Keep it Simple Timing

Similar documents
To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

PL-2303 (Chip Rev H, HX, X) USB to Serial Adapter Windows Driver Installer Manual

INSTALLING AND USING ENTEL PROGRAMMER IN WINDOWS 7 Technical Support Bulletin

Guide to Installing BBL Crystal MIND on Windows 7

Current Cost Data Cable User Guide. Installing and configuring the data cable

PC Program User s Guide ( ) 1. Connecting the PC. 2. Installation and Start-up. 3. Programming

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

User Manual. Thermo Scientific Orion

AUDITVIEW USER INSTRUCTIONS

TP- 051 GPS RECEIVER

L Firmware And FPGA Configuration Upgrade

Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips

Wrist Audio Player Link Soft for Macintosh. User s Guide

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES

USB3.0 Docking Station. User Manual (DA-70546)

PM1122 INT DIGITAL INTERFACE REMOTE

IP SERIAL DEVICE SERVER

Package Checklist. Overview. Features. USB Data Link Cable User s Manual. USB Data Link Cable User s Manual 1

VM-4 USB Desktop Audio Device Installation Guide

Dell Statistica Statistica Enterprise Installation Instructions

VM-8 USB Desktop Audio Device Installation Guide

hp digital home networking wireless USB network adapter hn210w quick start guide

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

Corsair Flash Voyager USB 2.0 Flash Drive UFD Utility User s Manual

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Imation Clip USB 2.0 Flash Drive. Imation Drive Manager Software. User s Manual

USER S MANUAL USB FILE TRANSFER CABLE

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

Maintaining the Content Server

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

How to setup a serial Bluetooth adapter Master Guide

Setup and Configuration Guide for Pathways Mobile Estimating

PN L, Revision B, October Epic 950 TM. Master Programmer User s Guide

Bluetooth Version FUZZYSCAN FAMILY. Quick Start Guide WIRELESS SCANNER

Prolific USB to SATA Bridge Controller Backup Software User s Manual

AUDITVIEW USER INSTRUCTIONS

Running the R4 Software on a USB Port

Installation Instructions For Controllers with MS/TP Automatic MAC Addressing. Patent Pending

AC-115 Compact Networked Single Door Controller. Installation and User Manual

JTAGjet. series SIGNUM SYSTEMS CORPORATION. USB 2.0 Driver for JTAGjet and ADM51. Installation Instructions

T3 Mux M13 Multiplexer

ABB solar inverters. Installation and setup instruction Aurora Manager TL software and ABB PVI-USB-RS232_485 adapter

User's Guide DylosLogger Software Version 1.6

Hi-Speed USB 2.0 Flash Disk. User s Manual

Installing USB Drivers With Microsoft Windows XP

How To Download From A Tachograph With A Tachoreader Combo (Tachograph)

Configuring the Switch with the CLI Setup Program

ScanWin Installation and Windows 7-64 bit operating system

Bluetooth HC-06 with serial port module Easy guide

BASLER ACE QUICK INSTALLATION GUIDE

In-System Programmer USER MANUAL RN-ISP-UM RN-WIFLYCR-UM

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS. Quick Start Instructions

SAPIP GUI INSTALLATION. Table of Contents

Config software for D2 systems USER S MANUAL

Ethernet Radio Configuration Guide

how to upgrade your IsatPhone

Using the Parani SD1000U/SD1000 with Carlson SurvCE

User Manual. USB2.0 to IDE and SATA Adapter Cable. Model: DA-70202

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.

