Ground Truthing Infiltration & Inflow



Similar documents
Township of Enniskillen. Asset Management Plan

SEWER CLEANING, INSPECTION AND ASSESSMENT

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

Monterey Regional Water Pollution Control Agency. Sewer System Management Plan

Dry Weather Flow from Footing Drains and Service Connections

Condition Assessment of Underground Pipes April 2015 With excerpts from: Condition Assessment of Wastewater Collection Systems, EPA/600/R-09/049

Work Practice: Wastewater Collection System Maintenance Plan Potential Safety Hazards

Quantifying Inflow and Infiltration via Dyed Water Flooding

PROVIDING THE SAFE CHOICE FOR UNDERGROUND PIPE RENEWAL, INTEGRITY MANAGEMENT AND ASSET RELIABILITY

INDEX. Sec. No. Items Page Nos.

MIAMI-DADE LATERAL PILOT PROGRAM. James T. Cowgill, P.E. Rodney J. Lovett Franklin Torrealba, P.E.

CCTV INSPECTION OF SEWER LINES. A. Section Sanitary Gravity Sewer Lines. B. Section Sanitary Gravity Sewer Line Testing

Greater Dublin Strategic Drainage Study Regional Drainage Policies - Volume 2 New Development

Phased Assessment Strategy for Sewers

STANDARD SPECIFICATIONS SECTION SEWER MAIN AND LATERAL CONNECTION SEALING BY CHEMICAL GROUT

Utilizing Remaining Useful Life for Asset Management of Critical Wastewater Assets

812-3 LIMITATIONS: b. No fire hydrant shall be obstructed or used when there is a fire in the area.

Sanitary Sewer Smoke Testing

A Systematic Approach to Reduce Infiltration and Inflow (I&I) and Sanitary Sewer Overflows (SSO) PETE GORHAM, P.E. MIKE LYNN FEBRUARY 19, 2015

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

Policy Guidance Notes and Requirements

Bridges & Culverts Condition by Quantity

REVIEW OF TRENCHLESS TECHNIQUES FOR THE REHABILITATION OF SEWERS. Gerhard (Gerry) P. Muenchmeyer, P.E. Muenchmeyer Associates, LLC

Dan Ott Managing Engineer Collection System Johnson County Wastewater, KS and Rick Nelson CH2M HILL

Lansdowne Stormwater UPDATE

Mainline Pipe Rehabilitation Using Cured-in-Place Pipe (CIPP) & Folded Pipe Technology

Info What? Using InfoMaster to Develop a Rehabilitation and Replacement Plan

FY08 SEWER POINT REPAIRS BID TABULATION

White Paper I C G. How to Reduce I&I and Prevent Structural Damage with Intelligent Use of Chemical Grout. A Infiltration Control Grouting Association

Section SEWER PIPE INSTALLATION AND TESTING

City of Largo Environmental Services Department Environmental Control Program th Avenue North Clearwater, FL Phone: (727)

Before H 2 Town of South Windsor, CT Evaluates Large Diameter Concrete Pipe

Force Main Condition Assessment: New Technologies & Case Studies

PRODUCT CATALOGUE. for. SMARTPHONE / WEBSITE / DIGITAL EDITION / BOOK / ipad / GPS

Corporate Report. Report from Transportation and Environmental Services, Environmental Services

Kansas City s Overflow Control Program

Special Specification 7021 Water Main and Sewer Line Replacements

Sewer and Stormwater Back-ups Policy Adopted by Council October 4, 2010

SECTION 5: SANITARY SEWER SYSTEM DESIGN

Water Loss and Leak Detection. Gary Armentrout, Project Associate Environmental Finance Center Wichita State University

Affordable Asset Management Workshop Making Use of the Data You Have An Owners Perspective

Building over or close to a public sewer

Oakland Macomb Interceptor Drain Rehabilitation State Revolving Fund Project Plan Overview. Public Meeting June 10, 2009

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

Beechmont Park Project

UNDERGROUND INFRASTRUCTURE SPECIALISTS TABLE OF CONTENTS

City of Mill Valley Sewer Capital Improvement Plan

SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER

SANITARY SEWER SPECIFICATIONS

Wauwatosa Lateral Rehabilitation Pilot Project. Prepared for City of Wauwatosa Wauwatosa, WI January 18, 2013

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

Using Frequent Sewer Inspection to Prioritize Asset Management. May 1, John Schroeder, P.E., BCEE Drew Richards, EI Tim Fallara, P.E.

