DESIGN AND DEVELOPMENT OF A SENSORIZED WIRELESS TOY FOR MEASURING INFANTS MANUAL ACTIONS



Similar documents
Machine Tool Inspection & Analyzer solutions

A Data Mining Analysis to evaluate the additional workloads caused by welding distortions

ANALYTICAL AND EXPERIMENTAL EVALUATION OF SPRING BACK EFFECTS IN A TYPICAL COLD ROLLED SHEET

Potential for new technologies in clinical practice

Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM

Scooter, 3 wheeled cobot North Western University. PERCRO Exoskeleton

Video-Based Eye Tracking

Leghe a memoria di forma come tecnologia di attuazione per la biorobotica

Developing a Sewer Inspection Robot through a Mechatronics Approach

METU DEPARTMENT OF METALLURGICAL AND MATERIALS ENGINEERING

Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope

EMG Biofeedback & EMG- Triggered Electrical Muscle Stimulation in pediatric rehabilitation. Schedule. Advanced Muscle Stimulators, LLC

ANALYSIS OF LONG DISTANCE 3-WAY CONFERENCE CALLING WITH VOIP

GOM Optical Measuring Techniques. Deformation Systems and Applications

FEEDBACK ICANE FOR STROKE PATIENT

Closed-Loop Motion Control Simplifies Non-Destructive Testing

ONLINE HEALTH MONITORING SYSTEM USING ZIGBEE

Online Communication of Critical Parameters in Powerplant Using ZIGBEE

Implementation of Wireless Gateway for Smart Home

Web-based home rehabilitation gaming system for balance training

ISSN Vol.14, No.2 December 2003

Research-Grade Research-Grade. Capture

4 Thermomechanical Analysis (TMA)

How To Program A Laser Cutting Robot

Bandwidth Adaptation for MPEG-4 Video Streaming over the Internet

Image guided treatments and simulation

F1 Fuel Tank Surging; Model Validation

COMPUTATIONAL ENGINEERING OF FINITE ELEMENT MODELLING FOR AUTOMOTIVE APPLICATION USING ABAQUS

Recovery and Rehabilitation after Stroke

A General Framework for Tracking Objects in a Multi-Camera Environment

Robotic motion planning for 8- DOF motion stage

Department of Occupational Therapy Doctorate of Occupational Therapy Program

Motivating Children with Autism to Communicate and Interact Socially Through the +me Wearable Device

DIEF, Department of Engineering Enzo Ferrari University of Modena e Reggio Emilia Italy Online Trajectory Planning for robotic systems

DESIGN OF CLUSTER OF SIP SERVER BY LOAD BALANCER

Interfacing with Manufacturing Systems in Education and Small Industry Using Microcontrollers through the World Wide Web

THE CONTROL OF A ROBOT END-EFFECTOR USING PHOTOGRAMMETRY

THE COMPOSITE DISC - A NEW JOINT FOR HIGH POWER DRIVESHAFTS

Infant reflexes and stereotypies are very important in the process of development

Electrical tests on PCB insulation materials and investigation of influence of solder fillets geometry on partial discharge

SAFE A HEAD. Structural analysis and Finite Element simulation of an innovative ski helmet. Prof. Petrone Nicola Eng.

Digital Single Axis Controller

Synchronization of sampling in distributed signal processing systems

GSM Frequency Planning with Band Segregation for the Broadcast Channel Carriers

In-Flight File Transfer. Project Plan: Red Group

Measuring Dental Implant Safety and Performance

MECHANICAL CHARACTERIZATION

Making Better Medical Devices with Multisensor Metrology

STRUCTURAL HEALTH MONITORING AT ROME UNDERGROUND, ROMA, ITALY

NOTCHES AND THEIR EFFECTS. Ali Fatemi - University of Toledo All Rights Reserved Chapter 7 Notches and Their Effects 1

