QuickSpecs. HP Smart Array 5312 Controller. Overview



Similar documents
Models Smart Array 6402A/128 Controller 3X-KZPEC-BF Smart Array 6404A/256 two 2 channel Controllers

HP Smart Array 5i Plus Controller and Battery Backed Write Cache (BBWC) Enabler

QuickSpecs. Models HP Smart Array E200 Controller. Upgrade Options Cache Upgrade. Overview

QuickSpecs. What's New Boot from Tape. Models HP Smart Array P411 Controller

How To Use An Hp Smart Array P212 (Sas) With A 1-Year Warranty On A 2 Terabyte Hard Drive (Sata) And A 1 Terabyte (Sasa) Hard Drive With A 2-Year License (S

QuickSpecs. What's New. At A Glance. Models. HP StorageWorks SB40c storage blade. Overview

QuickSpecs. Models. HP Dynamic Smart Array B320i Controller. Overview

QuickSpecs. What's New Support for HP MSA 2040 Storage. Models. HP Smart Array P712m Controller. Overview

QuickSpecs. Models. Overview

Assessing RAID ADG vs. RAID 5 vs. RAID 1+0

QuickSpecs. HP StorageWorks Modular Smart Array 500 G2. Overview

QuickSpecs. Models. HP Smart Array P731m Controller. Overview

QuickSpecs. Models. Overview

QuickSpecs. What's New. HP Smart Array P410 Controller Overview

QuickSpecs. Models. HP Smart Array P721m Controller. Overview

QuickSpecs. What's New. HP Smart Array P411 Controller. Overview

HP 4 Gb PCI-X 2.0 Host Bus Adapters Overview

QuickSpecs. What's New. HP Smart Array P410 Controller. Overview

QuickSpecs. HP Dynamic Smart Array Controllers. Models HP Dynamic Smart Array RAID Controllers. HP Dynamic Smart Array Controllers.

QuickSpecs. Models. HP StorageWorks Modular Smart Array 50 Enclosure. HP StorageWorks Modular Smart Array 50 Enclosure. Overview

New Advanced RAID Level for Today's Larger Storage Capacities: Advanced Data Guarding

QuickSpecs. What's New HP 750GB 1.5G SATA 7.2K 3.5" Hard Disk Drive. HP Serial-ATA (SATA) Hard Drive Option Kits. Overview

QuickSpecs. Models HP ProLiant Storage Server iscsi Feature Pack. Overview

HP StorageWorks 20 Modular Smart Array Overview

QuickSpecs. What's New HP 3TB 6G SAS 7.2K 3.5-inch Midline Hard Drive. HP SAS Enterprise and SAS Midline Hard Drives. Overview

RAID 5 rebuild performance in ProLiant

QuickSpecs. What's New New GB Pluggable Ultra320 SCSI 15,000 rpm Universal Hard Drive (1") HP SCSI Ultra320 Hard Drive Option Kits (Servers)

QuickSpecs. HP SATA Hard Drives. Overview

QuickSpecs. What's New HP 1.2TB 6G SAS 10K rpm SFF (2.5-inch) SC Enterprise 3yr Warranty Hard Drive

QuickSpecs. HP Serial-ATA (SATA) Entry (ETY) and Midline (MDL) Hard Drive Option Kits. Overview

QuickSpecs. HP StorageWorks 60 Modular Smart Array. Overview

QuickSpecs. HP SATA Hard Drives. Overview

QuickSpecs. What's New Dual Port SFF 10K and 15K SAS drives Dual Port 3.5" 15K SAS drives. HP SAS Drives (Servers) Overview

QuickSpecs. What's New. HP StorageWorks SB40c Storage Blade Overview

QuickSpecs. What's New. Models. Overview

HP ProLiant DL100 G2 Data Protection Storage Server. HP ProLiant DL100 G2 Data Protection Storage Server

QuickSpecs. Models. HP StorageWorks 8Gb PCIe FC HBAs Overview. Part Number AK344A

HP StorageWorks P2000 G3 and MSA2000 G2 Arrays

QuickSpecs. HP SATA Hard Drives. Overview

QuickSpecs. HP SAS Enterprise and SAS Midline Hard Drives Overview

HP StorageWorks Enterprise Backup Solution and Direct Attach Solutions

RAID Technology Overview

HP 8Gb PCIe FC HBAs Overview

QuickSpecs. Compaq StorageWorks & SANworks for Datacenter M ODELS P RODUCT DESCRIPTION / OVERVIEW C USTOMER BENEFITS

TECHNOLOGY BRIEF. Compaq RAID on a Chip Technology EXECUTIVE SUMMARY CONTENTS

QuickSpecs. HP D2220sb Storage Blade. Overview. Do you need a direct attached or shared storage solution within your BladeSystem enclosure?

