Welcome IEEE Members and Guests Jan 20, 2014



Similar documents
NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

The Intelligent AX1 Switchgear for Medium Voltage

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

Secondary Unit Substations

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Primary and Secondary Electrical Distribution Systems

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

Advantages of Fixed Circuit Breaker Switchgear

Safe and secure distribution of medium voltage with AX1

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Gas-insulated switchgear type series 8DN8. up to 170 kv, 63 ka, 4000 A. Answers for energy.

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Technical catalogue TK 503/01 E. ZX0.2 Gas-insulated medium voltage switchgear

High-Voltage GIS yesterday - today - tomorrow

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Unified requirements for systems with voltages above 1 kv up to 15 kv

MEDIUM VOLTAGE SWITCHGEAR CATALOGUE. Code: P2490_xx

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

DF-DT (G) MEDIUM VOLTAGE SWITCHGEAR THE MODULAR CONCEPT. User Manual. SGC - SwitchGear Company nv - Moorstraat 24 - B-9850 Nevele - Belgium

FAQs-Main switchboard design criteria

Unit substation solutions with type SIMOSEC primary switches quick reference guide E50001-F710-A389-X-4A00. Answers for energy.

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Medium Voltage Switchgear

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

MEDIUM VOLTAGE SWITCHGEAR. DI-2, a modular concept combining all mediumvoltage

Remote Monitoring and REC 501 Control Unit Product Guide

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

What will MV switchgear look like in the future? by Jean-Marc Biasse

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

Gas-Insulated Switchgear up to 300 kv, 63 ka, 4000 A Type 8DN9. Answers for energy.

Arc Terminator Active Arc-Resistant Switchgear

Fusible Disconnect Switch

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

Enhance Power Equipment Reliability with Predictive Maintenance Technologies

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

Engineering Specification

Installation, Operation and Maintenance Instructions. Uniflex ABB PTMV

Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

Sample - No Commercial Use

2004 TRANSMISSION SYSTEMS SEMINAR MEDIUM VOLTAGE, METAL-CLAD ARC RESISTANT SWITCHGEAR: ENHANCING WORKPLACE SAFETY

Low Voltage Switchboards The Best Technical Solution for Your Ship

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

Transformer Bushings for GIS

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

UFES Active protection for switchgear

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

SIVACON The Versatile Low-Voltage Switchboard

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Arc Flash Mitigation. Remote Racking and Switching for Arc Flash danger mitigation in distribution class switchgear.

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

CAS 36 Ring Main Unit

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Extend the Life of Existing Switchgear

TMS TANK MANAGEMENT SYSTEM

Safe and reliable distribution network ABB portfolio for medium-voltage indoor applications

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Medium voltage indoor circuit breakers ANSI/IEC solutions

Maintenance Report MEDIUM VOLTAGE POWER STATION 500SC / 630SC / 800SC / 900SC / SC / SC / 1250SC / 1600SC / 1800SC / 2000SC

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

ABB s Disconnecting Circuit Breakers Higher substation availability and lower environmental impact

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Disconnectors and Earthing Switches 36 kv up to 800 kv

Electrical Predictive and Preventative Maintenance

Session Eleven: Development of Standards for MV Switchgear Rated for Arc Protection

PowlVac Vacuum Integrity Tester

Respecting the environment

01.4IB.51200B PowlVac-AR Arc Resistant Switchgear. 5kV & 15kV 1200A, 2000A, 3000A, & 4000A Forced Cooled. Powered by Safety

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

This section applies to the design and installation of transformers.

Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

COMPARISON OF ANSI/IEEE AND IEC REQUIREMENTS FOR LOW- VOLTAGE SWITCHGEAR

SIVACON Low Voltage Switchboard

ADM1TE 5/30A DIN rail single phase two wire energy meter

MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV

BRANDON AND CLARK INC. // SCOTT W. CLARK, P.E. ELECTRICAL CONTINUING EDUCATION ARC FLASH - NFPA 70E

Modular Systems wind portfolio overview Power Collection and Grid Connection products

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation

3AH5 Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

RENEWABLE ENERGY SUBSTATIONS SOLAR PHOTOVOLTAIC AND WIND POWER. tgood.com. Energy. Fast.

