Risk Assessment Based Environmental Management Systems for Petroleum Retail Stores



Similar documents
UDOT SPILL PREVENTION and RESPONSE PLAN for CONSTRUCTION SITES

SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES TOXIC/HAZARDOUS MATERIAL TRANSFER FACILITY DESIGN GUIDELINES

Civil Engineering Sector Labour-Management Health and Safety Committee

Summary of Environment and Social Impacts for Activates Associated with Petroleum Refining and the Storage of Petroleum Products

Fire & Explosion Risks in Service Stations

ALLEGANY WIND POWER PROJECT CONSTRUCTION SPILL PREVENTION PLAN

Improper storage of fuel on construction sites will increase the risk of water pollution that may occur as a result of leaks or spills.

CHAPTER PETROLEUM CONTACT WATER

Florida Department of Environmental Protection

Outdoor Storage of Raw Materials SC-33

APPENDIX 4. Risk Tables

Twenty-four contracting services environmental claim scenarios you may not have thought about.

LIQUID WASTE TREATMENT FACILITY MENDIS ROAD, HUDSON CREEK DRAFT GUIDELINES FOR A PUBLIC ENVIRONMENTAL REPORT

Hazardous Waste Accumulation, Storage, & Labeling

District of Columbia Municipal Regulations UNDERGROUND STORAGE TANKS: GENERAL PROVISIONS 5500 COMPLIANCE WITH OTHER DISTRICT LAWS

Chapter 2 Stormwater Pollution Prevention Plan (SWPPP) for Park Operations

Source Water Protection Practices Bulletin Managing Sanitary Sewer Overflows and Combined Sewer Overflows to Prevent Contamination of Drinking Water

Presented by: Craig Puerta, PE, MBA December 12, 2012

COMPLIANCE MANAGEMENT STRATEGIES. Presented by: Megan Kazmierczak, ECS Eclipse

Spill Prevention, Control and Countermeasure (SPCC) Rule

Spill Control Prevention Plan (SCPP)

DRAFT REVISED Musts For USTs DRAFT. Printed on Recycled Paper. Updated June 2015

APPENDIX G Materials Storage and Handling Guidelines

Spill Prevention, Control & Cleanup SC-11

MPM. Customer Service Representative Training. Class C Fuel Spill Handling

New York State Department of Environmental Conservation 625 Broadway, Albany, NY Environmental Self Audit For Small Businesses

MAGB HEALTH, SAFETY AND ENVIRONMENT GROUP POLLUTION INCIDENT RESPONSE PLAN

UPDATE ON MAINE'S UNDERGROUND TANK LAWS

RULE ORGANIC COMPOUNDS - WASTEWATER COLLECTION AND SEPARATION SYSTEMS

2. determining that land is not contaminated land and is suitable for any use, and hence can be removed from the CLR or EMR, as relevant.


NAPCS Product List for NAICS 54162: Environmental Consulting Services

Environmental Management System Procedures

Stormwater Ponds. c ıty of a bı le ne st or m wat e r utı lıty dıv ısı on

Extraction Oil and Gas, LLC. Diamond Valley Central Oil Terminal Waste Management Plan

UltraTech International, Inc. Canadian Secondary Containment Requirements

Environmental Management Plan

PREVENTING GROUNDWATER POLLUTION: SECONDARY CONTAINMENT

Waste Handling & Disposal

ALL UST SYSTEMS. MOTOR FUEL, USED OIL, BULK HEATING OIL STORAGE (Federal/State Regulated Systems)

FUELING AND FUEL STORAGE

Outdoor Liquid Container Storage

FINAL PLAN OF REMEDIAL ACTION

Guide to the Remediation Report & Fee Submission Form

Chemical Storage and Spill Response Guidelines

Defence College of Technical Training. Former RAF Lyneham Geo-Environmental Report Appendix D: Preliminary Qualitative Risk Assessment

IAC 7/2/08 Agriculture and Land Stewardship[21] Ch 44, p.1

SILICON VALLEY CLEAN WATER. May 2015

The Fuel Storage Tank Regulations 2009

Improper storage of potential pollutants will increase the risk of water pollution that may occur because of spills.