Nano Meter Stepping Drive of Surface Acoustic Wave Motor

IMPLEMENTING A SPC INTEGRATED SYSTEM TO IMPROVE MANUFACTURING PROCESSES IN AUTOMOTIVE INDUSTRY

Measurement of Soil Parameters by Using Penetrometer Needle Apparatus

PRECHTL S METHOD OF QUALITATIVE ASSESSMENT OF GENERAL MOVEMENTS

DETERMINATION OF TIME-TEMPERATURE SHIFT FACTOR FOR LONG-TERM LIFE PREDICTION OF POLYMER COMPOSITES

Vibrations can have an adverse effect on the accuracy of the end effector of a

Unimanual, Bimanual and Bilateral Weight Perception of Virtual Objects in the Master Finger 2 Environment

General movement assessment: Predicting cerebral palsy in clinical practise

Objectives. Experimentally determine the yield strength, tensile strength, and modules of elasticity and ductility of given materials.

CIM Computer Integrated Manufacturing

An application of neural network for Structural Health Monitoring of an adaptive wing with an

Neonatal Reflexes. By Courtney Plaster

Development of Docking System for Mobile Robots Using Cheap Infrared Sensors

FACTORY AUTOMATION INTELLIGENT CLAMP MONITORING FOR MACHINE TOOL SPINDLES WITH INDUCTIVE POSITIONING SYSTEMS

REMOTE BRIDGE MONITORING SYSTEM WITH OPTICAL FIBER SENSORS

INTERACTION CONTROL FOR REHABILITATION ROBOTICS VIA A LOW-COST FORCE SENSING HANDLE

Developmental delay and Cerebral palsy. Present the differential diagnosis of developmental delay.

Tensile Testing Laboratory

Seeing, Thinking, and Doing in Infancy

By Dr. Mindy Aisen CEO and Director United Cerebral Palsy Research and Educational Foundation CEREBRAL PALSY RESEARCH

Performance of voice and video conferencing over ATM and Gigabit Ethernet backbone networks

MASTER DEGREE PROJECT

Implementation of Video Voice over IP in Local Area Network Campus Environment

A MACHINE LEARNING APPROACH TO FILTER UNWANTED MESSAGES FROM ONLINE SOCIAL NETWORKS

REAL TIME TRAFFIC LIGHT CONTROL USING IMAGE PROCESSING

Application of Virtual Instrumentation for Sensor Network Monitoring

Research fields and areas in Physical Therapy and Occupational Therapy

It s All in the Brain!

DESIGN FOR MONITORING AND OPTIMIZATION OF POWER DEMAND FOR WIRELESSLY COMMUNICATING ELECTRIC LOADS

SPEED CONTROL OF INDUCTION MACHINE WITH REDUCTION IN TORQUE RIPPLE USING ROBUST SPACE-VECTOR MODULATION DTC SCHEME

Learning Systems Software Simulation

High-Speed Thin Client Technology for Mobile Environment: Mobile RVEC

Application of Street Tracking Algorithm to Improve Performance of a Low-Cost INS/GPS System

CDMA-based network video surveillance System Solutions

Chapter. 4 Mechanism Design and Analysis

2014 Neurologic Physical Therapy Professional Education Consortium Webinar Course Descriptions and Objectives

Smart Queue Management System Using GSM Technology

Real Time Simulation for Off-Road Vehicle Analysis. Dr. Pasi Korkealaakso Mevea Ltd., May 2015

Neuro-developmental Treatment of Adults with Hemiplegia. Kathryn R. Shaab, PT, DPT Sheltering Arms Hospital May 2008

FDM for Robotic End of Arm Tooling

Series 6000 Torque measured metal bellow coupling

Intelligent Submersible Manipulator-Robot, Design, Modeling, Simulation and Motion Optimization for Maritime Robotic Research

Software Metrics & Software Metrology. Alain Abran. Chapter 4 Quantification and Measurement are Not the Same!

