»Synthetic air supply by WITT hygienic, safe, cost-effective!«



Similar documents
Medical Air Systems: Scroll

GAS CYLINDER SAFETY. 2. GRADES OF GASES BOC have divided the gases that they supply into 3 grades.

Reference in RID/ADR (restructured) to published standards and standards in preparation at CEN TC 23/256/261/268/286/296

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Program Summary. Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement

AUTOMATIC CHANGEOVER MANIFOLD Series 915

Battery Powered Digital Mass Flow Meters for Gases

German engineering under high pressure

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

NITROX // safer diving

Pipeline. Medical Gas Pipeline Products

Hydraulic control unit series

REGSON TM2 OXYGEN-THERAPY PRESSURE REGULATORS WITH FLOWMETER WITH PRE-ADJUSTED FLOWRATES MORE SAFETY GAS FLOW BETWEEN TWO POSITION

Car and commercial cial air conditioning service solutions

BRANCH SOLUTION. Automatic fire extinguishing systems for paint spraying plants. Safe for certain.

Rules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Micro Motion 3098 Gas Specific Gravity Meter

A Practical Guide to Free Energy Devices

Refrigeration Air Dryers ADQ. Capacity: m 3 /h

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

Infusion filters and filter systems I.V.STAR FILTER

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

AC Service Equipment ACE 21 EXPERT. Fully automatic service station. R-1234yf refrigerant. Made in Germany

Fully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop

Guide to good leak testing

Lockout Specification BW Clip Maintenance-free single gas detector

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Spare Parts Program. Parts, Consumables & Accessories superproductsllc.com

5162 E. Working in oxygen-reduced atmospheres BGI/GUV-I 5162 E. Information

Corona process The new ZEISS spectrometer system for the food industry

RITTER Multiple Sonic Nozzle Calibration System

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

CRAC Precision climate control units for data centres

The column to efficient care DRÄGER GEMINA DUO

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Description TERMINAL UNIT AFNOR NF S

Morrison Bros. Co. General Product Specifications

Type 3353 Angle Seat Valve

Atlas Copco. On-site Industrial Gases Nitrogen & Oxygen Generators

D Youville College July 31, 2008 New Academic Building Cannon Design Project No

HEAVY-DUTY HAND CUTTING TORCHES AND ACCESSORIES. Page 1 Version no.: V

Hilger u. Kern / Dopag Group

Compact Monitoring Technology your environmental monitoring solution

W&H Sterilizers. Made-to-measure precision and perfection. Totally type B

DEBSON TM2 OXYGEN THERAPY FLOWMETERS WITH PRE ADJUSTED FLOWRATES MORE SAFETY GAS FLOW BETWEEN TWO POSITION. English version 11/ 2 010

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

On-line Dissolved Gas Analysis

Ammonia Detection System Codes and Design Specifications

AUTOMOTIVE AIR CONDITIONING SYSTEM.

EXTENSION OF PERIODIC INSPECTION INTERVAL FOR LPG CYLINDERS

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Automatic Back-Flushing Filter AutoFilt RF9.

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Thermal Mass Flow Meters and Controllers for Gases

Armaturenwerk Hötensleben GmbH. AWH-Connect

Regulator Options and Accessories

INSTALLATION AND START UP REPORT CERTIFYING THE CORRECT FUNCTIONALITY OF THE AD HOC REFUELLING STATION LIFE+ MHYBUS LIFE 07-ENV/IT/000434

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Industrial Batteries North America

Hydraulic Control Solutions

QGA Quantitative Gas Analyser

EDITION 2/2013 CENTRAL GAS SUPPLY HIGH PRESSURE MANIFOLDS AND OUTLET POINTS FOR INDUSTRIAL GASES

ECHM Recommendations for Safety in multiplace medical hyperbaric chambers

COMBIMASS. Technical Data COMBIMASS eco-bio +

For over 40 years, the leader in. nitrous oxide. equipment technology.

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

T 300 Tray sealer. Automatic tray packaging in the smallest of spaces

ASALAIR BIOHAZARD CABINET MODEL ATLANTIC CYTOCABINET 1200 CLASS II TYPE A2 COD MICROBIOLOGICAL SAFETY CABINET CLASS II TYPE A2

Validation of process gas systems

ultrafilter VARIOBLO Heat Regenerated Adsorption Dryer

D Gas supply secure at a glance DRÄGER ALARM MANAGEMENT SYSTEM

Fundamentals of Mass Flow Control

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

The bridge to more efficient care PONTA SUPPLY BEAMS

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Chromatograph Maintenance and Troubleshooting Class # 5050

Digital inductive conductivity transmitter

Fully Automated Distillation of Petroleum Products including Biofuels OptiDist - the Optimal Solution

Element D Services Plumbing

Duplex Filters 40 FLDK 0008(C)-0120(C)

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

Combi switchbox with integrated 3/2 way pilot valve

DUST EMISSION MONITORING SYSTEM

MODEL LP 225LP2 225LP4 Safety Relief Valves

Please keep these operating instructions in a safe place.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

BR I Blood Bank Refrigerators

Kompressoren. Adsorption Dryer AD

Product-friendly and fast...

