SignalPad Data Logging and Analysis Software

Similar documents
Sound and Vibration Analysis Software

LMS Test.Xpress Powering personal productivity

Three Levels of Data-Logging Software from National Instruments

Increase System Efficiency with Condition Monitoring. Embedded Control and Monitoring Summit National Instruments

ECONseries Low Cost USB DAQ

Embest DSO2300 USB Oscilloscope

Modular Instrumentation Technology Overview

Architecting High-Speed Data Streaming Systems. Sujit Basu

Vibration analysis and monitoring Compact. Powerful. Modern technology.

NI Platform for automotive measurement and test applications

EDM SOFTWARE ENGINEERING DATA MANAGEMENT SOFTWARE

Automotive. Aerospace. bout Us. Defense. Energy. Maritime. Education. Electronics. and more

The Universal DAQ Device. Connect and measure immediately!

Arun Veeramani. Principal Marketing Manger. National Instruments. ni.com

Stuart Gillen. Principal Marketing Manger. National Instruments ni.com

WIRELESS ASSET MONITORING

EMX-2500 DATA SHEET FEATURES GIGABIT ETHERNET REMOTE CONTROLLER FOR PXI EXPRESS MAINFRAMES SYSTEM LEVEL FUNCTIONALITY

RF Measurements Using a Modular Digitizer

DS-3000 series Sound and Vibration Real time Analysis System

DAQ in MATLAB HANS-PETTER HALVORSEN,

Measuring Temperature withthermistors a Tutorial David Potter

imc BUSDAQ autonomous intelligent synchronized Field bus data acquisition - from stationary to mobile imc productive testing

APPLICATION NOTE GaGe CompuScope based Lightning Monitoring System

Simplify Data Acquisition with a Built-in LXI Web Server

Summer of LabVIEW The Sunny Side of System Design

Cell Phone Vibration Experiment

LMS Pimento. The Multichannel Analyzer with Portable Power

PXI Express Chassis with Integrated MXI-Express Remote Controller

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

DEVELOPMENT OF DEVICES AND METHODS FOR PHASE AND AC LINEARITY MEASUREMENTS IN DIGITIZERS

Data Acquisition in LabVIEW

EDM Cloud Remote Monitoring Solutions. Crystal Instruments, January 2014

Basics of Simulation Technology (SPICE), Virtual Instrumentation and Implications on Circuit and System Design

Multi-Range Programmable DC Power Supplies 9115 Series

This document lists the specifications for the NI PXIe-5160, 500 MHz digitizer.

Siemens and National Instruments Deliver Integrated Automation and Measurement Solutions

Introduction to Data Acquisition

Practical On-Line Vibration Monitoring for Papermachines

High speed pattern streaming system based on AXIe s PCIe connectivity and synchronization mechanism

Multi-Range Programmable DC Power Supplies 9115 Series

Nutaq. PicoDigitizer 125-Series 16 or 32 Channels, 125 MSPS, FPGA-Based DAQ Solution PRODUCT SHEET. nutaq.com MONTREAL QUEBEC

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

How To Develop An Iterio Data Acquisition System For A Frustreo (Farc) (Iterio) (Fcfc) (For Aterio (Fpc) (Orterio).Org) (Ater

Soundbook. The 2nd generation of our Soundbook acoustics analyzer - now based on the new 24 bit Apollo hardware platform

On-line Machine Condition Monitoring [The CMS System]

Eight Ways to Increase GPIB System Performance

Using NI CompactDAQ Controllers

EBERSPÄCHER ELECTRONICS automotive bus systems. solutions for network analysis

Integrated Data Acquisition Signal Conditioning Systems

Introduction to Digital Audio

FREQUENCY RESPONSE ANALYZERS

Application Note Receiving HF Signals with a USRP Device Ettus Research

Bioreactor Process Plant Powered by NI LabVIEW and NI CompactRIO

System 1* Condition Monitoring and Diagnostic Software. Premium Package

ni.com/sts NI Semiconductor Test Systems

Analogue/Digital Analogue and Differential Oscilloscopes

A&E Specifications RoadRunner Video Surveillance Systems for School Transportation Applications

NETWORK ENABLED EQUIPMENT MONITOR

Automated Data Acquisition & Analysis. Revolutionize Validation Testing & Launch With Confidence

1701/22 FieldMonitor Management Interface Module

I2C PRESSURE MONITORING THROUGH USB PROTOCOL.

