Optimal solar backup. Minimal configuration. General description. Features & advantages. Application Schematic. All Xtender Series

Similar documents
Automatic management of two different energy sources

Data logger and analysis tools

Automatic start of a generator

Anti-blackout system for grid connected solar installations (Solsafe concept)

Data logger and analysis tools

Communication bridge Xcom-MS User Manual

New Trends in Hybrid Systems with Battery Inverter

RCC-02 and RCC-03 for the Xtender

AC Coupling of Inverters for Grid Tied PV Systems

FLOW DIAGRAM OF FIVE DIFFERENT TYPES OF INVERTER SYSTEMS

Additional Solar System Information and Resources

Off-grid solar and backup power installations

Manual. Solar Fountain Mobile Phone Charger

Microgrids and self-generation with renewable energies

PV And Storage: Solutions with Potential

OFF GRID HYBRID POWER PLANT Discover how to maximize the usage of the renewable energy.

Solar Energy Conversion using MIAC. by Tharowat Mohamed Ali, May 2011

Remote Power Systems

PowerGem Pro Uninterruptible Power Supply

Inverter / Charger Installation General Operations and AC and DC Connections

Control of a Hybrid Energy System

Seize the benefits of green energy and the smart grid

HYBRID POWER SYSTEMS for TELECOM applications

SOLAR FARM KITS Off grid/battery backup

Advanced Fuel Cells A Reliable and Green Solution to Reduce Operating Expenses of Telecommunication Networks

Engineered power. Inverter-chargers. Inverters. MPPT solar charge controllers. Battery chargers. Battery monitoring.

MIDNITE SOLAR AND SOLAR WASHINGTON

SOLAR PV INFORMATION. January, 2015

Self Monitoring Power Supply (BPSM)

A Stable DC Power Supply for Photovoltaic Systems

Solar technology. A guide to solar power at utility scale. in Africa

AC Coupling in Renewable Energy Systems

Caravan & Leisure Power Packages

Oxford Case Study: smart local grid storing and sharing solar-generated electricity among networked homes

(EMR) system in resource-constrained settings. The use of the EMR at point-of-care (POC)

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

SA Power Networks Planning for Solar PV? Customer information guide to network connected solar PV inverter systems

Power Management of Cell Sites

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

Challenges during the system design and risk minimization: Demand forecast and possibilities of standardization

Abstract. Introduction

Re-defining the utility-scale inverter

UPS system for emergency lighting and smoke extraction

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

Storage Battery System Using Lithium ion Batteries

SRS2025. Home & small Business. Energy Storage Solution

K.Vijaya Bhaskar,Asst. Professor Dept. of Electrical & Electronics Engineering

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

EssPro Energy Storage Grid Substation The power to control energy

Photovoltaic Solar Energy Unit EESFB

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

Batteries and inverters

CUTES Solar Power System

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

Technical Guidance and Testing Procedure for Static and Dynamic Demand Response and Battery Storage Providers of Frequency Balancing Services

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

ABB central inverters PVS to 1000 kw

HOW A DC UTILITY METER CAN TRANSFORM THE U.S. SOLAR INDUSTRY

Achieving the impossible

WHITEPAPER ON OFFGRID AND BACKUP SYSTEMS. Fronius Microgrid Solution Fronius PV-Genset Solution

YSmart Technology Co.,Ltd

DC MICROGRIDS A SOLAR BACK TO THE FUTURE

Solar Energy - the closest Introduction. thing to Free Power... What most people want to know first. Solar Trading Post

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

875 Dearborn Drive Columbus, Ohio Tel: (614) Fax: (614)

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

Solar Power for PC Deployments: Enabling ICT Beyond the Grid

46120-F0 Solar Energy Training System

Stationary Energy Storage Solutions 3. Stationary Energy Storage Solutions

Technical Information Battery Management of the Sunny Island Gentle charging control for lead-acid batteries based on current state of the battery

LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

Using the sun to generate electricity

Energy'Saving,'Thermal'Comfort'and'Solar'Power'Information'Sheet'

