Getinge GEB Series Biosafety Sterilizers. Safe, reliable decontamination in biocontainment facilities



Similar documents
GETINGE GEB SERIES BIOSAFETY STERILIZERS SAFE, RELIABLE DECONTAMINATION IN BIOCONTAINMENT FACILITIES. Always with you

BSL3 and BSL4 Autoclaves. Laboratory Line

GE STEAM STERILIZERS FOR PHARMACEUTICAL PRODUCTION

Laboratory & Scientific Line. Bulk Steam Sterilizers. Since

FVA/A1 saturated-steam sterilizer

GETINGE GEW cgmp WASHER/DRYERS SECURING CRITICAL CLEANING IN THE MANUFACTURING ENVIRONMENT

Large Steam Sterilizers for the Life Sciences. Laboratory Line

Laboratory & Scientific Line. Horizontal Steam Sterilizers

Partnership. Large Steam Autoclaves for the Life Sciences. Laboratory Line

Medical Waste Autoclaves. Medical Waste Autoclaves

Partnership. Medical Waste Autoclaves. Medical Waste Autoclaves

German engineering under high pressure

Hospital Sterilizers. T-Max Line

FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

STEAM STERILIZERS. DLOV & DLOM series. more than fifty years of experience in sterilization. DE LAMA s Quality Management System is certified:

Vertical and Benchtop Autoclaves for Life Sciences. Laboratory Line

FACT SHEET : Using Autoclaves Safely

Professional Laboratory Sterilization Safe, Fast and Reliable. Steam sterilizers for research facilities, universities and biocontainment facilities

Fact Sheet on Steam Sterilizers at Stanford University

Animal Laboratory and Vivarium Steam Sterilization Autoclaves

Specifications. Amaro 5000 & Steri 21 MD009/04 EN. A. J. COSTA (IRMÃOS), LDA. Desde 1953 ao Serviço Médico-Hospitalar

STEAM STERILIZERS FOR THE LIFE SCIENCES MADE IN THE USA

Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:

Downstream processing areas of pharmaceutical

STANDARD OPERATING PROCEDURES Safe Autoclave Operations

LifeASSURE PFS. Series Capsules & Cartridges Sterilising Grade PTFE Membrane Filters. 3M Purification. Product brochure

GETINGE GEW 2100LS CAGE AND RACK WASHER PREVENTING CONTAMINATION IN ANIMAL CARE

Infection Control in the Dental Practice through Proper Sterilization

FOF INDUSTRIAL SATURATED STEAM STERILIZERS

RiMatrix S Make easy.

Horizontal Steam Sterilizers. Healthcare Line. Since

Drainage and Grease Management for the Commercial Kitchen

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Biosafety Level 2 (BSL-2) Safety Guidelines

Fundamental Autoclave Techniques

EH&S. Sheet. Fact. Safe and Effective Use of Autoclaves. What are autoclaves? Factors for effective sterilization. Dry heat cycle - when to use

Steripro cgmp. Steam Sterilizers

Vakulab PL. All-rounder for laboratory and research. Long life time and short cycle times. Space saving and ergonomical

Decontamination and Waste Management

Professional Certification in Biological Waste Management Examination Content, Sample Questions & References

Steam Sterilization Cycles for Lab Applications

OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE

Revised EHS Biosafety. 1 Select appropriate containers/bags for autoclaving.

Questionnaire Pure Media Systems

Element D Services Plumbing

Touchclave-Lab... the revolutionary new range of square-section laboratory sterilizers from LTE Scientific

PBX Series Quick Fit Connector Bimetallic Steam Traps

GetinGe 88-SerieS WaSher DiSinfectorS

Element D Services Plumbing

WIBObarrier OCS - Open Containment Systems WIBObarrier CCS - Closed Containment Systems

STEAM STERILIZERS FOR THE LIFE SCIENCES

Laboratory- and sterilisation equipment HMC EUROPE

The University of Texas at San Antonio Office of Environmental Health, Safety and Risk Management. Part A. Biological Waste Management Safety Plan

OT 40L / 90L. Laboratory Steam Sterilizers

Cooking at the Speed of light!

