SunnyMec 3000 The innovative bi-axial PV tracker Data Sheet



Similar documents
SOLAR TRACKING SYSTEM

2 Axis Solar Tracker / 12 Kw

HORIZONTAL INSTALLATION

PREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS

Assembly Instructions for the InteliTrack 3000 Rail Tracking System

INSTRUCTIONS FOR USE

39HQ Airovision Air Handling Units

ENGLISH FORK GUIDE 2013

SUSPENSION AND STEERING OVERVIEW

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

PITCHED ROOF STRUCTURES

Embedded Parts Introduction - Anchors

Technical handbook Panel Anchoring System

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

Application case - Solar tracking system

INSTRUCTIONS: LocknCharge Laptop Carts

ACTIV-8 PLUS Insulated Conductor Bar

BLADE S-MAX Cabinet for Blade Server

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

Fixturing systems Fixturing systems for measurement technology

Installation Detailed installation instructions are provided which should be strictly followed.

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Solar Tracking Application

Saferand easierinstallation

FRACASSO SCAFFOLDING PS 720

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

1.1 DIMENSIONS AND WEIGHT PAG LOAD CENTRE FOR LIFTING PAG STORAGE CONDITIONS PAG. 2

Solar Mounting System

DESIGN BY: ARCH. GIUSEPPE INZITARI

Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware.

A product made in Australia. Insulated Conductor Rail ACTIV-8 PLUS

Video conference solutions

Machine devices, jig devices

Small Flat Panel Lift Arm FSA-1004 and KSA-1004

Installation manual ValkPitched - Clamp

lindab duct suspension & support system Duct suspensions & Support systems

00MK-MA0190-EN00. Mounting System ASSEMBLY INSTRUCTIONS. Universal Light system with locking brackets, for sloped roof

Three Channel Optical Incremental Encoder Modules Technical Data

Installing Cisco TelePresence MX200 G2 - Wheel Base

Installation manual ValkPitched - Insert

UNIVERSAL RAILING, STEEL

MultiPost-AP anchorage device

SMART IN DESIGN AND FUNCTION

These Installation Instructions are valid for antennas in the following version:

Oceanscience Cable Chimp II Cableway ROV System User Guide and Warranty

SSG PRODUCTS FOR SHIPS AND OFFSHORE

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Video conference solutions

Technical Information

RAIL FREE SOLAR ROOF MOUNT

Mounting Instructions for SP4 Power Modules

Machine Screws, Dowel Pins and Hardware

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Technical feasibility of the reconfiguration of 8-m class telescopes

PV Mounting System For Crystalline Solar Module THE POWER OF ASTRONERGY

Guidelines for Earthquake Bracing of Residential Water Heaters

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

Vandal-proof keypad series

Power consumption (kw)

Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars

I BEAM TRACK INSTALLATION

How To Use A Power Supply On A Powerline 2.2 (Ai)

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Thermometer in stainless steel with capillary and switch contacts

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Residential Deck Safety, Construction, and Repair

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

OVERALL CONVEYOR WIDTH STEEL ALUMINUM MODEL # PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT.

4 Posiflow Proportional Solenoid Valves

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

Remote Head REMO ONE. Code Manual

EC DECLARATION OF CONFORMITY FOR MACHINES

TECHNICAL INFORMATION

Operating Instructions Drill rig DRU160

Research RF Sputtering Packages

MONDOATHENS BASKETBALL SET (Reference PK110)

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

ŠKODA MACHINE TOOL HORIZONTAL MILLING AND BORING MACHINES ŠKODA HCW

PERMIT APPLICATION REQUIREMENTS FOR RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEMS

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Manual piston sampler...m 11

SPECIFICATIONS FOR TENDER NO: PSNR/SCP/VKS/E 1635 ANNEXURE I TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST

Fredriksons conveyor systems handle goods with a width from 20 mm up to 600 mm.

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

kymanual or Automatic - it s your Choice

LED LEONARDO 120 W. LED Fresnel SPOTLIGHT White light, either Tungsten or Daylight balanced Correlated Color Temperature

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Security steel door dw 52-1 Teckentrup DF WK 2 optionally with glazing/ventilation grille

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

How to secure your property after a disaster

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

T 300 Tray sealer. Automatic tray packaging in the smallest of spaces

MODEL HSR-007 Direct Drive Rolling Steel

Morgue refrigeration unit

METHOD OF STATEMENT FOR STATIC LOADING TEST

Transcription:

SunnyMec 3000 The innovative bi-axial PV tracker Data Sheet Rel. 00 Gen. 2010 Pagina 1 di 10