Underground Storage Tanks

Application for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems

SOP 4: Spill Response and Cleanup Procedures SOP 4: SPILL RESPONSE AND CLEANUP PROCEDURES

ENGINEERED DRAWINGS FOR PETROLEUM STORAGE TANKS

DRAFT Guidelines for Manually Diverting Outdoor Wastewater to the Sanitary Sewer

APPENDIX O. Spill Prevention and Emergency Response Plan. G3 Terminal Vancouver Port Metro Vancouver Project Permit Application APPENDIX O

THE CORPORATION OF THE CITY OF COURTENAY BYLAW NO A bylaw to amend Storm Sewer Bylaw No. 1402, 1986

DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY. August 2012

ANNEX 2 Emergency / Pollution Incident Response Plan

2006 Standard Application Processing Time. 10 months. 14 months

31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE

Pollution Prevention And Best Management Practices For Dry Cleaners Operating In Broward County

Waste Oil Collection / Storage

SPILL PREVENTION AND RESPONSE PLAN TEMPLATE FOR BUSINESSES IN DAYTON S SOURCE WATER PROTECTION AREA

History of the SPCC Rule

Identifying Environmental Aspects

ENVIRONMENTAL QUESTIONNAIRE - REAL ESTATE SECURED LOANS

Good Housekeeping Practices for DPW/Fleet Maintenance Facilities

Citgo Service Station (Former Gulf Oil/Chevron) Jarrettsville Pike Baltimore County Jacksonville, Maryland Open Case No.

MBJ Environmental Programmes

POLLUTION PREVENTION FACT SHEET: AUTOMOBILE MAINTENANCE

Radioactive Waste Storage Facility and Tank System Design Criteria Standards

Proposed Terms of Reference for EIA studies

APPENDIX 7-B. Hazardous Materials Management Plan

Q 4/17/13: Thank you for your quick response to our dated April 10, In looking over your comments, we have a few clarifying remarks.

Secondary Containment & Spill Buckets Inspection, Testing, and Repair Solutions. Allen Porter May 28, 2015

Environmental guidelines for preparation of an Environment Management Plan

DESCRIPTION OF STORMWATER STRUCTURAL CONTROLS IN MS4 PERMITS

SHORELINE SANITATION

Petroleum Storage Tank Spill and Overfill Prevention

UNIVERSITY OF WISCONSIN MADISON

Type of Sewer Systems. Solomon Seyoum

MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION

Asbestos Storage Facility Plan Examples

GUIDANCE FOR DEVELOPMENT OF SPILL AND SLUG PREVENTION CONTROL PLANS AND FACILITIES FOR THE CITY OF ATTLEBORO SEWER USERS

Fiberglass Storage Tanks for Green Building Applications

Hazardous Materials Storage Tanks Management. Procedure Date of Issue: Table of Contents. UBC.EMS Advisory Committee.ENV.Procedure.

2013 CONSTRUCTION CONTRACTOR CATALOGUE ECATTS. Copyright ECATTS. All Rights Reserved.

Managing Floor Drains and Flammable Traps

6 Chemicals from human settlements

SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN

Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil)

Domestic heating Fuel storage tanks

CHAPTER 17. Sewers and Sewage

Transcription:

Risk Assessment Based Environmental Management Systems for Petroleum Retail Stores NATO/CCMS Pilot Study Prevention and Remediation In Selected Industrial Sectors: Small Sites in Urban Areas Prof. Cem B. Avcı Bosphorus University Civil Engineering Department Istanbul Turkey

GASOLINE RETAIL STORE SECTOR 10,000 Retail Stores Multinationals (BP, Shell, Total %15) 45,000 Underground Storage Tanks Mature Sector Privately Owned Licenses (95%) Standards for Retail Store Construction & Operations Upgraded in 2005 Low Focus of Public Authority for Environmental Concerns Urban Settings Concern for Safety Challenges for Remediation (expensive-effectiveness)

ENVIRONMENTAL MANAGEMENT SYSTEMS Environmental Management System (EMS): planning tool that may prevent unacceptable operational risks associated with the activities undertaken. Risk management tool in Petroleum Retail Stores with prevention is better than cure philosophy Enhancement to existing environmental protections and planning presently implemented at the retail sites. Flexibility taking into account specific industry initiatives as well as site conditions ensuring that company based minimum environmental considerations could be integrated into business decisions in a systematic way.

POLICY Environmental Policy is the basis for the EMS implementation and the approach to environmental performance: To conduct activities in manner that is environmentally responsible with the aspiration of no damage to the environment. Seek to drive down the environmental impact of its operations by reducing waste, emissions and discharges and by using energy efficiently.

OBJECTIVES Policy forms the framework of the Environmental Objectives. Likely objectives would be: Compliance with all local environmental laws, regulations and site specific conditions of authorization, together with the setting of self-imposed responsible standards to achieve higher standards Continuous control, assessment and review of environmental risks associated with all performances and subsequent improvements Continuously improve the environmental awareness of employees, contractors and customers Reduce waste, emissions and discharges and improve efficiency of natural resources and energy usage.