Crow Limited Warranty. Print Version 017

FN:PCMCSET-M1.DOC. PCMCSET SOFTWARE for ATS Master Clocks System Clocks and Displays

PowerShield SNMP Adaptor

Iridium Extreme TM Satellite Phone. Data Services Manual

3.5 EXTERNAL NETWORK HDD. User s Manual

Wireless Network Adapter Installation

DSA-1000 / PRT-1000 Device Server / Thermal Printer

Table of Contents. Creating a VC1000 Network... 3

Agilent Automated Card Extraction Dried Blood Spot LC/MS System

Chord Limited. Mojo Dac Headphone Amplifier OPERATING INSTRUCTIONS

PDA Software Manual For the Windows CE and Mobile Operating Systems

DUKANE Intelligent Assembly Solutions

SubCue Analyzer Software - Introduction

INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Application & Quick-Start Guide

Driver Installation and Hyperterminal Operation of iload Digital USB Sensors

Features Reference. About Unified Communication System. Before Using This Machine. Starting a Meeting. What You Can Do During the Meeting

Procedure for updating Firmware of EZ4 W or ICC50 W

DLP USB Scroll Control. Configuration Guide for QBox

SPC-1. Single Point Controller. Operation Manual

Setting up Digi Connect Wi-SP or Digi ConnectPort TS W Devices On a Secured Wireless Network for use with Veriteq viewlinc

USER S MANUAL USB TO IrDA ADAPTER

Table of Contents. Safety Warnings..3. Introduction.. 4. Host-side Remote Desktop Connection.. 5. Setting Date and Time... 7

Installing PowerLink on Windows 7 64-bit

The following items are trademarks or registered trademarks of Kaba Mas in the United States and/or other countries. GITCON

Plug-in Installation Instruction Xenon 1900/1902 Scanner

Clickfree Software User Guide

BMV-602 Data Link Manual

How To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline

BW-500 BED WEIGHER USER MANUAL

Installing Global Logger USB Drivers

File Management Utility. T u t o r i a l

Chapter 2 Installation

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

GETTING TO KNOW YOUR PRE-PAID TELSTRA WI-FI 4G

ThermochronWM22 Application for Windows Mobile Getting Started. Step 1: Install PC Applications Step 2: Install USB Adapter...

Guide for Remote Control PDA

Getting Started. rp5800, rp5700 and rp3000 Models

Colorfly Tablet Upgrade Guide

Transcription:

Keep it Simple Timing Support... 1 Introduction... 2 Turn On and Go... 3 Start Clock for Orienteering... 3 Pre Start Clock for Orienteering... 3 Real Time / Finish Clock... 3 Timer Clock... 4 Configuring the Clock... 4 Quick Synchronisation *... 6 SLOW the clock. *... 6 Charging the battery... 7 Installing Software... 7 Installing the Serial/USB adaptor... 7 Serial Communication Messages... 9 Finisher or Lap Times... 9 Support Please contact Ted Finch at kitst@finchhouse.org. Disclaimer The KitST clocks are designed to support the timing of sport and recreational events and are not designed to support life support or 'mission critical' systems. Information in this document is subject to change without notice. The manufacturer does not make any representations or warranties (implied or otherwise) regarding the accuracy and completeness of this document and shall in no event be liable for any loss of profit or any other commercial damage, including but not limited to special, incidental, consequential, or other damages. No part of this document may be reproduced or transmitted in any form by any means without the express written permission of the manufacturer. All brand names and product names used in this document are trademarks or registered trademarks of their respective holders. The clock specification and software is subject to revision from time to time. The latest version of the software can be obtained from KitST. The upgrade entails exchanging the microprocessor chip. Ted Finch trading as KitST, Keep it Simple Timing. 1

Introduction The KitST Clock is designed to provide an easy to use display clock for timing sports and other activities. The bright LED display shows Hours, Minutes and Seconds in a 24 hour format. The clock also has a battery backed Real Time Clock which maintains the time when the main display clock is turned off. Once the clock has been configured then in most cases the clocks 'Turn on and Go'. Adjustments to the clock are made by sending commands via the serial port from a PC terminal programme or the supplied software. KitST Clock Display @ 13:26:08 KitST Rear showing switches and connectors. 2

