22 12 00 FACILITY POTABLE WATER STORAGE TANKS



Similar documents
15430 SAFETY SHOWERS AND EYEWASHES

GENERAL PLUMBING REQUIREMENTS

What to Expect From the Examination. How to Study the Plumbing Codes

GENERAL PLUMBING REQUIREMENTS

DIVISION 22 PLUMBING PLUMBING EQUIPMENT Domestic Water Heaters

SECTION COMMERCIAL PLUMBING FIXTURES

Element D Services Plumbing

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PLUMBING SPECIALTIES

Dominic i Barbato Dpt. Of Building and Safety (818) domenico.barbato@lacity.org

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

Georgia State Amendments to the International Plumbing Code

EMERGENCY PLUMBING FIXTURES

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

FIRING RANGE PHASE 1 DESIGN

Emergency Showers and Eyewashes Mike Adkins Wednesday, October 31, 10:00-11:1511:15 a.m.

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa Phone: Fax:

DIVISION 22 PLUMBING PLUMBING EQUIPMENT Domestic Water Heaters

Amendments to the 2012 International Plumbing Code

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

When Should Examination Preparation Begin?

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Plumbing Apprenticeship Program Curriculum

A. Product Certificates: Submit certificates of performance testing specified in "Source Quality Control" Article.

Arapahoe County Residential Water Heater Installation and Inspection Guide

CITY of LOS ANGELES DEPARTMENT of BUILDING and SAFETY

Land Use and Environmental Service Agency (Code Enforcement) NC Plumbing Code. Table of Contents

Design Requirements for Eyewash and Safety Shower Units APPLICATION: Detailed Installation, Operation and Design. Eyewash Stations.

Backflow Bulletin #1

City of Elk River BASEMENT Office Use Only

PLUMBING ROUGH IN INSPECTION

PLAN REVIEW AND APPROVAL FOR FOOD ESTABLISHMENTS PLUMBING REQUIREMENTS FOR FOOD ESTABLISHMENT PREMISES

Residential Plumbing BCN 1058

CHAPTER 2: The Plumbing System

Plumbing Code Sections For Commercial Food Facilities

Section 4 EMERGENCY EYEWASH AND SAFETY SHOWER EQUIPMENT

WELCOME INTERNATIONAL RESIDENTIAL CODE 2009 EDITION PLUMBING SECTION

B. Shop Drawings: Diagram power, signal, and control wiring.

Teacher Assessment Blueprint. Plumbing. Test Code: 5175 / Version: 01. Copyright 2010 NOCTI. All Rights Reserved.

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

One of the fundamental design elements that every

CHAPTER 26 PLUMBING CODE

COMPLETE FACILITIES SUPPLY YOUR COMPLETE SOURCE FOR FACILITY MAINTENANCE SUPPLIES Virginia Meadows Drive Manassas, Virginia USA

Does Wall Township require an inspection by the building department on resale of a home?

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

WINTERIZING YOUR HOME PLUMBING AT BLUE RIDGE SHORES

CHAPTER 9 VENTS. copper drainage tube Type DWV, Schedule 40 plastic piping, or borosilicate glass.

Brian Coppock, Regional Compliance Officer. Office of Statewide Health Planning and Development Facilities Development Division

Carriers, Fixtures & Piping

2006 Codes. Please verify the following before calling for inspection

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition.

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

Most agencies think about cleaning because of debris in the line.