Installing a Probe. Typical Installation

Dräger Alcotest 9510 Evidential Alcohol Measuring Device

Module 5: Combustion Technology. Lecture 34: Calculation of calorific value of fuels

Transcription:

TECHNOLOGY FOR GASES»Synthetic air supply by WITT hygienic, safe, cost-effective!«[ RENÉ MARTIN: SALES & PROJECT MANAGER WITT ] The certified MED-MG for medical applications. Certified and approved as medical device class IIb CE marked according to Directive 93/42/EEC

MED-MG Synthetic air mixing system for medical applications 1 GASCONTROL 50 Central control unit Intuitive operation via touchscreen Log for 3000 data records 2 Double oxygen analyser Paramagnetic measuring cell 3 Double gas flow monitoring Safe supply of the oxygen analysis 4 Lockable door Protection of settings 5 Gas inlets Connections for oxygen and nitrogen supply 6 Alarm module Inlet pressure control Monitoring of control unit 7 Gauges for inlet pressures, receiver pressure, etc. 8 USB and Ethernet interfaces Comfortable data administration and analysis 4 3 2 2 3 1 8 6 8 7 5 Always up to date. Subscribe now. www.wittgas.com/newsletter_en

FUNCTIONS Medical applications, in particular, require high purity air. WITT gas mixing systems offer a solution for reliable production of synthetic air, a mixture of oxygen and nitrogen with a similar composition to the atmosphere. The gas mixing systems work oil- and fatfree and use pure gases from liquefied gas storage systems. Contrary to a compressor, an extensive and high maintenance processing, cleaning and drying of the air, is not necessary. With this solution, hospitals can achieve the highest air purity level for the protection of their patients and at the same time realise a very cost-effective central gas supply. Synthetic air mixers by WITT offer highest supply safety for central gas supply systems in hospitals. For decades, these systems have been used in many medical installations all over the world. The product generation MED-MG offers easy operation via touchscreen, low investment and maintenance costs, easy integration into existing systems and a low energy demand. Of course, the gas mixing systems meet highest quality and safety standards regarding construction, material and manufacture. Modern WITT gas mixing technology is the heart of the systems. The redundant design of all safety relevant components ensures full functionality at any time even in the case of possible interferences. Using two independent gas analysers guarantees the correct combination of oxygen and nitrogen. Pressure inlet control, gas flow monitors, pressure equalising system, solenoid valves as well as the continuous self control of the systems are additional safety features. If an error should occur, the system automatically switches to a parallel supply unit. An integrated data log continuously records all results and alerts. Via Ethernet interface, the mixer can be connected to networks and other systems. WITT synthetic air mixers are certified as medical devices and CE marked according to European Directive 93/42/EEC (added by Directice 2007/47/EC). They have been designed according to DIN ISO 7396-1. BENEFITS Easy operation via touchscreen Low costs for energy and maintenance Flexible synthetic air withdrawal from zero to maximum flow capacity (247 Nm 3 /h 8,722 scfh) Highest supply guarantee by redundant design of all relevant safety components High process safety by self monitoring of analysers with additional monitoring via an independent control unit Independent of pressure fluctuations in the gas supply by integrated pressure equalising system (BAM tested dome pressure regulators) Gas supply safety by inlet pressure monitoring Permanent availability by instant adjustment to fluctuating withdrawal In case of failure, automatic switch to a parallel system Integrated data log for full documentation Easy integration via USB or Ethernet connection Different models and outputs available Optional: Uninterrupted power supply (UPS) Heater Fully automatic calibration Certified and approved as medical device class IIb CE marked according to Directive 93/42/EEC

GASCONTROL 50 Active The GASCONTROL 50 works with a powerful processor and is the electronic control center of the MED-MG. The 4.3" colour TFT touchscreen allows intuitive operation of course password protected. The user always has an overview on the current status of the mixing system and gets informed in case of an alarm. All parameters can be set quickly and comfortably, e.g. individual limits or calibration functions. Always up to date. Subscribe now. www.wittgas.com/newsletter_en

