Instruction de montage de voûte ISOLHIS petite portée



Similar documents
Instruction de montage de voûte ISOLHIS grande portée PCA 32mm

SUPPORTS DE TABLETTES SUR CABLES OU TIGES INOX CABLE AND ROD SUSPENDED DIPLAY SYSTEMS

Spécifications techniques

SURFOX 304 MIG & TIG 54-D 314 (120V) & 54-D 334 (230V) MARCH R R R K S S

> CABLE 3 MM / 3 MM CABLE COMPONENTS

Ostéotomie tibiale de soustraction externe Closing wedge tibial osteotomy

NÜVO REVO mm 810 x 810 x ( ) No. Description

Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

ColdGuard Bi-PARTING DOOR INSTALLATION INSTRUCTIONS

ref. 6 Young 2G Accès d angle à 2 portes pivotantes / Corner entry enclosure, 2 hinged doors

Repair Parts List. Valor Model 530X NG/LPG Gas Fireplace Heater. Manufactured by. Of British Columbia, Canada

Document Number TD- 002 Reviewed By Technical Director Drafted By. National Technical Commissioner V Immediate

Note concernant votre accord de souscription au service «Trusted Certificate Service» (TCS)

S C R E W S THE ORIGINAL ROBERTSON L ORIGINAL HVAC FASTENER PROGRAM PROGRAMME HVAC

767 Diagnostic System

Installation instructions

Personnalisez votre intérieur avec les revêtements imprimés ALYOS design

Les Produits MURPHCO Ltée

SECTION 7 - REPAIR/REPLACEMENT PROCEDURES

Original instructions Protective tube for Orion1B and Orion2 Orion WET-xxx and Orion WET-Kxxx

Installation Manual. SKU# series (Base Rails) SKU# series (Overhead Racks)

CSS : petits compléments

AN-65AG1 ENGLISH FRANÇAIS DEUTSCH ESPAÑOL

APPLICATION SPECIFICATION

Backup Scanner Module

Re-board Accessories

Lathe Milling Attachment

Lumination TM LED Luminaires Light Bar Retrofit Kit Series

Packaged Terminal Air Conditioner Wall Sleeve Installation

Greenhouse Assembly Instructions

Series Installation Guide Internal AC Outlet Option Kit

HORIZONTAL INSTALLATION

extintores Armoires_ FAEX Cabinets_ Caixas_ EXFAEX

Direct AC Wiring Option Installation Guide

BUILD A TABLETOP LOOM

Sliding and Folding Door Fittings Sliding Door Accessories

CONNECTEURS CONNECTORS. axocoax

Compact I/O End Caps/Terminators

Complete units. Complete underfloor box for one Modul 45 socket and two data connection sockets. Complete service outlets

PANELIZED HOME INSTALLATION GUIDELINE

WATER SERVICE 2

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

Introduction au BIM. ESEB Seyssinet-Pariset Economie de la construction contact@eseb.fr

James M. Pleasants Company

Premier & Deluxe 3-Season Room Sliding Glass Door

Bimetal thermometer Model 52, industrial series

Owner's Manual & Assembly Instructions

L304 LED PUSHBUTTON SWITCH / DISPLAY INDICATOR INDICATEUR LUMINEUX A LED / BOUTON POUSSOIR

PREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS

NEWS FROM SACLAY ATLAS MMM CERN 24/25 JUNE

Floor & Furniture Protectors in Bulk

Décor / Colour. POUR VERRE DE 10 et 12 mm - FOR 3/8 & 1/2 GLASS. - Bec de cane - Peut être livré avec une béquille TC

SSG PRODUCTS FOR SHIPS AND OFFSHORE

Installation Instructions

Wideband Optical Splitters FOS Series

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Calcul parallèle avec R

(51) Int Cl.: B29C 41/20 ( ) F21S 4/00 ( ) H05K 3/28 ( )

1/5 PIPER J-3 CUB. Before commencing assembly,please read these instructions thoroughly. Wing Span:84. 0 in / 2130 mm