Collecting and analyzing data for understanding the development of. Kaya de Barbaro SIN Network Postdocin Deaklab + Machine perception Lab

Force/position control of a robotic system for transcranial magnetic stimulation

Hybrid Passive and Active Surveillance Approach with Interchangeable Filters and a Time Window Mechanism for Performance Monitoring

Integrated Modeling for Data Integrity in Product Change Management

High-accuracy ultrasound target localization for hand-eye calibration between optical tracking systems and three-dimensional ultrasound

400B.2.1 CH2827-4/90/ $1.OO IEEE

INTRUSION PREVENTION AND EXPERT SYSTEMS

Transcription:

DESIGN AND DEVELOPMENT OF A SENSORIZED WIRELESS TOY FOR MEASURING INFANTS MANUAL ACTIONS Prem Kumar.V, Arun Prakash.M, Sasi Kumar.M, Venkatesh G, Kisshor.A,, 1 UG student- prefinal yr, 2 UG student- prefinal yr, 3 UG student- prefinal yr, Department of EEE, NSIT, Salem 636 305, Tamilnadu, India. Email id: 1 premkumarvvenkatesan@gmail.com, 2 kritanusri@gmail.com, ksasi543@ gmail.com, Abstract-The development of grasping is an important milestone that infants encounter during the first months of life. Novel approaches for measuring infants manual actions are based on sensorized platform usable in natural settings, such as instrumented wireless toys that could be exploited for diagnosis and rehabilitation purposes. A new sensorized wireless toy has been designed and developed with embedded pressure sensors and audio visual feedback. The fulfillment of clinical specifications has been proved through mechanical and electrical characterization. Infants showed a good grade of acceptance to such kind of tools, as confirmed by the results of preliminary tests that involved nine healthy infants: the dimensions fulfill infants anthropometrics, the device is robust and safe, the acquired signals are in the expected range and the wireless communication is stable. Results confirm the hypothesis that this typology of instrumented toys could be useful for quantitative monitoring and measuring infants motor development and ready to be evaluated for assessing motor skills through appropriate clinical trials. Index Terms Force measurement, infants, signal analysis, wireless communication. I. INTRODUCTION: COGNITION and action are mutually dependent.the starting point of development is not a set of reflexes triggered by external stimuli, but a set of action systems activated by the infant. Thus, from this perspective the development of grasping is an important milestone that infants encounter during the firstmonths of life and this enables them to explore and learn about their environment. More specifically the grasping phase is highly dependent on the infant s development. Efficient object manipulation depends on several factors: differentiation of individual fingers movement, grading of grip force, control over the release, bimanual action, in-hand manipulation. Maturation in each of these abilities assists the child s mastery over objects and struggle toward competence.all these manual capabilities are damaged or delayed in infants and children with neurodevelopmental disorders; thus, from this perspective emerges the need to quantify this manual development and grasping capabilities in a rigorous way in order to objectively assess motor impoverishment in pathologic cases. This early diagnosis would open interesting perspectives on early intervention.in fact, currently, infants with neuro developmental disorders have rehabilitation sessions few times a week in rehabilitation centres but according to basic neuroscience it would be necessary to provide them with an early, intensive and multiaxial intervention. Engineering has brought supports in this field also in terms of devices and instruments for quantitative analysis of neuro-motor development, in an emerging field Neurodevelopmental Engineering.The main goals of this field were to propose instrumented tools for monitoring infants neuro-motor development and to provide a new quantitative approach for diagnosis and rehabilitation of neurodevelopmental disorders.in this work, we present the design and the development of a wireless sensorized toy for monitoring infants grasping development that can be used in an ecological environment.in addition the device has been designed in order to be able to measure in a quantitative way the grasping forces of each hand, during playing actions.by means of available low-cost technology and smart design, a new generation of devices would be useful for the assessment of infants motor development. II. MATERIALS AND METHODS: A. Clinical and Technological Specifications: A continuous monitoring of the bimanual grasping actions in infants aged four to nine months-old, without being distressful to the infant, and to operate in an ecological environment are the objectives that clearly set constraints on the kind of technology used. The first two aspects considered when drawing down the requirements are that infants are noncollaborative subjects, i.e., it is not possible to ask them to performa given movement, and the need to measure their natural 84

