent DNA Sequencing Reactions Using Wizard MagneSil TM Paramagnetic Particles

ZR-96 DNA Sequencing Clean-up Kit Catalog Nos. D4052 & D4053

How To Get Rid Of Small Dna Fragments

Agencourt AMPure XP. Xtra Performance Post-PCR clean UP

ZR DNA Sequencing Clean-up Kit

Automated Nucleic Acid Extraction WorkStation Faster, cleaner,

Multiplex your most important

Protocol v001 Page 1 of 1 AGENCOURT RNACLEAN XP IN VITRO PRODUCED RNA AND CDNA PURIFICATION

Industrial Robotics Solutions

Agencourt RNAdvance Blood Kit for Free Circulating DNA and mirna/rna Isolation from μL of Plasma and Serum

ab Hi-Fi cdna Synthesis Kit

Application Guide... 2

How To Use An Enzymatics Spark Dna Sample Prep Kit For Ion Torrent

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

FOR REFERENCE PURPOSES

User Manual. CelluLyser Lysis and cdna Synthesis Kit. Version 1.4 Oct 2012 From cells to cdna in one tube

Maxwell 16 Blood DNA Purification System

RealLine HCV PCR Qualitative - Uni-Format

Mir-X mirna First-Strand Synthesis Kit User Manual

Genomic DNA Clean & Concentrator Catalog Nos. D4010 & D4011

PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System) 50 preps Product #60200

TaqMan Fast Advanced Master Mix. Protocol

Introduction To Real Time Quantitative PCR (qpcr)

Cell Discovery 360: Explore more possibilities.

The Thermo Scientific KingFisher Family

UltraClean Forensic DNA Isolation Kit (Single Prep Format)

Materials and Methods. Blocking of Globin Reverse Transcription to Enhance Human Whole Blood Gene Expression Profiling

ab Protein Sumoylation Assay Ultra Kit

ncounter Gene Expression Assay Manual Total RNA and Cell Lysate Protocols

UltraClean Soil DNA Isolation Kit

Molecular Assessment of Dried Blood Spot Quality during Development of a Novel Automated. Screening

Validation Guide for the DNA IQ Reference Sample Kit for Maxwell 16 Printed in USA. 9/06 Part# GE181

Essentials of Real Time PCR. About Sequence Detection Chemistries

Real-Time PCR Vs. Traditional PCR

PreciseTM Whitepaper

Troubleshooting Sequencing Data

A Novel Bioconjugation Technology

ExpressArt Bacterial H-TR cdna synthesis kit. With extreme selectivity against rrnas

ONLINE SUPPLEMENTAL MATERIAL. Allele-Specific Expression of Angiotensinogen in Human Subcutaneous Adipose Tissue

Path-ID Multiplex One-Step RT-PCR Kit

MLX BCG Buccal Cell Genomic DNA Extraction Kit. Performance Characteristics

How To Get A Cell Print

Automation in genomics High-throughput management of biological samples and nucleic acids. Valentina Gualdi Operational Scientist PGP

QIAsymphony RGQ Protocol Sheet

The GeneAmp PCR System Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

Isolation of Total RNA from Cultured Cells

50 g 650 L. *Average yields will vary depending upon a number of factors including type of phage, growth conditions used and developmental stage.

FastLine cell cdna Kit

U.S. Patent No. 9,051,563 and other pending patents. Ver

amplification tech Optical Design of CFX96 Real-Time PCR Detection System Eliminates the Requirement of a Passive Reference Dye

HBV Quantitative Real Time PCR Kit

Kevin Bogart and Justen Andrews. Extraction of Total RNA from Drosophila. CGB Technical Report doi: /cgbtr

Absolute Quantitation Using Standard Curve Getting Started Guide

Genomic DNA Extraction Kit INSTRUCTION MANUAL

Genolution Pharmaceuticals, Inc. Life Science and Molecular Diagnostic Products

UltraClean PCR Clean-Up Kit

Automated Library Preparation for Next-Generation Sequencing

Lab 10: Bacterial Transformation, part 2, DNA plasmid preps, Determining DNA Concentration and Purity

