Contents. Document information

Similar documents
Modular I/O System Analog and Digital Interface Modules

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Kit Watt Audio Amplifier

Nokeval. User's Manual Models 301 / 302 / 305

Duct Humidity Transmitter

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

INSTRUCTION MANUAL. SIGNAL AMPLIFIER 4-20 ma

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

Differential Charge Amplifier

FEMA ELECTRÓNICA. Serie ISC SIGNAL CONVERTERS WITH GALVANIC ISOLATION. MODEL ISC-IAC for AC Currents ISC-IDC for DC Currents USER S MANUAL

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

EXTERNAL DIMENSIONS AND PARTS

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

Telefon (+45) Telefax (+45) Installation and operating manual

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

T7560A,B,C Digital Wall Module

Digital Pressure Measuring Instrument MDR480

PIN CONFIGURATION FEATURES ORDERING INFORMATION ABSOLUTE MAXIMUM RATINGS. D, F, N Packages

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Inductive sensor NI10-M18-Y1X-H1141

MINI MCR-SL-R-UI(-SP)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

AC3200 INTELLIGENT BROADBAND AMPLIFIER

DLP-PU/E Instruction Manual

Quick Connect. quick - simple - efficient.

SYSTEM 4C. C R H Electronics Design

Plena Two-zone Call Station. Installation and User Instructions PLE-2CS

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

VOIP-500 Series Phone Quick Installation Guide

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Model: DC-A2IO Advanced HVAC Controller

T0118 T2118 T3118. Instruction Manual

Talon and Talon SR User Manual

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

2002 IS Catalog. Page

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

PRODUCT PROFILE FEATURES

MODEL 2202IQ (1991-MSRP $549.00)

ATL Fuel Level Sender Probes

SELECTION GUIDE. Nominal Input

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

Digital Expansion Modules Specifications

Liquid Leakage Sensor Amplifier

Analog signal converters CC-E I/I Current / current isolators

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

CX Zoner Installation & User Guide

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

2 X 250Watt Class D Audio Amplifier Board IRS2092 User s Guide

Adjustment functions for both span and shift have been incorporated

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

SX460. Generator Automatic Voltage Regulator Operation Manual

ABB Drives. User s Manual HTL Encoder Interface FEN-31

INSTRUCTIONS FOR USE Pro-Ject Tube Box S

IO-RM3 3-Stage Relay Module

SCXI CHANNEL ISOTHERMAL TERMINAL BLOCK

Model SRMD Setra Remote Monitoring Display

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Absolute Rotary Encoder E6CP

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

MLC TM Maximum Productivity and Versatility for Control without Compromise!

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

LAUBE TECHNOLOGY DRY REED RELAYS

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Ground Resistance Clamp On Tester

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Current Loop Tuning Procedure. Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) General Procedure AN-015

Temperature Transmitters ZTT series

Preset Counter signo 721

Analog Servo Drive 25A8

LOXONE 12 Channel Amplifier

Application Note TMA Series

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Combustible Gas Transmitter RK-05

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

DCS Input/Output Relay Card Series

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

TECHNICAL DATASHEET #TD1000AX DUAL SOLENOID MULTIFUNCTION VALVE DRIVER With Joystick, Potentiometer and Control System Interface P/N: DSDA-SMB Series

Pressure Transducer to ADC Application

PowerAmp Design. PowerAmp Design PAD135 COMPACT HIGH VOLATGE OP AMP

TEP 200WIR Series, Watt

Series DFMT Digital Paddlewheel Flowmeter

Transcription:

User Manual

Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB Versions:.0.1 Document Type: manual Document ID: 3120 Document Version: 2 Document Date: 1.3.201 Document information 2