SAFETY FEATURES The MED-MG is equipped with special parallel working control components to ensure highest supply safety. If one of those components detects a discrepancy and triggers an alarm, the solenoid valves at the gas mixer outlet and the receiver outlet close and the synthetic air supply gets interrupted. In this case, the systems send a signal which can activate a parallel supply system. CONCLUSION Hygienic, safe, cost-effective synthetic air supply by WITT for medical applications Parallel control systems with self monitoring The mixing system works with 2 parallel control units and one independent alarm module. A continuous monitoring ensures the error-free operation of the three safety components. The control units and the alarm module are monitored by each other (handshake concept). Paramagnetic oxygen analyser The oxygen concentration in the synthetic air is continuously monitored by two independent analysers. The analysers consist of a control unit, a paramagnetic measuring cell and a flow guard. If the minimum or maximum threshold limit is exceeded or the gas flow is too low, an alarm is triggered. Gas flow monitoring The sample gas flow is continuously monitored. In case the flow falls short of the pre-defined threshold, an alarm is triggered. Inlet pressure monitoring The inlet pressures of oxygen and nitrogen are monitored by pressure indicators. Inlet pressures over or below the threshold limits are displayed on the alarm module and the control units and trigger an alarm. Pressure equalising system The gas inlet pressures of nitrogen and oxygen are reduced to the operation pressure by means of an integrated pressure equalising system. In case of a supply pressure drop in the oxygen line, the nitrogen supply pressure will also be automatically reduced. This ensures a constant ratio in the gas mixtures. If the oxygen supply is interrupted, the nitrogen supply is also automatically stopped. Alarm Admin Certified and approved as medical device class IIb CE marked according to Directive 93/42/EEC

INSTALLATION EXAMPLE REFERRING TO DIN EN ISO 7396-1:2007 CHAPTER 5.5.3 Supply system 1 (Scope of delivery WITT MED-MG) Supply system 3 3 5 1 2 4 7 6 Supply system 2 (Scope of delivery WITT MED-MG) 3 8 5 4 1 2 6 1 2 3 4 5 6 7 8 9 Synthetic air mixer Receiver Integrated double oxygen analysis Solenoid valve Nitrogen supply Oxygen supply Compressor or cylinder bundle External oxygen analysis Central switch unit 9 Gas flow Data flow Always up to date. Subscribe now. www.wittgas.com/newsletter_en

CERTIFIED SAFETY Certified and approved as medical device class IIb CE marked according to Directive 93/42/EEC

TECHNOLOGY FOR GASES OUR PRODUCT RANGE Gas Control Equipment Gas mixing systems Gas metering systems Gas analysers Leak detection systems Gas pressure vessels Engineering of customised systems Gas Safety Equipment Flashback arrestors Non-return valves / check valves Quick couplers Safety relief valves Stainless steel devices Gas filters Pressure regulators Outlet points Lance holders Ball valves Automatic hose reels Test equipment Accessories Customised safety equipment V _ 11 / 2011 WITT-Gasetechnik GmbH & Co KG Salinger Feld 4 8 58454 Witten Postfach 2550 58415 Witten Deutschland Tel. +49 (0)2302 8901-0 Fax +49 (0)2302 8901-3 www.wittgas.com witt@wittgas.com WITT Gas Techniques Ltd. 212, Europa Boulevard Westbrook Warrington, WA5 7TN Great Britain Tel. +44 (0)1925 234466 Fax +44 (0)1925 230055 witt-uk@wittgas.com WITT FRANCE S.A.R.L. 131 Voie de Compiègne 91390 Morsang sur Orge France Tel. +33 (0)160 151779 Fax +33 (0)160 154782 witt-france@wittgas.com WITT Tecnología de Gas, S.L. C/Simón Cabarga N 2a Bajo 39005 Santander España Tel. +34 942 835142 Fax +34 942 835143 witt-espana@wittgas.com WITT Gas Controls LP 380 Winkler Drive, STE 200 Alpharetta, GA. 30004 USA Tel. +1 888 948 8427 Fax +1 877 948 8427 witt-usa@wittgas.com WITT POLSKA Sp. z o. o. ul. Legnicka 62 54-204 Wrocław Polska Tel. +48 (0)7135 22856/7 Fax +48 (0)7135 13113 witt-polska@wittgas.com WITT ITALIA Srl. Via Giovanni XXIII, 18 24030 Solza (BG) Italia Tel. +39 035 4933273 Fax +39 035 4948098 witt-italia@wittgas.com GUSTUS & PARTNER GmbH Installation Service Wartung Alt Salbke 6 10, Geb. 59 39122 Magdeburg Germany Tel. +49 (0)391 4015246 Fax +49 (0)391 4013296 gustus@wittgas.com Please contact us for partners in your country Always up to date. Subscribe now. www.wittgas.com/newsletter_en