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

Transcription:

Welcome IEEE Members and Guests Jan 20, 2014 Copyright Siemens AG 2010. All rights reserved. MEDIUM VOLTAGE GAS INSULATED SWITCHGEAR By Sharif Ahmed of Siemens Canada Copyright Siemens AG 2010. All rights reserved. 1

GIS Gas Insulated Switchgear MV Switchgear since 1950 s Local installation Workshop manufacture Factoryassembled, type-tested Factoryassembled, compact non type tested Air-insulated Air/solid-insulated Cast-resin insulated 2

What is SF6 Its Sulphur Hexafluoride SF6 Gas SulphurHexafluoride is a colourless, odourless, chemically neutral, and inert gas, non-inflammable and 5 times heavier than air, not toxic and not ozone depleting. 3

Is SF6 a Health Hazard Pure SF 6 is physiologically completely harmless for humans and animals; it s even used in medical diagnostic. Due to its weight it might displace the oxygen in the air, if large quantities are concentrating in deeper and non ventilated places. Legislation for chemicals does not categorisesf6 as a hazardous material. Is SF 6 harmful for the environment? It has no ecotoxicpotential, it does not deplete ozone. Due to its high global warming potential it may contribute to the man made greenhouseeffect, if it is released into the atmosphere. However in electrical switchgear the SF 6 gas is always used in gas-tight compartments, greatly minimisingleakage. This make the real impact on greenhouse effect negligible 4

SF6 Gas Insulated Switchgear What is Gas Insulated Switchgear The Switchgear where SF6 Gas is the insulating medium. Why this Gas is chosen for insulation medium? Lets see the characteristics of SF6 gas Characteristics of SF6 Gas Non-poisonous, non-flammable, inert, self-restoring insulation Dielectric strength 6x better than air Low current arcs are self-extinguishing SF 6 only insulates not used for interrupting, therefore, no arcing byproducts. No oxidation inside of enclosure Gas leakage rate < 0.1% annually 5

What is Medium Voltage Vacuum GIS? Gas Insulated Switchgear where the insulation Medium is SF6 - Low pressure SF 6 used as an insulating medium for all primary components Because of the SF6 under pressure Dielectric strength is 6x better than air With a higher Insulation the distances between the live parts and earth are reduced. Because of the reduced clearances between the life parts the size of the Switchgear is reduced and you get a much smaller foot print of the Gear. Vacuum interrupter technology is used in GIS Gears Circuit Breakers are fixed mounted in GIS Gears What is Medium Voltage Vacuum GIS? - Primary components are virtually maintenance-free due to controlled gas environment SF 6 for lightning withstand level is up to 200 kv BIL at 38 kv Integral disconnecting is by the use of a three position selector switch: -- Connected, Disconnected & Ground Positions The Vacuum interrupters used are good for up to 30,000 normal operations and 50 fault operations. Make-proof earthing by means of the vacuum circuit-breaker Hermetically bolted / Sealed switchgear housings Cable connections are with inside-cone plug-in system, or for connection of gas-insulated and solid-insulated bars Very small foot prints 6

Three phase encapsulation Gas Insulated Switchgear Single Phase encapsulation (W600mmxD1625mmxH2350mm) Key Features MV Vacuum GIS Offers high reliability Offers high flexibility through modular design Offers high safety by Inherently Arc Resistance isophase design Features small foot print design for total cost savings Increased immunity to the surrounding environments Maximizes revenue and profit by low maintenance Delivers low a total cost/risk of ownership over product life cycle 7

Arc Resistant Arc Resistant AS PER ANSI ANSI 37.20.7-2007 For Major Operational Activities, Reduced Level Of PPE Can Be Used For MV GIS Comparison of PPE 3 level required for operations Activity Open/close circuit breaker Isolate circuit MV Air-Insulated Switchgear (AIS) 1 HRC 2 (door closed) 2 HRC 4 (door open) HRC 4 (racking, door open or closed) (Note: isolation in metalclad requires racking to test or disconnect position) MV GIS HRC 0 HRC 0 (operation of three-position switch to open position) Application of safety grounds HRC 4 HRC 0 8

Technical Data * Maximum IEC IEC ANSI IEC IEC ANSI Rated Voltage (kv) 7.2 12 15 17.5 24 38 Rated Power Frequency Withstand Voltage (kv) Rated Lightning Impulse Withstand Voltage (kv) Rated Short Circuit Breaker Current* (ka) Rated Short Time Current 3 Sec* (ka) Rated Short Circuit Making Current* (ka) 20 28 36 38 50 80 60 75 95 95 125 200 40 40 40 40 40 40 40 40 40 40 40 40 104 104 104 104 104 104 Rated Busbar Current* (A) 5000 5000 5000 5000 5000 5000 Maximum Circuit Breaker Rating* (A) 4000 4000 4000 4000 4000 4000 Main Applications for Medium-Voltage Switchgear G Generation level and high-voltage system x x Primary distribution level x x x x x x x Secondary distribution level x Low voltage 9