SNMP Web Management. User s Manual For SNMP Web Card/Box

Solar Wind Microhydro Water Pumping Inverters Batteries Professional system design and installation

300 MY HOME Energy management

Technical specification

RELAYS Solar Energy Systems

INVERTER SYSTEM PRODUCT BROCHURE

Advanced Electricity Storage Technologies Program. Smart Energy Storage (Trading as Ecoult) Final Public Report

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Xantrex Solar Monitor Widget. User Guide

Reducing operating costs of telecom base stations with remote management

/ The allrounder with maximum yield. / WLAN interface / Smart Grid Ready

Techniques for Interconnecting Smart Wireless Gateways to ProSoft RadioLinx Devices

Selecting a UPS Topology for your Data Center. by Dr. Daniel Becker, Ph.D., Methode Active Energy Solutions

Going Solar ACTIVITIES

Renewable Energy Hosting Capacity in Horizon Power Systems. November 2013

MAJORSINE Power Inverter

BC Pro UPS System Standby UPS System

SOLAR PV + HOT WATER: An Introduction

Constant Voltage Charger Selection for VRLA Batteries

Leveraging Renewable Energy in Data Centers: Present and Future

Transcription:

AN-002-V.1.9.4 STUDER INNOTEC SA Optimal solar backup General description This application note describes how to use renewable energy in a backup system, even when the system is connected to a grid and grid feeding is not possible. Features & advantages Ideal for backup systems with renewable energy where there is no feed-in tariff or where grid feeding is not possible. Use all of the available renewable energy. Direct use of renewable energy without cycling energy in the battery(-ies) to avoid their premature aging. Minimal configuration Range of inverters o All Xtender Series Xtender o Software vers. RCC-02/-03 o Software vers. : 1.3.28 and higher : 1.3.32 and higher o RCC User level : EXPERT Attention! This function cannot be used with two or three Xtenders connected in parallel. The 3-phase system is allowed but only with one unit per phase. Application Schematic (Figure 1) Backup system using renewable energy without grid feeding Page 1 / 7

Detailed description Operation description In a backup system, the power to the end consumer is taken from the input (grid, generator ) or, in a blackout situation, from the DC side (battery(-ies), renewables). Generally, in the case where grid feeding is not possible, the renewable energy is lost when the system is powered from input. This application note shows the possibility to use the renewable energy of the system even when the system is connected to a grid. This operation requires an inverter-charger from the Xtender series with two special functions. The Smart-Boost i function which adds power to the AC source according to the input limit current. The solar priority function which adjusts the instantaneous power consumed from the source according to the battery(-ies) voltage. The operation of the solar priority function is done with an automatic modification of the input limit current. The input limit current is decreased from the initial value (given by the user) if there is enough energy available at the DC side. The lower the input current, the more the load is provided with DC power by the Smart-Boost function. In this way, the power from the DC side is integrated in the system and the input consumption is limited. (Figure 2) Smart-Boost function Battery priority voltage, description and dimensioning The point where the input limit starts to decrease is the priority voltage of the battery(-ies), parameter {1297} ii. This parameter sets two zones in a battery(-ies): A zone below this point, which ensure an energy reserve for a blackout situation. A zone above this point where the renewable energy in excess can be stored. When there is higher production of renewables than power consumed, it is possible to store this production in the battery(ies) s buffer zone for later use (see figure 4). (Figure 4) Load profile with renewable energy buffered An example to determine the value of the battery(-ies) priority voltage considering a battery(-ies) of 24Vdc (Full battery(-ies) = 25.5Vdc, empty battery(-ies) = 24Vdc) and a backup zone of 80% of the total capacity of the battery(-ies) : -Full battery(-ies) (Fullbat) = 25.5Vdc -Empty battery(-ies) (Emptybat) = 24.0Vdc Battery(ies) priority voltage is : Emptybat + 80% * (Fullbat Emptybat) = 24 + 0.8 * (25.5 24) = 25.2Vdc Note that even with the battery priority voltage, the battery charging proceeds normally and accepts the absorption and equalization phases. Thus, it is possible to program absorption and equalization phases to reduce the problem of stratification of the acid and the water decrease in the batteries. But to avoid cycling the batteries too often, it is necessary to adjust the parameter {1297} (Battery priority voltage) to a value higher than the parameter {1143} (Battery voltage level 1 to start a new cycle). (Figure 3) Battery priority voltage Page 2 / 7