RealStar HBV PCR Kit /2012

Automation in Genomics High-throughput purification of nucleic acids from biological samples. Valentina Gualdi Operational Scientist PGP

Gene Expression Assays

SmartFlare RNA Detection Probes: Principles, protocols and troubleshooting

TransIT Transfection Reagent

Updating the QIAcube operating software

SEQUENCING. From Sample to Sequence-Ready

Recommended Procedures for the Extraction of RNA. Jan Pedersen USDA, APHIS, VS, National Veterinary Services Laboratories, Ames, IA 50010

FULLY AUTOMATED AND VALIDATED HIGH VOLUME DNA EXTRACTION USING CHEMAGEN MAGNETIC BEADS BASED KITS

360 Master Mix. , and a supplementary 360 GC Enhancer.

Sequencing Guidelines Adapted from ABI BigDye Terminator v3.1 Cycle Sequencing Kit and Roswell Park Cancer Institute Core Laboratory website

Creating Standard Curves with Genomic DNA or Plasmid DNA Templates for Use in Quantitative PCR

DNA IQ System Database Protocol

Classic Immunoprecipitation

Wizard DNA Clean-Up System INSTRUCTIONS FOR USE OF PRODUCT A7280.

BigDye Terminator v3.1 Cycle Sequencing Kit. Protocol. DRAFT August 27, :32 pm, A_v3.1Title.fm

Sanger Sequencing: Sample Preparation Guide

Hepatitis B Virus. genesig Advanced Kit. DNA testing. Everything... Everyone... Everywhere... Core Protein Region. 150 tests.

Real-time quantitative RT -PCR (Taqman)

DP419 RNAsimple Total RNA Kit. RNAprep pure Series. DP501 mircute mirna Isolation Kit. DP438 MagGene Viral DNA / RNA Kit. DP405 TRNzol Reagent

QIAGEN Supplementary Protocol

LightCycler 480 Real-Time PCR System

Absolute Quantification Getting Started Guide

First Strand cdna Synthesis

Building Technologies

Arcturus PicoPure RNA Isolation Kit. User Guide

MystiCq microrna cdna Synthesis Mix Catalog Number MIRRT Storage Temperature 20 C

Introduction to Post PCR Cleanup

ID kit. imegen Anchovies II. and E. japonicus) DNA detection by. User manual. Anchovies species (E. encrasicolus. sequencing.

Procedures For DNA Sequencing

Mir-X mirna First-Strand Synthesis and SYBR qrt-pcr

Global MicroRNA Amplification Kit

Evalution the multiplexed analysis of biomarkers made fast and simple by MyCartis

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

History of Innovation

Epstein Barr Virus (Human Herpes virus 4) genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere...

BacReady TM Multiplex PCR System

Easy Collection and Extraction of BioSamples Ahlstrom GenCollect Ahlstrom GenCollect Color

Efficient Multi-Well Protein Purification Strategies

Transcription:

R-BR5Y94 Agencourt SPRI Technology with Beckman Coulter Automation SOLID PHASE REVERSIBLE IMMOBILIZATION

