e 2 ALPHA Medium Voltage Switchgear Data Sheet K-1.1.2 EN



Similar documents
NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

MNS is Switchgear System Technical Overview

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Secondary Unit Substations

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

Unified requirements for systems with voltages above 1 kv up to 15 kv

The Intelligent AX1 Switchgear for Medium Voltage

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

MEDIUM VOLTAGE SWITCHGEAR AND CONTROLGEAR MODEL MS-E. IEC /12 /15 kv 25, 31.5, 40 ka

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

The power distribution board that sets new standards

HMS Air-Insulated Medium-Voltage Metal-Clad Switchgear. Internal Arc Proof

SIVACON The Versatile Low-Voltage Switchboard

MEDIUM VOLTAGE SWITCHGEAR CATALOGUE. Code: P2490_xx

MEDIUM VOLTAGE SWITCHGEAR. DI-2, a modular concept combining all mediumvoltage

Switchboard system. NorLine 800

TriLine ASSEMBLY System PowerModules

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

7.2KV SL400 Withdrawable Vacuum Contactor-Fuse Combination Units

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

Metal Enclosed Switchgears Metal Clad Switchgears Gas Insulated RMU's

Safe and secure distribution of medium voltage with AX1

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

P System Cubicles. Certified for more safety

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

Session Eleven: Development of Standards for MV Switchgear Rated for Arc Protection

DF-DT (G) MEDIUM VOLTAGE SWITCHGEAR THE MODULAR CONCEPT. User Manual. SGC - SwitchGear Company nv - Moorstraat 24 - B-9850 Nevele - Belgium

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

Installation, Operation and Maintenance Instructions. Uniflex ABB PTMV

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Engineering Specification

Low Voltage Switchboards The Best Technical Solution for Your Ship

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

Advantages of Fixed Circuit Breaker Switchgear

SIVACON Low Voltage Switchboard

SENTRON Switching and Protection Devices Air Circuit Breakers

FAQs-Main switchboard design criteria

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

GE Power Controls. MiniFORM Switchboards

MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV

know-how Giant in distributing electricity for industry Prisma GK

Securing your electrical installations Prisma,

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

UFES Active protection for switchgear

Quick Connect. quick - simple - efficient.

The complete range of consumer switchboards and switchgear

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

C I R E D 21 st International Conference on Electricity Distribution Frankfurt, 6-9 June 2011

Modular Systems wind portfolio overview Power Collection and Grid Connection products

low voltage switchgear

Portfolio of Solutions. High and Medium Voltage Switchgear

Comparative study for cables and busbars

RENEWABLE ENERGY SUBSTATIONS SOLAR PHOTOVOLTAIC AND WIND POWER. tgood.com. Energy. Fast.

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Extend the Life of Existing Switchgear

CAS 36 Ring Main Unit

R.C.C.B. s two-pole LEXIC

The following components are common to most cubicles; this example is an ABB HK cubicle.

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Permissible ambient temperature Operation Storage, transport

Unit substation solutions with type SIMOSEC primary switches quick reference guide E50001-F710-A389-X-4A00. Answers for energy.

Automation Products. Low Voltage Switchgear MNS System Overview

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

MNS Low Voltage Switchgear System Guide

Choosing for tranquility

Earth Fault Detection Basics in Theory

The standards mentioned in this document

Low Voltage Switchgear MNS is with MSpeed

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Metal-enclosed single busbar, Solid and Air-Insulated switchgear

Medium Voltage Switchgear

What will MV switchgear look like in the future? by Jean-Marc Biasse

IEC and IEEE Standards for High-Voltage Switchgear and Controlgear Present Situation and Future Evolution

