07 40 00/MCE BuyLine 3423 CATALOG 2006 METAL ROOF & WALL SYSTEMS ARCHITECTURAL COMMERCIAL RESIDENTIAL
Since 1963, McElroy Metal has served the construction industry with quality products and excellent customer service. Today, McElroy has nine manufacturing facilities and thirteen service centers across the United States. McElroy Metal s architectural division is focused on helping the architectural and design community find solutions in metal. Here are some of the traits that make McElroy an industry leading metal components supplier: AIA continuing education programs. Quicker than the industry norm lead times on most products. Kynar 500 coating is standard on all McElroy products. Special color match capabilities. Extensive product offering. Technical service support. Table of Contents PRODUCT APPLICATION PAGE PRODUCT APPLICATION PAGE STANDING SEAM Medallion-Lok... Roof, Fascia, Mansard... 1 Maxima... Roof... 2-3 Medallion I... Roof, Fascia, Mansard... 4 Medallion II... Roof, Fascia, Mansard... 5 Meridian... Roof... 6 Mirage... Roof... 7 MasterLok-90... Roof... 7 MasterLok-FS... Roof... 7 SOFFIT/FASCIA Marquee-Lok... Soffit/Fascia/Wall... 8 Matrix... Soffit... 8 EXPOSED FASTENER Mega-Rib... Roof & Wall... 9 Max-Rib... Roof & Wall... 10 Multi-Rib.... Roof & Wall... 10 Multi-V... Wall... 10 5V-Crimp... Roof & Wall... 10 Mini-Rib... Wall, Fascia, Liner... 11 R-Panel... Roof & Wall... 11 Multi-Cor... Roof & Wall... 11 M-Cor... Roof & Wall... 11 U-Panel.... Roof & Wall... 11 RETROFIT ROOFING SYSTEMS... 12 SUBSTRUCTURAL COMPONENTS... 12 SLIT COIL FLAT SHEETS...inside back cover TRIM & ACCESSORIES...inside back cover McELROY INFORMATION & RESOURCES....inside back cover LOCATION MAP...back cover
07 40 00/MCE BuyLine 3423 Medallion-Lok STANDING SEAM SYSTEM Medallion-Lok is a snap-together standing seam system that features a 1 3 /4" seam. Medallion-Lok can be installed over open framing or solid decking..375" 1.75" 12", 16", 18" Factory applied sealant placed in seams 3:12 Minimum Slope Can be installed over solid substrate or open framing Class A - Fire Rating ASTM E1592 - Uplift Test ASTM E1680 - Air Infi ltration ASTM E1646 - Water Infi ltration *Oil canning (pan wave) is a natural occurrence in metal panels and is not cause for panel rejection. Panel Width 12", 16" & 18" Panel Configurations: Striated, Ribbed or Flat Pan Substrate: Galvalume & Aluminum Gauge: 22 and 24 Gauge Steel.032 &.040 Aluminum Factory formed eave notch upon request 1 marketing@mcelroymetal.com www.mcelroymetal.com
Maxima STANDING SEAM SYSTEM Maxima is a vertical leg standing seam system that is mechanically seamed on the roof. Maxima can be installed over open framing or solid decking. Maxima can also be curved to meet radius panel specifications. Mechanically seamed profi le Triple-Lok seam provides unsurpassed strength Factory applied sealant 1:12 minimum slope for 1 1/2" 1/2:12 minimum slope for 2" 1/4:12 minimum slope for 3" Can be installed over solid substrate or open framing Class A - Fire Rating FM 4471 (1-90 Rated) - Uplift Test ASTM E1592 - Uplift Test ASTM E1680 - Air Infi ltration ASTM E1646 - Water Infi ltration *Above testing data does not apply to all Maxima confi gurations. Contact the McElroy Engineering Department for details. Panel Height & Width 1 1/2" x 16", 1 1/2" x 18" 2" x 12", 2" x 16", 2" x 18", 3" x 18", 3" x 24" Panel Configurations: Striated, Ribbed or Flat Pan (2" Seam Only) Minor Ribbed (3" Seam Only) Substrate: Galvalume & Aluminum Gauge: 22 and 24 Gauge Steel.032 &.040 Aluminum Factory formed eave notch upon request 1.5" 16", 18" 1.535" 2" 2.0625" 12", 16", 18" 3" 3.0625" Factory Notching 18" or 24" For enhanced aesthetics and improved installation efficiency, Maxima and Medallion-Lok panels are available with factory fabricated notching. Notching enables contractors to bend the panel ends and eliminate unsightly fasteners along the building eave. Factory notching also eliminates the need for cumbersome and error-prone hand-notching on the job site. Lap notching is also available. *Oil canning (pan wave) is a natural occurrence in metal panels and is not cause for panel rejection. marketing@mcelroymetal.com www.mcelroymetal.com 2
07 40 00/MCE BuyLine 3423 Maxima ADV STANDING SEAM SYSTEM 2" Maxima ADV and 1 1/2" Maxima panels are curved on the job site and feature a vertical leg that is mechanically seamed on the roof. These panels can also be installed fl at (without a radius). Specifiers should use these systems if a 180 seam is desired. Panel width: 16" or 18" Panel Seam: 90 or 180 degree fold Minimum radius: 20' for 2" 12' for 1 1/2" ASTM E1592 Substrates: 22, 24 gauge Galvalume,.032 Aluminum 3 marketing@mcelroymetal.com www.mcelroymetal.com
Medallion I STANDING SEAM SYSTEM Medallion I is an architectural standing seam system featuring a narrow batten cap applied over roofi ng panels and concealed clips. Medallion I is installed over solid decking. Medallion I can also be curved to meet radius panel specifications. 1" 12", 16", 18" Radius Must be installed over solid decking 3:12 Minimum Slope Class A - Fire Rating ASTM E1680 - Air Infi ltration ASTM E1646 - Water Infiltration UL 2218 - Class 4 Impact Resistance Panel Width: 12", 16" & 18" Panel Configurations: Striated, Ribbed or Flat Pan Substrate: Galvalume & Aluminum Gauge: 24 Gauge Steel.032 Aluminum *Oil canning (pan wave) is a natural occurrence in metal panels and is not cause for panel rejection. marketing@mcelroymetal.com www.mcelroymetal.com 4 Panel Width: 12", 16" & 18" Minimum Radius: 30" for Steel 24" for Aluminum Panel Configurations: Ribbed or Flat Pan Substrate: 24 Gauge Steel.032 Aluminum
07 40 00/MCE BuyLine 3423 Medallion II STANDING SEAM SYSTEM Medallion II is an architectural standing seam system that features a 1 1 /2" wide batten cap applied over roofing panels and concealed clips. Medallion II is installed over solid decking. 1.5" 1.5" 12", 16", 18" Must be installed over solid decking 3:12 Minimum Slope Class A - Fire Rating ASTM E1680 - Air Infi ltration ASTM E1646 - Water Infi ltration Panel Width: 12", 16" & 18" Panel Configurations: Striated, Ribbed or Flat Pan Substrate: Galvalume & Aluminum Gauge: 24 Gauge Steel.032 Aluminum *Oil canning (pan wave) is a natural occurrence in metal panels and is not cause for panel rejection. 5 marketing@mcelroymetal.com www.mcelroymetal.com
Meridian STANDING SEAM SYSTEM Meridian is an economical, snap-together roofi ng system that is an excellent choice for commercial and residential applications. Panels are simply installed by placing pancake head fasteners in the panel s slotted flange. Meridian is installed over solid decking. 12" Cover Width.91".91" 3.605" 16" Cover Width Must be installed over solid decking 3:12 Minimum Slope Class A - Fire Rating ASTM E1680 - Air Infi ltration ASTM E1646 - Water Infi ltration Panel Width: 12" & 16" Panel Configurations: 16" Ribbed 12" Ribbed, Striated or Flat Pan Substrate: Galvalume Gauge: 24 and 26 Gauge Steel *Oil canning (pan wave) is a natural occurrence in metal panels and is not cause for panel rejection. marketing@mcelroymetal.com www.mcelroymetal.com 6