ATM Video Surveillance

Energy Storage System Performance Testing

The next generation of noise measurement instruments

Machinery condition monitoring software

ni.com/vision NI Vision

Integrating PCI Express into the PXI Backplane

Demystifying Wireless for Real-World Measurement Applications

Understanding the Effect of Uncorrelated Phase Noise on Multi-channel RF Vector Signal Generators and Analysers

PCI Express Clock Specifications and Effect on NI PXIe-PCIe8375 Interoperability. White Paper

[Download Tech Notes TN-11, TN-18 and TN-25 for more information on D-TA s Record & Playback solution] SENSOR PROCESSING FOR DEMANDING APPLICATIONS 29


DT9836 Series. BNC Connection Box. OEM Embedded Version

PCXpocket 440. Professional Digital Audio Card. User s manual. DU IS=A

GETTING STARTED WITH LABVIEW POINT-BY-POINT VIS

The Development of a Pressure-based Typing Biometrics User Authentication System

Keysight N9320B RF Spectrum Analyzer

Use Data Budgets to Manage Large Acoustic Datasets

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

Machine Condition Monitoring Systems

Benefits and Potential Dangers of Using USB for Test & Measurement Applications. Benefits of Using USB for Test and Measurement

Audio and Video Door Entry System LIELBA - AD14

Type-D EEG System for Regular EEG Clinic

Sistemi di acquisizione. Grazie al sito National Instruments

WINDAQ Data Acquisition and Playback Software

U1602A Handheld Oscilloscopes, 20 MHz

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

Agilent M9703A AXIe Digitizer

SABRE Lite Development Kit

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

What s New in Mike Bailey LabVIEW Technical Evangelist. uk.ni.com

Lab 3: Introduction to Data Acquisition Cards

Test for I-DEAS FEATURES APPLICATIONS A TRANSIENT POST-PROCESSING SOFTWARE FOR FIXED SAMPLE ORDER TRACKING

USB-500 Series Stand-Alone, Low-Cost Data Loggers

DAC Digital To Analog Converter

Transcription:

SignalPad Data Logging and Analysis Software Overview SignalPad is a data logging and analysis application developed with National Instruments LabVIEW. The configuration-based user interface provides ready-to-run functionalities for you to perform signal acquisition, storage, playback, and analysis. You can use SignalPad to acquire signals, such as voltage, current, sound, vibration, strain, temperature, and CAN, through integration with NI DAQ hardware. The analysis functions include power spectrum, filtering, integration, mathematics, sound level, vibration level, frequency response function, octave analysis, order tracking, waterfall, sound power, sound intensity, modal analysis, and so on. Features No programming required Seamless integration with NI DAQ devices Configurable and easy-to-use user interface Comprehensive noise, vibration, and strain signal processing functionalities, which include filters, power spectrum, frequency response, shock response spectrum, octave, colormap, waterfall, order tracking, sound power, sound intensity, microphone array noise source identification, principal stresses/strain, and so on Applications Combined with NI DAQ hardware, including PXI, CompactDAQ, and CompactRIO dynamic signal acquisition modules, SignalPad offers an efficient tool for performing data logging and sound, vibration and strain applications. Simple configuration steps enable high channel counts (up to hundreds of channels) and high sample rates (up to 100 MS/s) of DAQ and analysis applications. Data logging and playback Machine condition monitoring Structural test and modal test Noise, vibration, and harshness Acoustic test and rub & buzz test Microphone array, sound camera Fatigue analysis, principal stresses/strain 1