Plumbing Code in Commercial Kitchens

INTERNATIONAL RESIDENTIAL PLUMBING CODE

Emergency Showers and Eyewash Stations

SIZING OF WATER PIPING SYSTEM

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

CONSTRUCTION CHECKLIST Residential Plumbing Rough-In September 2004

New or Remodeled Food Service Establishment Checklist**

PLUMBING & CROSS-CONNECTION CONTROL

ANSI / ISEA Z Compliance Checklist

Yale University Design Standards

6. Principles of effective plumbing systems

WHITE PLAINS PLUMBING CODE PART 1. GENERAL REQUIREMENTS

THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS: Section 1. Article V of Chapter XII of the Los Angeles Municipal Code is added to read:

Introduction. Kitchens

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Emergency Eyewash and Drench Shower Program

To many people, a home s plumbing system is perceived as being extremely

Building Condition Assessment Report

ADDENDUM NO. 1. DATE: February 10, 2015 INVITATION FOR BID: IFB K Commerce Road Renovations Project DATED: February 9, 2015

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

Building Condition Assessment Report

Water Damage Prevention Risk Management Guidebook

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Oregon Plumbing Rule and Law RV

NAVIEN AMERICA INC FITCH AVENUE

Montgomery County Health Department Mobile Food Guidelines. Definitions

TOWN OF DAVIE BUSINESS TAX RECEIPT 6591 ORANGE DRIVE DAVIE, FLORIDA PHONE: FAX:

INSPECTION CHECKLIST Residential Plumbing Rough In April 2011 Mercer Island Mill Creek Sammamish Snohomish County Snoqualmie Woodinville

PLAN CHECK CORRECTION SHEET FOR PLUMBING SYSTEMS 2014 LAPC

2012 British Columbia Plumbing Code Update

FAQ and Device/Usage Chart. What Is a Cross-Connection? What Is Backflow Prevention? What Is Backflow?

Top 10+ Mistakes of DWV plumbing design

Lot Number. City. Architect Name SUBCONTRACTORS - COMPLETE AND ATTACH LIST ON PAGE 4

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities

Job Ready Assessment Blueprint. Plumbing. Test Code: 3061 / Version: 01

Exhibit B. Property Acquisition and Disposition Division Residential Design & Performance Standards

Transcription:

DIVISION 22 PLUMBING 22 11 16 DOMESTIC WATER PIPING 22 11 19 DOMESTIC WATER PIPING SPECIALTIES 1. To facilitate landscape and other maintenance operations, exterior hose bibs shall be provided at 50 foot intervals along building perimeters, including near principal building entrances and exits. Each building face shall have at least one hose bib. 1. All hose bibs shall be of the non-freeze, recessed lockable wall box type, and shall be mounted flush to the wall. 22 11 23 DOMESTIC WATER PUMPS 22 11 23.13 DOMESTIC WATER PACKAGED BOOSTER PUMPS 22 12 00 FACILITY POTABLE WATER STORAGE TANKS 22 13 16 SANITARY WASTE AND VENT PIPING 1. All new building sanitary lines shall go to a manhole. PART III DIVISION 22 PAGE 1 RUTGERS DESIGN STANDARDS MANUAL NOVEMBER 2015

2. For design purposes, all floor drains in spaces other than mechanical equipment rooms shall be considered infrequent use in accordance with the National Standard Plumbing Code. 3. All floor drains in mechanical rooms and other locations shall be connected to the sanitary sewer system. 1. Hubless cast iron pipe is acceptable above grade. Do not use hubless cast iron pipe underground or under floor slabs. 22 13 19 SANITARY WASTE PIPING SPECIALTIES 22 13 29 SANITARY SEWERAGE PUMPS 22 14 13 FACILITY STORM DRAINAGE PIPING 1. Provide at least 2 roof drains per section of roof. See Uniform Construction Code for additional requirements. 22 14 29 SUMP PUMPS PART III DIVISION 22 PAGE 2 RUTGERS DESIGN STANDARDS MANUAL NOVEMBER 2015

22 15 13 GENERAL-SERVICES COMPRESSED AIR PIPING 22 15 16 GENERAL SERVICE COMPRESSED AIR VALVES 22 15 19 GENERAL SERVICE PACKAGED AIR COMPRESSORS AND RECEIVERS 22 31 00 DOMESTIC WATER SOFTENERS 22 32 00 DOMESTIC WATER FILTRATION EQUIPMENT 22 33 00 ELECTRIC DOMESTIC WATER HEATERS 1. Electric water heaters are permitted as an alternative to direct or indirect-fired hot water heaters to serve local low flow hot water requirements. 1. Electric hot water heaters shall be as manufactured by A.O. Smith or approved equal. PART III DIVISION 22 PAGE 3 RUTGERS DESIGN STANDARDS MANUAL NOVEMBER 2015