Saving the renewable energy or the battery(-ies) life? In such a system, there is the choice between storing or not the renewables in excess. If renewable energy is stored, energy in the battery(-ies) will therefore be cycled, implying a decrease of the battery(-ies) lifetime. If renewable energy is not stored, it will be lost but the energy in the battery(-ies) will be stable, implying an extension of the battery(-ies) lifetime. The question is whether to store the excess renewable energy not? Where the price of battery(-ies) storage is cheaper than the cost of grid/generator energy, it is advisable to store the renewables in excess. Otherwise, if grid/generator energy is cheap, it is advisable not to store the renewables in excess. If the renewable energy production in excess is not buffered (Figure 5), the battery(-ies) priority voltage should be set, for example, to 0.5Vdc below the floating voltage of the solar/wind regulator. The battery(-ies) priority voltage should also be set to 0.5Vdc below the floating voltage of the solar/wind regulator to keep it loaded to a maximum. Operating example For example, if battery(-ies) are higher than the priority voltage and if a solar panel is connected to the battery(-ies) at the DC side, its regulator (MPPT or other) provides solar power to the DCbus. At the same time, the Xtender will take away the solar power to maintain the DC-Bus at the priority voltage. This represents a direct use of the solar power in the final user load, without cycling energy in the battery(-ies). If battery(-ies) are lower than the priority voltage, solar power is used to recharge the battery(-ies). Charging from the grid is now allowed because the objective is to keep the battery(-ies) charged for backup time (generator is off, blackout, no more sun, ). For proper functioning of the system, the voltage target of the solar/wind regulator should therefore be above the battery(-ies) priority voltage. Solar priority function s algorithm The solar priority function s algorithm maintains the battery(-ies) at a proper level for long lifetime and always keeps a reserve of energy for backup. The input limit is reduced linearly over a working range as shown in the graphic below: (Figure 5) Load profile without renewable energy buffered Another case concerns the situation where there is no excess renewable energy (Figure 6). (Figure 4) Graph of Solar priority function. (Current taken on the AC source depending on the battery(-ies)) (Figure 6) Load profile without excess of renewables Page 3 / 7

Parameters Four parameters iii allow controlling the energy management with different sources: Notes 1. Battery(-ies) priority as energy source {1296} 2. Smart-Boost allowed {1126} 3. Battery(-ies) priority voltage {1297} 4. Maximum current of AC source (Input limit) {1107} Associated application notes : AN001 AC source assistance (Smart Boost function) i ii iii More information about the Smart-Boost is available on the AN001 AC source assistance (Smart-Boost function) The voltage values for the battery(-ies) priority voltage {1297} are available at the next page, item : Battery(-ies) priority voltage More information about the source max AC current and the battery(-ies) priority voltage are available at the next page Page 4 / 7

RCC -02 / -03 programming guide 1. User level to EXPERT 3. Batteries priority as energy source 2. Smart-Boost allowed 4. Battery priority voltage Page 5 / 7

5. Maximum current of AC source (Input limit) Page 6 / 7

Notes Worldwide sales and service Switzerland Studer Innotec SA Rue des Casernes 57 1950 SION / Switzerland Tel : 027 205 60 80 / Fax : 027 205 60 88 Email: info@studer-innotec.com Web : http://www.studer-innotec.com Limitation of responsibility The use of STUDER INNOTEC SA devices is the responsibility of the customer in all cases. STUDER INNOTEC SA reserves the right to make any modifications to the product without prior notification. Page 7 / 7