Advantages of SignalPad Data Logging and Analysis Software Comprehensive set of analysis functions for sound, vibration and strain applications SignalPad has integrated almost all of the signal processing and analysis functions of LabVIEW, such as FFT power spectrum, octave spectrum, sound level, order tracking, waterfall, envelop detection, correlation, cepstrum, cross spectrum, loudness, sharpness, and so on. SignalPad also adds many new functions to extend NI hardware to more application areas. For example, you can use SignalPad to calculate effective shock duration measurement, shock response spectrum, sound power, sound intensity, and noise localization by sound camera (microphone array), and so on. Support of multiple international standards SignalPad extends NI LabVIEW functions to support multiple international standards in more specific domains, including but not limited to: - Sound power, sound intensity: IEC 61043, ISO 9614-1, ISO 9614-2,ISO 3745 - Sound absorption coefficient and impedance measurement: ISO10534-1,SO10534-2,GB/T-18969.2 - Vehicle pass-by noise testing: ISO 10844-1994, GB 1495-2002, GB 1496-1979 - Sound quality evaluation of automobile subsystem or component: GMW14155, GMW14240 - Loudness: DIN45631 - Noise testing of wind turbine power generator: IEC 61400-11 Ed2.1, BWEA, AWEA, GBT 22516-2008 Better hardware integration - CompactRIO in-vehicle data logging CompactRIO is ideal for in-vehicle data logging because of its rugged hardware architecture and small form factor. Temperature ranges of -40 C to 70 C (-40 F to 158 F), 50 g shock rating, and a variety of international safety, electromagnetic compatibility (EMC), and environmental certifications and ratings are all available with CompactRIO. With the SignalPad customized CompactRIO firmware, you can now use the CompactRIO system with SignalPad just like using NI EthernetDAQ system and no programming skill is required. SignalPad supports acquisition of different types of physical signals critical to a vehicle, including voltage, current, pressure, temperature, strain, vibration, and noise. Signals on a CAN bus can also be acquired and logged by SignalPad as well as GPS signal via UART. SignalPad customized CompactRIO firmware also includes a start-up application running in LabVIEW Real-Time, which makes the CompactRIO a standalone system. This means you can use CompactRIO as a data logger without computer in field and download the data from CompactRIO when you are back to the office. Better hardware integration - High throughput data acquisition SignalPad is optimized for high throughput data acquisition. You can use SignalPad to acquire data of hundreds of channels, or you can acquire data with very high sampling rate. The playback UI of SignalPad is well-designed for large data preview and processing. For example, you can use SignalPad to acquire data from multiple NI 6368 modules running at 2.00 MS/s per channel. *For high throughput application, Solid-State Disk (SSD) or RAID is recommended. 2

Better hardware integration - Synchronized acquisition using multiple high-speed digitizers By leveraging NI-TClk technology, SignalPad can synchronize multiple high-speed digitizers. TClk provides a high level of synchronization between instruments by aligning sample clocks that may not be initially aligned despite being phase-lock looped. TClk can align sample clocks and keep them aligned over time. With TClk, SignalPad can ensure that multiple devices can react to the same trigger signal in the same clock period, which results in a synchronized acquisition. SignalPad minimizes the complexity of multiple digitizer synchronization. You can easily use SignalPad to accomplish a synchronized acquisition task of multiple high-speed digitizers. Better hardware integration - Synchronized acquisition of massive channel count DSA channels SignalPad provides customized real-time applications, which enable synchronization between multiple PXIe chassis using NI PXIe-6674T, IEEE 1588 or GPS. You can acquire and log data in each chassis controller separately and download the data later. Using an 8-slot PXIe chassis and 6 NI 449x DSA board, each chassis can provide the ability of acquiring 96 channels simultaneously. The phase difference between any selected channels does not exceed 0.5 degrees (1 khz). This structure has been verified on a system with 400+ DSA channels and proved to be reliable. You can also use SignalPad to acquire data from multiple NI CompactRIO chassis simultaneously. SignalPad Package Selection Guide SignalPad provides the following packages to meet the requirements of different applications from basic data logging to advanced processing with domain specific. Basic - Supports general data logging, display, and playback with NI DAQ devices. Full - Supports math functions, analysis functions for time domain and frequency domain, limited sound and vibration measurement. Professional - Supports all the functions for data logging and play back, advanced DAQ support, math & signal processing, basic & advanced sound vibration functions, and so on. Ultimate - Supports additional comprehensive applications, like sound camera, or test procedure to meet the industry domain standards. You can order SignalPad via National Instruments by using the following part numbers. NI Part Number Description 783878-35 SignalPad Basic 783879-35 SignalPad Full 783880-35 SignalPad Professional 783881-35 SignalPad Ultimate 3