TARGETS Environmental Targets identified to achieve the environmental objectives. Actions should be taken and subsequently followed up, assessed to achieve these targets. Likely targets would be: Prevent unacceptable environmental risks associated with operational facilities Minimize unwanted events Complete actions related to environmental risk prevention in time Complete the planned maintenance and training in time Maintain costs for energy for every 1000 liters of product below Maintain water usage for every 1000 liters of product sold below

ORGANIZATION IENTS Station Employees STATION CONTRACTOR S UPPER MANAGEMENT Station EMS Coordinator FIELD AUDITORS EMS SYSTEM AUDITORS Retail Upper Management: Identify and approve the Environmental Policy and Objectives. Retail Stations EMS Coordinator Keep risk assessments up-to-date. Compare the risk-control mechanisms for the station Responsible for starting and following up actions. Plan and implement six month station field audits. Designated Station Personnel Responsible for the Environment (Station EMS Personnel) Review the implementation of the requirements of an EMS. Perform spot training. Follow unwanted actions and undertake the necessary improvements Field Auditors Field auditors to undertake and prepare reports for audits under the supervision of the EMS coordinator once every six months EMS System Auditors EMS system auditors to undertake and prepare reports for EMS audit under the coordination of the EMS coordinators once every six months Station Employees Responsible for following procedures for activities based on written documentation and internal training, inform the clients and contractors Contractors Responsible for following procedures related to their work as written in the Contractor HSE Requirements for company

IMPLEMENTATION Environmental Regulations and Legislative Changes Activities Performed (normal and unwanted events) Environmental Risk Assessment (ERA) Identifying potential impacts for soil, ground water, surface water and air quality of operating a petroleum retail store using source pathway receptor point of view Preventative measures taken for unacceptable risks (include the training, inspection and level of readiness of the personnel). Audits Assessments

ERA Zone Segregation STATION ZONES 1. Fuel Forecourt Area 2. LPG Forecourt Area 3. Fuel tank area 4. LPG tank area 5. Car Wash 6. Market-offices 7. Support facilities 8. Waste storage area RETAIL STORE 5 4 1

ERA-Unwanted Events AREAS UNWANTED EVENT Large Scale Medium Scale Small Scale Operational Spill During Vehicle Dispensing 200 lt 20 lt 2 lt Spill During Tanker Loading into Tank 1,000 lt 100 lt 10 lt Oil Spill From Vehicles - - 2 lt Fuel Additive Spills - - 1 lt Fuel Forecourt Area Cleaning Wash Water Discharge - - 100 lt VOC Emissions during Car Fuelling VOC Emissions Tanker Loading Fire / Explosion Event Conditionscontaminated water-product 10,000 lt 2,000 lt 200 lt

ERA-Unwanted Events A 25 year old, 20,000 lt capacity single skin tank with no corrosion protection, no automated tank gaging system in place located within a highly corrosive soil environment is very likely to have a catastrophic leak occurrence resulting in loss of greater than 10,000 lt of product. On the other hand, a double skinned 10 year old tank with an interstitial monitoring system and automated gaging system will be unlikely to have a large leakage occurrence.

ERA-Unwanted Events

ERA-Source Pathway Receptor PRIMARY SOURCE SECONDARY SOURCE TRANSPORT PATHWAY RECEPTOR IMPACT UNWANTED EVENTS FUEL FORECOURT AREA: Fuel Spill During Dispensing Fuel Spill During Tanker Loading Oil Spill From Vehicles Fuel Additive Spills Cleaning Washwater VOC Emmissions Car Fuelling VOC Emmissions Tanker Loading Fire / Explosion Event Conditions Impacted Soils <60 cm Impacted Soils >60 cm Dissolved Ground Water Plume Volatilization Atmospheric Disp. Volatilization Enclosed Area Surface Soil Soil Media Air Media Residential, Commercial, Industry Work Area (BP) Sensitive Settings Residential Commercial Industrial Work Area (BP) Utility Confirmed Impact High Risk Medium Risk Low Risk Confirmed Impact High Risk Medium Risk Low Risk Confirmed Impact High Risk Medium Risk Low Risk ASTM E 1739-95 Risk Based Corrective Action Applied to Petroleum Release Sites Free Phase Liquid Below Ground Free Phase Liquid Above Impacted Surface Soils Sediment on Leaching Ground Water Trans. Mobile Free Phase Plume Mobile Free Phase Runoff Stormwater, Surface Water Transport Non Potable Water Well Potable Water Well Sensitive Habitat Surface Water Body Surface Water Runoff Residential Commercial Industrial Work Area (BP) Residential Commercial Industry Work Area (BP) Public Confirmed Impact High Risk Medium Risk Low Risk Confirmed Impact High Risk Medium Risk Low Risk Confirmed Impact High Risk Medium Risk Confirmed Impact High Risk Medium Risk