HP Solid State Drive (SSD) Overview

Increasing Server Storage and Capacity: Upgrading the SMART-2DH Controller to the Smart Array 4200 Controller

HP ProLiant Essentials Performance Management Pack 3.0 Support Matrix

HP and Mimosa Systems A system for archiving, recovery, and storage optimization white paper

HP D2200sb Storage Blade Overview. Do you need a direct attached or shared storage solution within your BladeSystem enclosure?

HP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN

QuickSpecs. HP IP Console Switch with Virtual Media Overview

HP Server Console Switch with Virtual Media Overview

Windows Server 2008 R2 for Itanium-Based Systems offers the following high-end features and capabilities:

HP reference configuration for entry-level SAS Grid Manager solutions

IBM ^ xseries ServeRAID Technology

How to register. Who should attend Services, both internal HP and external

RAID 6 with HP Advanced Data Guarding technology:

HP ProLiant Storage Server family. Radically simple storage

Use cases and best practices for HP StorageWorks P2000 G3 MSA FC/iSCSI Combo Controller

IBM TotalStorage Network Attached Storage 300G

Education. Servicing the IBM ServeRAID-8k Serial- Attached SCSI Controller. Study guide. XW5078 Release 1.00

QuickSpecs. HP StorageWorks Direct Backup Engine for Tape Libraries. Extended Tape Library Architecture (ETLA) Family. Models.

EMC Backup and Recovery for Microsoft SQL Server 2008 Enabled by EMC Celerra Unified Storage

The Advantages of Multi-Port Network Adapters in an SWsoft Virtual Environment

Models 300GB SAS 15K rpm 6Gb/s 3.5" HDD HP 900GB SAS 10K SFF HDD HP 1.2TB SAS 10K SFF HDD

QuickSpecs. What's New. Models. ProLiant Essentials Server Migration Pack - Physical to ProLiant Edition. Overview

HP Smart Array Controller technology

HP SATA DVD RW Optical Drives Overview. HP 9.5mm SATA DVD RW Optical Drive

VTrak SATA RAID Storage System

Red Hat Enterprise Linux and management bundle for HP BladeSystem TM

TotalStorage Network Attached Storage 300G Cost effective integration of NAS and LAN solutions

QuickSpecs. Models HP Server Console Switches

Hot-Plug Disk Drive Removal and Replacement Guidelines for Compaq Smart Array Controllers

It is also available as part of the HP IS DVD and the Management DVD/HPSIM install.

SAP database backup and restore solutions for HP StorageWorks Enterprise Virtual Array using HP Data Protector 6.1 software

What is RAID--BASICS? Mylex RAID Primer. A simple guide to understanding RAID

Network Attached Storage 300

HP Smart Array Controllers and basic RAID performance factors

Includes a single server edition of HP StorageWorks Data Protector Express for Windows/Linux/NetWare.

QuickSpecs. 3U Rack-Mount Kit. HP StorageWorks Rack-Mount Tape Drive Kits Overview

Redundancy in enterprise storage networks using dual-domain SAS configurations

QuickSpecs. What's New. HP RDX Removable Disk Cartridges. Overview

HP Array Technologies

HP Smart Array Controller technology

RAID-01 (ciss) B mass storage driver release notes, edition 2

HP A7143A RAID160 SA Controller Support Guide

Transcription:

Overview Models 238633-B21 238633-291 (Japan) Feature List: High Performance PCI-X Architecture High Capacity Two Ultra 3 SCSI channels support up to 28 drives Modular battery-backed cache design 128 MB battery-backed write cache 256 MB cache upgrade available Introduction The Smart Array 5312 (SA-5312) high-performance, dual channel Ultra3, PCI-X array controller provides reliable data protection for ProLiant servers and offers flexibility thanks to an innovative modular design. The SA-5312 controller raises the standard to higher performance levels with several enhancements including enhanced memory architecture and RAID engine. Designed and tested with industry-standard ProLiant Servers for greater reliability, this controller is ideal for the distributed workgroup server or centralized departmental server, and like other Smart Array controllers, the SA-5312 offers complete data compatibility with previous generations' Smart Array controllers for easy data migration and upgradability. What's New Updated option support list, maximum storage support. Key Features Modular, easy-to-upgrade design lets you optimize performance as needed, from 128-MB to 256-MB battery-backed cache. High-performance, Fifth generation architecture offers the new hardware RAID engine, and a new performance memory architecture for increased performance over previous generation controllers. Recovery ROM protects against a ROM failure or corruption. Ultra3 SCSI technology delivers high performance and data bandwidth up to 160 MB/s bandwidth per channel. Dual Channels provide the ability to support up to 28 drives or 4.1TB (28 x 146.8 GB Ultra320 1" Hard Drives). Mix-and-match LVD SCSI compatibility protects your investments and lets you deploy drives as needed. Battery-backed Cache protects cached data in the event of a power outage, server failure or controller failure, and redundant, replaceable batteries take that protection even further. 64-bit, 133 MHz PCI-X interface boosts bandwidth above 1GB/s burst transfer rate over PCI-X bus. 64-bit memory addressing supports servers with greater than 4 GB of memory. Online Management Features: Online Capacity Expansion, Online RAID Level Migration, Online Stripe Size Migration, Online Spares (Global), User Selectable Read/Write cache, User Selectable Expand and Rebuild Priority The Smart Array Advantage HP's innovative design and integration work of the Smart Array family of products creates customer value that is unmatched in the industry. Use of Smart Array products across multiple applications results in a much lower Total Cost of Ownership (TCO) than any other server storage RAID products. The HP Smart Array family brings an unparalleled return on investment through: Data Compatibility among all models of Smart Array controllers allows simple and easy upgrades any time needs for higher performance, capacity, and availability increase. Even successive generations of Smart Array controllers understand the data format of other Smart Array Controllers. Consistent Configuration and Management Tools. All Smart Array products utilize a standard set of management and utility software. These tools minimize Total Cost of Ownership (TCO) by reducing training requirements and technical expertise necessary to install and maintain the ProLiant server storage. Universal Hard Drive form factor is for use across multiple ProLiant servers, disk enclosures and storage systems. With compatibility across many enterprise platforms, you are free to deploy and re-deploy these drives to quickly deliver increased storage capacity, migrate data between systems, and easily manage spare drives. Pre-Failure Warranty means Insight Manager not only reports when a drive is going to fail but allows replacement of failing drives prior to actual failure. For complete details, consult the HP Support Center or refer to your ProLiant Server documentation. DA - 11328 Worldwide Version 5 August 27, 2003 Page 1

Overview Software Suite All Smart Array products share a common set of configuration, management and diagnostic tools, including Array Configuration Utility (ACU-XE), Array Diagnostic Utility (ADU), and Insight Manager. This software consistency of tools reduces the cost of training for each successive generation of product and takes much of the guesswork out of troubleshooting field problems. These tools lower the total cost of ownership by reducing training and technical expertise necessary to install and maintain the HP server storage. Insight Manager Powerful server and server options/storage manager tool Monitors over 1200 server parameters Configuration/Diagnostic Utilities Array Configuration Utility (ACU-XE) Powerful configuration utility for all Smart Array controllers Provides a graphical view of HP drive array configurations Easy to use Wizards for configuration Array Diagnostic Utility (ADU) Powerful diagnostic utility for all Smart Array controllers Options ROM Configuration Capability Rapid configuration upon initial install of the OS DA - 11328 Worldwide Version 5 August 27, 2003 Page 2

Compatibility Servers For up to date compatibility, please see the following URL for complete Smart Array 5312 compatibility and support information. http://www.hp.com/products/smartarray NOTE: The SA-5312 is not supported in 5 volt PCI slots Operating Systems Microsoft Windows NT 4.0, 2000 ** Novell NetWare 4.2, 5.x ** Linux DA - 11328 Worldwide Version 5 August 27, 2003 Page 3