Introduction is a 3way galvanic isolator and signal converter, which is designed for ma, V and mv inputs and outputs. Galvanic isolation is the best way to cut noise paths to the measurement amplifier and to prevent problems due to potential differences. is more versatile replacement for obsolete 60 device. Warnings Always use shielded signal cables. If possible, install devices to a metal box. If the power supply line carries inductive spikes, reduce them with ferrite clamps. Do not cover the ventilation holes. Oy Rounionkatu 107 FI3710 Nokia Finland Phone 383 32 800 (MonFri 8:3016:00) WWW http://www.nokeval.com/ Email sales@nokeval.com, support@nokeval.com Manufacturer 3

Description General information has been designed for several types of signal conversions. The device can be used to separate the input and the output galvanically and also simultaneously perform signal conversions. The input can be ma (current), V or mv (voltage) and bipolar forms of these (for example 10 10 V) or of potentiometer type. The output can be ma (current) or V (voltage) and bipolar forms of these (for example 10 10 V). Several common examples of usage: 20 ma current input signal can be converted to 0 10 V voltage output signal or vice versa, bipolar ±10 V voltage input signal can be converted to 0 10 V voltage output signal or vice versa, small mv input signals can be converted to standard signals. A 2wire transmitters operating with a 20 ma loop, like a pressure or level sensor and for example 620S, 670, 680 or 6720 devices, can be connected directly to a device without a separate power supply. itself needs a 2 VDC power supply to operate. This power supply line is galvanically isolated from the input and the output circuits. The range is changeable by DIPswitches and adjusted with the front panel potentiometers. Signal damping is possible by setting signal filter to a desired filtering speed, whose time constant can be chosen among 100 µs, 1 ms, 10 ms, 100 ms (default), or 1 s. Special ranges requiring design work or component assembly changes are priced a little higher than devices delivered at default ranges.

Connection Installation Install to a DIN rail in a way that the text on the front panel is readable. Unscrew screw terminals that are needed and connect wires one by one while tightening their screw terminals. On the right side there is a picture about screw terminal numbering and below are some examples of connections. The rule of thumb for the screw terminal numbering is to read the numbers like this text starting from top left and ending to bottom right. Screw terminal 1 can be used to provide a 1 VDC supply for an external device. Screw terminals 3 and 6 are internally connected to each other starting from V.0, so they can be used to replace each other. The wires used should be twisted pair type like illustrated by wires alternating from side to side in the drawn examples of connections. Power supply 2 VDC 12 12

6 Current input from active transmitter Current input from 2wire transmitter 1 1 Voltage input 6 3 6 POT (potentiometer input 00 ohm...100 kohm) 2 2

Active current output 7 8 7 8 Voltage output (also mv output) 10 11 10 11 This way the output load can be raised up to 1000 ohms: Power supply 2 VDC 12 8 11 8 11 12 7

In this mode the output load can be raised all the way up to 2000 ohms by using a separate power supply. However care has to be taken that the output stage power dissipation does not exceed 0. watts. Output Power supply Power supply 2 VDC 12 8 VDC 12 8 11 8 11 12 8

Configuration will be delivered configured to the range ordered by the customer. In this document, range refers to the combination of the input and output signals and their ranges. Range can be changed according to the following instructions. Return all the DIP switches to the OFF position, use the DIP switches SW1, SW2, SW3, SW, SW, SW6, SW7, and jumper JP1 for coarse adjustment of the output. For example: 7.2 in the tables below means ON position for the second switch in SW7. Set the desired damping by using switches 1, 2, and 3 of DIP switch SW. The factory default is 100 ms. Connect to the calibrator device and supply input low and high values in turns in a way that both will be adjusted accurately with ZERO (lower one) and SPAN (higher one) potentiometers. Repeat the adjustment until the both ends of the range are accurate. If the output is 0 20 ma, adjust at slightly higher than the zero value, for example at 1 ma ( %). Set SW. switch to ON position only when R8 is installed as required by some special ranges. Note! If a DIP switch has a tape over it, remove it by peeling it off for example with a sharp knife. Do not set the DIP switches through the tape! The DIP switches should be set with an as small and light tool as possible pushing lightly so that the force will not break the switch Table 1. Damping options DAMPING SW.1 SW.2 SW.3 100 µs = 0,1 ms* OFF OFF ON 1 ms OFF OFF OFF 10 ms OFF ON ON 100 ms OFF ON OFF 1 s ON OFF OFF * When using 100 µs damping with mainput other DIPswitch positions are exceptional so if the device will be changed afterwards to 100 µs damping, DIPswitches configuration and adjusting have to be repeated.