SOLID PHASE REVERSIBLE IMMOBILIZATION What Agencourt SPRI Is Solid Phase Reversible Immobilization (SPRI ) is a patented, magnetic bead-based high performance nucleic acid purification technology invented at the Whitehead Institute (Hawkins, et al. Nucleic Acids Res. 1995; 23:22). SPRI is used by many pharmaceutical, biotechnology, academic and government organizations performing life science research. How Agencourt SPRI Works Targeted nucleic acids are immobilized onto paramagnetic microparticles using specific buffer conditions. The paramagnetic particles adhere to the walls of the vessel while sample contaminants are easily removed. There is no need for centrifugation or filtration thus creating a streamlined and scalable format optimized on the Beckman Coulter Biomek FX, NX, and 3 workstations including the ArrayPlex application. Why Agencourt SPRI Works The bead s high uniformity imparts reproducible performance characteristics. The production process utilizes very small particles of fully formed magnetite that are layered onto the polystyrene core particle. As a result, the beads retain little residual magnetism when not subjected to a magnetic field, which prevents clumping and falling out of solution. Their 4% iron content gives the beads a very quick magnetic response time so that they are easily and effectively separated from solution in a tube or microplate. The functionalized polymer coating and small bead size give them a high non-specific binding capacity for nucleic acids. What Agencourt SPRI Can Do For You Your time is precious. Your budget is limited. Agencourt SPRI technology can automate your sample preparation needs for almost any nucleic acid purification. Automating Agencourt SPRI technology delivers performance and value like no other nucleic acid purification technology. From saving thousands of dollars in operational budget costs for sequencing labs to streamlining workflow processes for gene expression customers, SPRI technology fits where you need it. Agencourt SPRI Methodology: A typical SPRI protocol is fast and easy, involving only a few simple steps. Step 1: Nucleic acid immobilization SPRI beads are directly added to sample reactions. Nucleic acids are selectively immobilized onto SPRI beads, leaving contaminants in solution. Step 2: Contaminant removal A magnetic field is used to pull the microparticles out of solution. Contaminants are aspirated and microparticles are thoroughly washed, yielding high quality nucleic acids. Step 3: Nucleic acid elution Purified nucleic acids are easily eluted from the microparticles under aqueous conditions, which provides maximum flexibility for downstream applications. Magnet Magnet AUTOMATION PERFORMANCE VALUE 2

Software Automation Methods Beckman Coulter offers a suite of automation methods designed for Agencourt SPRI-based reagents. SPRI is ideal for automation because it does not require centrifugation or vacuum filtration, both of which necessitate manual intervention. All methods are supplied with supporting documentation and are compatible with Windows NT, 2 and XP operating systems, depending on instrumentation manufacturer requirements. Automation methods are currently available for the Beckman Coulter Biomek FX and NX workstations in select 96-well, 384-well, Span 8 automation configurations, and the Biomek 3. SOLID PHASE REVERSIBLE IMMOBILIZATION Intuitive Application Specific User-Interface Agencourt software methods were created with a Windows-based graphical interface allowing users to easily personalize methods. Flexible easy-to-use features such as: Pre-programmed conditions for optimal processing All purification variables on a single dialog box Ability to change parameters with the click of a button Recollection of conditions from the previous run Incubation timer with expire button and countdown display Speed optimized for maximized throughput Use of disposable tips and tip wash-station to reduce consumable costs Optional PerkinElmer PlateStak integration Adjust parameters such as reaction volume with the click of a button. Biomek Automation Plates per Hour Application Kit FX NX Agencourt SprintPrep Single Step Plasmid Purification (with PlateStak 1 ) FX/NX Span 8 3 96-well 384-well up to 8 up to 8 Low and High Copy Plasmid Purification Agencourt CosMCPrep up to 18 DNA Sequencing Dye-Terminator Removal Agencourt CleanSEQ (with PlateStak) Buccal Cell gdna Isolation Agencourt Orapure gdna from Whole Blood/Serum Agencourt Genfind.5 PCR Clean-up and Purification Agencourt AMPure (with PlateStak) Total RNA Isolation from Cells Agencourt RNAPrep 2.5 Gene Expression Post cdna Purification and Post IVT RNA Purification Agencourt up to 4 Buccal Cell gdna Isolation Agencourt Orapure SNP Genotyping gdna from Whole Blood/Serum PCR Clean-up and Purification Agencourt Genfind Agencourt AMPure (with PlateStak).5 3 AUTOMATION PERFORMANCE VALUE