Turn On and Go Slide the Off-On switch to the right. The clock will (re)start with the saved settings and display the time based on the data obtained from the battery backed Real Time Clock Start Clock for Orienteering In Orienteering Start mode the clock gives a warning beep at 50 seconds, count down beeps from 57 seconds and a long BEEP at Zero. Competitors can be reminded to 'Go on the Long Beep'. For large events a second clock can be used as a Pre Start / Call up Clock. In pre start mode the displayed time is offset by the Pre Start delay normally 3 minutes. If the start time is 11:15 then the pre start shows 11:18. Starters then move forward through the start boxes each minute and start at the correct time. The Start Interval is 1 minute by default but can be adjusted to give a 30 second interval or 2 to 6 minute interval. Typical Start Layout for Orienteering or Time Trial event Start -1 Box Start Clock Go on the Long Beep -2 Box. Maps on Display Call up -3 Box. Pre Start Clock Collect Descriptions Pre Start Clock for Orienteering In Pre Start mode the clock display is offset by the Pre Start setting and gives a long BEEP at each Start interval. Real Time / Finish Clock The clock can be used as a Real Time Clock for example to show the time at the Finish line. In this mode the Buzzer would be OFF. For Orienteering the Real Time display can be used as a Finish clock to enable competitors and officials to note the finish time. If required the Push Button on the rear of the clock can be used to send finish times via the serial port for processing on a computer. As an alternative to the Push Button an optional hand held push button can be used. The hand held push button is attached to the connector on the lower right of the back of the clock. Align the 4 pins of the connector and secure the connector by screwing up the 'lock ring'. A short press of either button will transmit a lap or finish time. 3

Timer Clock The clock can be started in Timer mode by holding down the Push Button (or optional Hand held Push Button) for 3 seconds when turning on the clock. The clock starts with a 00:00:00 display. Push the button to START the timer. Push the button to transmit Lap times to a computer via the serial port. Hold the button down to STOP the timer. Push the button to RESET to Zero. (Short and Long Beeps give feedback when using the push button) Configuring the Clock The clock can be configured using the supplied KitST Configure software or a standard 'Terminal' application such as HyperTerminal. The software permits settings to be adjusted and then to be sent to the clock via the serial communication port. The time and other settings are retained in battery backed memory and are retrieved when the clock is turned on. Connect a serial communication cable from the clock to the serial port on the computer and start the KitST Configuration application. Initial Screen - note buttons are not active as no connection has been made. 4

Press Com Settings to select a COM port and set the communication protocol to: Port Baud Rate 9600 Data bits 8 Stop Bits 1 Parity Flow Control Free Com port or USB adaptor port e.g. COM2 None None Press OK when done. Press Connect to connect the software to the clock The top right box shows the data received from the clock. Normally only the two setting on the left need to be used. Select Start Interval Off, 1, 2 etc., Select Summer Time On or Off and the Pre Start Minutes offset as required and Press Update Settings. To set the clock time either select PC Time or manually set the required time then Press Update Clock. 5

To set the clock mode as a Start, Pre Start or Finish clock select the Mode and Press Send Mode. In Start mode the clock sounds the countdown beeps. In Pre Start mode the clock only sounds a beep each minute. In Finish Mode there are no beeps. To manually synchronise the clock to another time source: De select the PC Time option and adjust the Hours, Minutes and Seconds using the scroll arrows and press Update Time when the reference clock changes. To just synchronise set the seconds to Zero to synchronise the clock enter Z into the Send Data box and press Send Data when the reference clock changes. Note that clock minute will advance if the seconds had already reached 30 seconds. A full list of all the message formats is given in a later section. Quick Synchronisation * * Available from March 2012 To synchronise two clocks: Decide which clock is the Master Clock. Turn off the two clocks. Connect the 'null modem' serial cable to the two clocks. Turn on the Master Clock. Wait for the master clock to show the time. Turn on the Slave clock. The Slave clock will synchronise to the Master clock. The cable can then be disconnected and the clocks set out as required. SLOW the clock. * * Available from August 2012 The time display can be delayed using a temporary Time Zone. To delay the clock use the push button: Long Press to enter adjust mode minute dot flashes. Short Press to delay by a minute. Repeat as required. Long Press to move to hour hour dot flashes. Short press to delay by an hour. Repeat as required Long Press to complete. Further adjustments can be made as required. To reset Time Zone - turn off then turn on again. 6