ATTACHMENT 2: SPECIFICATION FOR SEWER CCTV VIDEO INSPECTION

Repairs Made With Under Pressure Installations Can Offer Reduced Risks And Expenses

Town of Essex NE Lagoon. Service Area. Essex Plant. Service Area. Pumping Station No. 4. Wastewater Pumped To NE Lagoons (Treatment Plant No.

Sewer Rehabilitation Design Requirements

Using GIS to Track and Prioritize Your Assets

1. General General Requirements Gravity Sanitary Sewer Testing Requirements...3

Specifications for Residential Property Owners Connection to New Public Sewer

VILLAGE OF GRANVILLE SEWER BACK-UP and WATER LEAK POLICIES

SPR PE Steel Reinforced Liner

Sewer Water Pipeline Replacement with CERTA LOK RESTRAINED JOINT PVC PIPE

Extreme Wet Weather in Brookfield. How to Keep Your Basement Dry During Heavy Rains and Floods

City of Regina Standard Construction Specification SECTION 1320 SEWERMAIN TESTING

SAWS SSO Reduction Program

Collection Systems Technology Fact Sheet Sewers, Conventional Gravity

MANUFACTURER'S CERTIFICATION SCHEDULE 40 PVC PIPE And SCHEDULE 80 PVC PIPE

Greater Ouachita Water Company. April 2015 Monthly Operations & Maintenance Report

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

ecmar SECTION INSTRUCTIONS: Sanitary Sewer Collection Systems

SANITARY GRAVITY SEWER LINE TESTING. B. Section CCTV Inspection of Gravity Sewer Lines

Master Planning and Hydraulic Modeling

SANITARY SEWER SYSTEM ASSESSMENT

See Appendix A for additional information, or contact ASTM directly.

ZIONSVILLE WASTEWATER DEPARTMENT 10-YEAR SEWER REHABILITATION REPORT

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

Inspecting to a higher standard.

CITY OF BEVERLY RULES AND REGULATIONS - SEWER SYSTEM TESTING. General

WEAT Collections Conference January 22, 2014 NASSCO PACP/MACP/LACP- The Trainer s Perspective. Gerald Boman NASSCO PACP/MACP/LACP Certified Trainer

ATTACHMENT 3: SPECIFICATION FOR SEWER CLEANING

1.3.2 Method of construction and restoration of existing water service connections. This shall include:

EPA Region 4 Introduction to Conducting Evaluations of Municipal Wastewater Collection System Management, Operation, and Maintenance Programs

SCOPE OF WORK SEWER LINE CLEANING FOR CITY OF THE OF HUNTINGTON BEACH PROPERTY

Sewer Line Rehabilitation

SECTION CLEANING AND CLOSED CIRCUIT TELEVISION (CCTV) INSPECTION OF SEWER PIPE

City of Dallas Wastewater Collection System: TCEQ Sanitary Sewer Outreach Agreement City Council Briefing January 17, 2007

Earthquake damage in wastewater systems and postearthquake repair methods; limitation and practice

Transcription:

Ground Truthing Infiltration & Inflow using Trenchwater Piezometers, Electro Scan and CCTV Presented by: Gordon Henrich, D.M. Robichaud Randy Kowal, D. M. Robichaud Nov. 30, 2015 Robichaud

About D. M. Robichaud, Oshawa, Ontario 2

Non-Destructive Testing of Wastewater Pipe Disruptive technologies don t conquer their markets until they redefine their marketplace. When that happens, mastery of that new paradigm redefines industry leadership overnight. 3 Laura Shenkar, Principal, The Artemis Project

About Electro Scan Inc. Patented 1995 Best 2014 UK Project With Severn Trent Best Innovative Technology, WEF

Assessing Sewer Pipe with Electricity First consistent and repeatable test that locates all pathways between the inside of a non-metallic pipe that estimates leak size and defect flow in L/S. 5

Industry Standard ASTM International F2550-13 Originally approved in 2006, ASTM F2550 was recently modified to expand its use to include testing and certification of pipe repairs, renewal, and new construction. The revised standard was approved October 1, 6 2013, by unanimous vote of Committee F36, for renewal for a five-year extension.