22 34 00 FUEL-FIRED DOMESTIC WATER HEATERS 1. Oil fired water heaters may be required where significant hot water requirements must be met and gas service or indirect water heating is not available. Oil fired water heaters shall be used only with Rutger's approval. 1. Fuel burning equipment must be registered with REHS by the A/E (care of the project team leader) during design. Fuel burning equipment with a maximum rated fuel input of 1,000,000 BTU/hr or greater will require an air permit, prior to installation. REHS will submit all air permit applications. The A/E shall be responsible for preparation and follow-up correspondence with REHS and\or the DEP for all permitting required for fuel burning equipment. The A/E is responsible to supply equipment information to REHS with adequate lead-time to obtain permit (180 days prior to intended installation date.) This information includes, but is not limited to: a description of the fuel burning equipment, manufacturer name, model number and fuel type used. All documentation demonstrating conformance with Factory Mutual requirements must be submitted to FM for review\approval as required. 1. Oil fired water heater manufacturers shall be as approved by Rutgers. 22 35 00 DOMESTIC WATER HEAT EXCHANGERS 1. Domestic water generally should be heated with high temperature hot water (HTHW) when central heating system is available. 2. HTHW system operating parameters vary depending upon the system under consideration. 3. For the Busch and Livingston campuses, HTHW is provided from the Busch Central heating plant. HTHW leaves the plant at approximately 365 degrees F. and a pressure between 180 psi and PART III DIVISION 22 PAGE 4 RUTGERS DESIGN STANDARDS MANUAL NOVEMBER 2015

200 psi. Depending on where the building is located on the distribution system, the temperature will vary between 335 degrees F. and 360 degrees F. The pressure will vary between 160 psi and 200 psi. Heat exchangers shall be designed for a 100 degree temperature differential. More specific design parameters can be provided by Rutgers Utilities Department based upon actual building location. 4. For the College Avenue campuses, HTHW is provided from the College Avenue Central heating plant for a portion of the campus. HTHW leaves the plant at approximately 315 degrees F. and a pressure of approximately 110 psi. Heat exchangers shall be designed for a 75 degree F. temperature differential. Depending on where the building is located on the distribution system, temperatures and pressure will vary. More specific design parameters can be provided by Rutgers Utility Department based upon actual building location. 1. Refer to Section 23 05 23 General-Duty Valves for HVAC and Section 23 21 13 Hydronic Piping for related information. 2. All heat exchangers shall comply with ASME Boiler and Pressure Vessel Code and shall be stamped with appropriate code symbols. 3. Bolted flange connections shall be provided on both the primary side and secondary side of all heat exchangers. 4. HTHW heat exchangers shall be shell and tube type with HTHW in tubes. Tubes shall be 90-10 copper-nickel. Heads shall be forged steel. HTHW heat exchangers shall be as manufactured by Cemline, Yula, Bell & Gossett or Armstrong. Domestic water heat exchangers must conform with requirements of the National Standard Plumbing Code (i.e. double wall construction, etc.). It is the responsibility of the A/E to be aware of and comply with all Code requirements. These Standards are not intended to re-state requirements set forth in applicable Codes. PART III DIVISION 22 PAGE 5 RUTGERS DESIGN STANDARDS MANUAL NOVEMBER 2015