Charging the battery The main battery is a re-chargeable NiMH battery. Note that NiMH batteries do slowly lose their charge when stored for long periods so the clock should be re charged shortly before use. NiMH batteries can be 'topped up' and do not suffer the memory effect of NiCad batteries. The charger comprises a transformer which is plugged into the mains and a small charging unit. The output from the charging unit should be connected to the charge socket on the clock and the power switch pushed to the right or OFF position. Typically the light on the charger shows RED whilst charging and GREEN when charging is complete. A 2600maH battery should give 6 hours use; a 3300maH battery should give about 7.5 hours of use. When the battery runs down the main display will dim leaving only the dots illuminated. The battery backed real time clock will retain the time when the main display is turned off. The back-up battery has an estimated life of 3 years before replacement is required. If the Real Time Clock time 'drifts' significantly then it is time to replace the backup battery. Contact KitST for instructions. Installing Software Configuration Software The installer KitST-setup.msi on the CD will install the application KitST_Configure.exe into C:\Program Files\KitST and place a short cut on the desktop. Installing the Serial/USB adaptor On computers without the old style 9 pin serial port a USB to serial converter may be used. The optional USB Serial adaptor will be supplied with driver software which creates a virtual serial or communication port. The following information is typical as adaptors vary in the software that is used. Software installation for the Serial/USB adaptor will depend on the version of Windows used and the security settings. Software driver for adaptor is normally supplied on the CD (look for the USB folder) but may also be downloaded from the relevant manufacturer's web site. To use the configuration software you need to verify which COM port has been allocated to the adaptor. To verify that the adaptor has been installed correctly and to locate the COM port assignment: Click Start - Control Panel - System. Inside System Properties, click on Hardware - Device Manager. Double-click on Ports (COM & LPT1). You should see the USB Serial adaptor device listed. Note the COM port e.g. COM3 for use with the KitST configuration software. You can allocate an alternative COM port by double-clicking on the device name to show Properties, select Port Settings then Advanced. In Advanced settings select COM Port Number and choose an unallocated number. If possible choose COM1, COM2, COM3 or COM4. 7

8

Serial Communication Messages Any suitable terminal programme can be used to transmit data to the clock over a serial port as an alternative to the configuration software supplied. The clock transmits a Menu and will accept and respond to the following commands. The protocol is 9600 baud, 8 bit No parity. Beep B0 Buzzer OFF B1 Buzzer every 1 Minute B2 Buzzer every 2 Minutes. B6 Buzzer every 6 Minutes B9 Buzzer every 30 Seconds Daylight Saving Time (Summer Time) D0 DST OFF D1 DST ON Pre Start Delay (This setting is only used when a clock is in Pre Start Mode) P0 No Pre Start Offset P1 1 Minute Offset P9 9 Minute Offset Quit Quits the Menu and enables transmission of the time each second. Normally only used for test purposes. Send again to quit the transmission of times and returns to the Menu. Q Zero Zero seconds to synchronise the clock. If seconds are 30 or more then the clock moves forward to the next minute. Z Time Time can be set by sending T followed by the Hours, Minutes and Seconds. The figures should be in 24 hour format with leading zeroes. e.g. T130745 Thhmmss Mode The Clock Mode can be set by sending @ followed by F, P or S @F Finish Mode: No Beeps. Use this mode for a Real Time Clock. @P Pre Start Mode: Warning beep each start, adjusted by the Pre Start delay. @S Start Mode: Count down beeps and BEEP each start. The time and other settings are retained in battery backed memory and are retrieved when the clock is turned on. Finisher or Lap Times The data transmitted when the push button is pressed consists of a sequence number and the time of the button press. The two datum are separated by a TAB character. (0x09) and the record is terminated with a CR LF pair (0x13 0x10) nnnnn 0x09 hhmmss 0x13 0x10 When the Timer is stopped with a long button press the stop time is transmitted. STOP 0x09 hhmmss 0x13 0x10 The received data may be used by suitable software to create race results. 9