Nothing s BetterThan the Original MODAN Power Distribution Systems

Electric Vehicle Charging Solutions

Contents. Description. Product Selection Guide

Catalog. Arc Guard System TM TVOC-2

Modis 25/32. Modular Switchboard Solution

Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation

How To Choose A Transformer

Medium Voltage technical guide. Basics for MV cubicle design

How To Build A Germany Power Plant

COMPARISON OF ANSI/IEEE AND IEC REQUIREMENTS FOR LOW- VOLTAGE SWITCHGEAR

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada

Transcription:

e 2 ALPHA Medium Voltage Switchgear Data Sheet K-1.1.2 EN

We create ideas with power! ELEKTROMETAL ENERGETYKA SA is a new Polish company providing solutions for electrical power engineering. Our services are carried out by a team of experienced professionals. We employ professional engineers, well-known and respected industry experts who have vast practical knowledge and many years of industry experience. The synergy of their competences together with openness to non-standard ideas and the use of modern solutions are ensuring the highest quality of service and create foundation for harmonious, based on dialogue cooperation with our customers. We are winning the trust of our customers through reliability and immediate reaction to their specific needs. Our offer does not cover production and delivery of devices only. We are enriching it by numerous services that maximize performance and minimize customers costs. The biggest benefit for our customers is an innovative method in which we integrate the best and proven solutions for electrical power networks and adapt them to the specific individual needs. They are always up to date thanks to the technical review and modernisation of customer s power grid. We offer MV switchgears dedicated for power industry, heavy industry and mining. Our products are designed on the base of extensive experience, which our experts have been gaining on electrical power market for many years. We continually increase our potential and improve our offer. Our company is developing dynamically and is following industry trends. Transparency of procedures and documents is our standard, our priority is to satisfy customers through reliability, ease of use and intuitiveness of our devices. We believe that good energy in relationship helps both parties achieve a lot more, that s why we take care of personal involvement in the course of cooperation. 3

SWITCHGEAR CHARACTERISTICS e²alpha switchgear belongs to the group of modern, fourcompartment indoor MV switchgears suitable for wall- or self standing installation. The standard range of e²alpha consists of cubicles with a width of 400, 600, 750 and 800 mm. The high degree of operational safety for e²alpha switchgear was achieved by applying an extended system of mechanical and electrical interlocks as well as reinforced mechanical cubicle construction characterized by a high level of arc proofness. APPLICATION e²alpha switchgear is an excellent solution for industrial-, distributionand mining power companies. Advanced design combined with reliable interlocks makese²alpha ideal for applications in the strategic areas of power system where the highest reliability of power supply is required (eg. main point of supply, main switching station, power plants and mines). CUBICLE DESIGN Switchgear cubicle is made of prefabricated steel and Al- Zn plates with thickness of 2 and 3 mm. In the areas particularly exposed to internal arcing and pressure of arcing gases has been applied highquality steel sheet with a thickness of 3 mm with powder ink coating. Additionally, in the case of cubicles made in arc-proofness 31.5 ka/1s, the door of cable compartment and withdrawable module has been provided with additional reinforcements and shields. TYPICAL KINDS OF CUBICLES incoming- outgoing bay-circuit breaker comprising module panel coupler bay circuit breaker comprising module panel coupler bay- cutoff breaker panel auxiliary transformer bay- circuit breaker or disconnector panel voltage measuring panel bus riser panel others- according to customer s needs Presented types of switching cubicles are only examples of basic configurations being used in power industry. On this basis there is possibility of wide development of technical infrastructure of the cubicle through additional switches, transformers, surge arresters and others elements according to the requirement of contractor. 4

ADVANTAGES OF e 2 ALPHA SWITCHGEAR Functionality Reliability Easy adaptation to customer s requirements High level of arc-proofness (31,5kA/1s) The lowest (2100mm) MV switchgear on the market with a compact, rigid design allowing easy access to the LV compartment and easier indicators observation. Upper opening tray for circular circuits enables easy access to wiring (control circuits). Enlarged LV compartment provides possibility for installation protection and control relays in different sizes, it allows also easy start-up, service, technical review and modifications. Integrated modular interlocking system guarantees reliability and an increased level of security throughout the whole operating life. Adjustment is not required within entire lifespan. High-placed MV cable connection (over 550mm) allows simple and convenient installation of cables and provides opportunity for easy installation of various Ferranti transformers as well as easier measurements. Wide channel for control circuits running from below to the LV cassette supports easy and comfortable installation and enables inserting of many control circuits. 550 mm 5