movements, in an ecological setting.for these reasons, a toy has been chosen as the sensorized device for measuring manual actions in a transparent way;i.e.,during the playtime without affecting the type of play or the type of grasping of the infant. In our case, affordance can, in part, guide the infant to perform certain movements instead a bimanual approach through palmar grasp performed on the two lateral sides of the toy. Soft part design: (a) a view of the generic solicitations performed by the infants on the toy: thanks to the internal core along the principal axis of the cylindrical chamber only the radial contributions (in gray) of the solicitations are detected by the sensors; (b) left CAD view of the transversal (up) and lateral section [mm]; Right soft part components. Both soft and rigid parts are composed of several elements. Soft Part: Each sensitive part has been designed as a soft silicone air-filled chamber, and shaped as a cylinder, connected to a pressure sensor that detects each solicitation on the chamber.one major issue has characterized the design phase of the toy. Sensitive part: to find a solution able to detect only the significant contribution of the palmar grasping action, i.e., the action performed by fingers squeezing the toy against the palm. During the playtime, indeed, infants do several actions on the sensitive parts (e.g., manipulate the toy, try to bring it to the mouth, pull some parts, etc.) that are not useful for measuring infants development. Commercial horseshoe-shaped toy B. Design of the Sensing Device Due to the ecological approach of this work it is not possible to know in advance the exact point of grasping on the toy, so it is preferred to employ types of sensors that can detect and measure a squeezing action in each point of the two lateral sides.at this purpose, a solution based on pressure sensors connected to air chambers, which allow estimating pressure changes inside these chambers, has been designed. This solution, with respect to a simpler one based on switch sensors, allows measuring the amplitude of the force applied independently from the grasping point. The wireless sensorized toy wasmainly composed of two soft sensitive parts made by elastomer shaped as a cylinder and a rigid case (made in epoxy resin) containing the electronicunit. Wireless sensorized toy Rigid Part: Developed to host and protect the electronic unit, the rigid part ensures a safe assembling of the two main soft parts while preserving toy shape and geometry after the assembling. C. Materials: several commercial elastomers have been analyzed in terms of hardness, resistance, viscosity,manufacturing looking for materials with high compliance,easy manufacturing process, elasticity, and easy return to original form. 85

The technical procedures were aimed to investigate the mechanical behaviors of the silicone used in this work and the robustness of the assembled device. A quantitative study on the linearity of the stress-strain curve clearly shows that, despite the variability of the tested rates, the stress stress-strain curves can be approximated with straight lines.concerning hysteresis, since it is an expected behavior for viscoelastic materials, the residual curve has been calculated for each stress-strain curve as the difference between stresses at the same strain, in loading and unloading phases. Results showed that the percentage indexes of hysteresis at different rates are lower than 2%, thus we can conclude that the hysteretic effect is negligible. Electronic unit block diagrams: concepts of the End Device (a) and of the Coordinator (b). D. Electronic Unit: The electronics within the device are composed of three main elements: a communication board, a conditioning board, and the power unit.outside, an external workstation, in which the data are stored and processed, is connected to the toy by using a wireless interface board. This interface board managed the data exchange from and to the device.both the electronic boards within the toy and outside are nodes of a network. E. User Interface: A graphical user interface (GUI) has been developed in order to make simple and suitable to a wide range of users the electronic device.the software has been developed in C# language and it is connected to the coordinator by using the serial communication protocol (RS232).. Stress-strain curves on the silicone at different compression velocities. Calibration setup: CAD view of the probe for compression tests (left), CAD view of the final setup (center), and real compression test setup (right). RESULTS: This section presents the results of the validation procedures meaningful divided in two categories: technical evaluation and experimental validation. A. Technical Evaluation: Calibration curves for left and right sensors and relative linear interpolation By means of these results the designed 86