Single Bus bar & Double bus bar single phase encapsulated Gear Single Bus bar Double Bus bar Situation with Gas-Insulated Switchgear Today s state of the art is gas-insulated switchgear with the following main benefits: Small, compact dimensions Independent of environmental effects and climate Widely maintenance-free Maximum safety for staff Low fire risk Arc-fault tested Advantages: Low invest for buildings due to compact dimensions and climate-independent design Maximized power supply reliability Maximum personal safety Lowest life cycle costs Reduced operational costs 10

Maximum Security of Operation Separate compartments for busbarand circuit-breaker offer a maximum degree of availability Busbar( in operation ) Attention: High voltage Feeder earthed ( earthing) Circuit-breaker Access without danger to current transformer, feeder voltage transformer, cable plugs, operating mechanisms Bus bar Design Busbar housing Busbar Three-position switch Pole housing 11

Busbars of higher ratings upto 5000A Busbar Twin busbar housing Thee-position switch Busbar Pole housing Single BusbarSwitchgear: Cross Section of Single Pole 3 6 1 2 4 5 1 7 1 8 1 Cast aluminum Alloy housing 2 Busbar with sliding supports 3 Three-position selector switch 4 Gas tight bushing 5 Vacuum interrupter 6 Toroidal-core current transformer 7 Capacitive voltage sensor 8 Shock-proof cable termination 12

Vacuum interrupter mounted in Circuit Breaker pole housing Cast Resin Bushing separating Gas Chambers Routine tests including: X-ray test High voltage test (HV) Partial discharge test (PD) Helium leak test 13

Vacuum Interrupters Proven Vacuum Interrupters Rated peak and/or making current I I P Peak current I p =κ " 2 I k IEEE: I ma or I P = 2,6 I k at60 Hz IEC: I ma or I P = 2,5 I k at 50 Hz 2,6 I k at 60 Hz 2,7 I k at 50 Hz ifratiox/r > 14 (i.e. τ> 45 ms) 14

Interrupters used in GIS -The interrupters used are designed for 30,000 normal operations. - 50 Fault operations -The Breakers are normally operated at 5 cycle -The Breakers can also be operated at 3 cycles if requested by the client. - The symmetric value of short circuit current is 40kA. -Max making current 104kA which is asymmetric value of current. -The short circuit ratings offerredby different manufactures are 25kA, 31.5kA and 40kA. Compartmentalization 15

Manometer for checking Gas pressure Gas pressure manometers arranged at the switchgear front Gas pressure can be read with security even without auxiliary voltage supply Optionally with independent of ambient temperatures Optionally with independent of site altitude With two signalling contacts for gas pressure too low and gas pressure too high indication Optionally with three signalling contacts for gas pressure too low / very low and gas pressure too high indication Three Position Selector Switch ON OFF GROUNDED 16

Viewport for Three Position Switch Three Position Selector Switch View by Camera Web cam designed Cameras outside of the gas chambers with plug and play Fire wire /USB2.0 Connections to any laptop Design via Video Cameras 17

View Port via Video Camera For Disconnector and Grounding Switches Three Postion Switch Three Position Selector Switch Circuit CLOSED Circuit OFF Circuit Ready for Grounding Circuit Grounded 18

Feeder Earthing with the Circuit-Breaker 1) Close the earthingswitch of the three-position switch Ready to earth Electrical OFF-signals are suppressed 2) Close the circuit-breaker Feeder earthed 3) Padlock the feeder earthed interlock The circuit-breaker is blocked mechanically Signalling contact: Feeder earthed (option) Lock out Tag out 19

Operation of Three Position Switch Switch position indicator Disconnector switch Operating shaft Disconnector switch Operating shaft Earthing switch Switch position indicator Circuitbreaker switch Operation of a Single Phase Encapsulated GIS 20

Operation of a Single Phase Encapsulated GIS Switch position indicator Disconnector switch Switch position indicator Circuit-breaker switch Ready-for-service indicator Filling valve Opening for charging the circuit-breaker spring by hand Spring charged indicator Counter Operating shaft Disconnector switch / Earthing switch Preselection key Switch position indicator Earthing switch ON pushbutton Circiut-breaker switch OFF pushbutton Circiut-breaker switch De-earthing interlock Circuit Breaker operating mechanism 21

Operating Tools Interlocks (Selection) Interlocks are designed according to IEC 62 271-200 Standard interlocks Three-position disconnector against circuit-breaker mechanical Disconnector against earthing switch (within three-position disconnector) mechanical Locking device at the circuit-breaker switch Locking device at the three-position disconnector switch Additional interlocks Electromagnetic interlock at the three-position switch / disconnector switch Electromagnetic interlock at the three-position switch / earthing switch 22