Procedures for the Effective Use of Biological Safety Cabinets

LTE Scientific Ltd. Touchclave-Lab... the revolutionary range of square-section laboratory sterilizers from LTE Scientific

A Guide to the Handling and Disposal of Medical Waste Contents

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Guidance on safe use of Autoclaves

Nirvana. Cycling Refrigerated Dryers

Clinic Washer-Disinfectors. Washer-Disinfector Line

Power consumption (kw)

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

HA HE Series. Solutions for Your needs. fl exible and confi gure-to-order coils. Healthy Solutions coils

AUTOCLAVE PROGRAM. SOP Bio-006 FOR THE USE OF AUTOCLAVE FOR STERILIZATION OF MATERIALS AND BIOLOGICAL WASTE SOP

WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL

LyoBeta. R+D Freeze-Dryers

EcoStar Professional warewashing with integrated effi ciency and hygienic reliability

EcoCWave. The all-round talent for aqueous part cleaning.

Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications

KGI MEDICAL WASTE MANAGEMENT PLAN

Security rooms for data centres

UNIVERSITY OF RICHMOND REGULATED MEDICAL WASTE MANAGEMENT GUIDELINES

Biosafety Level 2 Criteria

Administrative Procedure

Freezers - Ultrafreezers. Platilab & Irilab Series

Biohazardous Waste Management Plan

GETINGE CLEAN MANAGEMENT SYSTEM

UCCS Biosafety Management Policy

Adsorption air dryers ADS 1 215

Sterilizers with extra class

Vacuum drying oven for non-flammable solvents

Sterilization methods and equipment Lab 1-2

PI s Name Date Bldg./Rm# CDC Biosafety Level 3 (BSL-3)

Monitoring the autoclaving process in the pharmaceutical industry

CHAPTER V: DISPOSAL OF WASTES CONTAMINATED WITH INFECTIOUS AGENTS

Compressor Service & Maintenance Manual

Material test chamber with mechanical convection

Plant components, selected for sound performance

Risk Assessment: Biosafety Cabinet

ElastoFlake & ElastoTec

Atlas Copco. On-site Industrial Gases Nitrogen & Oxygen Generators

Systec Laboratory Autoclaves Systec H-Series. Horizontal floor-standing autoclaves. Systec H-Series 2D. Pass-through autoclaves.

Air Shower Biosafety Changing Station with Pass-Through Box Pass-Through Box Automatic atomizer for no-contact hand disinfection

UV Disinfection Systems A Series. Main Applications: Drinking Water, Process Water, Warm Water / Legionellae. IT T Industries Engineered for life

AGENDA. Technical Biosafety Concepts in Laboratories and Animal Facilities. 1. Comprehension of BioSafety and BioSecurity

Company background and. portfolio overview

Transcription:

Getinge GEB Series Biosafety Sterilizers Safe, reliable decontamination in biocontainment facilities

A new sense of reality In light of the biohazards we live with today, and may be faced with in the future, the bio-containment community is responding with a new sense of urgency to prepare for these emerging threats. Biocontainment laboratory facilities once considered state of the art are being reconfi gured and upgraded to refl ect the new reality of bio-terrorism. Until now, there has been an absence of accepted standards governing sterilizers used in a bio-containment environment, despite the need for them. That s why Getinge is collaborating with laboratory designers, architects and bio-containment specialists to determine industry wide guidelines for sterilizer design and installation. Getinge is dedicated to providing bio-containment sterilizer systems that minimize risk associated with existing bio-safety facilities, while establishing a new benchmark of sterilization and containment for laboratories that have yet to be built. Why Getinge? Getinge is a leading global medical technology group that provides complete infection control solutions to hospitals, laboratories and pharmaceutical companies around the world. The Getinge Group is the world market leader in this fi eld, with sales and service support channels in more than 100 countries on all 5 continents. Extensive knowledge of processes and applications, built up over the last 70 years, have made Getinge the world leader in the fi eld of decontamination and sterilization. This knowledge is made available to our customers in the form of features built into a comprehensive range of equipment. We also share our expertise with architects, engineers, microbiologists, laboratory personnel and equipment operators to enable them to optimize the use of Getinge systems for maximum safety and effi ciency. 2

