Operating Instuctions. Shaking device SV 14 / 22 SV 29 / 45. page 1



Similar documents
Operating Instructions

WATERBATHS AND OILBATHS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Waterbaths and Oilbaths WNB/WNE/WPE/ONE

Cable Plug acc. to DIN EN , Form A

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

3/2- and 2/2-way cartridge valve type BVE

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Assisted lift operated 2/2-way solenoid valves Type EV250B

Operating instructions Platform/floor scales

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Solenoid valves Type EVU

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

3/2-way Solenoid Valve, direct-acting, NC or NO

LC/LCD ranges level controllers

Sterilizers with extra class

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Operating Instructions. Room temperature controller

Instruction Manual Differential Pressure Transmitter

Operating Instructions for Plastic Flow Meter. Model: KSK

HOSCH. Sprung blade scraper with heating system. Documentation Type B6C/H

How To Use A Flowmeter

Operating instructions

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

MELA quick 12+ Compact. Fast. Strong.

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

DALI RC BASIC SO. Control unit Operating instructions

OPERATING INSTRUCTIONS Humidity Chambers HCP 108 HCP 153 HCP 246

Electric Rotary Actuator - On/Off or programmable control actuator

4 Posiflow Proportional Solenoid Valves

Electronic Pressure Switch EDS 300

USB/RS485 converter cable, complete

Proportional pressure regulators VPPE

Linear actuator Econom 0. Our intelligent model: Econom 0. Econom 0

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Combi switchbox with integrated 3/2 way pilot valve

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Operations Manual Blast Chiller

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

OPERATING INSTRUCTIONS UM SM ULM/SLM /99

Series description: Wilo-Star-Z

ROTOFIX 32 A Benchtop Centrifuge

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

GF SERIES 1-TANK/2-TANK ELECTRIC FRYER USER S MANUAL

Catalogue Wilo- Stratos PARA

Electronic Pressure Switch EDS 3000

SITRANS F flowmeters SITRANS F M

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Drayton Digistat +2RF/+3RF

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

RRV934. Multi-controller. Synco living

HERZ-Thermal Actuators

HYDRUS ULTRASONIC METER

OPERATING MANUAL. Climatic test chamber CTC 256 Temperature test chamber TTC 256

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Pluggable interface relays CR-P Pcb relays

CRK A-W-A-BUBV

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING

Manual v1 Page 1 of 17. Manual. Laboratory autoclave

Danfoss Link Mobile Phone Butler

Residual current socket 30mA Order No.:

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

SVR 12/24V and SVR Akku 12V Installation instructions

Operating Instructions W401

Thermistor motor protection

Actuator for modulating control AME 435

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

RM4TG20 three-phase network control relay RM4-T - range V

ST Series POWER SUPPLIES USER INSTRUCTIONS

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Electro-hydraulic pressure switches type DG

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

Freezers - Ultrafreezers. Platilab & Irilab Series

System 8. ü ( System 8

WATER BATH. Art. No /115/1400 (115 V) 35097/230/1400 (230 V) OPERATING INSTRUCTIONS. User information: Water bath Teflon mesh

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

PHOENIX CONTACT Features

Shaking water bath OLS200 Refrigerated immersion cooler CS200G

Electronic Pressure Monitoring New Products

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Conductive Level Switch FK 2 Technical Data:

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

MINI MCR-SL-R-UI(-SP)

Shaking Water Baths THERMOLAB

SOLENOID VALVE FOR REFRIGERATING SYSTEMS

Digital inductive conductivity transmitter

Transcription:

Operating Instuctions Shaking device SV 14 / 22 SV 29 / 45 page 1

General notes, safety notes, notes on electrical equipment and electromagnetic compatibility, as well as notes on maintenance of the unit are to be found in the Operating Instructions for the waterbath. Brief technical description The shaking device permits controlled shaking of beakers or test tubes in a waterbath. The shaking device performs a reversing linear movement with a frequency of approx. 35 to 160 strokes per minute. The shaking speed is controlled electronically and can be adjusted in 10 speed steps. The stroke is approx. 15 mm. The ambient conditions for its operation are the same as for the basic units. Inserting and removing The bath can be operated without shaking device if required. After the shaking device and the support basket has been removed, the side panel supplied should be secured to the gable cover by means of the two screws in orded to ensure optimum sealing of the cover. Fitting the shaking device has to take place in the reverse order. Safety note If the shaking device has to remain in a waterbath that is switched on, it has to remain switched on as well! The shaking speed can be set to a standstill! When being switched off, the overpressure steam blockage is out of action and condensate may pass into the housing of the shaking device! page 2

Starting up Mains supply The mains cable must be arranged so that it can not come anywhere into contact with hot surfaces of the unit. Filling the waterbath Max. level Min. level In order to protect the stainless steel shaking device it is necessary to use deionised water as the thermofluid. The bath must be filled so that the liquid level is between the two level marks on the right inside the tank (with the shaking device carrying its load)! Note! Depending on the loading of the shaking device and the shaking speed selected, it is possible for the bath liquid or the (possibly noxious) shaken liquid to slop over. In that case the shaking speed or the liquid level have to be suitably adjusted but without going below the minimum liquid level. Switching on and setting the shaking speed The unit is switched on by pressing the push/turn control. The for operation. symbol indicates that the unit is ready Unit is switched on. Fault: overload/ blockage Shaking device ready for operation Shaking speed SET key push/turn control Unit is switched off. After the shaking device has been switched on, the setpoint for the shaking speed is always set to 0 strokes per minute. The shaking speed is selected by rotating the push/turn control while holding down the SET key. Bar dark approx.: Bar bright approx.: 35 65 90 120 145 50 80 105 130 160 strokes per minute Quick stop on overload The unit incorporates a quick stop on overload as a safety device. Operation of this safety device can be recognised by the symbol lighting up. In this case it is necessary to check whether there is any overloading or whether some object has been trapped in the system. After the overload has been removed, the shaking device can be restarted by briefly pressing the SET key and setting the shaking speed again. page 3

EC Declaration of Conformity Manufacturer s name and address: MEMMERT GmbH + Co. KG Äußere Rittersbacher Straße 38 D-91126 Schwabach Product: Shaking device Type: M00 / M01 Sizes: SV 14-22 / SV 29-45 Nominal voltage: AC 230 V 50/60 Hz alternative AC 115 V 50/60 Hz The designated product is in conformity with the European EMC-Directive 2004/108/EEC including amendments Council Directive of 03 May 1989 on the approximation of the laws of the Member States relating to electromagnetic compatibility. Full compliance with the standards listed below proves the conformity of the designated product with the essential protection requirements of the above-mentioned EC Directive: DIN EN 61326:2004-05 EN 61326:1997 EN 61326/A1:1998 EN 61326/A2:2001 EN 61326/A2:2003 The designated product is in conformity with the European Low Voltage Directive 2006/95/EEC including amendments Council Directive on the approximation of the laws of the Member States relating to Electrical equipment for use within certain voltage limits. Full compliance with the standards listed below proves the conformity of the designated product with the essential protection requirements of the above-mentioned EC Directive: DIN EN 61 010-1 (VDE 0411 part 1):2002-08 EN 61 010-1:2001 DIN EN 61 010-2-010 (VDE 0411 part 2-010):2004-06 EN 61 010-2-010:2003 Schwabach, 03.07.08 (Legally binding signature of the issuer) This declaration certifies compliance with the above mentioned directives but does not include a property assurance. The safety note given in the product documentation which are part of the supply, must be observed. page 4

Notes: page 5

Notes: page 6

Notes: page 7

31.07.2009 Schüttelvorrichtung englisch page 8 D10337