07 40 00/MCE BuyLine 3423 Mirage STANDING SEAM SYSTEM Mirage is a concealed fastener roofi ng panel with 1 5 /8" high ribs spaced 8" on center. Mirage can be installed over solid decking or substructural members. 8" 8" 1.625" 16" Coverage 2:12 Minimum Slope Can be installed over solid decking or open framing Class A - Fire Rating ASTM E1592 - Uplift Test Panel Width: 16" Standard Surface: Ribbed Substrate: Galvalume Gauge: 24 Gauge Steel MasterLok-90 & MasterLok-FS STANDING SEAM SYSTEMS MasterLok-90 & MasterLok-FS are trapezoidal standing seam systems designed for projects with slopes as low as 1 /4:12. These systems are best suited for simple sloped roofs without dormers, hips, valleys or other special conditions and can be installed over solid decking or substructural members. MasterLok-90 features a snap together seam while MasterLok-FS is a field seamed panel. 24" Cover Width 3" MasterLok-90 24" Cover Width 3" MasterLok-FS ML90 only Factory applied sealant in seam to Class A - Fire Rating improve weather-tightness Can be installed over solid decking or open framing ASTM E1680 - Air Infi ltration Minimum Slope: 1/4:12 ASTM E1646 - Water Infi ltration Contact McElroy Metal for FS testing *Oil canning (pan wave) is a natural occurrence in metal panels and is not cause for panel rejection. Panel Width: 24" Substrate: Galvalume Gauge: 22 & 24 Gauge Steel 7 marketing@mcelroymetal.com www.mcelroymetal.com
Marquee-Lok SOFFIT, FASCIA & WALL PANEL Marquee-Lok is a soffit, fascia and wall panel that is coated in colors matching McElroy s standing seam systems. The end result is assurance of exact color match between roof system, soffit, fascia and wall panels..4495 1.3925" Matrix SOFFIT PANEL Matrix soffit system will add an elegant touch to any commercial or residential project. Matrix is available in a wide variety of gauges and Kynar 500 colors..9360 12".375" 12" Marquee-Lok shown Panel Width: 12" Panel width: 12" Major Rib Spacing: 6" oc. Panel Height: 0.375" Panel Configurations: Flat Pan, Vented or Pencil Ribs Substrate: Galvalume & Aluminum Gauge: 24, 22 Gauge Steel.032 Aluminum *Oil canning (pan wave) is a natural occurrence in metal panels and is not cause for panel rejection. marketing@mcelroymetal.com www.mcelroymetal.com 8 Surface Configurations: Flat Pan, or Vented Substrate: Galvalume & Aluminum Gauge: 24, 29 Gauge Steel.024 Aluminum
07 40 00/MCE BuyLine 3423 Mega-Rib EXPOSED FASTENER PANELS Mega-Rib is a 7.2 panel that provides optimum strength and spanning capabilities. Mega-Rib is equally well suited for industrial and commercial applications. 7.2" 1.5" 36" Cover Width 7.2" Rib Spacing ICCES Evaluation on 24 Gauge 9 marketing@mcelroymetal.com www.mcelroymetal.com