A dedicated yet versatile range Like all laboratories and research facilities, bio-containment suites need autoclaves for sterilization of media and equipment and decontamination of waste material. The pathogenic nature of the waste material from such facilities coupled with the use of the autoclave as a barrier between the facility and the outside world places special requirements on the autoclave design and processes used: standard autoclaves cannot fulfi ll these criteria. The Getinge GEB Series is a standardised range of dedicated autoclaves, specifi cally designed for use in BSL 3 and 4 facilities. A wide variety of chamber sizes are available, ranging from 0.3 to 17 cu.m and all models are available with one or two doors as appropriate for use in the facility. The GEB range is available with a range of fl exible process combinations to suit the type of facility, for example: Microbiology laboratory (incl. Biosafety facilities) Glassware, culture media, hazardous waste Animal care facility / vivarium Cages, racks, bedding, pathogenic waste Please refer to individual product specifi cations for additional details. Unique features of the GEB range include: Validated biological sealing fl ange (bioseal). Creates a hermetic seal between hot and cold zones. Third party certifi ed design. Hermetically sealed conduits (condulets) through the bioseal for all electrical cabling into the hot zone. Membrane fi ltration on all pneumatic signal lines passing through the bioseal. Isolating valves and chemical decontaminant injection ports in the process system - for decontamination of piping system prior to maintenance activities. Getinge s unique effl uent sterilization process. Safe and effective air removal for sterilization effi cacy and condensate retention and sterilization. SMALL GEB STEAM STERILIZERS 600 Series. Fully automatic high-pressure steam sterilizers with a single vertical sliding door, or two vertical sliding doors for pass-through operation. Standard chamber volume: 10 to 26ft 3 (0.3 to 0.8 m 3 ) MEDIUM-SIZE GEB STEAM STERILIZERS 900 Series. Similar to the small sterilizers but with larger chamber sizes and automatic horizontal sliding door(s). Standard chamber volume: 21 to 36ft 3 (0.6 to 1.1 m 3 ) LARGE / BULK GEB STEAM STERILIZERS 1400 and 2200 Series. Sterilizers with automatic horizontal sliding door(s) for large-scale applications. They can be pit-mounted for convenient fl oor loading. Standard chamber volume: 47 to 590ft 3 (1.4 to 17 m 3 ) 3

Features that set the industry standards The GEB Series sterilizers set the industry standard for a new generation of autoclaves designed specifi cally in response to the need for new, modern biocontainment facilities; to defi ne a new state-of-the-art. DOOR SEALING MECHANISM Choose from Getinge s traditional active door gasket or the revolutionary Slideloc passive system. The active gasket is mechanically simple and inherently reliable while Getinge s Slideloc System* does not rely on utilities to maintain the seal between chamber and door. DIAPHRAGM ISOLATED INSTRUMENTATION Pressure transducers and gauges are isolated from the chamber by sanitary diaphragms. This eliminates capillary piping which accumulates stagnant water in the process system (where microorganisms may multiply). The safety valve is similarly isolated by rupture disk BIOSEAL CONNECTIONS Sealed conduits are provided through the bioseal for electrical connections (with 100% redundancy).* All pneumatic lines are provided with membrane fi lters. SPECIALISED WASTE PROCESSING Processes are purpose designed for effective decontamination, including treatment of plastic waste material in disposal bags and part sealed containers. This specialised process prevents fusion of the plastic materials and entrapment of air which would otherwise prevent steam penetration. BIOLOGICAL SEALING FLANGE (BIOSEAL) Typically a double door chamber forms a barrier between the hot and cold zones. As such the chamber must be hermetically sealed to the wall. Traditional fl anges cannot guarantee an airtight seal due to thermal stresses and incompatible materials. Getinge s Biolseal combines bolted stainless steel panels, a rubber gasket* and a wall fl ange that is installed in the building fabric. The design is independently validated and certifi ed. ISOLATING VALVES & INJECTION PORTS The process and drain piping system is provided with isolating valves and chemical (typ. formaldehyde) injection ports to allow safe maintenance and fi lter changing. NOTE: The GEB Series is based on Getinge s GE Series. Most features, options and process combinations of the GE Series are also available for the GEB Series. See GE Series brochure and product specifi cations for details. GEB Series - typical models ** 6610 6910 91415 102222 182222 CHAMBER VOLUME ft³/m³ 16 / 0.45 29 / 0.83 71 / 2.01 170 / 4.8 308 / 8.70 CHAMBER WIDTH, in/mm 26 / 672 26 / 672 35 / 900 39 / 1000 71 / 1800 CHAMBER HEIGHT, in/mm 26 / 672 36 / 920 57 / 1450 86 / 2200 86 / 2200 CHAMBER DEPTH, in/mm 39 / 1000 53 / 1350 60 / 1540 86 / 2200 86 / 2200 * See over page ** Typical only. Many models available in each series. 4