ERA-Impact Classification Impact Scenario Confirmed Impact High Risk Impact Medium Risk Impact Low Risk Impact Air Media Explosive levels or acute health effects in residential or other buildings Ambient levels exceed concentrations of concern from acute exposure or safety viewpoint Potential explosive levels or acute health effects in residential or other building Toxic levels for receptors in residential or other buildings Non toxic levels for receptors in residential or other Buildings Explosive levels are present in subsurface utility

ERA-Impact Classification Impact Scenario Confirmed Impact High Risk Impact Medium Risk Impact Low Risk Impact Subsurface Soil Soil Contaminant large enough to cause air media confirmed impact classification. Soil Contaminant large enough to cause air media high risk impact classification Soil contaminant large enough to create toxic levels for receptors in residential and other buildings Subsurface > 60 cm below ground is significantly impacted and first potable aquifer less than 15 m Soil contaminant below levels to cause non toxic levels for receptors in residential and other buildings Subsurface > 60 cm below ground is significantly impacted and first potable aquifer is 15 m and above condition valid Surface Water Bodies- Utilities Free product on surface of water body and utilities Impacted surface water, storm water, or ground water discharges < 150 m from surface water body used for drinking water supply Impacted surface water, storm water, or ground water discharges < 450 m from surface water body used for drinking water Supply Sensitive Habitat A sensitive habitat or sensitive resources are impacted and affected Impacted surface water, storm water, or ground water discharges within 150 m from sensitive habitat Impacted surface water, storm water, or ground water discharges within 1500 m from sensitive Habitat Surface Soil Free product on surface soil Contaminated soil open to public access and dwellings, parks, playgrounds, day care centers schools or similar use are within 150 m from soils Contaminated soil open to public access and dwellings, parks, playgrounds, day care centers schools or similar use are within 450 m from soils

ERA-Impact Classification Impact Scenario Confirmed Impact High Risk Impact Medium Risk Impact Low Risk Impact Air Media Explosive levels or acute health effects in residential or other building Ambient levels exceed concentrations of concern from acute exposure or safety viewpoint Explosive levels are present in subsurface utility Potential explosive levels or acute health effects in residential or other building Toxic levels for receptors in residential or other buildings Non toxic levels for receptors in residential or other buildings Ground water Active public water supply well line is impacted or threatened immediately Free product present in non supply well in or outside of the property Potable and nonpotable water supply well impacted or immediately threatened to cause acute effect on receptors Groundwater impacted and public water supply well from the aquifer is located within 2 year projection Ground water impacted and water supply well from the aquifer is located within 2 year projection with potentially acute levels on receptors Groundwater impacted and public-domestic potable water supply well from the aquifer is located in different interval within plume Potable and non potable water supply well is impacted to cause toxic levels on receptors or immediately threatened Groundwater impacted and public water supply well from the aquifer is located greater than 2 year projection Groundwater impacted and water supply well from the aquifer is located greater than 2 year projection with toxic levels on receptors Groundwater impacted and non potable producing well from the aquifer is located in different interval within plume Non potable aquifer with no existing local use impacted Groundwater impacted and non potable wells located wells are located down gradient outside the known extent of chemicals of concern and they produce from non impacted zone Water supply well impacted not above toxic levels on receptors

ERA-Risk Matrix Unlikely Likely Very Likely LIKELIHOOD Low Risk Medium Risk High Risk Confirmed Impact IMPACT LEVELS Environmental targets should have following basis: Take necessary control against confirmed impact independent of the likelihood class Take necessary control against medium and high risk impacts for very likely and likely unwanted events Take necessary control against high risk impact and unlikely unwanted events

ERA-Control Mitigation Available controls based on the following hierarchy: Prevent the occurrence of unacceptable unwanted events Monitor-measure whether the unwanted event has occurred Mitigation measures following the occurrence of unwanted events. The control group means: Presence of written procedures/implementation effectiveness Training - Maintenance Infrastructure / Equipment: standards for prevention and detection systems based on operational practices for tank release prevention and detection, product pipework, vapor pipework, sumps and chambers (European standards for Leak Detection system pren 13160 regulations)