Max-Rib EXPOSED FASTENER PANELS Max-Rib is a low profile (3/4") panel that is well suited for the commercial, agricultural and residential applications. 36" Cover Width.75" 9" Multi-Rib EXPOSED FASTENER PANELS Multi-Rib is a multi-use wall and roof panel used primarily in pre-engineered metal building applications. 12" 1.1875" 36" Cover Width Multi-V EXPOSED FASTENER PANELS Multi-V is an exposed fastener wall panel that is designed so that fasteners are placed in the valleys, making them visually less apparent. 12" 1.1875 35.5" Cover Width 5V-Crimp EXPOSED FASTENER PANELS Homeowners across the country are discovering that metal roofing not only adds value to their home, but provides beauty as well. McElroy s 5V panel incorporates a classic design that will add beauty to any home. 12" 26.0625" 24" marketing@mcelroymetal.com www.mcelroymetal.com 10
07 40 00/MCE BuyLine 3423 Mini-Rib EXPOSED FASTENER PANELS The symmetrical design of McElroy s Mini-Rib panel make it an appealing profile for soffit, liner and fascia applications. 3".375" 36" Cover Width R-Panel EXPOSED FASTENER PANELS R-Panel is a multi-use wall and roof panel used primarily in pre-engineered metal building applications. 12" 1.25" 36" Cover Width Multi-Cor & M-Cor EXPOSED FASTENER PANELS McElroy s corrugated panels were designed and engineered with greater-than-normal spans and load-carrying characteristics in mind. They quickly communicate their high-strength performance capabilities and are equally well-suited for roof or wall applications. McElroy s Multi-Cor and M-Cor are similar in design, with M-Cor offering a more subtle rib height and configuration. Multi-Cor 2.67".875" M-Cor 2.67".5" 32" Cover Width 37.375" Cover Width U-Panel EXPOSED FASTENER PANELS U-Panel is an exposed fastener wall and roof panel that is also used extensively as a liner or partition panel. 47 64 " 36" 6" 2.46875" 1.03125" 11 marketing@mcelroymetal.com www.mcelroymetal.com
Retrofit Roofing Systems secondary steel concrete wide bay steel wood McElroy Metal, known for high-quality roofi ng products and exceptional services, is ready to be your source for retrofit roofi ng systems. Multiple framing methods are available to handle low and steep slope applications as well as a multitude of special conditions. For additional information please request McElroy s 168 page Retrofit Design Guide or download a copy at mcelroymetal.com Substructural Components McElroy s substructural components - Cees, Zees, Hats, Channels, Angles - represent the broadest selection of cold-formed substructural components in the industry. Cees and Zees from McElroy are manufactured in LGSI (Light Gauge Structural Institute) sections. LGSI sections have been found to have numerous advantages, including greater ease of installation. CEE ZEE HAT CHANNEL MAC-GIRT SUB-GIRT EAVE STRUT marketing@mcelroymetal.com www.mcelroymetal.com 12
Slit Coils & Flat Sheets 07 40 00/MCE BuyLine 3423 McElroy slit coil and flat sheets are available in a wide variety of Kynar 500 colors in both Galvalume and aluminum substrates. McElroy s flat sheets and coils are coated in a variety of Kynar 500 colors for roofi ng, siding, and coping. Trim & Accessories No building project is complete until the fi nishing touches are applied. One of the premier products in the McElroy family, McElroy s Trim Designs will complement any building project. Utilizing state of the art computerized manufacturing facilities, McElroy Trim Designs are produced in a wide variety of shapes and forms and in popular Kynar 500 colors. This computerized manufacturing capability also allows McElroy to offer customized trim, manufactured to