SOLID PHASE REVERSIBLE IMMOBILIZATION Drug Discovery and Development Beckman Coulter s Agencourt chemistry not only fits into individual research lab processes, but also the drug discovery and development pipeline. From target identification to clinical development, Agencourt chemistry coupled with the Beckman Coulter automation product line is a top-notch solution for a variety of applications, enhancing the productivity, results, and economics of your research. Downstream Application: DNA Sequencing Boost your productivity, quality of base calls, and dye terminator utilization with a fully automatic clean-up protocol. Recommended Products: Agencourt CleanSEQ for post-sequencing reaction clean-up, Agencourt AMPure for isolation of gdna from PCR* products. ABI 1 PRISM 1 373xl RFU 6 5 4 3 2 1 Reduced BigDye Concentrations Agencourt CleanSEQ Edge Performa DTR 1/4 1/8 1/16 1/32 BigDye Dilution 3 µl of amplified PCR* product: TP53_exon 5 was run in a 2 µl sequencing reaction and purified with Agencourt CleanSEQ and Edge Biosystem s 1 Performa DTR 1. Downstream Application: SNP Genotyping Increase your gdna isolation recovery with a fully automated protocol, and get more experiments from your precious samples. Recommended Products: Agencourt AMPure for isolation of gdna from PCR products, Agencourt Genfind for isolation of gdna from whole or frozen blood and/or serum. Total Yield (µg) Average DNA Yield from 2 µl Human Blood Preserved with EDTA 2 15 1 5 Agencourt Genfind Qiamp 1 MagneSil 1 ChargeSwitch 1 Comparison of gdna yields from 2 µl of fresh human blood preserved with EDTA using Agencourt Genfind and competitor kits. Results shown are the average and standard deviation from three preparations. All isolations were performed according to manufacturers protocol. DNA was quantified using the Quant-iT 1 PicoGreen 1 ds DNA Assay kit (Invitrogen). Kit Fresh Frozen Downstream Application: Gene Expression via Microarray With an automated platform that performs cdna and IVT clean-up, as well as RNA isolation from tissues and cells, you can enhance your productivity and RNA recovery, especially when your sample is scarce. This system is so effective that Gene Logic recommends it (see case study, next page) and Affymetrix endorses Agencourt chemistry for sample preparation on the GeneChip Array Station. Recommended Products: Agencourt for cdna and IVT clean-up, Agencourt RNAPrep for isolation of total RNA from cells. Yield (µg) 14 1 8 6 4 2 Affymetrix Protocol RNeasy Clean-up Method Enzo IVT Protocol RNeasy Comparison of crna Purification Methods.** Agencourt is effective in two popular methods for producing crna for microarray analysis. Five micrograms of rat brain RNA was used in crna labeling kits from Affymetrix and Enzo 1. IVT incubation time was 8 hours. Key: cdna clean-up method/crna clean-up method. * The PCR process is covered by patents owned by Roche Molecular Systems, Inc., and F. Hoffman-La Roche, Ltd. ** Testing performed by Gene Logic, Inc. AUTOMATION PERFORMANCE VALUE 4

Case Study: Gene Logic Gene Logic 1, based in Gaithersburg, Maryland, is one of the world s largest Affymetrix 1 users. They perform gene expression research and provide the resulting data for their pharmaceutical clients, therefore they demand the highest data quality. SOLID PHASE REVERSIBLE IMMOBILIZATION Problems Identified Historically, Gene Logic has used PLG tubes for clean-up of cdna reactions and RNeasy 1 for clean-up of IVT reactions which resulted in the following issues: Single tube formats are very labor intensive, resulting in slow throughput QIAGEN RNeasy contains caustic chemicals requiring technicians to work under a hood Results varied due to precipitation step with PLG Process was not automation-friendly or scalable without additional costs and resources Solution Implemented Agencourt improved upon this process. By using Agencourt and automation, single tubes were eliminated in favor of a 96-well format. Results were less variable, technicians did not need the use of a fume hood, yields were increased, and costs were decreased, all while maintaining consistent or higher quality downstream data. IVT Yield (µg) IVT Yields From Different Clean-up Methods 11 1 9 8 7 6 5 4 3 2 1 RNeasy Clean-up Method (cdna/ivt) PLG/RNeasy (Control) IVT yields are greater when using Agencourt for both cdna and IVT reactions as compared to other methods. IVT Yield (µg) Reproducibility - Human Spleen RNA 2 µg Input 1 8 6 4 2 1 14 27 4 53 66 79 92 Sample Number 1 to 96 By using the Agencourt kit, reproducibility and high yield are demonstrated in a 96-well format with 2 µg of human spleen RNA per well. % Present Calls 7 6 5 4 3 2 1 Present Calls Control Alt Method 1 2 3 4 5 6 Control 1 Control 2 Control 3 Control 4 Control 5 Control 6 Alt 1 Alt 2 Alt 3 Alt 4 Alt 5 Alt 6 Downstream data remains unaffected as the Present Calls are constant among the clean-up methods. 5 AUTOMATION PERFORMANCE VALUE