Category Function Basic Full Professional Ultimate Data Logging and Playback Advanced DAQ Support Signal Processing and Measurement Basic Sound and Vibration Strain and Fatigue Advanced Sound and Acquire, storage, and playback with NI DAQmx Save raw data as TDMS Play back data Waveform display XY graph display Numeric display Table display Cursor value reading and measurement Export data to TXT/CSV/Excel Export data as graphics Play signal through PC sound card Signal generation Multiple digitizer synchronization High-speed DAQ (ex. PXIe 6368) CompactRIO Multiple PXI chassis synchronization for massive channel DAQ Power spectrum Filters Statistics Histogram Integration Re-sampling Math Correlation Cross spectrum Phase difference Frequency/Phase/THD/SNR Sound level Vibration level Octave spectrum Tachometer Order spectrum Order tracking Colormap Waterfall (along with slice view) Orbit/Timebase plot Polar plot Cepstrum Envelop detection Time-varying loudness Specific loudness Time-varying sharpness Specific sharpness Fatigue load spectrum Fatigue damage spectrum Principal stresses/strain Shock duration measurement Shock response spectrum 4

Category Function Basic Full Professional Ultimate Vibration Frequency Response Domain Specific Sound power Sound intensity Impedance tubes Microphone array sound camera Wind turbine noise evaluation (IEC61400-11 Ed2.1, AWEA 9.1, BWEA 2008) Vehicle pass-by noise test (GB1495-2002, ISO-362-1998) Automobile subsystem and component sound quality evaluation (GMW14155) Recommended Hardware For sound and vibration data acquisition, KeyGo Technologies recommends NI DSA devices. With 24-bit ADCs and DACs and integrated anti-aliasing filters, DSA devices are ideal for acoustic, noise, and vibration measurements. Product Bus Input Resolution (bits) Dynamic Range (db) Sampling Rate per Channel Analog Input Input Range Gain Settings Coupling TEDS Support Analog Output High-Performance NI 4461 PXI, PCI 24 118 204.8kS/s 2 ±42 V to 316 mv -20 to 30 db in AC/DC Yes 2 NI 4462 PXI, PCI 24 118 204.8kS/s 4 ±42 V to 316 mv -20 to 30 db in AC/DC Yes 0 High-Density NI 4492 PXI 24 114 204.8kS/s 8 ±10V to 1V 0 and 20 db AC/DC Yes 0 NI 4495 PXI, PXIe 24 114 204.8kS/s 16 ±10 to 1 V 0 and 20 db DC Yes 0 NI 4496 PXI, PXIe 24 114 204.8kS/s 16 ±10 to 1 V 0 and 20 db AC Yes 0 NI 4497 PXI, PXIe 24 114 204.8kS/s 16 ±10 to 1 V 0 and 20 db AC/DC Yes 0 NI 4498 PXI, PXIe 24 114 204.8kS/s 16 ±10 V to 316 mv 0 and 30 db in AC Yes 0 NI 4499 PXI, PXIe 24 114 204.8kS/s 16 ±10 V to 316 mv 0 and 30 db in AC/DC Yes 0 Low-Cost NI 4472 PXI, PCI 24 110 102.4 ks/s 8 ±10 V N/A AC/DC - 0 NI 4474 PCI 24 110 102.4 ks/s 4 ±10 V N/A AC/DC - 0 Portable/Compact NI 4431 USB 24 100 102.4 ks/s 4 ±10 V N/A AC/DC Yes 1 NI 4432 USB 24 101 102.4 ks/s 5 ±40 V N/A AC/DC Yes 0 NI 9218 USB, WiFi 24-51.2kS/s 2 ±16 V or ±65mV N/A AC/DC - 0 NI 9232 USB, WiFi 24 99 102.4 ks/s 3 ±30 V N/A AC/DC Yes 0 NI 9234 USB, WiFi 24 102 51.2 ks/s 4 ±5 V N/A AC/DC Yes 0 NI 9237 USB, WiFi 24-50 ks/s 4 ±25 mv/v N/A - - 0 NI 9214 USB, WiFi 24-1,088 S/s 16 ±78.125 mv N/A - - 0 TEDS = transducer electronic data sheet 5

More about SignalPad The SignalPad Data Logging and Analysis Software is developed fully based on National Instruments LabVIEW and provides perfect support for NI data acquisition devices. The SignalPad development team has rich experience in LabVIEW software development and signal processing, and provides professional technical support and services. Contact KeyGo Technologies Shanghai KeyGoTech Co., Ltd Tel:+8621 5186 0355, +86 1381 8060 599 Website:http://www. Email:sales@keygotech.com Address: 2208 Fortune International Plaza Silver Villa, 43 Guoquan Road, Shanghai, China Zip Code: 200433 6