device can be considered robust and safe enough for the use in clinical trials. Ex perimental validation: sensors outputs of subject 6 during a task of 60 s. The toy dimensions fitted with the infants anthropometrics and the light feedback embedded in the toy not only did not distract the infants attention but it stimulated an active play.furthermore, thanks to the clear toy affordance, the infants performed the required grasping configuration:unimanual or bimanual actions on each side of the horseshoe. Thus, the toy design was useful in the discrimination procedure of the unimanual and bimanual grasping action, although it is still necessary amatching with the video analysis for verifying if the infant grasped the toy correctly and the relative hand used. The video recorded has been useful also to verify that thanks to the internal metallic core only the radial deformation, and so the squeezing actions, were detected by the sensors, as required. The grasping actions are expressed in kpa in terms of maximum and mean values detected and standard deviation for the left and right sensor for each subject.sensors activation thresholds were sensitive enough to detect the grasping actions and the acquired signals were in the expected range so that the sensors never came to saturation. The use of a pressure sensor with respect to some simpler solutions like switch sensors allow to quantitative measure the infant grasping actions and to detect strength impoverishment in case of pathologic cases such as infants with hemiplegia.the network traffic, observed by an external sniffer, showed the transmission time and the packets data that carefully respected the sampling time imposed and the data acquired.the packets lost are less than 1% and these losses were mainly caused by channel conflicts.the transmitting distance depended on the obstacles between Coordinator and End Device but it ranged from 20 m (severalwalls) to 100 m (open air) so for our application this distance is sufficient. V. CONCLUSION: The aim of this work was to develop a wireless sensorized toy for measuring infants manual actions. As pointed out, the clinical requirements set strictly technological challenges that need to be overcome. The use of silicone material has brought important contributions during the design phase as it allowed to shape the air chamber according to the infants needs (in particular the need of safe and attractive material) and infants anthropometrics.in addition, by varying the chamber thickness it is possible to tune the toy sensitivity and this feature is extremely important in applications with infants where the pressure exerted are very low and varying strongly with ages. Moreover, despite the use of viscoelestic materials, the hysteresis is negligible as experimentally proved.on the basis of these first experimental results a functional validation of the device has been obtained, in fact: 1) infants enjoyed the toys; 2) the toys met clinical requirements of measuring infants manual action; 3) the design of the toy has allowed to detect the palmar grasping actions of both hands simultaneously and separately; 4) the hardware and the software of the toy turned out to be robust, stable and safe (i.e., covers, data communication, and transmission, etc.). The system has been provided with a GUI that it is extremely important for an interactive diagnostic tool. In fact the user can follow the trial in real-time and can set parameters and feedback.the infant behavior can be observed without the presence of an operator (e.g., the rehabilitation staff) in the same room. This is an important feature because the presence of the operators and the instrumentation could be distraction sources for the infant and consequently unmanned experimental variables that must be taken into account. From electronic point of view, the approach used in this work and the scalar solution will allow a furtherminiaturization of the board.moreover, the system can be extended so that several toys and consequently several infants behaviors can be observed at the same time. Several infants can play together with the same toy or different ones, and/or an infant can play with several toys. These are examples of interesting experiments that can be carried out by using the technique presented here. Next steps will exploit this tool in clinical trials that involve also infants with neurodevelopmental disorders with the aim to validate it as an auxiliary screening tool used by clinicians to have more data during the diagnosis evaluation. In a qualitative data scenario, as it often happens during the investigation of early diagnosis of neurodevelopmental disorders, this kind of device could be considered a supplementary tool that could give to clinicians quantitative information useful to make the clinical case more clear.in conclusion, the challenges and the efforts of this work are offset by the hope that this new family of tools could represent an important contribution in the development of auxiliary diagnostic devices used by clinicians in ecological environments that can be exploited for the screening of a wide number of infants with diagnostic and rehabilitation purposes. 87