Sterilization effi cacy versus containment Containment presents several challenges to the sterilization system designer: An established principle of steam sterilization demands air removal prior to steam injection. Challenge: air in contact with materials in the chamber is contaminated and cannot be removed without treatment. A physical principle is that steam condenses when it comes in contact with cooler surfaces. Challenge: the condensate produced as steam heats the contaminated materials, prior to achieving sterilization conditions, is itself contaminated. It requires treatment prior to release to the building drain. Several options are available to treat the removed air and condensate, and should be applied based on a risk assessment of the facility design. The options are summarised below. OPTION 1 Use a standard autoclave process, direct all effl uent to drain (with use of kill tank for BSL4 applications). This approach has been used historically, but is not recommended for modern facilities. Systems using an ejector for air removal rather than a mechanical pump should be avoided as the process is ineffi cient. OPTION 2 Filter the air evacuated from the chamber through a 0.22µm sterile membrane fi lter. This renders the air sterile and the fi lter is steam sterilized during the subsequent process. For added security, a second fi lter may be installed in series. Additionally, an automatic in-place WIT integrity test may be performed on the fi ltration system. Condensate produced is collected in the chamber base and is heated by incoming steam and by the steam heated external jacket. Sterilization of the condensate is confi rmed by temperature sensors. Optional dual sterile membrane fi lters arranged in series with optional in-place automatic WIT integrity testing. OPTION 3 Pass the air through the unique Getinge incineration system. This validated ultra high temperature device provides a torturous pathway for the evacuated air. This destroys all viable organisms, rendering the exhaust air sterile and safe to discharge. Condensate is treated as described for Option 2. Optional unique in-line incinerator deactivates bacteria and spores as they are evacuated from the chamber. 5

1 2 SAFEGUARDING YOUR INVESTMENT CORE FEATURES OF THE GEB SERIES 3 4 1. The unique sectional jacket adds strength and rigidity to the chamber, and robotic welding eliminates defects. The resulting construction ensures a long product lifecycle to safeguard your facility and investment 2. The independently validated Bioseal fl ange creates a hermetic seal between zones. Fabricated from a combination of bolted steel panels and a rubber gasket. The mating wall fl ange is provided to the client during construction for installation in the building fabric. 3. Electrical signals to the hot zone pass through sealed conduits (condulets). Similarly pneumatic signals pass through membrane fi lters. 4. The doors of Getinge sterilizers are the cleanest, safest and simplest on the market. 5. Getinge s unique Slideloc passive door locking system. Provides a compression seal of the door gasket when the door is in the closed position. Does not rely on services to maintain the seal. 6. Top-quality piping and components are assembled to the highest standards. 5 6

Control systems As standard, the GEB Series utilizes Getinge s renowned PACS 3000 Control System. This dedicated controller is used on thousands of sterilization and washing systems worldwide and is purpose designed for the application. PACS 3000 accurately handles tasks such as parameter setting, control operations, system programming and data processing, presentation and storage. Versatile features The major features included in PACS 3000 are: A user-friendly interface Extensive documentation Remaining cycle-time indicator Automatic sensor calibration Comprehensive alarms/alerts Process and alarm logging Multilevel password protection Multilanguage display PACS Supervisor independent monitoring option Standard PLC Systems The PACS 3000 is specifi cally designed to control process equipment for applications in the Life Sciences. Many thousands of PACS systems are in operation around the world. However, if a customer prefers, standard PLC systems are available based on Allen-Bradley platforms. These PLCs are provided as standard options with similar functionality and documentation to the Getinge PACS 3000. OP30 USER INTERFACE Door open/close buttons. Status LEDs. 5.7 color screen for process info: Remaining time, cycle & phase, temperature(s) PROCESS DOCUMENTATION Graphical process presentation: Plot graph, bar graph Parameter settings. Maintenance & service menus. System confi guration. NETWORK SOLUTIONS Ethernet Industry standard protocols Remote support facility CS 1000 Other equipment and services from Getinge In addition to the GEB Series, Getinge supplies a wide range of other equipment for a wide range applications in Research or Microbiology laboratories. Whatever the application in the Life Sciences, Getinge has the solution for all your washing and sterilization applications. Consult Getinge for further information. www.getinge.com / info@getinge.com Getinge GEW Series Washer-Disinfectors are ideal for larger items such as animal cages and racks. Typical small Getinge laboratory glassware Washer / Dryer. 7

SERVICE PRODUCTS TR AINING KNOW-HOW DOCU MENTATION GETINGE provides a unique range of products that fi t together with coherent design and functionality. We also offer expert advice, analysis of requirements, interior design support, system installation, after-sales service and training. Getinge USA Inc. 1777 East Henrietta Road, Rochester, New York 14623-3133 USA Phone: +1 800 475 9040 Fax: +1 585 272 5033 E-mail: info@getingeusa.com www.getingeproducts.com