Field Notification Package for V 17A Software for the STP 420D/ES Tissue Processor



Similar documents
Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

Silicone oil is as the medium and the drying effect is uniform. The Temperature error is less than or equal 1.

SHOWERS SHOWERS

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

ArtisanLink Staining System is an automated special stains slide

GEET Fuel Processor Plans

PREVENTATIVE MAINTENANCE

You motor now is ready to run. Wires Connection: Installing the Controller: Normal start up:

Service Manual. Coffee maker Senseo Viva Café HD7825/30 10/05. Philips Consumer Lifestyle

Thermo Scientific Heratherm Microbiological Incubators. Safe,

Incubator with mechanical convection

Vacuum drying oven for non-flammable solvents

Troubleshooting Guide for Dispenser Model #900172

Freezers - Ultrafreezers. Platilab & Irilab Series

Versalab Print Washer Operating Notes

Draining and filling cooling system

Material test chamber with mechanical convection

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

Air Conditioner P O R T A B L E. Instruction Manual. Your Guarantee. For model WA-1220M WA-1220H, WA-1220E. Portable Air Conditioner / Heater

BB-18 Black Body High Vacuum System Technical Description

How to reduce the cure time without damaging the rubber compound during injection molding?

globe reactions made easy Process perfection

Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

S O SSM. Services. Cat. Management Guide. Accurate Analysis Improved Cost Control Optimized Performance

Thermo Scientific Hi-Temp Programmable Vacuum Oven

Heating oven with mechanical convection

MOUNTING AND OPERATING INSTRUCTIONS

site monitoring Kit Site Monitoring Kit User Manual we prove it.

So instant. Boiling and chilled fi ltered water instantly with Zip HydroTap

Guidelines for Storage and Temperature Monitoring of Refrigerated Vaccines

86 C Freezer Accessories. More Choices. Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories

OPSIS LiquidLINE KjelROC Distillation Unit

FISHER CAM-H300C-3F CAM-H650C-3F CAM-H1300C-3F

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

EXPRESS STILL WARNING It is legal in New Zealand to own and operate a still for the purpose of producing alcohol for your own consumption.

Munchkin Heat Exchanger Maintenance

Diagram of components 2. Reducer..3

WATERBATHS AND OILBATHS

CGC s Hybrid System Loop Control

Standard Operating Procedure

INSTALLATION INSTRUCTIONS BL-8704

CARING FOR YOUR NEW BATH FITTER UNIT

Turbocharger System Optimization

INSTALLATION INSTRUCTIONS MK-8704

Quick start: Panic Watch EU

SWIMMING POOL HEAT PUMP Owners Manual

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

Air Conditioner Water Heater Model ACWH18

Phoenixtech Brushless Motor Speed Controller Programming Guide

STERILIZERS, LABORATORY DRYING OVENS

SOP: Installation of min/max thermometers with the glycerol tube for fridges and freezers

UST RULES CHANGES. Heather Peters, Environmental Specialist

Zip Hydroboil Plus Cuts energy consumption dramatically

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

data sheet DONATELLO Rev. I emiss - 25/10/ PRO03 code Automatic tissue processor DONATELLO

VCR Ion Beam Sputter Coater

Model Voltage (V/Hz) Power (W) Capacity (L) Chamber size Outside size(mm) Weight (kg) STE-TEN 220/ Ø90x160mm W200xH385xD (Net:28)

AUTOCLAVE STEAM STERILIZERS

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

1-Stainless Steel conical fermenter with a thermometer setup.

-86 C Freezer Accessories. New Brunswick Freezer Accessories. A wide selection of racks, monitoring systems and more!

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

ALERT SERVICE BULLETIN December 2012 ENGINE FIRE EXTINGUISHER BOTTLE STEM INSPECTION

Hand Held Centripetal Force Kit

Morco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Heating oven with mechanical control

Coffee Maker Senseo HD7820/70

ORGANIC SAMPLE PREPARATION

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

Use & Care Guide Guide d utilisation et d entretien Manual d uso y cuidado. Premium Water Dispenser with Fingerprint Resistant Stainless Finish

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC

TENDER DOCUMENT PURCHASING EQUIPMENT FOR PEPTIDE SYNTHESIS

not appearance. ADHESIVE SYSTEMS CORIAN As an integral part of its sheet and shape products, DuPont has developed a special adhesive.

Cooling system components, removing and installing

Coolflo Safe Touch Shower Mixing Valve ST20015CP

CAN MONITOR. Technische Alternative elektronische Steuerungsgerätegesellschaft mbh. A-3872 Amaliendorf, Langestr. 124, Fax CAN-MT/F

Free piston Stirling engine for rural development

DETERMINING THE MOLAR MASS OF CARBON DIOXIDE

Installation and maintenance instructions. Danfoss Vent

Free SO 2. by Aeration-Oxidation. A n o t h e r M o r e M a n u a l!