Product Highlights Data Compatibility Data compatibility among all models of Smart Array Controllers means customers can instantly upgrade their Smart Array products to get to higher performance, capacity and availability. Unlike competitive products, successive generations of Smart Array products understand the data format of other Smart Array controllers, providing investment protection for your HP storage solution. Affordable HP's new high-performance architecture sets new boundaries of industry performance expectations! Wide Ultra3 SCSI (160 MB/s bandwidth) per channel High-performance 64-bit architecture New performance memory architecture providing tri-directional data flow for improved performance 64-bit, 133-MHz PCI-X bus (1-GB/s bandwidth) Capacity Given the need rapid capacity expansion, the SA-5312: Two Ultra3 SCSI channels support up to 28 disk drives Up to 4.1TB of storage per PCI slot Availability Provides increased server uptime by providing advanced storage functionality: Online RAID Level Migration (between any RAID level) Online Capacity Expansion Logical Drive Capacity Extension Global Online Spare Pre-Failure Warranty Fault Prevention The following features offer detection of possible failures before they occur, allowing preventive action to be taken: S.M.A.R.T.: Self Monitoring Analysis and Reporting Technology first developed at HP detects possible hard disk failure before it occurs, allowing replacement of the component before failure occurs. Drive Parameter Tracking monitors drive operational parameters, predicting failure and notifying the administrator. Dynamic Sector Repairing continually performs background surface scans on the hard disk drives during inactive periods and automatically re-maps bad sectors, ensuring data integrity. Smart Array Cache Tracking monitors integrity of controller cache, allowing pre-failure preventative maintenance. Environment Tracking for External Storage System monitors Fault Tolerance Keeps data available and server running while a failed drive is being replaced; several fault tolerance configurations are supported including: Distributed Data Guarding (RAID 5): This allocates parity data across multiple drives and allows simultaneous write operations. It is recommended for up to 14 Hard drives. Drive Mirroring (RAID 1, 1+0): It allocates half of the drive array to data and the other half to mirrored data, providing two copies of every file. It is a fast performance RAID. Fault Recovery Minimizes downtime, reconstructs data, and facilitates a quick recovery from drive failure Recovery ROM: Provides a unique redundancy feature that protects from a ROM failure. A new version of firmware can be flashed to the ROM while the controller maintains the last know working version of firmware. If the firmware becomes corrupt, the controller will revert back to the previous version of firmware and continue operating. This reduces the risk of flashing firmware to the controller. On-Line Spares: Up to two spare drives can be installed prior to drive failure. If a failure occurs, recovery begins with an On-Line Spare and data is reconstructed automatically. ECC-Protected Cache Memory: Removable, battery-backed cache memory protects data, up to four days, in the event of power failure, server hardware failure or controller failure. In addition, HP provides an exclusive design that includes redundant and replaceable batteries for greater cache protection. Ease of Use Consistency and Upgradability make the Smart Array family unique in the industry: GUI based configuration, management and diagnostic software tools Common data formatting between generations of products Data migration between servers and external storage enclosures DA - 11328 Worldwide Version 5 August 27, 2003 Page 4

Service and Support, HP Care Pack and Warranty Information Software Product Services Standalone telephone support Rights to new license version Media and documentation updates Hardware Product Services Installation services On-site maintenance (includes warranty support) Response time upgrades during the warranty period Post-warranty coverage RAID setup and performance consulting via statement of work For additional hardware installation and maintenance information, please refer to the URL listed below: http://www.hp.com/hps/hardware/ Warranty Upgrade Options Response - Upgrade on-site response from next business day to same day 4 hours Coverage - Extend hours of coverage from 9 hours x 5 days to 24 hours x 7 days Duration - Select duration of coverage for a period of 1, 3, or 5 years HP Care Pack Information HP Care Pack is defined as an upgrade to the product warranty attribute, available for a specific duration and hours of coverage. HP Care Pack is not available for less than the product's warranty duration. HP Care Pack is available for sale anytime during the warranty period for most products, but the commencement date will be the same as the Warranty Start Date (delivery date to end user customer). Proof of purchase may be required. HP Care Pack services are prepaid. For additional HP Care Pack (hardware & software) information, as well as orderable part numbers, please refer to the URL http://www.hp.com/hps/carepack/ Components The following brick level options/components do not have individual HP Care Pack Services. These items will be included in product HP Care Pack Services into which they are installed. Disk Drives Tape Drives CD/DVD ROM SCSI Hubs in SBBs Adapters Bus Converters Backplane RAID Controllers Power Supplies Cabling Fans DA - 11328 Worldwide Version 5 August 27, 2003 Page 5