Range The table below contains the most common ranges and their configuration. Other, more specific, ranges are possible, and configuring them is advised by support in addition to DIP which is a switch calculator program freely available at www.nokeval.com website with keyword DIP and from Software CD. Table 2. Standard range examples INPUT OUTPUT DAMPING JP1 DIPSWITCHES TO BE SET TO ONPOSITION 0 20 ma 1 ms 12.2 6.1 6. 7.2 100 µs * 12 3.1 3.3.1.3.3 7.2 20 ma 1 ms 12 1.2 1. 2.2 3.2.1.2.3..2 6. 7.2 100 µs * 12 1.2 1.3 3.1 3.2 3.3.1.2.3.3 7.2 0 20 ma 0...10 V 1 ms 12.2 6.1 6. 100 µs * 12 3.1 3.3.1.3.3 0... V 1 ms 12.2 6.1 6. 7.1 100 µs * 12 3.1 3.3.1.3.3 7.1 10...10 V 1 ms 12 1.1 2.1 2.3 3.1 3.2 3.3 3..1.3..2 6.3 6. 100 µs * 12 1.1 1. 3.1 3.3 3..1.3..3 6.2 0...20 ma 1 ms 12 1.1 2.2 3.1 3.2 3..2.3..2 6. 7.2 100 µs * 12 1.1 1.3 3.2 3..2.3 7.2 20 ma 1 ms 12.2 6.1 6. 7.2 100 µs * 12 3.1 3.3.1.3.3 7.2 20 ma 0...10 V 1 ms 12 1.1 2.2 3.1 3.2 3..2.3..2 6. 100 µs * 12 1.1 1.3 3.2 3..2.3 0... V 1 ms 12 1.1 2.2 3.1 3.2 3..2.3..2 6. 7.1 100 µs * 12 1.1 1.3 3.2 3..2.3 7.1 10...10 V 1 ms 12 1.1 2.2 2.3 3.1 3.2 3.3.1.3..2 6.3 6. 100 µs * 12 1.1 1. 3.3.1.3..3 6.2 0 20 ma all 23.2 6.1 7.2 20 ma all 23 1.2 1. 2.2 3.2.1.2.3..2 7.2 0...10 V 0...10 V all 23.2 6.1 0... V all 23.2 6.1 7.1 10...10 V all 23 1.1 2.1 2.3 3.1 3.2 3.3 3..1.3..2 6.3 0 20 ma all 23 3.1 3.2 3.3 3..1.3..2 7.2 20 ma all 23 1.2 1.3 2.1 3.1 3.3.2.3..2 7.2 0... V 0...10 V all 23 3.1 3.2 3.3 3..1.3..2 0... V all 23 3.1 3.2 3.3 3..1.3..2 7.1 10...10 V all 23 1.1 1. 2.2 3.1 3.2 3.3 3..1.2..2 0 20 ma all 23 1.2 2.2 2. 3.1 3.2 3.3.1.2.3..2 6.3 7.2 10...10 V 20 ma all 23 1.2 1.3 2.1 2.2 2.3 2. 3.1 3..1.2.3..2 6.3 7.2 0...10 V all 23 1.2 2.2 2. 3.1 3.2 3.3.1.2.3..2 6.3 0... V all 23 1.2 2.2 2. 3.1 3.2 3.3.1.2.3..2 6.3 7.1 10...10 V all 23.2 6.1 V 0 V all 23 1.2 2.1 2.3.2 6.1 6.3 7.1 1.2 1.2 V 20 ma all 23 1.2 1.3 1. 2.1 3.2 3..3..2 7.2 0 20 ma all 23 3.1 3.2 3.3 3..1.3.2 7.2 20 ma all 23 1.2 1.3 3.1 3.2 3.3 3..1.2.3.2 7.2 0...1 V & Pot. 0...10 V all 23 3.1 3.2 3.3 3..1.3.2 0... V all 23 3.1 3.2 3.3 3..1.3.2 7.1 10...10 V all 23 1.1 1. 3.1 3.2 3.3 3..1.3..2 6.2 10