Focussed Electrode Leak Locating (FELL) A B C D 7

8

9

10

11

12

13

14

Repeatability: US EPA Independent Testing 2011 Same Equipment and Same Field Crew with Testing of 60-days (2 months) Apart. 15

Repeatability: Miami-Dade County, 2014-2015 Different Equipment, Software Versions, Field Crew with Testing of 142-days (4 1/2 months) Apart 16

Comparison of Electro Scan Readings to PACP CCTV 163 (CCTV) 163 (ES) Estimated Infiltration Flow: 0.2 GPM CCTV Callout: Tap Break In 161 (CCTV) 161 (ES) Estimated Infiltration Flow: 1.65 GPM CCTV Callout: Hole in Pipe, Soil Visible 17

View Results on Cloud Within Minutes Office Upload if WIFI is Not Available in the Field Scan Detail Report Project Scans By Date Fire Wall Password, Protected Severn Trent Account Authorized Electro Scan Contractor Electro Scan Summary From SP31380501 To SP31380601 18

Location & Amount of Defect Flow Defect Counts Estimated Total Defect Flows. Scan Graph for Visual Reference* 100 meters of scanning may provide 15,000 to 20,000 unique data points. Tabular Data Available for Export 19

Electro Scan Applications Identify and measure all sources of infiltration from cracks, bad joints, and defective service connections, Rank & prioritize sewer mains and laterals that should be repaired, relined, or renewed, Integrate with hydraulic modeling programs to re-calibrate model assumptions based on its estimated gallons per minute (GPM) of flow from defects, Certify point repairs, relining, and new construction (i.e. citing ASTM F2550 as part of any published work specification) to ensure that projects performed by third-party contractors are delivered without defects or leaks, prior to Acceptance. 20

Ground Truthing: (verb) the act of collecting ground truth Ground truth is a term used in various fields to refer to information provided by direct observation as opposed to information provided by inference. (Wikipedia) 21

About Portsmouth Sewershed Inflow and Infiltration Reduction Project Kingston: 485 km sewer mains 31 pumping stations 3 WWTP 22

200mm Mainline Defects: 3055-010 - 3022-020 Each Joint in AC pipe shows up Good data to backup Testing and Sealing of Joints Recommendation 23

200mm Mainline Defects: 3055-010 - 3022-020 Excellent Correlation between ES and CCTV Assessment 24

Utilities Kingston: Defect Flow Report Less than 10% of pipes account for 50% of total infiltration and 161 liters per second Single Main Represents 784 or 15% of Total Defect Count ( Extremely deterioriated AC pipe or a Metallic pipe) 25

Utilities Kingston: Defects by Pipe Type Appears that clay pipe may be under-performing other pipe materials. Appears that PVC may be out-performing other pipe materials. 26

Next Steps: Electro Scan to CCTV Observations Example 27

Portsmouth Sewershed Manhole Piezometer Trenchwater Monitoring 28

Trenchwater Piezometer results 29

Trenchwater Piezometer results 30

Analysis to be completed 2016 very promising results verifying by ground truthing of Electro Scan leak quantifications 31

Unused Capabilities: Lateral Scans Android App 32

Unused Capabilities: Large Diameter Scans If a pipe leaks electricity it will leak water. 33

Thank You & Contacts D.M. Robichaud Associates Ltd. Randy Kowal VP, Engineering Technologist 627 Wentworth St. East Oshawa, ON L1H 3V8 Cell: 905-767-0029 Office: 905-433-1261 randy@nodig.ca Gordon Henrich Technical Consultant Cell: 226-923-0602 gord@nodig.ca 34

Most Frequent Questions Doesn t the conductivity of the soil have a major effect on the signal? Does the soil structure affect the electric circuit? Ie. High plastic clay vs. river gravel? Does Electro Scan work with high ground water? What happens if sewer lines have segments of ductile iron? Would tracer wire installed above sewer line, or around surrounding utilities, interfere by skewing test results? How does varying total dissolved solids (TDS) in the water within the pipe affect results? 35