ERA-Control Mitigation

ERA Case Study Station construction :1996 Surface area : 3258 m2 Location: Commercial district / Istanbul Site energy usage: Electricity Water supply: Public water main and on site caisson well: total of 4 tons/day Chemical use : Car wash detergents Surface wash detergents Anti freeze products Fuel additive products Engine oil (small plastic containers) Chemicals stored in enclosed room MSDS sheets not available Secondary containment not present

ERA Case Study Generated wastes: Nonhazardous: packaging, organic waste Hazardous : waste oil, tank bottom cleaning waste, oil water separ gloves-rags Waste Storage : Waste oil contained in 60 liter plastic containers Rags stored in containers Inappropriate storage without secondary containment Poor waste management procedures Wastewater Generated: Wash water, domestic, surface runoff Domestic discharged directly to sewer; car wash water recycled and surface runoff partially conveyed to oil water separator but mostly dir treatment Wastewater Discharge : Municipal sewer line Oil water separator: Three compartment system-linked directly to sewer line Collects liquids formed in the fuel dispensing area Accumulated sludge not emptied regularly-poor maintenance Discharge Permit: Approved for wash water cleaning Not tested for oil water separator discharge Surface water Drainage: Not properly designed; Fuel forecourt drains to separator

ERA Case Study Soil-geology : Fill granular material 0-0.5m; Weathered greywacke 0.5-5.0m Less weathered greywacke 5-8 m; competent greywacke 8 m-15 m; Ground water; Non potable water supply well on site Depth to water 6 m; Yield moderate K estimated at 1x 10-4 cm/sec Water table aquifer-not used for drinking water supply by site or near site vicinity; water quality not tested; Location of well 10 m from oil water separator Risk management measures and procedures not present Emergency procedures present but no training Sensitive Habitat : Not present Setting : Commercial-residential setting; Multistory buildings with basements < 30m from site boundaries; Basement present in retail store-gas detection system in place ; Basements in adjacent surrounding buildings

ERA Case Study Fuel Tanks-dispensing system: Four 20,000 lt double skin 5 year old steel tanks Interstitial space continuously monitored Tanks installed in a concrete vault with monitoring well ATG system in place; checks on ATG system output measured Flexile double skinned pipelines installed 3 years ago Dispenser containment system-checked weekly Overfill prevention valves in place for tanks HDPE manhole sumps present HDPE overspill bucket present in offline filling island Cathodic protection present Dispenser feeding suction and fitting with nozzle shut off valves Vapor recovery systems not present Plans and training On-site hazards and risks training present Risk management measures and procedures not present Emergency procedures present but no training

ERA Case Study TRANSPORT PATHWAY RECEPTOR IMPACT PRIMARY SOURCE SECONDARY SOURCE FUEL FORECOURT AREA: Fuel Spill During Dispensing Oil Spill From Vehicles Fuel Additive Spills Cleaning Washwater Spill During UST Loading The ditch will cause impact to soils below 60 cm. This in turn will create soil pollution below 60 cm. Impacted Soils > 60cm Volatilization Atmospheric Disp. Soil Media Contaminated soils have the potential to create vapors into the work area (BP store), residential and commercial area (basements present) and nearby utility sewer line Confirmed Impact High Risk Medium Risk Low Risk Dissolved Ground Water Plume Volatilization Enclosed Area Air Media Residential Commercial Work Area Utility Confirmed Impact High Risk Medium Risk Low Risk The oil water separator may: Cause impact of soils below 60 cm Lead to free phase liquid below ground Free Phase Liquid Below Ground Leaching Ground Water Trans. Non Potable Water Well Work Area (BP) Confirmed Impact High Risk Medium Risk Low Risk Create dissolved ground water plume Mobile Free Phase Plume On site nonpotable water supply well is used for carwashing and BP workshop area. Free phase migration and or contaminated ground water from leaching of contaminated soil may impact the well Free Phase Liquid Above Mobile Free Phase Runoff Discharge direction into sewer line Spill during tanker loading will create a free phase liquid above ground Surface Water Body Surface Water Runoff Utility Confirmed Impact High Risk Medium Risk

ERA Case Study Unlikely Likely Very Likely LIKELIHOOD Fuel dispensing spill accumulation in leaking oil water separator: Impact on air Impact on soil Fuel dispensing spill accumulation in leaking oil water separator: Impact on ground water Tanker spill during loading: Impact on utility Low Medium High Confirmed IMPACT

PREVENTION IS BETTER THAN THE CURE THANK YOU!