VDL 53 - Vacuum drying oven for flammable solvents

April 29, 2011 FIELD NOTIFICATION

Switch Kit New Account Conversion Checklist

Mazda North American Operations Irvine, CA MX-5 - WATER ACCUMULATION IN FOOTWELL / PLUGGED SOFT TOP DRAINS BULLETIN NOTE

Commercial Semi-Instantaneous Water Heaters

WAYNE FUSION FORECOURT SYSTEM. Meet the new face of. forecourt control.

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Top 10 considerations when validating an autoclave

Section 5: Machine Overview

with installation dynafact boost GAUGE this manual is for use with systems

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE DOUBLE PIPE HEAT EXCHANGER

Transcription:

Field Notification Package for V 17A Software for the STP 420D/ES Tissue Processor Dear Customer, We are very pleased to provide you with software version V 17A on your 420D/ES Tissue Processor. This important update is designed to provide additional security and reliability in the operation of the tissue processor. If you have any questions regarding software version V 17A please call Thermo Fisher Scientific AP Walldorf Factory Service Support +49 6227 836 25499. Thank you for your continued support of the Thermo Fisher Scientific STP 420D/ES Tissue Processor. Sincerely Denise Gerard, HT/HTL (ASCP) 1

Service Bulletin FOR IMMEDIATE RELEASE Date: 20. September. 2010 Media Contact Information: Product affected: Name: Gregor Arlt TYPE STP 420 D/ES Phone: +49 6227 836-25499 Email: fss.dxd.dewal@thermofisher.com Website: www.thermofisher.com Service Bulletin STP 420 D/ES 2010-03-Software Update V17A All procedures described in this service bulletin may only be performed by trained and skilled service personnel. Also refer to the respective user and service manuals of the unit, stick to safety procedures and use common sense while working. This bulletin informs about the Software Update from Version 17 to Version 17A. Also it informs you to check and if necessary to install the silicone rubber stopper in the drip tray. Reason for Update: Failure with media- tube at 51,8 C Problem description: After draining cold xylene the temperature B17 has 52 C and the program gets information to start vacuum for filling paraffin. In the next 3 sec the tube- temperature is falling down because cold xylene went through the tube. 1/3

Solution: a) Switching point will be changed from 52 to 53 C b) If Chamber or rotation valve or media tube is below 53 C then it will be heated for max 15 min c) If one of these temperatures was falling under 53 C because cold reagent was drained then it waits until 53 C before filling is started d) If the program in rotation or biopsy started filling then the filling-software doesn t control the temperature itself. Because the program is controlling the temperature (no double control as in V17) Reason for Update: Avoid overfilling biopsy with paraffin Problem description: If the lower level sensor in biopsy chamber fails and in the same time a filling failure occurs then the chamber can be overfilled and paraffin could come into the system. Solution: After the error message in the filling process the chamber will be drained before the second try to fill again. (This will be happen maximal three times) Reason: In some occasional cases the silicone rubber stopper in the drip tray of the lower reagent department has not been installed and in case of a leak the reagent will drain out under nice the instrument. Solution: Please check and install the stoppers that are included in this upgrade kit if necessary. The drip hole has different diameters. The drip tray is located underneath the lower bottle shelf. Please make sure to use the stopper with the right diameter. The second stopper can be scrapped. 2/3

The new V17A software will be delivered on a memory stick. The instruction how to carry out the update process you ll find in the attached documents. 3/3

Field Notification Package for Software-Update V 17A for the STP 420 D/ES Tissue Processor Update Record Dear colleague, We are providing this Update Record for the Update for the Thermo Fisher Scientific STP 420D/ES Tissue Processor including software version V 17A. To provide you better service in the future we need to document the update status of each unit. We kindly ask for your support in returning the Update Record Confirmation to our Customer Service Support department immediately after performing the update, at the latest by March 31st, 2011. Send Response by Fax to Scarlett Walle: +49 (0) 6227 836-111 If you have any questions please contact Factory Service Support: Email: fss.dxd.dewal@thermofisher.com Phone +49 (0) 6227 836-25499 1

Field Notification Package for V 17A Software for the STP 420D/ES Tissue Processor Installation Record Confirmation Please fax this Installation Record Confirmation back to our Customer Support Team immediately after update, not later than March 31st, 2011. Send Response by Fax to Scarlett Walle: Fax No. +49 (0) 6227 836-111 CUSTOMER INFORMATION Customer / Address: Contact person: STP 420D/ES Serial number: Software Version BEFORE Update: Software Version AFTER Update: I hereby confirm that I have received the additional instructions for use for the Thermo Fisher Scientific STP 420D/ES Tissue Processor and have installed the software update V 17A. Name: Date / Signature: 1