SOLID PHASE REVERSIBLE IMMOBILIZATION Reduce bottlenecks with a high-throughput, low-cost solution. Agencourt CleanSEQ has allowed us to completely automate our sequencing reaction clean-up step to produce very high quality Phred scores compared to our previous clean-up method. As a result, we streamlined the clean-up procedure and saved valuable time on analysis, all of which helped reduce the overall costs of the project. MARGARET ROBERTSON, ERNEST GALLO CLINIC & RESEARCH CENTER How Agencourt SPRI Can Save Money A typical sequencing lab annual budget before and after using Agencourt CleanSEQ is shown below. The overall operating cost can be substantially reduced by using Agencourt CleanSEQ. The first pie shows 2, reactions per year, with a dye-terminator volume of 4 µl/reaction and a reagent cost of $.6/reaction resulting in a $554,4 annual budget cost. The second pie shows the same number of reactions with the same labor cost. However, by incorporating Agencourt CleanSEQ and a Beckman Coulter Biomek FX, the resulting package brings the annual operating budget down to $4,993 a savings of $141,47!* Estimated Current Annual Expenditure 4 µl Big Dye 1 per Reaction Year One Annual Expenditure Using Agencourt CleanSEQ Kit.5 µl Big Dye per Reaction $143,64 $86,4 $143,64 $228,853 $324, $4,5 Total Dye Terminator Cost Total Reagent Cost Labor Cost Before - Total Expenditure = $554,4 Total Dye Terminator Cost Total Reagent and Robotics Cost Labor Cost After - Total Expenditure = $4,993 *Assumptions: Labor is assumed constant at 35% of overall reagent cost.this will vary from lab to lab and may decrease due to the automation component of the technology. In this example, dye-terminator cost is $4.5/reaction. Intuitive methods, improved signal, reduced turnaround time. My lab easily incorporated Agencourt CleanSEQ into our protocols using the automation methods, without prior robotics experience. The improved signal strength allowed us to cut our sequencing reagent costs and to dramatically speed up data return. DAVID REYNOLDS,DIRECTOR DNA SEQUENCING,GENOTYPING, AND AFFYMETRIX FACILITIES ALBERT EINSTEIN COLLEGE OF MEDICINE AUTOMATION PERFORMANCE VALUE 6

DNA Purification Agencourt CleanSEQ Dye Terminator Removal Agencourt AMPure PCR Clean-up and Purification Agencourt SprintPrep Single Step Plasmid Purification Agencourt CosMCPrep Low and High Copy Plasmid Purification Agencourt Orapure Buccal Cell gdna Isolation Agencourt Genfind gdna from Whole Blood and Serum RNA Purification Agencourt RNAPrep Total RNA Isolation from Cells Agencourt Post cdna Purification and Post ivt RNA Purification 1 All trademarks are the property of their respective owners. Agencourt Bioscience Corporation, A Beckman Coulter Company 8-361-778 www.agencourt.com 5 Cummings Center, Suite 245 Beverly, Massachusetts 1915 Worldwide Offices: Australia (61) 2 9844-6 Canada (95) 819-34 China (86) 1 6515 628 Eastern Europe, Middle East, North Africa (41) 22 994 7 7 France 1 49 9 9 Germany (31) 1 47 79 26 Hong Kong (852) 2814 7431/2814 481 Italy 2-953921 Japan 3-544-8359 Mexico (55) 56-5777 Netherlands (31) 1 47 79 26 Singapore (65) 6339 3633 South Africa, Sub-Saharan Africa (27) 11-85-214/5 Spain 91 38368 Sweden 8-564 85 9 Switzerland 8 85 81 Taiwan (886) 2 2378 3456 Turkey 9 216 39 19 U.K. 1494 441181 U.S.A. 1-978-867-26 5-275 26 Beckman Coulter, Inc. Printed in U.S.A.