22 40 00 PLUMBING FIXTURES 1. The A/E shall obtain the Standard Plumbing Fixture List from University Housing for the respective Housing project. Provide hose bibb in dormitory common toilet rooms where required by Housing. 2. Automatic hands free (automatic flushing and turn on/off) fixtures are preferred for toilet areas and are required for all ADA water closets, urinals, sinks and hand dryers. All hands free fixtures shall be equipped with manual override. Hard-wired automatic fixtures are preferred to battery operated. Bathroom and kitchen fixtures for projects not under the jurisdiction of University Housing, Dining Services or Athletics shall be as follows unless otherwise necessary to suit project specific requirements: a. Toilets: Wall-hung, vitreous china, single flush, piston, or heavy duty diaphragm type, maximum 1.28 GPF, as manufactured by Toto, Kohler, or American Standard. b. Urinals: Wall-hung, vitreous china, piston or heavy duty diaphragm type, maximum.125 GPF as manufactured by Toto, Kohler or American Standard. c. Lavatories: Wall-hung or under-mount, vitreous china, maximum 0.5 GPM as manufactured by Toto, Kohler, or American Standard. Automatic faucets shall be equipped with above deck mixing valve where required to ensure access to serviceable faucet components. Pre-molded Corian type lav/countertops for multiple lavatory applications shall be permitted subject to Rutgers approval. d. Kitchen Sinks (Office Kitchen Areas): Drop-in, self-rimming, single compartment, stainless steel, as manufactured by PART III DIVISION 22 PAGE 6 RUTGERS DESIGN STANDARDS MANUAL NOVEMBER 2015

American Standard, Just, or Kohler. Faucets for Kitchen sinks to be manual, single lever type with ceramic disc valving, as manufactured by Moen, Kohler or American Standard. e. Shower control valves shall be pressure balance type, solid brass construction. f. For design purposes, all floor drains in spaces other than mechanical equipment rooms shall be considered infrequent use in accordance with the National Standard Plumbing Code. Where practical, gravity type tailpiece trap primers for floor drains are preferred to trap primers hard-piped to the domestic water system. Deep seal traps are acceptable for floor drains in heavy use areas such as Mechanical Rooms. All floor drains shall be equipped with sediment bucket. 3. Plumbing fixtures for janitor s closets shall be as follows (subject to the review/approval of Rutgers Department of Buildings and Grounds on a project by project basis): a. Mop Sinks: Terrazzo, stainless steel or enameled cast iron with low front lip as manufactured by American Standard, Fiat or Florestone. Faucets for mop sinks shall be as manufactured by T & S Brass and Bronze Works, Inc. or equal. b. Service Sinks: Wall-hung, enameled cast iron as manufactured by American Standard or Kohler. 4. All plumbing fixtures must be tight fitting to walls and be neatly sealed at joint with silicone sealant. 5. All piping penetrating walls shall be covered with escutcheon plates. 6. Plumbing fixtures and fittings for laboratory furniture shall be provided by the laboratory furniture manufacturer. 7. Provide freeze-less wall hydrants every 150 on exteriors of new buildings. A minimum of one centrally located wall hydrant shall be provided for each building exposure. Model B65 series as made by Woodford Manufacturing, Inc. or approved equal. 8. Provide vacuum breakers for all plumbing fixtures as required by Code and as required to prevent back-siphonage to domestic water supply. PART III DIVISION 22 PAGE 7 RUTGERS DESIGN STANDARDS MANUAL NOVEMBER 2015