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

Saferand easierinstallation

Capteur température et humidité pour HVAC

Installation Instructions

SERVICE INSTRUCTIONS REPLACEMENT INSTRUCTIONS FOR 828XXXX, 830XXXX, 833XXXX, 834XXXX, 836XXXX SERIES MODEL 8300 AND SUNCHASER AWNINGS

PITCHED ROOF STRUCTURES

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Installation Instructions

MGB Chrome Bumper Conversion

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Electrical/Electronics

16-Port Gigabit Green Switch (TEG-S16Dg) 24-Port Gigabit Green Switch (TEG-S24Dg)

TABLECLOTHS TEMPLATES

INSTALLATION INSTRUCTIONS COMPETITION SERIES COILOVER SUSPENSION SYSTEM 03+ Scion xb

Oceanscience Cable Chimp II Cableway ROV System User Guide and Warranty

Light, robust, versatile

FINAL DRAFT INTERNATIONAL STANDARD

TARIFF CODE and updates standard

Mini USB and USB 2.0-IP67 Connector System

Life Sciences. Volume 5 August Issue date: August 7, 2008

Hürriyet Mah. Dr. Cemil Bengü Cad. No.27/A Çağlayan / Istanbul

Installation instruction do88 Intercooler for Volvo S40 / V50 / C30

AD511 Active Iridium Antenna User Manual Mar 12 V4.0

Installation, operation and maintenance manual TX 35A

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

Machine Screws, Dowel Pins and Hardware

site et appel d'offres

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL

Tubular connection elements

Clad Direct Glaze Window Installation Instructions

LK Wallbox UNI Push. Assembly. Only intended for LK PE-X Universal Pipe X.

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

1.8 CRANKSHAFT OIL SEALS

REBAR SPLICING SYSTEM. systèmes constructifs

March 14, Installation of Bay, Bow and Garden Windows

Installation Detailed installation instructions are provided which should be strictly followed.

Transcription:

Instruction de montage de voûte ISOLHIS petite portée Mounting Instructions for continuous rooflight ISOLHIS with a little width Outillage à prévoir Tools to be provided Visseuse 600 W 1600 Tr/mn Screwing machine 600W 1600T/mn + Douille de 8 et 10 8mm diameter socket Ou Or Clé à pipe de 8 et 10 8mm diameter box spanner Embouts 8 et 10 8 and 10 nozzles Fourniture SODILIGHT Provided by SODILIGHT Tympan (pré-monté en usine) Tympanum (pre-mounted in factory) 1 10 Vis auto-perçante 6.3x25 Self-tapping screw 6.3x25 2 13 Rives pour PCA 16 mm Edge sections for PCA 16 mm Vis TC 5.5x38 (16 mm) TC screw 5.5x38 (16 mm) Arceau A60 Arch A60 3 14 Vis TH à embase 6.3x51 Inox A2 TH screw 6.3x51 Inox A2 Ép. Renfort 1200J U de 20x20x20x2 4 15 1200J Bars U-profil 20x20x20x2 Plaque de PCA (Ép.16 mm) Polycarbonate sheet (Thickness 16 mm) 5 17 Joint de pareclose Seal for holding frame Vis TH 6.5x19 Inox A2 + rondelle étanche TH screw for curb 6.5x19 stainless steel + watertight washer 7 Couvre-joint FT Seal cover FT Couvre-joint de tympan Tympanum Seal cover Document n 243630-03-13 Page 1

Montage Assembly VÉRIFIER LES DIMENSIONS, L ÉQUERRAGE ET LE PARALLÉLISME DE LA COSTIÈRE CHECK DIMENSIONS, SQUARE ANGLES AND PARALLELISM OF THE CURB Costière Curb Flanc de costière tympan Tympanum side of curb Flanc de costière longpan Longside of curb FIXATION RIVE SUR COSTIÈRE FASTENING OF EDGE SECTIONS ON CURB 1 Positionnement de la rive Positionning of edge section Obturateur Closing Rive intermédiaire Intermediary edge section Rive de fin Final edge section Rive de départ Starting edge section Obturateur Closing Document n 243630-03-13 Page 2