REFERENCES: [1] C. von Hofsten, Action in development, Develop. Sci., vol. 10, no. 1, pp. 54 60, 2007. [2] L. Lhuisset and L. Proteau, Visual control of manual aiming movements in 6- to 10-year-old children and adults, J. Motor Behav., vol. 36, pp. 161 172, 2004. [3] A. Eliasson and P. A. Burtner, Improving Hand Function in Children with Cerebral Palsy. Hoboken, NJ: Wiley, 2008. [4] A. Henderson and C. Pehoski, Hand Function in the Child: Foundations for Remediation. Tacoma, WA: Tomes Poems, 2006. [5] B. Kolb, R. Brown, A. Witt-Lajeunesse, and R. Gibb, Neural compensations after lesion of the cerebral cortex, Neural Plasticity, vol. 8, pp. 1 16, 2001. [6] M. Hadders-Algra, Early brain damage and the development of motor behaviour in children: Clues for therapeutic intervention, Neural Plasticity, vol. 8, pp. 31 49, 2001. [7] G. Cioni, A. F. Bos, C. Einspieler, F. Ferrari, A. Martijn, P. B. Paolicelli, G. Rapisardi, M. F. Roversi, and H. F. R. Prechtl, Early neurological signs in preterm infants with unilateral intraparenchymal echodensity, Neuropediatrics, vol. 31, no. 5, pp. 240 251, Oct. 2000. [8] J. A. Eyre,M. Smith, L. Dabydeen, G. J. Clowry, E. Petacchi, R. Battini, A. Guzzetta, and G. Cioni, Is hemiplegic cerebral palsy equivalent to amblyopia of the corticospinal system?, Neurology, vol. 62, no. 5, pp. 493 503, Nov. 2007. [9] A. Guzzetta, E. Mercuri, G. Rapisardi, F. Ferrari, M. F. Roversi, F. Cowan, M. Rutherford, P. B. Paolicelli, C. Einspieler, A. Boldrini, L. Dubowitz, H. F. Prechtl, and G. Cioni, General movements detect early signs of hemiplegia in term infants with neonatal cerebral infarction, Neuropediatrics, vol. 34, no. 2, pp. 61 66, 2003. [10] D. Campolo, C. Laschi, F. Keller, and E. Guglielmelli, A mechatronic platform for early diagnosis of neurodevelopmental disorders, RSJ Adv. Robot., vol. 21, no. 10, pp. 1131 1150, 2007. [11] D. Campolo, E. Maini, F. Patane, C. Laschi, P. Dario, F. Keller, and E. Guglielmelli, Design of a sensorized ball for ecological behavioral analysis of infants, in Proc. IEEE Int. Conf. Robot. Automat., Apr. 2007, pp. 1529 1534. [12] G. Sgandurra, F. Cecchi, S. M. Serio, M. Del Maestro, A. Guzzetta, E. Sicola, C. Laschi, P. Dario, and G. Cioni, BioMechatronic gym: A new tool in normal and atypical motor development, Develop. Med. Child Neurol., vol. 51, no. 3, p. 24, Jun. 2009. [13] M. Del Maestro, F. Cecchi, S. M. Serio, C. Laschi, and P. Dario, Sensing device for measuring infants grasping actions, Sensors Actuat. A: Phys., vol. 165, no. 2, pp. 155 163, 2011. [14] F. Cecchi, S. M. Serio, M. Del Maestro, C. Laschi, G. Sgandurra, G. Cioni, and P. Dario, Design and development of biomechatronic gym for early detection of neurological disorders in infants, in Proc. Int. Conf. IEEE Eng. Med. Biol. Soc., 2010, pp. 3414 3417. [15] F. Cecchi, S. M. Serio, M. Del Maestro, C. Laschi, and P. Dario, Design and development of sensorized toys for monitoring infants grasping actions, in IEEE RAS/EMBS Int. Conf. BioRob, 2010, pp. 247 252. 88