9. All fixtures shall be provided with ¼ turn stop valves (ball valves). 22 45 00 EMERGENCY PLUMBING FIXTURES 1. Eyewash units shall be installed at or near sinks within the hazardous operations space. Such spaces include wet laboratories, areas where dust is generated, darkrooms, mechanical rooms and other areas where liquid chemicals are used or handled. Handheld hose type units providing a soft spray of 3-7 gpm tempered water at a pressure of 30 pounds per square inch are recommended. These may be bench mounted or on the side of the bench or wall, and should be readily accessible and located in a high visibility area near the main door. Wall-mounted units, pedestal-mounted units, eye\face wash units, combination safety shower\eyewash units must be provided with a soft spray of 3-7 gpm at 30 pounds per square inch of pressure. 2. All eyewash units must flush both eyes simultaneously, the flow must remain on without the use of the operator s hands, the unit must remain activated until intentionally cut off and the nozzles must be protected from airborne contaminants. 3. A sign must be posted to identify the location of the eyewash unit and the area behind or around the eyewash unit must be painted with a bright color. Eyewash units for non-ada compliant units should be installed between 2-9 and 3-9 from the floor. For ADA compliant stations, for dimensions ICC ANSI A117.1 standards for drinking fountains shall be followed. However, the appliances shall be eyewash units. 4. Safety showers are to be installed in a conspicuous location, such as a well-traveled aisle, doorway or corridor. They must be within the room or space they serve or within 25 feet of the main room door. Safety showers in corridors can serve several laboratories or PART III DIVISION 22 PAGE 8 RUTGERS DESIGN STANDARDS MANUAL NOVEMBER 2015

rooms. Safety showers must be installed in locations that are accessible at all times. 5. Safety showers are to be installed so that the center of the shower head is at least 25 from the nearest wall, bench or furnishing and at a safe distance away from electrical equipment or outlets. The base of the shower must be between 6-10 and 8 above the floor. The shower head should be a deluge-type head, and should be made of plated brass or plastic. The safety shower unit should be capable of providing a flow of 30-50 gallons of water per minute at 30 pounds per square inch of pressure. 6. Safety shower activating valves are to be operated by pulling either a chain, a cord attached to die valve lever, an 8 diameter ring or a triangle connected by a chain or a cord to the lever. The lowest portion of the ring, triangle or cord should be located no more than 48 from the floor for frontal approach and no more than 54 from the floor for a side approach, and should be run within 1-2 of a wall or bench. Safety shower activating valves are to be quickopening, self-closing globe valves. A shut-off valve accessible from a 6 foot ladder is to be installed for each shower head. 7. A sign must be posted to identify the location of the safety shower, and the area behind or around the safety shower must be painted with a bright color. Exterior safety shower and water supply lines must be protected from freezing. 8. Installation and operation of safety shower and eyewash units must comply with the most recent edition of ANSI Z358.1-standard. 9. The contractor must test each emergency eyewash and safety shower unit prior to building occupancy to confirm compliance with these paragraphs. The test results shall be posted on tags affixed to each unit that includes: the test date, the flow rate, the initials of the person conducting the testing, and whether or not the unit meets these design criteria (pass or fail). In addition, the contractor shall provide the building owner with a list that identifies the type and location of all emergency plumbing fixtures installed in the building. 22 47 00 DRINKING FOUNTAINS AND WATER COOLERS PART III DIVISION 22 PAGE 9 RUTGERS DESIGN STANDARDS MANUAL NOVEMBER 2015

1. Provide lead free materials certification from drinking fountain manufacturer prior to installation. 1. Drinking fountains and water coolers shall be as manufactured by Elkay or approved equal, and shall incorporate a bottle-filler feature. 22 61 13 COMPRESSED AIR PIPING FOR LABORATORY AND HEALTH CARE FACILITIES 22 61 19 COMPRESSED AIR EQUIPMENT FOR LABORATORY AND HEALTHCARE FACILITIES 22 62 13 VACUUM PIPING FOR LABORATORY AND HEALTH CARE FACILITIES 22 63 13 GAS PIPING FOR LABORATORY AND HEALTH CARE FACILITIES 22 66 00 CHEMICAL WASTE SYSTEMS FOR LABORATORY AND HEALTHCARE FACILITIES 22 66 83 CHEMICAL WASTE TANKS PART III DIVISION 22 PAGE 10 RUTGERS DESIGN STANDARDS MANUAL NOVEMBER 2015

22 67 13 PROCESSED WATER PIPING FOR LABORATORY AND HEALTHCARE FACILITIES PART III DIVISION 22 PAGE 11 RUTGERS DESIGN STANDARDS MANUAL NOVEMBER 2015