Options Controller Upgrade Options 256 MB Battery-Backed Cache Module NOTE: This 256 MB Battery-Backed Cache Module supports the Smart Array 5300 series controllers, MSA 1000 and the Smart Array Cluster Storage 254786-B21 Software StorageWorks Virtual Replicator by HP License & Media (CD-ROM) 388931-B21 License Only 388932-B21 Disk Drive Enclosures StorageWorks Enclosure 4314T 190210-001 StorageWorks Enclosure 4314T (Int'l) 190210-B31 StorageWorks Enclosure 4314T (Japan) 190210-291 StorageWorks Enclosure 4314R 190209-001 StorageWorks Enclosure 4314R (Int'l) 190209-B31 StorageWorks Enclosure 4314R (Japan) 190209-291 StorageWorks Enclosure 4354R 190211-001 StorageWorks Enclosure 4354R (Int'l) 190211-B31 StorageWorks Enclosure 4354R (Japan) 190211-291 Hard Drives Wide Ultra3 SCSI Universal Drives Hot Plug 36.4-GB Wide Ultra3 SCSI 15,000 rpm Drive (1") 232916-B22 18.2-GB Wide Ultra3 SCSI 15,000 rpm Drive (1") 188122-B21 9.1-GB Wide Ultra3 SCSI 15,000 rpm Drive (1") 188120-B21 72.8-GB Wide Ultra3 SCSI 10,000 rpm Drive (1") 232432-B22 36.4-GB Wide Ultra3 SCSI 10,000 rpm Drive (1") 176496-B22 18.2-GB Wide Ultra3 SCSI 10,000 rpm Drive (1") 142673-B22 9.1-GB Wide Ultra3 SCSI 10,000 rpm Drive (1") 142671-B22 36-GB Wide Ultra3 SCSI 10,000 rpm Drives (1"), 10 pack 232617-B21 18-GB Wide Ultra3 SCSI 10,000 rpm Drives (1"), 10 pack 202352-B21 Ultra320 Universal Drives Hot Plug 36.4GB 10,000 rpm, U320 Universal Hard Drive, 1" 286713-B22 72.8GB 10,000 rpm, U320 Universal Hard Drive, 1" 286714-B22 146.8GB 10,000 rpm, U320 Universal Hard Drive, 1" 286716-B22 18.2GB 15,000 rpm, U320 Universal Hard Drive, 1" 286775-B22 36.4GB 15,000 rpm, U320 Universal Hard Drive, 1" 286776-B22 72.8GB 15,000 rpm, U320 Universal Hard Drive, 1" 286778-B22 NOTE: This is a list of supported hard disk drives (note that some drives may be discontinued). NOTE: For complete compatibility information, refer to the SCSI Hard Drive Compatibility table located at: http://www.compaq.com/products/servers/proliantstorage/drivesenclosures/docs/index.html Universal Hot Plug Tape Drives AIT 100 GB, Hot Plug (Carbon) 249161-B21 AIT 50 GB, Hot Plug (Carbon) 215487-B21 AIT 35 GB, LVD Hot Plug (Carbon) 216886-B21 20/40-GB DAT, Hot Plug (Carbon) 215488-B21 DA - 11328 Worldwide Version 5 August 27, 2003 Page 6

Technical Specifications Electrical Interface LVD (Low Voltage Differential) Protocol Support Wide Ultra3 SCSI (160 MB/s per channel) SCSI Ports 2 external/2 internal shared Drives Supported Up to 28 drives Maximum Capacity 4.1 TB (28 drives x 146.8 GB Ultra320) PCI PCI-X and 3.3 volt PCI compatibility only NOTE: The SA-5312 is not supported in 5 volt PCI slots. PCI Bus Speed 64-bit, 133-MHz PCI-X (1 GB/s maximum bandwidth) Logical Drives Up to 32 logical drives RAID Support RAID 5 (Distributed Data Guarding) RAID 1+ 0 (Striping & Mirroring) RAID 0 (Striping) Cache Memory 128 MB Read/Write (256-MB module upgrade available) ECC protection, battery-backed, and removable Cache Batteries Up to 4 days of redundant battery life (72hrs. for the 256-MB module) removable for easy replacement Upgradable Firmware 2-MB flashable ROM Disk Drive and Enclosure Ultra3 & Ultra2 Protocol Support Memory Addressing 64-bit, supporting servers memory greater than 4 GB Dimensions (HxWxD) 18.375 x 8.25 x 4 in/46.67 x 20.95 x 10.16 cm Weight Smart Array 5312 3.26 lb/1.48 kg Family Information Smart Array 5312 Smart Array 5300 Stripe Set Migration Yes Yes RAID Level Migration Yes Yes Redundant Controllers No No Online Spare Support Yes Yes Capacity Extension Yes Yes SAN Access Module No Yes PCI Bus 64-bit, 133-MHz PCI-X 64-bit, 66-MHz Copyright 2003 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows are registered trademarks or trademarks of Microsoft Corporation in the U.S. and/or other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. DA - 11328 Worldwide Version 5 August 27, 2003 Page 7