Ground Truthing Infiltration & Inflow using Trenchwater Piezometers, Electro Scan and CCTV Presented by: Gordon Henrich, D.M. Robichaud Randy Kowal, D. M. Robichaud Nov. 30, 2015 Robichaud
About D. M. Robichaud, Oshawa, Ontario 2
Non-Destructive Testing of Wastewater Pipe Disruptive technologies don t conquer their markets until they redefine their marketplace. When that happens, mastery of that new paradigm redefines industry leadership overnight. 3 Laura Shenkar, Principal, The Artemis Project
About Electro Scan Inc. Patented 1995 Best 2014 UK Project With Severn Trent Best Innovative Technology, WEF
Assessing Sewer Pipe with Electricity First consistent and repeatable test that locates all pathways between the inside of a non-metallic pipe that estimates leak size and defect flow in L/S. 5
Industry Standard ASTM International F2550-13 Originally approved in 2006, ASTM F2550 was recently modified to expand its use to include testing and certification of pipe repairs, renewal, and new construction. The revised standard was approved October 1, 6 2013, by unanimous vote of Committee F36, for renewal for a five-year extension.
Focussed Electrode Leak Locating (FELL) A B C D 7
8
9
10
11
12
13
14
Repeatability: US EPA Independent Testing 2011 Same Equipment and Same Field Crew with Testing of 60-days (2 months) Apart. 15
Repeatability: Miami-Dade County, 2014-2015 Different Equipment, Software Versions, Field Crew with Testing of 142-days (4 1/2 months) Apart 16
Comparison of Electro Scan Readings to PACP CCTV 163 (CCTV) 163 (ES) Estimated Infiltration Flow: 0.2 GPM CCTV Callout: Tap Break In 161 (CCTV) 161 (ES) Estimated Infiltration Flow: 1.65 GPM CCTV Callout: Hole in Pipe, Soil Visible 17
View Results on Cloud Within Minutes Office Upload if WIFI is Not Available in the Field Scan Detail Report Project Scans By Date Fire Wall Password, Protected Severn Trent Account Authorized Electro Scan Contractor Electro Scan Summary From SP31380501 To SP31380601 18
Location & Amount of Defect Flow Defect Counts Estimated Total Defect Flows. Scan Graph for Visual Reference* 100 meters of scanning may provide 15,000 to 20,000 unique data points. Tabular Data Available for Export 19
Electro Scan Applications Identify and measure all sources of infiltration from cracks, bad joints, and defective service connections, Rank & prioritize sewer mains and laterals that should be repaired, relined, or renewed, Integrate with hydraulic modeling programs to re-calibrate model assumptions based on its estimated gallons per minute (GPM) of flow from defects, Certify point repairs, relining, and new construction (i.e. citing ASTM F2550 as part of any published work specification) to ensure that projects performed by third-party contractors are delivered without defects or leaks, prior to Acceptance. 20
Ground Truthing: (verb) the act of collecting ground truth Ground truth is a term used in various fields to refer to information provided by direct observation as opposed to information provided by inference. (Wikipedia) 21
About Portsmouth Sewershed Inflow and Infiltration Reduction Project Kingston: 485 km sewer mains 31 pumping stations 3 WWTP 22
200mm Mainline Defects: 3055-010 - 3022-020 Each Joint in AC pipe shows up Good data to backup Testing and Sealing of Joints Recommendation 23
200mm Mainline Defects: 3055-010 - 3022-020 Excellent Correlation between ES and CCTV Assessment 24
Utilities Kingston: Defect Flow Report Less than 10% of pipes account for 50% of total infiltration and 161 liters per second Single Main Represents 784 or 15% of Total Defect Count ( Extremely deterioriated AC pipe or a Metallic pipe) 25
Utilities Kingston: Defects by Pipe Type Appears that clay pipe may be under-performing other pipe materials. Appears that PVC may be out-performing other pipe materials. 26
Next Steps: Electro Scan to CCTV Observations Example 27
Portsmouth Sewershed Manhole Piezometer Trenchwater Monitoring 28
Trenchwater Piezometer results 29
Trenchwater Piezometer results 30
Analysis to be completed 2016 very promising results verifying by ground truthing of Electro Scan leak quantifications 31
Unused Capabilities: Lateral Scans Android App 32
Unused Capabilities: Large Diameter Scans If a pipe leaks electricity it will leak water. 33
Thank You & Contacts D.M. Robichaud Associates Ltd. Randy Kowal VP, Engineering Technologist 627 Wentworth St. East Oshawa, ON L1H 3V8 Cell: 905-767-0029 Office: 905-433-1261 randy@nodig.ca Gordon Henrich Technical Consultant Cell: 226-923-0602 gord@nodig.ca 34
Most Frequent Questions Doesn t the conductivity of the soil have a major effect on the signal? Does the soil structure affect the electric circuit? Ie. High plastic clay vs. river gravel? Does Electro Scan work with high ground water? What happens if sewer lines have segments of ductile iron? Would tracer wire installed above sewer line, or around surrounding utilities, interfere by skewing test results? How does varying total dissolved solids (TDS) in the water within the pipe affect results? 35