SET OF INTERLOCKS Interlock prevents changing the position of withdrawable module from TEST position to OPERATION position when the circuit breaker is closed. Interlock prevents changing the position of withdrawable module from OPERATION position to TEST position when the circuit breaker is closed. Interlock prevents closing the circuit breaker when the withdrawable module is in intermediate position. Interlock prevents changing the position of withdrawable module from TEST to OPERATION position when the earthing switch is closed. Interlock prevents closing the earthing switch when the withdrawable module is in OPERATION position or in intermediate position. Interlock prevents changing position of withdrawable disconnector module (shortcircuiting switch) from position OPERATION to position TEST, when withdrawable module in the circuit breaker panel is in OPERATION position or in intermediate position between OPERATION and TEST position. Interlock prevents inserting of withdrawable module with lower rated current to the panel with higher rated current. Interlock prevents closing earthing switch when earthed side is under voltage. Interlock prevents opening the door of withdrawable module compartment when withdrawable module is in position OPERATION or in the intermediate position between TEST and OPERATION position. Interlock prevents opening the door of cable compartment when the earthing switch is open. Interlock prevents leaving at the same time in the operating sockets the earthing switch crank and the withdrawable module crank. Interlock prevents closing the earthing switch when the door of cable compartment is open. Interlock prevents shifting withdrawable module in position OPERATION when the door of circuit breaker compartment (of withdrawable module) is open. Electromagnetic interlock of cable compartment (cable termination) in coupler bay without earthing switch. Optional electromagnetic interlock of the back door of cable compartment. Others according to the requirement of contractor. TECHNICAL PARAMETERS Rated voltage of the switchgear 12kV 17,5kV Lighting impulse test voltage (1,2/50μs) 75kV 95kV Power frequency test voltage (1 min.) 28kV 38kV Rated frequency 50Hz 50Hz Rated main busbar current, for incoming and coupling panel 630-1250A 630-1250A Rated current of outgoing panels 630-1250A 630-1250A Rated short-time withstand current (3s) up to 31,5kA up to 31,5kA Internal arc resistance (1s) up to 31,5kA up to 31,5kA Rated peak current strength up to 80kA up to 80kA Degree of protection of the switchgear IP 4X / IP54 IP 4X / IP54 Service continuity LSC2B LSC2B Classification of enclosures PM PM Classification of internal arc resistance AFLR AFLR Cubicle width 400-800 mm 400-800 mm Cubicle height 2100 mm 2100 mm Cubicle depth 1250 mm 1250 mm 6

BASIC DIMENSIONS OF CUBICLES 2100 108 400 600 750 800 1250 STANDARISATION PN-EN 62271-1 High-voltage switchgear and controlgear - Part 1: Common specifications PN-EN 62271-100 PN-EN 62271-102 PN-EN 62271-103 PN-EN 62271-106 PN-EN 62271-200 High-voltage switchgear and controlgear - Part 100: Alternating current circuit breakers High-voltage switchgear and controlgear- Part 102: High-voltage alternating current disconnectors and earthing switches High-voltage switchgear and controlgear Part 103: Switches for rated voltages above 1 kv up to and including 52 kv High-voltage switchgear and controlgear Part 106: Alternating current contactors, contactorbased controllers and motor-starters High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kv and up to and including 52 kv CERTIFICATES & AWARDS 7

ELEKTROMETAL ENERGETYKA SA 02-830 Warszawa, ul. Mazura 18A tel. (+48) 22 350 75 50 fax (+48) 22 350 75 51 biuro@elektrometal-energetyka.pl www.elektrometal-energetyka.pl