Current Measurement Toroidal(Window) Type Current Transformer Conducting paths form the primary winding, free from dielectric and thermal stress Secondary components outside enclosure and easily accessible No dielectric stress on cast resin components Current Measurement Ring-core current transformers: Main circuit as primary part without dielectric and thermal problems Secondary part accessible outside the enclosure without hazard Free of dielectrically stressed cast-resin parts. 23

Fused Busbar Voltage Transformer Single-pole insulated SF 6 filledgas switch compartment Protectionofbusbarbygastight barriers Safely removal using ground switch Fused and disconnectable Line Side (Cable Side) Voltage Transformer Plugged-in panel connection Metal-enclosed Either plugged-in directly or mountedseparatelyand connected via a plug-in cable Completely shockproof Outside main circuit Mounted Separately Plugged-in Directly 24

Line-Side (Cable-Side) Voltage Transformer Line-side (cable-side) voltage transformer: Plugged-in panel connection Mounted separately and connected via a plug-in cable Grounded Metal-enclosed Wye/ Wyeconnected 100% shock proof Voltage transformer Outside main circuit. Capacitive voltage indication potential indicator C 2 or C 1 indicator coupling electrode built into the pole-support plate of the circuit breaker for checking for dead state of each pole 25

Low-Voltage Compartment Height: 850 mm 1200 mm (option) Removable, bus wires and control cables plugged in (via 6 or 10-pole coded module plug connectors) Panel control via conventional control devices or digital bay controller Customer-specific equipment (protection, control, metering, annunciation) Wiring in H07VK, optionally also heat-resistant and halogen-free Plug-in Cable termination system 26

Various multiple cable terminations Single Cable Plug-in 2 or 3 Cables per Phase with Plug Size 3 6Cables per Phase With Plug Size 1 to 3 Termination for Tubular Gas Bar Surge Arresters Termination for Solid-Insulated Bar Plug-in cable termination system cable screen pressure spring Pressure sleeve insulating and field controlling part plug-in socket test lead bell flange capacitive divider inner-cone system acc. DIN 47637 metal-enclosed, all-insulated dead front integrated capacitive voltage tap for checking for dead state 27

Cable connector Dummy connector 28

Cable connections in GIS 25kV AIS Line-up 29

Physical Dimensions & Number of Cells of AIS 25kV GIS for same Switchgear 30

Number of Cells and dimensions for GIS A Closer Look at GIS vsais GIS Requires 20% of space needed for air- insulated designs 31

Switchgear Size Comparison between 38 kv AIS and GIS Outdoor Open type Circuit Breakers Air Insulated Switchgear GIS Insulated Switchgear 278 ft 2 26 m 2 100% 91 ft 2 8.5 m 2 33% 18 ft 2 1.5 m 2 6% Space problem? Go for GIS Space Problems? I have to double the substation MVA, but don t have the space? 24 330 cm 130 24 48 min. rear access 38 kv Switchgear Space Requirements Air Insulated 91 ft 2 =8.5 m 2 Gas Insulated 18 ft 2 = 1.5 m 2 155 cm 60 48 min. aisle aisle space 48 96 drawout space 32

Lightning impulse withstand voltage with gas leakage, 200 kv 170 150 rated value lightning impulse withstand voltage 100 80 50 SF6/Luft 6 /air mixture (%) at Gemisch atmospheric in % pressure bei 1 bar abs. SF 6 at gauge pressure 15 19 22 25 26 psi 0/100 50/50 100/0 1.0 1.3 1.5 1.7 1.8 bar Normal Atmospheric Pressure gas pressure (abs.) AIS VS GIS Advantages of using 35kV GIS in comparison to 35kV AIS Switchgear Dimensions AIS GIS Width: 1500mm Width:600mm Depth: 2400mm Depth:1625mm Area per Section 3,6m2 Area per Section 1m2 Operating Aisle 1.5m Operating Aisle 0.8m Example with 10 sections: Area required AIS 36 m2 Operating Aisle 23m2 Example with 10sections: Area required AIS 10m2 Operating Aisle 5m2 33

AIS ADVANTAGES OF GIS GIS AIS maintenance will be GIS maintenance will be required after 5 years of service. required after 5 years Maintenance means: Maintenance means: Switch off of lines, feeder Visual Inspection and busbars Grounding All CB s in test position Test function of CB s and all other switching devices Remove the draw out section and dismantle panels partly in order to get access to busbars and cable sections AIS MAINTENANCE Clean the panels from dust Lubricate all bearings and surfaces Check panel function and put board back into service Estimated time per panel: 4 hours Estimated cost per hour: US$ 100 For 10 panels: Estimated time : 1 week Estimated cost : US$ 4000 Shutdown time for customer process machines is not considered 34