TECHNICAL DATA Sunnymec 3000 Installed photovoltaic power ( standard efficiency module 12...14 % ) 2,3 to 3,1 Kwp Installed photovoltaic power ( high efficiency module 17 % ) 2,3 to 3,3 Kwp Net photovoltaic area 20 sqm Number of modules ( with standard efficiency module 12...14 % ) 10 to 13 Number of modules( with high efficiency module 17 % ) 10 to 14 Azimuth excursion 270 Zenith distance Precision of axis movement 82 + - 0,5 Azimuth axis speed 30,2 / min Zenith axis speed 22,8 / min Positioning logic Precision of calculating the astronomical position Local control ( optional ) Remote control ( optional ) Wind resistance Anemometer ( optional ) safety speed Base diameter width height Tuning radius Astronomical algorithm 1/100 Interactive display Radio remote ctrl / RS485 Up to 120 Km/h 70 km/h 1400 mm 3600 mm ( with 10 module ) to 6960 (with 13 module) 1650 ( anti-wind pos.) to 2980 ( sunrise-sunset pos.) 2690 mm ( with 10 module ) to 4040 mm (with 13 module) Weight of structure without modules 430 kg Weight of structure with PV modules 570 to 750 kg Attachment points anti-theft Power supply Power consumption Energy consumption 4 Panel locking system 230Vac/50 Hz Max 100 W < 10 Kwh / year Pagina 2 di 10

TECHNICAL DATA Sunnymec 3000 Yearly revision of mechanical and Maintenance electrical parts Totally indipendent PLC, on each Automation tracking system with possible remote control and interconnection 50 months on the part built by Guarantee Meccatronica SHADOWS To avoid having shadows or other elements that cast shadows hanging over the trackers, distance of 15 m in E-W direction and 12 m in N-S direction should be manteined between the tracker axes. With the distances above described, each tracker occupies virtually 180 sqm, with a power density of about 17 Wp/sqm. NOTE: the distance between the trackers can depend on the number of photovoltaic modules fitted on each SunnyMec and latitude. If requested MECCATRONICA can perform a specific calculation, to reduce space and increase the density coefficient Wp /sqm, besides the above values. Pagina 3 di 10

EXAMPLE 1 The above views are for a configuration of 3055 Kwp / 13 modules 235 Kwp / module sizes 1650 x 990 ( optional gas springs are required ) Pagina 4 di 10

EXAMPLE 2 The above views are for a configuration of 2350 Kwp / 10 modules 235 Kwp / module dim. 1650 x 990 Pagina 5 di 10

FOUNDATION SunnyMec 3000 trakers can be installed on concrete footing with the dimension given below: CONCRETE: Exposure class XC2 Aggregates max. dia. 25 mm S4 consistency class Resistance class C25/30 Rck= 300 dan/ sq cm levelling tollerance on the surface: max +- 5 mm/m CORRUGATED STEEL: B450C THREAD BARS: No.4 on square 1028 x 1028 mm M16 CL. 5.8 / L= 250 galvanized or stainless steel use chemichal anchor type T-BOND fisher for fixing HOLE DIAMETER: 18...20 ( size dipends on the type of chemical anchor ) This foooting requires no excavation work: it is only necessary to clean off the ground, remove the vegetation on the surface and levelling the ground. In case of particular terrain, Meccatronica can help the customer with a new footing calculation ( data of terrain to be provided by the client). Pagina 6 di 10

TRANSPORT AND ASSEMBLY SunnyMec 3000 are delivered pre-mounted but the final assembly, along with the necessary machinery and personnel, is requested usually the responsability of the client. If request Meccatronica can assist for final assembly on site using its own personnel. For their transport the SunnyMec 3000 modules can be splitted into only 3 parts: 1. MAIN BODY: base disk with main wheel carriage ( 1400 x 2100 x H 1000 mm ) 2. CENTRAL FRAME ( 2800 x 2100 h 120 mm) 3. PV module support frame ( 1030 x 90/180 x L= 3600...6960 ) All the bolts, nuts, pins necessary for the assembly are supplied with the trackers. During SunnyMec assembly, lifting equipment must be used to place the parts. Said machinery used in the assembly of the tracker will be the client's responsability ( if not otherwise agreed ) Pagina 7 di 10

Tracker assembly requests the following operations ( two persons are needed) : STEP OPERATION TIME Place the MAIN BODY on the foundation footing; 1 Line up the base disk; 15 min Fix the main body using the four bracket suplied with SunnyMec; 2 Place the CENTRAL FRAME on the MAIN BODY : only 2 pins are necessary. 5 min 3 Place the PV module support frame on the CENTRAL FRAME: only 4 pins are necessary. 10 min Total time request: 30 min START UP The SunnyMec start up is very simple. It's only necessary: 1. to set the GPS coordinates of the installation site 2. to set the East end switch position. Normally the start up is made by a Meccatronica Technician, but the operation are explained in the manual suplied with the traker. If the interactive display is not avaiable it will be necessary to use the mobile display supplied as optional. Pagina 8 di 10

MONITORING AND SUPERVISION Pagina 9 di 10

ELECTRICAL DIAGRAM Pagina 10 di 10