exact specifications. Information & Resources SUBSTRATES The most common substrate for McElroy products is GALVALUME. Galvanized and aluminum substrates are also available on some products. PAINT SYSTEMS McElroy offers a variety of popular colors for painted products utilizing McElroy s Premium Fluorocarbon Kynar 500 /Hylar 5000 paint system. Siliconized polyester systems are also available. SPECIFICATION DATA McElroy Metal provides complete architectural specifications for all preformed metal panels. We will promptly fax, e-mail or mail specification to you upon request. Simply contact the McElroy office nearest you or please visit our web site at www.mcelroymetal.com. WARRANTIES McElroy Metal has developed a national reputation for high quality products and exceptional service. To reinforce the strength of this commitment, McElroy makes available limited fi nish and weather tightness warranties. For specific information regarding warranties, contact the McElroy office nearest you. Proud member of these leading associations: marketing@mcelroymetal.com National Roofi ng Contractor s Association www.mcelroymetal.com
SERVICE CENTERS MANUFACTURING LOCATIONS MANUFACTURING & SERVICE CENTER LOCATIONS CORPORATE OFFICE P.O. Box 1148 Shreveport, Louisiana 71163 p 800-562-3576 f 318-747-8029 REGIONAL SALES OFFICES ARCHITECTURAL PRODUCTS DIVISION 555 Dividend Drive Peachtree City, Georgia 30269 p 800-950-6533 f 770-631-0487 MIDWEST REGION Route 10 East Clinton, IL 61727 p 800-950-6532 f 217-935-6615 WESTERN REGION 17031 Koala Adelanto, CA 92301 p 800-950-6536 f 760-246-6595 GREAT LAKES REGION 311 Oliver Drive Marshall, MI 49068 p 800-950-6534 f 269-781-7409 EAST & NORTHEAST REGION 325 McGhee Road Winchester, VA 22603 p 800-950-6535 f 540-667-3440 SOUTHEAST & SOUTHWEST REGION 1500 Hamilton Rd. Bossier City, LA 71111 p 877-859-6061 f 318-747-8059 SERVICE CENTERS 5215 Leo Street ALEXANDRIA, LA 71301 p 888-767-0087 f 318-767-0089 1500 Hamilton Road BOSSIER CITY, LA 71111 p 888-245-3696 f 318-747-8657 3036 Progress Road MADISON, WI 53716 p 800-988-0921 f 608-226-0923 1365 Dean Forest Rd. SAVANNAH, GA 31405 p 912-233-9349 f 912-232-1164 3052 Yadkin CHESAPEAKE, VA 23323 p 888-286-6334 f 757-485-5655 9435 US Highway 60 West LEWISPORT, KY 42351 p 800-844-3724 f 270-295-3274 13742 Giles Road OMAHA, NE 68138 p 800-950-6538 f 402-896-0369 409 Lovejoy Road FT. WALTON BEACH, FL 32548 p 800-950-6026 f 850-664-6840 8304 Highway 70 East NORTH LITTLE ROCK, AR 72117 p 800-950-6539 f 501-945-3028 518 Grider Field Ladd Rd. PINE BLUFF, AR 71601 p 870-536-0161 f 870-536-0167 1500 Country Club Drive JACKSON, MS 39209 p 800-704-7159 f 601-922-2997 165 North Outer Road W. VALLEY PARK, MO 63088 p 888-673-0920 f 636-861-0925 5300 83rd St. SACRAMENTO, CA 95826 p 800-950-8448 f 916-381-9069 1144 Silstar Road WEST COLUMBIA, SC 29170 p 866-494-5316 f 803-926-8139 14373 Creosote Road Building B GULFPORT, MS 39503 p 866-683-1205 f 228-575-9991 MANUFACTURING LOCATIONS BOSSIER CITY, LA p 318-747-8000 f 318-747-8059 CLINTON, IL p 217-935-9421 f 217-935-6615 MARSHALL, MI p 269-781-8313 f 269-781-7409 PEACHTREE CITY, GA p 770-487-6789 f 770-631-0487 LEWISPORT, KY p 270-295-3196 f 270-295-9440 WINCHESTER, VA p 540-667-2500 f 540-667-3440 ADELANTO, CA p 760-246-5545 f 760-246-6595 MERKEL, TX p 325-928-1171 f 325-928-1188 MAUSTON, WI p 608-847-6778 f 608-847-3985 MM101 Rev. 3/06