AIS VS GIS Advantages using MV GIS in comparison to MV AIS Availability AIS During maintenance period, the switchgear is out of service. Provisions for alternative supply routes must exist. Switching over procedures need to be followed After maintenance original conditions need to be established GIS -GIS S/G is maintenance free - No human errors can occur due to hermatically sealed isolation.therefore peace of mind for customer will be ensured. ADVANTAGES OF GIS IN COMPARISON TO AIS Following risks have to be taken into account by using AIS switchgear: Switching failures Disturbances in the network may appear Human errors may occur due to left tools, loose connections, unscrewed bolts, unfixed covers etc. Therefore the risk of failures inside the switchgear (arc fault) is very high. 35

ADVANTAGES OF GIS IN COMPARISON TO AIS AIS Environmental Aspects GIS Influence of dust, humidity and vermin to all active parts as busbars, breakers, cable connections: Need of maintenance, sequence depending from environmental Influence By high humidity hygrometer and or heaters in cable compartment is necessary. Therefore additional costs and control is necessary By vermin's, special measurements in building, cable compartments, switchgears, such as alarming, shielding etc. are necessary. No enviromental influence to maintenance free, Hermatically sealed S/G. Busbars are single pole gas insulated and probability of internal faults are substantially reduced and flash over between phases is not possible No influence of insulation level.peace of mind. Environmental Problems Dust? Salt? Moisture? Corrosive gases? Mice? Rats? Cats? Squirrels? Snakes? Altitude? 36

ADVANTAGES OF GIS IN COMPARISON TO AIS AIS Therefore additional costs and control is necessary. Flash over between phases are possible and busbar differential protection may be required. Influence of altitude: With increase of the altitude, the insulating capacity of insulation in air decreases due to the decreasing air density. Depending on the altitude a correction factor has to be taken into account. GIS No influence of altitude on insulation level. ADVANTAGES OF GIS IN COMPARISON TO AIS Spare Parts AIS GIS For an estimated live time of 30 years the following spares have to be taken therefore Into account by using AIS technology: Lubricants, screws, bolds, nuts, contact fingers for draw out unit Isolators, bushings Therefore additional cost for spares and storage room will arise for the customer. Further more staff for exchange the parts have to be provided. No spares for high voltage portion are required no additional cost for spares & storage. 37

Reliability AIS By using AIS switchgear, risks of failures due to human error, maintenance, environmental aspects and switching in network will appear. GIS None of the AIS mentioned risk factors will appear by using GIS equipment. Therefore GIS switchgear has a much more higher contrast to AIS Switchgear. 10 yearlifecyclecostforais versus GIS switchgear Description Frequency in 10 years (AIS) Duration (days)/qty Cost AIS GIS *Indoor substation A A+ Arc Resistance B 0 Real Estate 40' X 18' vs. 21' X 10' $/ sqf C C - crane vs. forklift / Installation at site manhours D D - Spare breaker 1 $ E 0 Grounding Device 1 $ F 0 Routine Maintenance Interval 3 5 $/hour E E - **SuitsaccordingtoNFPA 70E 5 $ F 0 Outage maintenance 1 5 $/hour G 0 Lost of production priceless - - No phase to phase fault priceless Total: H H -25% cheaper * IndoorSubstation 27kV, 31.5kA, 1200A -Typical10 sectionlineupwith2 mains, 1 tie, and 7 feederbreakers ** Arcflashsuitsrequiredwhenrackingnon-arcresistanceequipmentabove1000 volts 38

Customer Benefits Environmental Independence Compactness Maintenance-free Design Personal Safety Security of Operation, Reliability Economy, Ecology General Information The gas-insulated switchgear is for application in nearly all branches like:- Airports & Ports Automotive Buildings Cement Industries Chemicals & Pharma Contractors Food & Beverage General Industries Mining Offshore Industries Oil & Gas Paper Industries Semicondor Steel & Aluminium Industries Utilities Transportation & Railway Water Windfarms 39

GIS is used in the following Industry Steel and Aluminium Industry Utilities Oil - Offshore Transportation Systems Wind Farms Offshore Mining GIS is used in the following Industry Oil & Gas Chemical Tourism & Hotels Paper Automotive Food & Beverage Airports & Airlines 40

GIS Market environment Market Trend outlook GIS GIS High developed market Emerging GIS market White spots for GIS AIS 2007 GIS 27% 73% CAGR +6% AIS GIS 2000 20% 80% AIS CAGR +4,5% Thanks Thank you for your attention Questions? 41