Table 3. Special range examples with 100 ms damping INPUT OUTPUT JP1 DIPSWITCHES TO BE SET TO ONPOSITION R8 30 30 V 0 10 V OFF 1.2 1.3 1. 2.1 2.2 2.3 2. 3.3 3..1.2.3. (.2). 6.3 2 MΩ 0 20 V 20 ma OFF 1.2 1.3 2.1 2.3 3.1 3..1.2.3. (.2) 6.3. 7.2 1 MΩ 0 30 V 20 ma OFF 1.2 2. 3.1 3.2 3..1.2.3. (.2) 6.3. 7.2 2.2 MΩ Table. Reverse range examples (not applicable with 100 µs damping) INPUT OUTPUT DAMPING JP1 DIPSWITCHES TO BE SET TO ONPOSITION Other 20 ma 20 ma 1 ms 12 1.2 1.3 1. 2.3 2. 3.3.1.2.3..2 6.3 6. 7.2 See ** 0 V 20 ma all 23 1.2 1.3 2.2 2.3 3.1 3.3.2.3..2 6.3 7.2 See ** ** Connect input and wires reversed. Examples of reverse range creation with DIP switch calculator program. Select DIP input Min 20 ma, Max ma and output Min ma, Max 20 ma. Connect input wires and with reversed polarity. DIP input Min V, Max 0 V and output Min ma, Max 20 ma. Connect input wires 3 and with reversed polarity. Troubleshooting Problem: The device front panel has no pin numbers, but the devices ordered earlier had numbers at least for pins closest to the middle part. Solution: This is not a mistake since Oy has left model specific printings away to unify production methods of device models, 620S and 620. If needed official bulletin is available for example for your quality system. When connecting the device the information concerned is available in this user manual and in the label located in the side of the device. Problem: We want to change the device range and trim it, but the device front panel has no S or Z markings. Solution: Look at the solution for the previous problem. Also note that the device case needs to be opened for changing range revealing printed circuit board printings GAIN (Span) and OFFSET (Zero) next to blue potentiometers used for trimming. Problem: We want to change the device range, but some of the DIPswitches are covered with tape. Solution: Component factory s dust cover tapes may be removed by fingernails or carefully peeling with a sharp knife. Problem: We have changed range with the information from DIP switch calculator program, but range changing has not been successful. Solution: DIP can help with the ranges based on inputs and outputs of normal limits (to the maximum of 10 V and 20 ma). Information about ranges requiring component changes such as rare 30/30V 0/10V, can be requested from support. 11

Technical data Width Height Depth Weight 22. mm 82 mm mm 106 g Mounting DIN rail according to DIN 6277 Terminal blocks 2 x 2. mm² Operating temperature 0 C Storage temperature 0 70 C Protection class IP20 Case material plastic Accuracy < 0.0 % of span Repeatability < 0.0 % of span Thermal drift < 0.006 %/ C Input resistance 0 Ω for current input, > 100 MΩ for voltage input Potentiometer 00 Ω 100 kω Output load (ma) max. 600 Ω Power supply 2 VDC ± 10 % Isolation 1000 V inputoutput, functional isolation, not to be connected to mains Range selection DIP switches and jumper Damping T63.3% = 100 µs (0.1 ms), 1 ms, 10 ms, 100 ms or 1 ms Frequency band 0 1600 Hz Power consumption 0 ma voltage output, 60mA maoutput, 80 ma 2wire transmitter input/output 12