2 Fixation de la rive Fastening of edge section Vis auto-perçantes 6.3x25 (10) tous les 300mm Self-tapping screws 6.3x25 (10) every 300mm Flanc de costière tympan Tympanum curb side 60 mm 46 mm 300 mm 80 mm Flanc de costière longpan Longside of curb 46 mm FIXATION TYMPAN FASTENING OF TYMPANUM Arceau de tympan (3) Tympanum arch (3) Vis auto-perçantes 6.3x25 (10) Self-tapping screws 6.3x25 (10) Arceau de tympan (3) Tympanum arch (3) Pré-perçages A à centrer avec ceux de la Pre-percing A to adapt to those of the edge section (2) Pré-perçage B à centrer avec la rainure de l arceau (3) Pre-percing B to adapt with groove of arch (3) Document n 243630-03-13 Page 3

Tympan (1) Tympanum (1) Aligner l arrière du tympan avec l intérieur du flanc de costière tympan Lign up back side of tympanum with interior side of long side of the curb Vis auto-perçantes 6.3x25 (10) tous les 300 mm Self-tapping screws 6.3x25 (10) every 300 mm FIXATION ARCEAUX FASTENING OF ARCHES Entraxe Pace Tympan (1) Tympanum (1) Arceau intermédiaire (3) Intermediray arch (3) De même que pour la fixation tympan,vis auto-perçantes 6.3x25 (10) en face des pré-perçages A Same as fastening of tympanum, self-tapping screws 6.3x25 (10) in front of pre-percing A Document n 243630-03-13 Page 4

FIXATION RENFORTS 1200J FASTENING OF 1200J BARS Vis TH 6.5x19 Inox A2 + rondelle étanche (17) Stainless steel screw 6.5x19 (17) + watertight washer Renfort 1200J (U de 20x20x20x2) (4) 1200J Bars (U-profil 20x20x20x2) (4) MISE EN PLACE DES PLAQUES DE PCA INSTALLATION OF PCA SHEETS FACE TRAITÉE ANTI-UV VERS L EXTÉRIEUR EXTERIOR SIDE TREATED AGAINST UV RAYS Document n 243630-03-13 Page 5

FIXATION DES COUVRE-JOINTS FASTENING OF SEAL COVERS 1 Couvre-joint Seal cover Couvre-joint (7) Seal cover (7) Vis TH à embase 6.3x51 Inox A2 TH screw 6.3x51 Inox A2 LE COUVRE-JOINT (7) DOIT ÊTRE IMPERATIVEMENT TENDU AVANT D ÊTRE FIXÉ À L ARCEAU (3) SEAL COVER (7) HAS TO BE TIGHTENED BEFORE BEEING FASTENED TO THE ARCH (3) Couvre-joint (7) Seal cover (7) Vis TC 5.5x38 (13) au niveau des pré-perçages du couvre-joint (7) TC screw 5.5x38 (13) on level of the pre-piercings for the seal cover (7) Document n 243630-03-13 Page 6

2 Couvre-joint de tympan Seal cover of tympanum LE COUVRE-JOINT (7) DOIT ÊTRE IMPERATIVEMENT TENDU AVANT D ÊTRE FIXÉ À L ARCEAU (3) SEAL COVER (7) HAS TO BE TIGHTENED BEFORE BEEING FASTENED TO THE ARCH (3) Couvre-joint de tympan(7) Seal cover of tympanum (7) Vis TC 5.5x38 (13) au niveau des pré-perçages du couvre-joint (7) TC screw 5.5x38 (13) on level of the pre-piercings for the seal cover (7) POSE DES JOINTS DE PARECLOSE INSTALLATION OF SEALS Commencer à insérer le joint à chaque extrémité puis le faire glisser vers le centre Begin inserting seal on every edge before sliding it towards the middle Couvre-joint (7) Seal cover (7) Joint de pareclose (15) à venir glisser entre la et la plaque de PCA (5) Seal of covering frame (15) to be slided beetwen the edge section (2) and the LE MONTAGE DE LA VOÛTE EST TERMINÉ ASSEMBLING OF THE CONTINUOUS ROOFLIGHT IS DONE Document n 243630-03-13 Page 7